Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.3 LAccepted-AOC OLD HASIMARA DISTT JALPAIGURI WEST BENGAL PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹47.5 L+₹2.1 L (4.66%)Rejected-Finance SUBHASINI TEA ESTATE HASIMARA PS JAIGOAN DIST ALIPURDUAR WB PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹47.5 L+₹2.1 L (4.72%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹49.2 L+₹3.9 L (8.56%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹50.1 L+₹4.7 L (10.4%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
9 May 2023, 6:00 pmClosed
GE(AF) HASIMARA
GE (AF) HASIMARA PO HASIMARA DIST ALIPURDUAR PIN 735215 (WB)
REPAIR/MAINT OF FLOOR INCLUDING TILING PLASTERING AND ALLIED WORKS IN BASRA AREA, REPAIR/MAINT OF FOOTPATH, HARD STANDING, APPROACH PATHS AND OTHER ITEMS IN DOMESTIC AREA, REPAIR/MAINT OF ROAD SIDE DRAINS, WING WALL, PARAPETS AND ALLIED WORKS
2023_MES_590089_1
C/8648/23-24/E8
Open Tender
Civil Works
Item Rate
210 days
GE(AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) HASIMARA
₹88,000
Yes
18 May 2023
18 Apr 2023
15 May 2023
18 Apr 2023
9 May 2023
2 May 2023
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 300x 200x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 10mm thick rendering in CM (1:4) including rendering back coat in CM (1:4), complete all as specified and directed.
M & L for joint free white non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed with white cement and pigment to match, laid over and including 15mm thick screed bed or bedding layer in CM (1:6), complete all as specified and directed.
M & L vitrified ceramic tiles, light shade, 10mm thick (square/rectangular) polished, area of each tile n.exc 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tile laid over and including 15mm thick screed bed or bedding layer in CM (1:6), complete all as specified and directed.
M&L for chequered cement concrete tiles 30cmX30cmX25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment, laid over and including screed bed or bedding layer of CM (1:6) 15mm thick, complete all as specified and directed.
Taking up or down 15mm dia GI steel tubing and connection including cleaning for refixing or removal to store, complete all as specified and directed.
S&F GI tubes 15mm dia medium grade with all fitting and fixed complete to walIs and ceiling or laid in floors, complete all as specified and directed.
Taking up or down GI tubing of 20mm bore and connections, including cleaning for refixing or removal to store, complete all as specified and directed.
S&F GI tubes 20mm dia medium grade with all fitting and fixed complete to walIs and ceiling or laid in floors, complete all as specified and directed.
S&F in repair vitreous china squatting pan, ‘orissa’ pattern, size 630x 450mm white, with integral foot rests, and lime concrete bedding etc. (excluding flushing cistern and flush pipe), complete all as specified and directed
S&F in repair 10 ltrs capacity low level, valve less PVC syphonic action type flushing cistern white with in let, ball valve, float and handle, complete all as specified and directed.
S & F in repairs, vitreous china wash basin, oval shape pastle, flat back of size 580 x 450mm excluding taps but including chain, plug & porcelain stopper, bracket, complete all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs,washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm, bowl size 410mm x 330mm x160mm, complete all as specified and directed.
Taking down cement plaster of any description on brick work/stone work incl raking out joints, hacking for key ,scrubbing down with water etc, complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar (1:3) on ceiling and soffits of staircase, waist slab or concrete, surface finished even and smooth without using extra cement, complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion over one coat of primer, complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion over one coat of 1mm thick wall care putty including finishing surfaces, complete all as specified and directed.
M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks, triple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I (1000 ltr capacity) including 20mm nipple suitable for HDPE water tank and ball valves high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed to 20mm bore pipe inculding dismantling of old water tank of any description, complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks, triple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I (500 ltr capacity) including 20mm nipple suitable for HDPE water tank and ball valves high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed to 20mm bore pipe inculding dismantling of old water tank of any description, complete all as specified and directed.
S&F in repair grating round 140mm size of PTMT (minimum weight 50 gms), complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15cm thickness, (below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed.
M & L for 100mm thick plain cement concrete (1:2:4), type B-2 (using 40mm graded crushed stone aggregate) as in hard standing, laid in bays, etc, finishing cement concrete surface even and smooth with out using extra cement, complete all as specified and directed.
M & L for 75mm thick plain cement concrete (1:2:4), type B-1 (using 20mm graded crushed stone aggregate) as in plinth protection, hardstanding etc, laid in bays, finishing cement concrete surface even and smooth with out using extra cement, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar, complete all as specified and directed
M&L for broken stone or boulders hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface, complete as specified and directed.
M & L for 100mm thick plain cement concrete (1:3:6), type C-2, (using 40mm graded crushed stone aggregate), as in sub base for flooring complete all as specified and directed.
M & L for 60mm thick, M-35 grade machine pressed pre cast concrete interlocking paver block (with grey cement and pigment) any shape and size confirming to IS- 15658-2006 , laid over and including 50mm thick sand filling under interlocking pavers, complete all as specified and directed.
M & L for machine pressed pre cast concrete interlocking paver block (with grey cement and pigment) any shape and size confirming to IS- 15658-2006 of 80mm thick, M-40 grade, complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, pillars etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100m, and disposal of unserviceable materials, debris and rubbish off to a distance not exceeding 100m complete all as specified and directed.
M & L for brick work with sub-class ‘B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6), complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete, surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M & L for plain cement concrete (1:2:4), type B-1 (using 20mm graded crushed stone aggregate) as in coping including necessary form work, complete all as specified and directed.
M & L for plain cement concrete type D-2 (1:4:8) (using 40mm graded crushed stone aggregate) as in foundation, filling or mass concrete, complete all as specified and directed.
M & L for 15mm thick plaster in cement mortar (1:4) n. exc. 1 Sqm each patch, on brick walls, finished even and smooth without using extra cement including taking down old cement plaster on brick walls, concrete surfaces, raking out joints, hacking for key, scrubbing down with water etc and finishingthe surface matching to existing colour finish, complete all as specified and directed.
Dismantling bricks (laid flat or on edge) laid, bedded and pointed in CM as in floors, channels, kerbs, aprons etc. (each layer), complete all as specified and directed.
M&L for bricks, laid flat with old size subclass 'B' bricks locally available best quality bricks and jointed in CM (1:6) and pointed in CM (1:3), complete all as specified and directed.
All as per item No 38 here-in-before but except bricks, complete all as specified and directed. Note :- Old serviceable bricks obtained from item No 37 shall be re used.
M&L for brickwork, laid on edge in floors with old size subclass 'B' bricks locally available, jointed in CM (1:6) and pointed in CM (1:3), complete all as specified and directed.
All as per item No 40 here-in-before but except bricks, complete all as specified and directed. Note :- Old serviceable bricks obtained from item No 37 shall be re used.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for like MH cover, drain pipe bed, hard standing, etc., reinforcement cut to facilitate demolition, complete all as specified and directed.
M&L for providing precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in cover slabs for manhole or for drains etc, complete all as specified and directed.
M & L for mild steel TMT bars 10mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as specified and directed.
M & L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed. (Note:- Only inner girth to be measured.
M & L for flush pointing to old brick work laid on edge in CM (1:3) including racking out joints in floors, surface channels, complete all as specified and directed.
M & L for flush pointing to old brick work laid flat in CM (1:4) including racking out joints in floors, surface channels, complete all as specified and directed.
Restringing and tightening of ACSR conductor of any size and type maintaining stranded sag including providing aluminium binding wire, jumpers LT over head lines with jumper clip, complete all as specified and directed. Note:- 1. Actual number of conductor and shortest distance between the poles will be measured and paid. No extra payment will be made to the Contractor for sag and jumper etc. However burnt /damaged jumpers will be replaced by the contractor of appropriate size without any extra cost. Note:- 2. Pole to pole shortest distance including all conductor and earth wire will be measured and paid.
M&L for trimming of tree branches up to 40mm girth along the alignment of LT/HT over head electric line which are touching or falling on ACSR conductor/poles or near by sub stns etc at any height from GL and making sufficient clearance (1.5m) from conductor and taking down the same on the ground carefully by avoiding the damage and removing to a distance n. exc 100m, complete all as specified and directed. Note :(i) Trimming of the branches/twigs on both sides of the conductor. (ii) Actual lenght of cutting will be measured. (iii) The distance as mentioned above will be maintained during contract currency period & same location can be measured twice in the currency of contract subject to atleast 3 months period between two triming.
S&F jumper wire spiral type insulated aluminium conductor 50 Sqmm suitable for low/high tension jumper wire with colour coding (Red,yellow,blue and black), complete all as specified and directed.
Material and labour for porcelain viereous white or brown shackle type insulator including galvanized mild steel straps, washers, insulator bolts, washers and nuts 550 volts grade, 50mm height 65mm dia and 9mm dia bolt size, complete all as specified and directed.
Material and labour for pin type porcelain vitreous, white or brown insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 50mm height, 65mm dia for 550 Volts grade, complete all as specified and directed.
S&F danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size, complete all as specified and directed.
Dismantling cross arms of MS channel or angle sections etc., complete all as specified and directed.
M&L for cross arms,bracing,supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers,welding,bending cold or hot,drilling holes for bolts,in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, complete all as specified and directed.
M&L for galvanaized steel wire 3.15 or 4mm dia in replacement of guard/earth wire on LT OH line, re-stringing, binding and clamping etc, complete all as specified and directed.
M&L for providing in replacement hexagonal/rectangular guard cradles fabricated with galvanized steel wire 3.15/4mm dia, complete all as specified and directed.
M&L for ACSR conductor of any size and any type in replacement all as directed on LT OH line including stringing, tightening, clamping and binding with insulators, complete all as specified and directed.
M&L for painting steel tubular poles, 7.5 meter in height above GL including cross arms & bracings on existing surface after cleaning and removing dust, rust & dirt and applying one coat of red oxide primer and two coats of aluminium paint, painting with black & white alternate strips of 30cm each externally from ground level up to 1.5 mtr with synthetic enamel paint (1st grade quality), numbering of pole and white wash on pole coping, complete all as specified and directed.
M&L for painting of PCC poles, 8.5/9 meter in height above GL including cross arms and bracings on existing surface after cleaning and removing dust, rust & dirt with one coat of primer and two coats of cement based paint, painting with black & white alternate strips of 30cm each externally from ground level up to 1.5 mtr with synthetic enamel paint (1st grade quality) and numbering of pole, complete all as specified and directed.
Supply and fix water proof junction box made from SMC/FRP sheet ready made of size 350 X 270 X 138mm with aluminium bus bar of 100 Amp capacity for RYB and half of neutral made in suitable size fixed inside the junction box with necessary supporting insulators fixed on hylem sheet /Insulating sheet ,MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete , entire assembly fixed to pole /Wall with MS clamp 25 X 5mm and nuts & bolts or inside the coping of pole/ post top including MCB SP6 Amp 10 Ka 240 V- 01 No with necessary size copper legs for connecting cables from junction box to fittings, complete all as specified and directed.
M &L for providing numbering on poles with letter and numbering indicating the pole numbers/area as directed using letters not less than 15 CM height on black white/circular/square back ground on PCC/steel tubular poles, complete all as specified and directed.
S&F in repair MCB SPN 6 to 32 Amp 10 KA, 'C' series, complete all as specified and directed.
S&F in repair MCB 63Amp 4 pole, 10 KA, 'C' series, complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation etc and getting out in soft/loose soil, complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 25cm thick, complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm dia conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed.
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 50mm dia conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed.
M&L galvanized iron tubing 40mm bore (light grade) with all fittings for protection of cables, laid in trenches, complete all as specified and directed. (Note:- Excavation and earth work shall be measured and paid separately)
Taking down/out unserviceable UG cables of any cross sectional area and connections including bricks, GI pipes, etc of any descriptions, laid in trenches and/or fixed with walls/poles, complete all as specefied and directed.
M&L for XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross- sectional area 35 sqmm 3.5 core, complete all as specified and as directed. (Note : Excavation and earth work shall be measured and paid separately under respective items)
All as per item No 08 above but cross sectional area 120 Sqmm 3.5 core, complete all as specified and as directed.
M & L earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 25 x 4mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20mm graded crushed stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 40mm dia light grade GI pipe for lead protection in & including alternate layers of char coal dust and common salt complete all as shown in electrical plate No 5 and connected to earthing test point all as specified and indicated including testing on completion and marking of description of earthing on GI plate grouted on the earth chamber complete all as specified and directed. Note : Cost of GI Strip in suitable dia HDPE pipe and MS Clamp from Earthing to LT Panel shall be included in the quoted rate.
M & L for horizontal boring (manual method) under the road below 1mtr from the road surface and dia of hole not exc 100mm, with out damaging the existing road, getting out and disposal of soil to a distance not exceeding 50m from the site of work, complete all as specified and directed.
Supply, fabricating, installing, testing and commissioning of outdoor type LT bus bar box of size not less than 900 mm (L) x 900mm (b) x 450mm (d) of suitable size factory fabricated, cubical panel, floor mounted double door, dust and vermin proof CPRI approved made out of 3.15mm thick CRCA sheet mounting on 40x40x5mm Angle iron supports at the base duly painted with synthetic enamel paint and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper bus Bar strip 40mm x 10mm for three phase 4 wire 415 Volts, 50 Hz, AC supply including suitable size cable glands, lugs etc, proper arrangement for ventilation, complete all as specified and directed.
Supply and fixing sheet metal enclosure for double door MCB DBs, phosphatised, powder coated, triple pole & neutral (TPN), suitable for 6 way, 415 volts, IP 43 & IK 09 with metal door fixed on wall with din rail, neutral and earth bar, in proper position, complete all as specified and directed.
Supply & fixing Isolator four pole capacity 100 Amps, 415 Volts fixed in proper position including connecting wire as per site requirement, complete all as specified and directed. Make : Legrand/L & T / Hager or equivalent
Supply & fixing MCB single pole and neutral (SPN) of capacity 40 to 63 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position, complete all as specified and directed. Make Cat Part No 4086 18 to 4086 20 of legrand/equivalent of makeHavells/L&T/ ABB
Supply & fixing MCB single pole SP of capacity 6 to 32 Amps, 240 Volts, breaking capacity 1 0 KA, ‘C’ series, fixed in proper position, complete all as specified and directed. Make Cat Part No 4085 87 to 408595 of Legrand/equivalent of makeHavells/L&T/ ABB
M&L for sub main wiring with two run of 4 Sqmm single core PVC insulated, unsheathed multistranded copper conductor cable FRLSH 1100 Volt grade, drawn through and including PVC casing caping (ISI marked) including all accessories and one run of 4 Sqmm single core PVC insulated unsheathed FRLSH copper earth continuity conductor including taking down old sub main wiring, complete all as specified and directed. Note(i) : Two runs of 4 Sqmm single core cable with one run of earth continuity conductor including PVC casing caping accessories shall be measured and paid as one length).. Note(ii): An amount of Rs.32581.00 on account of credit schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S. VINITA CONSTRUCTION
M/S I P GROUP
M/S BISHAL ENTERPRISES
M/S SARKAR ELECTRIC
M/S BIJAY KUMAR SHIVA
M/S SANMILAN NANDI
M/S MANODEEP CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .