Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-Finance | L1 | Accepted-Finance Lowest Rate | |
| 2 | L2₹21.5 L+₹1.0 L (5.14%)Rejected-Finance | L2 | Rejected-Finance Higher Rate | |
| 3 | L3₹21.7 L+₹1.2 L (6.10%)Rejected-Finance | L3 | Rejected-Finance Higher Rate |
| Sl No | Description | Qty | Unit | ARGHYA BHATTACHARYA L2 | KALPANA BHATTACHARJEE L3 | M/S MANIK KUMAR GHOSH L1 |
|---|---|---|---|---|---|---|
| 1.00SUB HEAD -1 SITC of Cocealed split type AC | ||||||
| 1.01Supplying, Installation, Testing and Commissioning of air cooled ducted split type air conditioning machine with each having a capacity and details as mentioned below suitable for operation on R 32/R-410A /R-407 Green refrigerant comprising of Scroll type compressor hermatically sealed complete with automatic capacity, safety switches, lubrication system with min 5 year (OEM) warranty for both compressor and Printed Circuit Board (PCB) , Suitable capacity squirrel cage induction motor having class 'B' insulation suitable for operation on 415 + 10% volts, 50 Hz, A.C. supply for Blower motor, Necessary drive arrangement for blower motor, Matching Air cooled condenser with necessary fittings for refrigerant piping connections, necessary structural support for mounting condensers, Microprocessor based control panel complete with accessories, machine Isolation / disconnect switch, valves and accessories to inter connect compressor and condenser including pressure testing, vacuum. Necessary starters suitable for Indoor & outdoor unit complete with O/L ,U/V, phase reversal protection, single phase preventors i/c copper conductor control and power cable and drain pipe of suitable size and length etc complete as required. The total cooling capacity/heating capacity of tested unit shall have a capacity as per relevant IS code. | ||||||
| 1.02The lab testing reports as per IS: 8148 shall be submitted. from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per ISO/International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification as required. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Hitachi) Non Inverter | ||||||
| 1.03 | 3.0 TR (BEE 4 Star Rated) | 6 | Nos. | 1,19,752 ₹7,18,512 | 1,20,882 ₹7,25,292 | 1,12,974 ₹6,77,844 Lowest |
| 1.04 | 2.0 TR (BEE 4 Star Rated) | 7 | Nos. | 81,663 ₹5,71,641 | 82,433 ₹5,77,031 | 77,041 ₹5,39,287 Lowest |
| 2.00 | Supply and charging Refrigerant - R-32/R-410A/R407C | 25 | kgs | 1,850 ₹46,250 | 1,720 ₹43,000 | 1,404 ₹35,100 Lowest |
| 3.00Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | ||||||
| 3.01 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 110 | Rmt. | 562 ₹61,820 | 568 ₹62,480 | 531 ₹58,410 Lowest |
| 3.02 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 110 | Rmt. | 687 ₹75,570 | 694 ₹76,340 | 649 ₹71,390 Lowest |
| 4.00 | S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of aboove AC machines.
i) 2.5 sqmm, 3/4 core copper cable (FRLS type) (Make: polycab / finolex/KEI) (For Indoor Unit Connection) | 125 | RM | 275 ₹34,375 | 277 ₹34,625 | 259 ₹32,375 Lowest |
Tender Value
₹20.8 L
EMD Value
₹41,655
Closing Date
19 Aug 2026, 12:00 pmClosed
Executive Engineer Cooch Behar Electrical Division
Executive Engineer Cooch Behar Electrical Division Sunity Road, Circuit House Campus
SITC of AC Machine at different Ejlash and Judicial Magistrate Officer Chamber at Mekhliganj Sub Divisional Court Mekhliganj in the district of Cooch Behar.
2026_WBPWD_5017694_1
WBPWD/EE/CED/eNIT-29/2026-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
Mekhliganj
Please refer Tender documents.
6 documents required · 6 mandatory
₹41,655
Executive Engineer Cooch Behar Electrical Division
31 Aug 2026
31 Jul 2026
21 Aug 2026
31 Jul 2026
19 Aug 2026
7 Aug 2026
6 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SUB HEAD -1 SITC of Cocealed split type AC | |||||
| 1.01 | Supplying, Installation, Testing and Commissioning of air cooled ducted split type air conditioning machine with each having a capacity and details as mentioned below suitable for operation on R 32/R-410A /R-407 Green refrigerant comprising of Scroll type compressor hermatically sealed complete with automatic capacity, safety switches, lubrication system with min 5 year (OEM) warranty for both compressor and Printed Circuit Board (PCB) , Suitable capacity squirrel cage induction motor having class 'B' insulation suitable for operation on 415 + 10% volts, 50 Hz, A.C. supply for Blower motor, Necessary drive arrangement for blower motor, Matching Air cooled condenser with necessary fittings for refrigerant piping connections, necessary structural support for mounting condensers, Microprocessor based control panel complete with accessories, machine Isolation / disconnect switch, valves and accessories to inter connect compressor and condenser including pressure testing, vacuum. Necessary starters suitable for Indoor & outdoor unit complete with O/L ,U/V, phase reversal protection, single phase preventors i/c copper conductor control and power cable and drain pipe of suitable size and length etc complete as required. The total cooling capacity/heating capacity of tested unit shall have a capacity as per relevant IS code. | - | - | - | - |
| 1.02 | The lab testing reports as per IS: 8148 shall be submitted. from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per ISO/International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification as required. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Hitachi)
Non Inverter | - | - | - | - |
| 1.03 | 3.0 TR (BEE 4 Star Rated) | 6 | Nos. | 1.25 | ₹7.5 |
| 1.04 | 2.0 TR (BEE 4 Star Rated) | 7 | Nos. | 1.25 | ₹8.75 |
| 2 | Supply and charging Refrigerant - R-32/R-410A/R407C | 25 | kgs | 1.25 | ₹31.25 |
| 3Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | |||||
| 3.01 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 110 | Rmt. | 1.25 | ₹137.5 |
| 3.02 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | - | Rmt. | 1.25 | - |
| 4 | S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of aboove AC machines.
i) 2.5 sqmm, 3/4 core copper cable (FRLS type) (Make: polycab / finolex/KEI) (For Indoor Unit Connection) | - | RM | 1.25 | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tendernotice_2.pdf
PDF • 1.20 MB
BOQ_5088052.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .