Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹46.7 L+₹8.1 L (21.1%)Rejected-AOC | L2 | Rejected-AOC Not being L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 Mar 2022, 6:00 pmClosed
GARRISON ENGINEER UTILITY SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIRS TO RO PLANT, STP, OFI, MECHANICAL LAUNDRY, OXYGEN MANIFOLD SYSTEM AND ALLIED WORKS AND REPAIRS / RENEWAL OF DAMAGED WATER SUPPLY DISTRIBUTION LINE AND ALLIED WORKS AT UNIT 289, UNIT 371 AND UNIT 729 ARE UNDER AGE E/M-II OF GE UNDER GE (UTILIT
2022_MES_510314_1
GE(U)/SEC/TOKEN/71 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER UTILITY SECUNDERABAD
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GARRISON ENGINEER UTILITY SECUNDERABAD
₹90,000
Yes
30 Aug 2022
24 Feb 2022
23 Mar 2022
24 Feb 2022
16 Mar 2022
4 Mar 2022
Amount
M&L for spray painting of 100 kg capacity Washing machines at laundry plant MH (incluing inner and outer surface areas and motors also, except stainless steel part/electric panels/belts etc) by apply two coats of metal primer and painting with two coats synthetic enamel paint of existing colour after removing all dust & rust and paint by scrapping with scrapping material shall confirm to IS 2032 including marking of SM/MES Number for each washing machine with stencil letter with black or white paint and Font and Size of letter and white washing for PCC based plinth shall be directed by Engr-in-Charge.
All as per item No 1 here in before but for 50 kg washing machines
M&L for spray painting of drying tubler at laundry plant MH (incluing inner and outer surface areas,motors and econimizer also, except stainless steel part/electric panels/belts etc) by apply two coats of metal primer and painting with two coats synthetic enamel paint of existing colour after removing all dust & rust and paint by scrapping with scrapping material shall confirm to IS 2032 including marking of SM/MES Number for each equipment with stencil letter with black or white paint and Font and Size of letter and white washing for PCC based plinth shall be directed by Engr-in-Charge.
M&L for spray painting of Steam Boilers and chimney at laundry plant MH (incluing inner and outer surface areas,motors,disel tank and econimizer also, except stainless steel part/electric panels/belts etc) by apply two coats of metal primer and painting with two coats synthetic enamel paint of existing colour after removing all dust & rust and paint shall confirm to IS 2032 including marking of SM/MES Number for each equipment with stencil letter with black or white paint and Font and Size of letter and white washing for PCC based plinth shall be directed by Engr-in-Charge.
M&L for spray painting of 50kg capacity hydro extractors at laundry plant MH (incluing inner and outer surface areas and motors also, except stainless steel part/electric panels/belts etc) by apply two coats of metal primer and painting with two coats synthetic enamel paint of existing colour after removing all dust & rust and paint shall confirm to IS 2032 including marking of SM/MES Number for each equipment with stencil letter with black or white paint and Font and Size of letter and white washing for PCC based plinth shall be directed by Engr-in-Charge.
All as per item No 5 here in before but for 25kg Hydro extractor
M&L for spray painting of calander machine at laundry plant MH (incluing inner and outer surface areas and motors also, except stainless steel part/electric panels/belts etc) by apply two coats of metal primer and painting with two coats synthetic enamel paint of existing colour after removing all dust & rust and paint shall confirm to IS 2032 including marking of SM/MES Number for each equipment with stencil letter with black or white paint and Font and Size of letter and white washing for PCC based plinth shall be directed by Engr-in-Charge.
M&L for spray painting of Air compressor unit at laundry plant MH (incluing inner and outer surface areas and motors also, except stainless steel part/electric panels/belts etc) by apply two coats of metal primer and painting with two coats synthetic enamel paint of existing colour after removing all dust & rust and paint shall confirm to IS 2032 including marking of SM/MES Number for each equipment with stencil letter with black or white paint and Font and Size of letter and white washing for PCC based plinth shall be directed by Engr-in-Charge.
M&L for painting of MS/GI pipe line of different sizes by applying two coat of synthetic enameled black colour paint after removing all dust & rust and paint shall confirm to IS 2032 shall be directed by Engr-in-Charge.
Supply & Fixing following spare parts suitable to Drying Tumbler of capacity 50Kg including taking down old unserviceable spare parts complete all as specified and directed for Make of dry tumbler: Supershine or equivalent as approved by GE.
Digital Tempreature meter
Timer
Auxillary contacts
Contactor relay M L 1, 3 phase 415 volts
Contactor relay M L 2, 3 phase 415 volts
Auxilary relay
Revenger (Reverse Forward)
Main Motor -V-belt
Motor bearings
Blower bearings
Reduction gear bearings
Main bearing
Solenoid valve
Push button
Steam strap 15mm
Door Locks
Door Beading
Exhaust Fan/Blower
1/2" Steam Valve
3/4" Steam Valve
Reduction gear V-belt
Brake actuator
Supply & Fixing following spare parts suitable to Hydro Extractor of capacity 25Kg including taking down old unserviceable spare parts complete all as specified and directed for Make of Hydro extractor :Supershine or equivalent as approved by GE.
Contactor M L 1, 3 phase, 415 volts
Timer relay
Transformer
Timer
Buffer
Limit switch
Main motor bearings
Push button
Motor to body springs
Rubber bush for Hydro Extractor
Hydro Extractor motor bearings
Bridge rectifier
Diode
Body Spring support Bolts
Supply & Fixing following spares suitable to Washing machine 50Kg, including taking down old unserviceable spare parts complete all as specified and directed for Make of wahing machine: Supershine or equivalent as approved by GE.
Digital Tempreature meter
Timer
Contactor relay M L 1, 3 phase, 415 volts
Contactor relay M L 2, 3 phase, 415 volts
Relay M L 1, 3 phase, 415 volts
Relay M L 2, 3 phase, 415 volts
Revenger (Reverse Forward)
Water Level Indicator
Steam solenoid Valve
Drain valve actuator
Main motor V-belt
Aux Motor V-belt
Washing Machine main bearing
Reduction gear bearing
Water inlet solenoid valve suitable for 50 kg washing machine
Water outlet solenoid valve suitable for 50 kg washing machine
Gland rope
Main motor bearings
Aux Motor bearings
Toggle swtich
Supply & Fixing following spare parts suitable to Boiler of capacity 600Kg/Hr including taking down old unserviceable spare parts complete all as specified and directed for Make of boiler: Thermax or equivalent as approved by GE.
Gland Washer (HTN-8)
Valve seat Assembly
Metalic Hose 3/8" x 40"
Oil Seal (HTN-5)
Oil Seal (HCA-7)
Ball Bearings (HCA-5)
Pressure Switch PVF 1.0
Pressure Switch PVF 16
Metallic Hose 1" x 1.2m
Limit Switch
Photocell 8205
Sequence controller MA 810
Solinoid Coil
Electrode Assembly
Electrode Cap
High Tension Wire
Packing Hylam
Packing Asbestos
Gland Nut (HTN-6)
Oil Level Indicator
Sight glass 50mm
Ignition Transformer 14.5 KV
Temperature Controller 0-400V
RTD Assembly 2.5 mtrs
Safety valve 25mm
Plug & Socket
Hooter 4" Dia
Lip Seal
Spider for love joy couple
Burner rod Without nozzle
Fuel Pump
Diffuser Plate 132mm dia
Nozzle 6.5 GPH, 45 Degree
Disel line Y strainer 25mm dia
Disel line globe Valve 25mm dia
Steam line Y strainer 25mm Dia
Steam line Globe valve 25mm Dia
Steam line Y strainer 40mm Dia
Supply & Fixing following spares suitable to Washing machine 100Kg including taking down old unserviceable spare parts complete all as specified and directed for Make of washing machines: Supershine & Megha laundry or equivalent as approved by GE.
Digital tempreature meter
Timer
Contactors ML 1, 3 Phase, 415 Volts
Contactors ML 2, 3 Phase, 415 Volts
Contactor relay M L 1, 3 phase, 415 volts
Revenger (Reverse Forward)
Water Level Indicator
Steam solenoid valve
Drain valve actuator
Main motor V-belt
Aux motor V-belt
Washing Machine main bearing
Reduction gear bearing
Indicator
Water inlet solenoid valve suitable for 100 kg washing machine
Water outlet solenoid valve suitable for 100 kg washing machine
Gland rope
Door Lock Knobs
Steam Valve (Globe)
Main motor bearings
Aux motor bearings
Toggle swtich
Supply & Fixing following spare parts suitable to Air Compressor of capacity 5HP including taking down old unserviceable spare parts complete all as specified and directed.
Limit switch
Motor bearings
Compressor Bearings
Piston Kit
Supply only following items all as specified and directed.
Wax (Candle Powder)
Grease (Castrol Make)
Chemical salt
PPM Testing Liquid Set
Laundrex softener chemical
Laundrex Det
Laundrex boost
Laundrex neutral
Meghana Liquid Bleach
Supply & Fixing spare parts suitable to calender Machines including taking down old unserviceable spare parts complete all as specified and directed for Make of calender machines: Supershine & Megha laundry Eqpts or equivalent as approved by GE.
Variable frequency drive
Padding cloth
Blower Motor Rewinding
Temperature Meter
Speed Regulator
Push buttons (Red, Green,Blue)
NO-Element
NC-Element
Toggle Switch
Steam Solenoid Coil 15 mm
FLR Unit
Steam inlet Braided hose pipe 1" x 2 ft
Pneumatic cylinders servicing only except spares
Wax for cleaning chest
Guide Ribbons
Painting for feeding plate
Grease for chain and gear wheel teeth
Steam trap servicing
Air line and steam line with all connectors
Lubrication oil and gear oil
Steam line Y strainer 25mm dia
Disconnecting of Motor from washing machine/ Hydro extractor/ Drying tumbler/flat bed press machine/bioler/any other equipment in laundry plant etc and material and labour for re-winding of electric motor with super enameled copper wire of good quality with same gauge and same size complete with all accessories including varnishing the winding for improvement of insulation by heating method and reassembling, installing, commissioning and testing after repair / rewinding, greasing and gland packing & necessary balancing arrangement with rubber bushes complete including transportation charges from site to work shop and back to its original position complete all as specified and directed for the following capacities:-
(a)up to 2 Hp
(b)above 2 HP to 5Hp
(c) above 5Hp to 10Hp
M&L descaling of the following laundry equipments with approved descaling chemicals complete all as specified and directed.
Washing machine of 100 Kg capacity
Washing machine of 50 Kg capacity
600 Kg/hr boiler
Supply & Fixing following spare parts suitable to Hydro Extractor of capacity 50Kg including taking down old unserviceable spare parts complete all as specified and directed for Make Hydro extractor :Megha laundry Eqpts or equivalent as approved by GE.
Contactor M L 1, 3 phase, 415 volts
Timer relay
Transformer
Timer
Buffer
Limit switch
Main motor bearings
Push button
Motor to body springs
Rubber bush for Hydro Extractor
Hydro Extractor motor bearings
Bridge rectifier
Diode
Body Spring support Bolts
Supply & Fixing following spare parts suitable to Air Compressor suitable for capacity up to 2HP including taking down old unserviceable spare parts complete all as specified and directed
Limit switch
Motor bearings
Compressor Bearings
Piston Kit
Drain out the fuel from the fuel tank of Boiler of capacity up to 1000ltrs and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as directed by Engr-in-charge.
S&F in MS Pipe line laid in trenchs/duct/ug/surface/wall/floor alongwith aluminium Cladding insulation including following accessories complete all as directed by Engr-In-Charge at the Loundry Plant at Military Hospital
2 1/2" MS C Class Pipe
2 1/2" MS T/E Flanges
2 1/2" MS Long Bends
25mm C Class Pipe
25mm T/E MS Flange
1"x 6" MS long Bends
1"x 6" MS Nipples
1" Elbow
1" Steam Traps
1" MS Union
1" Axe Nipples
Bolts and Nuts suitbale to existing Pipes at Loundry plant , MH
1/2" Teflon tapes
1" globe valves
Welding Rods
Metallic Sheet
Cutting Wheels
M&L for door bedding for 50/100kg washing machines/drying tublers located MH laundry plant including taking down old unserviceable one complete all as directed by Engr-in-Charge.
Supply, lay, connect test and commissioning of solid copper conductor cable XLPE insulated screened PVC tape innersheathed, unarmoured electric power cable heavy duty with aluminium conductor 1100 volts grade corss sectional area of 16 Sqmm single Core confirming to IS:7098 Part-I laid in trenches/floors complete testing and commissioning complete all as directed. Make :- KEI Industries Ltd or equivalent in Havells/ Polycab/Plaza as approved by GE.
All as per Item No. 25 here in before but for 25Sqmm single core all as directed by Engineer-in-Charge
All as per Item No. 25 here in before but for 50Sqmm single core all as directed by Engineer-in-Charge
Supply and fixing Gun-metal glove or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of following sizes:-
25mm dia bore
40mm dia bore
50mm dia bore
S&F 2000 Ltrs capacity rotational mountain polythene water storatge water tank triple layered as per IS-1270 - 1989 hoisted 2500 dia ball valve brass eith plythene float and fly nut and fixed in position including suitable inlet & outlet pipe ine connections & necessary platform complete including removing existing unserviceable tank complete all as directed. Make: Sintex / Polycon or equivalent as approved by GE.
Excavation in trenches in hard/dense soil not exe-1.5 mtr deep and not exe 1.5 mtr wide and getting out complete all as specified.
Returning filling in and including spreading, leveling, watering and well remaining in layer not exceeding 25 cm complete all as specified
Removal of surplus soil to a distance not exceeding 50 mtr and depositing under directed at a level not exce1.5 mtr above the starting point all as specified
Cleaning of Sewer collection chamber at E coy and FAE of MCEME by using mechanical means and cleaning the complete chamber including sludge of capacity 50000 liter complete all as specified and directed. Note: i) Quoted rates inclusive of all arrangements required for complete cleaning of the sump and the sewage / sludge to bo removed from the site and deposited to the outside Amry areas as per HMWS&SB guidelines.
Cleaning of Sewer collection chamber using mechanical means and cleaning the complete chamber including sludge of capacity 25000 liter complete all as specified and directed. Note: i) Quoted rates inclusive of all arrangements required for complete cleaning of the sump and the sewage / sludge to bo removed from the site and deposited to the outside Amry areas as per HMWS&SB guidelines.
Supply and fixing stainless steel grade (SS-304) pipe / square bar varying from 10 mm to 32 mm dia with all fittings and fixtures for provision of air grid laid in floors or fixed to wall, ceiling etc including necessary welding joints etc. and taking down old one complete all as specified. Note: The above item is uned for making cover of collection chamber / sattling tank of existing STP
Supplying, laying and testing of mild steel tubes 50 mm bore , ISI marked (IS-1239) (ISI marked) heavy grade with all fittings and fixtures laid in floors or fixed to wall, ceiling etc including necessary welding works including taking down old one complete all as specified .
Supply & fixing CI butterfly valve, flanged type, confirming to IS 13095 suitable for 50 mm bore pipe complete all as specified.
Supply & fixing CI butterfly valve flanged type, confirming to IS 13095 suitable for 65 mm bore pipe complete all as specified.
Supply & fixing CI butterfly valve flanged type, confirming to IS 13095 suitable for 80 mm bore pipe complete all as specified.
Supply & fixing CI butterfly valve, flanged type, confirming to IS 13095 suitable for 100 mm bore pipe complete all as specified.
Supply and replace column / suction pipe of sewage pumps including necessary fittings of doa 80 mm complete all as directed
Testing of water samples for bacteriological and chemical analysis as mentioned below from Pump Houses viz RCPH, GLPH, RAMC, GRPH High level , Safilguda, 36 JCO mercury, CTW, A Coy, B Coy 'C' Coy E 'Coy', HQ Coy, MH OHT, DGQA, DAD and certain other areas.complete all as specified and directed. Note: Testing of water for meter o water for Testing of water and Treated water in Each PH consider as One Job (a) Sample of Water for the above media test are to collected in transparent container/ Jar/bottle separately for each test against each pump house. ( Hyginenically clean bottles). 9b0 Sample of water to be collected shall be forwarded to Govt Lab.
Testing of Sewage Water Samples for BOD and COD testing analysis of 80 KLD STP at FAE complete all as specified and directed. (a) BOD (b) COD (a) PH Level (d) Total Suspended Soild (TSS) (e) Outlet Coliform Note: Testing of Sewage Water Treated sewage Water for total 06 STPs in three month Basis. (i.e Treated Sewage water in Each STPs consider as one Job) (a) Sample of Sewage Water for the above media test are to collected in transparent container/Jar/bottle separately for each test against each STPs. (Hygienically clean bottles). (b) Sample of water to be collected shall be forwarded to Govt Lab / any authorized Lab
Supply and replace unserviceable doors / covers of machinaries installed at mechanical laundry by using MS shhet of 2 mm thick including 2 coats of synthetic enamelled paint over a coat of redoxide primer complete all as directed. Note: Quoted rates inclusive of all arrangements required including bending and welding during execution
Attending repair/rectification of leakages to water supply distribution lines 20 mm bore to 25 mm bore GI/PPR tubing with provision of necessary excavation, returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of GI unions/sockets/nipples as required at site complete all as specified and directed.
All as per Item No. 43 here in before but for GI tubing 40 mm bore to 50 mm bore
All as per Item No. 43 here in before but for GI tubing 80 mm bore to 100 mm bore.
Attending routine compaints of external water supply including rectification of minor defects by taking down of existing GI/PPR tubing up to 25 mm bore, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of jumper valve/ packing sheet of gate valve and including replacement of GI unions/sockets/nipples etc as required at site complete all as specified and directed.
All as per item No 46 above but for GI tubing 40 mm bore to 50 mm bore.
M&L for attending break down of water supply pipe line and repair to CI/DI/PPR water mains of size 80 mm to 300 mm bore at a given notice including necessary excavation in mud, in any type of soil by manual or using special T&P such as JCB etc. De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI specials such as collars, bends/tail peaces etc and making joints complete all as specified and as directed. Note:- CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of BOQ.
Notes for Sl item No 43 to 48 :- (a) The contractor will be alloted complaints at MES complaint cell on requirement basis on all working days including Sundays and holidays and sufficient tradesman / resources will be deployed by him/her for completion of day to day comaplaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of genuine cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log book of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with JE E&M/Engr-in-Charge. (c) The contractor will make suitable arrangment for emergency complaints and will notify authorised representive/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.
(d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare/fittings utilized as per inventry format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No II store yard on requirement basis. (g) The stationery required for the job work such as complaint slip books, gate pass book, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work and repairs to damaged roads, LT UG/HT cables, existing structure etc shall be deemed to be included in the quoted unit rate and no extra payment shall be allowed on this account. (j) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
Taking up or down steel tubing and connections, including cleaning the pipes free from scaling for for re-fixing or removal complete with all fittings and connections of the following sizes :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Refixing of old steel tubing and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Notes for item No 50.01 to 50.07 :- (a) Excavation and Earth work shall be measured and paid separately.
Refixing of old steel tubing and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
Supply and laying steel water tubing medium grade, galvanised with all fitting, laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Notes for item No 52.01 to 52.07 :- (a) Excavation and Earth work shall be measured and paid separately.
Supply and laying steel water tubing medium grade, galvanised with all fitting, fixed to wall and ceilings or laid in floor and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
Taking up unserviceable/ defective CI/DI/MS water mains (including all fitting ) with spigot/ socketed / flanged ends including disconnecting pipes and fittings in any position complete all as specified and directed for the following sizes:-
80 mm Dia
100 mm Dia
150 mm Dia
Refixing of old CI/DI/MS Pipe and connection after cleaning in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
80 mm dia
100 mm dia
150 mm dia
Notes for item No 56.01 to 56.03 :- (a) Excavation and Earth work shall be measured and paid separately.
S&F ductile iron pressure pipes, class K9, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified and directed for the following sizes:- Notes:- (a) Lead Joints / D-Joints will be measured and paid separately. (b) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment if required. (c) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
80 mm Dia
100 mm Dia
150 mm Dia
Notes for item No 57.01 to 57.03 :- (a) Excavation and Earth work shall be measured and paid separately.
Cutting existing CI pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:- Note: CI /DI specials, Joints and Earth work shall be measured and paid sperately under relevant items of this schedule.
80 mm Dia
100 mm Dia
150 mm Dia
Supply only GI fittings 15 mm bore, medium grade, ISI marked, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:-
Union
All equal Tee
Socket
Nipple 75mm Long
Elbow
Hex Nipple
All as per Item No. 59 here in before but for 20 mm bore.
Union
All equal Tee
Reducer Tee 20 x 20 x 15 mm
Socket
Reducer Socket 20 x 15 mm
Nipple 75mm Long
Reducer Elbow 20 x 15 mm
Elbow
Hex Nipple
All as per Item No. 59 here in before but for 25 mm bore.
Union
All equal Tee
Socket
Reducer Socket 25 x 20 mm
Reducer Socket 25 x 15 mm
Nipple 75mm Long
Elbow
Reducer tee 25mm x 25 mm x 20mm
Reducer tee 25mm x 25 mm x 15mm
Hex Nipple
All as per Item No. 59 here in before but for 40 mm bore.
Union
All equal Tee
Socket
Reducer Socket 40 x 25 mm
Nipple 75mm Long
Elbow
Reducer tee 40mm x 40mm x 25mm
Reducer tee 40mm x 40mm x 20mm
Hex Nipple
All as per Item No. 59 here in before but for 50 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer 50mm x 40mm.
Reducer 50mm x 25mm.
Elbow
Reducer tee 50mm x 50 mm x 40mm
Reducer tee 50mm x 50 mm x 25mm
Hex Nipple
All as per Item No. 59 here in before but for 80 mm bore.
Union
All equal Tee
Socket
Reducer 80mm x 50mm.
Reducer 80mm x 40mm.
Nipple 75mm Long
Nipple 150mm Long
Elbow
Reducer tee 80mm x 80mm x 50mm
Reducer tee 80mm x 80mm x 40mm
Hex Nipple
All as per Item No. 59 here in before but for 100 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer tee 100mm x 100mm x 80mm
Reducer tee 100mm x 100mm x 50mm
Reducer tee 100mm x 100mm x 40mm
Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed for the following sizes:-
15mm dia bore
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
Note for Sl item No 66.01 to 66.05, Make : Zoloto or equivalent as approved by GE.
Supply and fix in replacement of unserviceable ball brass valves, high pressure with polythene float and fly nut alongwith socket/reducer of suitable size, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed for the following sizes:-
20mm dia bore
25mm dia bore
M&L for dismantling of defective sluice valve for repairs, such as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly etc, replacement of jointing materials such as rubber sheets, nuts, bolts, washers and gland rope etc and refixing in its original position, testing on completion complete all as specified and directed for the following sizes:-
80 mm Dia
100 mm Dia
150 mm Dia
S&F CI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single 'Y' branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed.
All as per Item No. 69 here in before but for 200 mm bore to 300 mm bore.
Burning out lead joint in position for following sizes of CI/DI pipe, removing old lead complete all as specified and directed :-
80 mm Dia
100 mm Dia
150 mm Dia
M&L for run lead joint for CI pipe/DI pipe including spun yarn etc for spigot and socket pipes and fittiings complete all as specified and directed for the following bore of pipes:-
80 mm Dia
100 mm Dia
150 mm Dia
S&F in repairs CAST IRON OR DUCTILE IRON MECHANICAL COUPLING / MECHANICAL JOINT / D JOINT heavy duty INCLUDING ALL JOINTING MATERIAL , ISI marked, split type with long collar, suitable rubber rings, bolts, nuts and washers etc suitable for MS/CI/DI/GI /PVC pipes of following sizes AS REQUIRED FOR REPAIRING OF ANY KIND OF LEAKAGES COMPLETE all as specified and as directed:- Notes:- (a) Excavation and Earth work shall be measured and paid separately. (b) Quoted rate inclusive of cutting of any kind of pipes and all ITEMS as required for fixing and proper functioning of Joints. (c) Quoted rate is deemed to be inclusive of necessary T&P for cutting the pipe line, Pump sets for De-watering, JCB for Excavation (if required) etc and no extra payment shall be admissible on this account.
80 mm Dia
100 mm Dia
150 mm Dia
S&F in replacement of Cast Iron sluice valves flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, non rising type K504, class PN 1.6 including jointing materials connecting and testing complete all as specified and directed.
80 mm Dia
100 mm Dia
150 mm Dia
S&F in replacement of Cast Iron sluice valves flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, rising type K506, class PN 1.6 including jointing materials connecting and testing complete all as specified and directed.
150 mm Dia
Cutting the existing road straight by manual, depth and width not less than 30 cm for pipes up to 100 mm dia and 60 cm for pipes from 150 mm to 150 mm dia and 75 cm for pipes above 250 mm dia and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed.
Construction of valve chamber of size 900 x 900 mm (Internal size) 900 mm deep with 200mm thick PCC block masonary walls built in CM 1:6 over 100 mm thick foundation concrete in PCC 1:4:8 type D2, (Using 40 mm graded coarse aggregate) with 100 mm off set, 15mm thick complete internal plaster and external plaster up to a depth of 15 cm below GL in CM (1:6), 3 mm thick MS sheet cover, double door welded to 50 mm x 50 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1 coping 50 mm thick in PCC (1:2:4) type B-1, 20mm x 6mm flat iron hinges with locking arrangement including lock sixty five mm, brassd and keys(Godrej/Shell), MS handles and applying two coats of synthetic eanmel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any type of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 Mtr complete all as specified and directed
M&L for replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including welding, bending cold or hot, drilling holes for hinged, in any shape or size as indicated for valve chamber top cover, 4 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with locking arrangement, mild steel handle, and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, MS casing pipe havy duty of size150 mm dia with 6 mm thick in any length including jointing materials to carry water supply pipe line of size upto 150 mm dia and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, etc. including Use and Waste of Formwork (if required), complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) as in Side Wall of Cable Duct, etc., complete all as specified and as directed.
Supply & lowering HDPE heavy duty coloumn pipe in bore well af ter fixing with submerceable pupmsets of internal dia 50mm PN 16kq/Sqmm including necessary fixing arrangement with submerceable motor, and necessary clamp for supporting at the top portion of bore well complete all as d specified and directed. Make : Sudhakar Note: Quoted rates inclusive of lowering of pipe in bore well, necessary connection with MOTOR by using GI fittings, clamps , nutbolts etc as required of heavy duty, 2 sets of clamps for supporting of pipes at the TOP
Supply and replace single phase preventor cum low level water guard suitable for 4 to 7.5HP submersible pump set complete all as directed by Engineer-in-Charge.
Supply and replace DOL starter suitable for 5/ 7.5 HP submersible pump set of 3 phase including necessary internal wiring with suitable copper wire including testing and commissioning complete all as directed by Engineer-in-Charge.
Taking out unserviceable GI socket from 50 mm column pipe and S&F new GI socket 50mm (ISI marked) long type, heavy duty suitable for the column pipe complete all as directed by Engineer-in-Charge.
Cutting the existing damaged threading of GI column pipe 50 mm dia and re-threading on lathe machine complete all as directed by Engineer-in-Charge.
Removing old unserviceable column pipe as obtained from lowering of submersible pump set and S&F new GI column pipe 50mm dia, heavy duty, ISI marked, 3 metre length each, both ends machine threaded with long threaded socket complete all as directed by Engr-in-Charge.
Removing unserviceable PVC water proof cable of any size as obtained from lowering of submersible pump set and S&F new PVC water proof copper cable of size 3 core 2.5 sqmm suitable for submersible pump set complete all as directed by Engr-in-Charge.
M&L for cable joint for water proof cable of 3 core 2.5 /4.0 sqmm flat copper cable including testing and commissioning complete all as directed by Engineer-in-Charge.
Removing unserviceable PVC water proof cable of any size as obtained from lowering of submersible pump set and S&F new PVC water proof copper cable of size 3 core 4.0sqmm suitable for submersible pump set complete all as directed by Engr-in-Charge.
M&L for cable joint for water proof cable of 3 core 4.0 sqmm flat copper cable including testing and commissioning complete all as directed by Engineer-in-Charge.
M&L for flushing of the existing borewells of size 150 mm dia upto 350 feet depth by drilling machine by mechanically method into the above well connected to a pneumatic compressor after taking out the submersible pumpset with necessary hoisting equipment and flushing the bore well complete with compressor air and flushing bore well till discharge of fresh water is obtained subject to the entire satisfaction of Engr-in-charge and lowering down the submersible pump set in position complete all as directed by Engineer-in-charge.
Taking out submersible pumpset of any capacity and type from the borewell of depth not exc 200 metres for carrying out repairs including cleaning and applying one coats of anti corrosive paint and lowering the same in position and commissioning after carrying out the repairs as required complete all as directed by Engineer-in-Charge. Note:- i) Rewinding of burnout winding of motor,supply of parts repairs to pumpset will be measured under relevant item of this BOQ.
Repairs to submersible motor electric driven up to 5 HP capacity of any make and type by rewinding of the motor with same gauge and weight of PVC insulated copper wire and other required insulating materials and renewal of thrust plate, bearing , reassembling, including testing and commissioning complete all as directed by Engineer-in-Charge.
Repairs to submersible motor of electric driver, above 7.5 HP up to 10 HP capacity of any make and any type by rewinding the motor with same gauge and weight of PVC insulated copper wire and other required insulating materials and renewal of thrust plate, bearing ,reassembling, including testing and commissioning complete all as directed by Engineer-in-Charge.
Repairs to submersible pumpset upto 18 stage, replacing the worn out spare parts with new spare parts overhauling and greasing including testing complete all as directed by Engr-in-Charge. Note:- spare parts as required for functioning of of PUMP set shall be included in the quoted rate
Disconnecting and removing the water and electric connections care fully from the existing Burnt centrifugal pump sets of capacity 5 / 7.5 HP and shifted to workshup for rewinding with same guage of copper wire , replacement of bearing , thrust plate etc as required for proper functioning of the centrifugal motor anf refix the same on its own position along with all electric and water connection complete all as directed. Note : The spares required for repair the pump sets and rewinding of motors deemed to be included in the quoted rate.
Supply and installation CPRI approved pump starter electric control panel board, for INdoor use, DOUBLE door ( BOTH DOOR HAVING LOCKING ARRANGEMENT INCLUDING 2 NOS GODREJ 7 LIVER LOCK) dust & vermin proof floor mounted made out of CRCA steel sheet of 2 mm thick angle iron legs of size50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary PCC work of height 300 cm from the ground level including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following( Leg of the panel should not be less than 0.75 M and size of the panel should not be less than 70CmX70CMX30CM)) :-
INCOMMING :- (a) MCCB, 4 pole, 415 Volt, 40 Amps, 16 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCCB, 3 pole, 10 KA c Curve 415 volts, 25Amps -02 No (b) DOL starter in sheet enclosure type MK-1, Motar rating AC-3 duty, 415 volts, 50 Hz suitable FOR 7.5 HP relay max rang 15-25 Amps-02 No. (c) Single phase preventor realy type Sz% (6wire), 415 volts -01 No
Supply and installation CPRI approved pump starter electric control panel board, for out door use, DOUBLE door ( BOTH DOOR HAVING LOCKING ARRANGEMENT INCLUDING 2 NOS GODREJ 7 LIVER LOCK) dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick angle iron legs of size50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary PCC work of height 300 cm from the ground level including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following( Leg of the panel should not be less than 0.75 M and size of the panel should not be less than 70CmX60CMX30CM)) :-
INCOMMING :- (a) MCCB, 4 pole, 415 Volt, 40 Amps, 16 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCCB, 3 pole, 10 KA c Curve 415 volts, 32 Amps -01 No (b) DOL starter in sheet enclosure type MK-1, Motar rating AC-3 duty, 415 volts, 50 Hz suitable FOR 7.5 HP relay max rang 15-25 Amps-01 No. (c) Single phase preventor realy type Sz% (6wire), 415 volts -01 No
Material labour for removing submerceable pump motor set of capacity up to 7.5 HP stuck in side the borewell of depth up to 100 meter by flushing the existing borewells of any size with drilling compressor mounted on truck at a pressure of 7 Kg / Sqcm with compressed air and flushing the sand, mud including flushing out tree roots etc from the bore well till removing of the stuck motor and then clear the bore by using Rod drilling using Bore well drilling machine from any kind of obstruction, reinstall the motor and coloumn pipe , necessary electric connection and testing complete all as specified and directed . Note: Rate quoted by the contractor inclusive of Flushing by using suitable compressure, rod drilling for clearing of bore well, Removing the submerceable pump set stuck inside the bore well and reinstall the same after repair including removing and refixing of coloumn pipe, electrical connections, testing etc as required.
Supply and fix MCB SP&N 32 Amps 10 KA C Curve . Make L&T model BB20320C /Legrand/havells/C&S as approved by GE.
Supply and fix MCB SP&N 25 Amps 10 KA C Curve . Make L&T model BB20325C /Legrand/Havells/C&S as approved by GE.
Supply and fix MCB SP&N 20 Amps 10 KA C Curve . Make L&T model BB20200C /Legrand/havells/C&S as approved by GE.
Supply and fix MCB TP&N 20 Amps 10 KA C Curve . Make L&T model BB40200C /Legrand/havells/C&S as approved by GE.
Supply and fix MCB TP&N 32 Amps 10 KA C Curve . Make L&T model BB40320C /Legrand/havells/C&S as approved by GE.
Supply and fix MCB TP 20 Amps 10 KA C Curve . Make L&T model BB30200C /Legrand/havells/C&S as approved by GE.
Supply and fix MCB TP 32 Amps 10 KA C Curve . Make L&T model BB30320C /Legrand/havells/C&S as approved by GE.
Supply only Bleaching powder Grade-I, IS 1065:1989(used in drinking water), stable dry free flowing white in appearance without hard lumps and visible impurities in laminated high density polythene bags of 25 Kgs capacityof each bags. Make : ADITYA BIRLA CHEMICALS LTD (DC) /RAMCO/GRASIM/DCM
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification . GI Electrode Shall be tested from CPRI.The earting pit should be cover with pcc(1:2:4 , B1) cover ,of 450 x 450 mm complete all as specified and directed. Make : ASHLOK / INDELEC/JMV /TERCEL.
Serviceaning / periodical checking of Starter panel board suitable for 5 HP to 10 HP Motor by replacing all unserviceable parts , checking for any kind of loose contact , identification of fault etc complete all as specifed and directed . Note : All spare to be replaced and measured under relivent items.
Servicing of Submerceable pump motor set of capacity up to 10 HP complete all as directed
Attending Breakdown of any capacity any type ( Submerceable, Monoblock, Cetrifugal etc) of PUMP SETS , Starter panel by Technitian and Helper for checking all parts and rectify the faults and give reports to concern JE as directed by Engr-In-Charge Note : All spare parts to be replaced and paid against respective items.
Arresting lekages from pumps of motor capacity 05 HP to 25 HP by replacing gasket, nutbolts, gland packing etc as required complete all as directed Note: Rate quoted by the contractor inclusive of all items as requiree to arrest the leakages from pumps
M&L for Painting of centrigfugal pumpset of capacity up to 10 HP complete in all arespect including ite inlet and outlets pipes, valves, base frame complete with synthetic enamelled spray painting complete all as directed
Material and labour for drilling vertically from average ground level for 200 mm dia bore hole in any type of strata by mud flash rotary ring including cost of drilling shall be done by mud flash rotating quipment bore shall be unsealed at least for 48 hours to the entire depth of bore holes, depth of bore hole from 0 to 100 meters depth including sub soil complete and removal of drilled/board materials to a distance not exceeding 50 mtr, spreading leveling and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as directed.
All as per item No 115 here-in-before but depth of bore hole exceeding 100 meter depth below ground level and upto 200 meter.
Supply & Fixing PVC pipe 6 kg/cm2 of size 180 mm dia heavy duty screwed and socketed type to borewell confirming to IS complete all as specified and directed.Make : Sudhakar or equivalent as approved by GE.
Supply & Fixing PVC pipe 6 kg/cm2 of size 250 mm dia heavy duty screwed and socketed type to borewell confirming to IS complete all as specified and directed.Make : Sudhakar or equivalent as approved by GE.
Supply and rreplace Non return valve 50 mm dia made of brass complete all as directed
Srinivasa Consructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .