Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹27.1 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹28.6 L+₹33,478.40 (1.18%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹29.5 L+₹1.2 L (4.41%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹31.1 L+₹2.8 L (9.74%)Rejected-Finance | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹33.1 L+₹4.8 L (17.0%)Rejected-Finance | L-5 | Rejected-Finance L-5 |
| Sl No | Description | Qty | Unit | M/S Anand Enterprises L3 | Singh Associates L6 | NAVYUG VYAPARI L2 | laxmi enterprises L1 | PARAS ENTERPRISES L5 | M/S Parshant Associates L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting out, complete all as specified and directed. | 226.8 | Cum | 80 ₹18,144 Lowest | 150 ₹34,020 | 90 ₹20,412 | 99 ₹22,453.2 | 100 ₹22,680 | 99 ₹22,453.2 |
| 2.00 | Returning, filling, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. | 126 | Cum | 20 ₹2,520 | 50 ₹6,300 | 40 ₹5,040 | 20 ₹2,520 | 10 ₹1,260 Lowest | 35 ₹4,410 |
| 3.00 | Removing of surplus excavated soil to distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. | 100.8 | Cum | 20 ₹2,016 Lowest | 100 ₹10,080 | 40 ₹4,032 | 99 ₹9,979.2 | 100 ₹10,080 | 35 ₹3,528 |
| 4.00 | Material and labour for sand cushioning for XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and gently punned down to a thickness of 10 cm complete all as specified and as directed. | 90.72 | Cum | 300 ₹27,216 | 1,450 ₹1,31,544 | 350 ₹31,752 | 299 ₹27,125.28 Lowest | 350 ₹31,752 | 400 ₹36,288 |
| 5.00 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm, complete all as specified and directed. | 6,720 | Each | 5 ₹33,600 Lowest | 30 ₹2,01,600 | 7 ₹47,040 | 5 ₹33,600 Lowest | 15 ₹1,00,800 | 6 ₹40,320 |
| 6.00 | Supply and Laying,Connecting and testing in replacement of old u/s XLPE, cable, insulated, armoured, heavy duty, electric cable with aluminium conductor 1100 Volt grade cross sectional area 185 Sqmm 3.5 core, complete all as specified and directed. | 100 | RM | 600 ₹60,000 | 1,600 ₹1,60,000 | 600 ₹60,000 | 399 ₹39,900 Lowest | 850 ₹85,000 | 650 ₹65,000 |
| 7.00 | All as per item No 06 above but Size 95 sqmm 3.5 core. | 200 | RM | 500 ₹1,00,000 | 800 ₹1,60,000 | 300 ₹60,000 | 299 ₹59,800 Lowest | 475 ₹95,000 | 550 ₹1,10,000 |
| 8.00 | All as per item No 06 above but Size 70 sqmm 3.5 core. | 200 | RM | 400 ₹80,000 | 700 ₹1,40,000 | 220 ₹44,000 | 199 ₹39,800 Lowest | 375 ₹75,000 | 450 ₹90,000 |
| 9.00 | All as per item No 06 above but Size 50 sqmm 3.5 core. | 100 | RM | 300 ₹30,000 | 500 ₹50,000 | 200 ₹20,000 | 199 ₹19,900 Lowest | 275 ₹27,500 | 350 ₹35,000 |
| 10.00 | All as per item No 06 above but Size 35 sqmm 3.5 core. | 100 | RM | 200 ₹20,000 | 350 ₹35,000 | 150 ₹15,000 | 149 ₹14,900 Lowest | 165 ₹16,500 | 250 ₹25,000 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
31 Jul 2025, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR/MAINT/REPLACEMENT OF LOW VOLTAGE PANELS, KIOSK BOX, AIR BREAKER SWITCH, DG SETS, AMF PANELS, SECURITY LIGHTS AND OTHER MISC E/M ITEMS AT AF STN FARIDABAD UNDER AOR OF GE (AF) FARIDABAD
2025_MES_719722_1
GE (FBD)/AF-T-49/2025-2026
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Faridabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹94,000
Yes
6 Oct 2025
10 Jul 2025
4 Aug 2025
10 Jul 2025
31 Jul 2025
17 Jul 2025
Amount
Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting out, complete all as specified and directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of surplus excavated soil to distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning for XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and gently punned down to a thickness of 10 cm complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm, complete all as specified and directed.
Supply and Laying,Connecting and testing in replacement of old u/s XLPE, cable, insulated, armoured, heavy duty, electric cable with aluminium conductor 1100 Volt grade cross sectional area 185 Sqmm 3.5 core, complete all as specified and directed.
All as per item No 06 above but Size 95 sqmm 3.5 core.
All as per item No 06 above but Size 70 sqmm 3.5 core.
All as per item No 06 above but Size 50 sqmm 3.5 core.
All as per item No 06 above but Size 35 sqmm 3.5 core.
All as per item No 06 above but Size 16 sqmm 4 core.
All as per item No 06 above but Size 10 sqmm 4 core.
Boring holes under road, pavement, Hard Standing etc by trenchless technology using ultra Sound technique and necessary machine with 100 mm dia HDPE Pipe, PN 10 complete all as specified and as directed.
Supply, laying and fixing in position in replacement of 80 mm dia. GI pipe 'light grade' fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches duly painted with two coat of black metallic paint after a primer coat of red oxide, complete all as Specified and directed.
All as per item No 14 above but 50 mm dia.
All as per item No 14 above but 40 mm dia.
M&L for cable end termination kit out door, heat shrinkable type suitable for XLPE/ PVC cables of size 6 Sqmm to 16sqmm 4 core core with working voltage 1100 volts including necessary excavation returning, filling & removal of surplus soil complete all as specified and directed.
All as per item No 17 above but Size 25-35 sqmm 4 core.
All as per item No 17 above but Size 50-95 sqmm 3.5 core.
All as per item No 17 above but Size 120-185 Sqmm 3.5 core.
M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 6 Sqmm to 16 Sqmm 4 core with working voltage 1100 volts, complete all as specified and directed.
All as per item No 21 above but Size 25-35 sqmm 4 core.
All as per item No 21 above but Size 50-95 sqmm 3.5 core.
All as per item No 21 above but Size 120-185 Sqmm 3.5 core.
S&F in replacement of MCCB, 4 pole, 415 volts, fixed type, 400 Amps with breaking capacity 36KA, including taking out old U/S complete all as specified and directed.
S&F in replacement of MCCB, 4 pole, 415 volts, fixed type, 315 Amps with breaking capacity 36KA, including taking out old U/S complete all as specified and directed.
S&F in replacement of MCCB, 4 pole, 415 volts, fixed type, 250 Amps with breaking capacity 25KA, inclduding taking out old U/S complete all as specified and directed.
S&F in replacement of MCCB, 4 pole, 415 volts,fixed type, 200 Amps with breaking capacity 16 KA, including taking out old U/S complete.all as specified and directed.
S&F in replacement of MCCB, 3 pole, 415 volts, fixed type, 160 Amps with breaking capacity 36KA, including taking out old U/S complete all as specified and directed.
S&F in replacement of MCCB, 3 pole, 415 volts, fixed type, 125 Amps with breaking capacity 36KA, including taking out old U/S, complete one all as specified and directed.
S&F in repacement of MCCB, 3 pole, 415 volts, fixed type, 63 Amps with breaking capacity 16 KA, including taking out old U/S complete.all as specified and directed.
S&F sheet metal enclosures DB Double door Vertical distribution type, 08 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assembly with earthing terminal as provided by manufacturer complete as specified and directed. Note : - MCCB shall be measured and paid separately
S&F in replacement of old u/s MCB, SP 6 to 32 amps, 230 Volt, complete all as specified and directed.
S&F in replacement of old u/s Contactor, (4 Pole AC & DC Control) operational current AC1,160 Amps,poles composition- 4NO,DC control ref-LP1D80004 of TC complete all as specified and as directed.
S&F in replacement of old u/s Contactor, (4 Pole AC & DC Control) operational current AC1,125 Amps,poles composition- 4NO,DC control ref-LC1DT125A of TC complete all as specified and as directed.
S&F in replacement of old u/s MNX 18, 3 pole contractor, 2 NO+ 2 NC, 415 volts AC, conforms to IS/IEC 60947 - 4 -1, in existing model and make including after taking out old unserviceable complete all as specified and as directed.
S&F in replacement of old u/s MNX 95, 3 pole contractor, 2 NO+ 2 NC,415 volts AC, conforms to IS/IEC 60947- 4 -1, in existing model and make including after taking out old unserviceable complete all as specified and as directed.
S&F in replacement of MNX 70, 3 pole contractor, 2 NO+ 2 NC, 415 volts AC, conforms to IS/IEC 60947 - 4 -1, in existing model and make including after taking out old unserviceable complete all as specified and as directed.
S&F in replacement of MN contactor 18 Amps in existing model and make including after taking out old unserviceable complete all as specified and as directed.
M&L for servicing of volatge stabilizer auto servo controlled on balanced type 3 Phase naturally cooled of capacity 100 to 160 KVA, by disconnecting the LT cables and draining out oil complete and taking out the core and checking the continuity and insulation values of all three phases, re-insulating if required and inspecting and replacing the PCB and servicing of breaker, removing and cleaning the sludge from the tank, re-filling the oil after filtering by using online centrifuge machine and obtain the di-electric strength of oil not below 60 KV at 2.5 mm gap including testing of volatge stabilizer by re-connecting the disconnected cables and calibrating complete all as specified and as directed. Note:- 1. The rate shall also deemed to be included the rate for Technician, Electrician and labours. 2. Spare parts shall be measured and paid separately in following item as 'Supply only'.
Supply only Spring loaded finger for servo stablizer complete all as specified and as directed.
Supply only Microproccessor Based eletronic control board complete all as specified and as directed.
M&L for repairing, servicing and replacement of LT panels unserviebale part including complete accesories such as partialy open door, door breakers , Unsv Al bus bar , Unsv locking arrangement, repairing of LT Panel legs, welding work , necessary PCC work, Excavation, removal, retruning filling including disconnection and reconnection of cables, of any size, any capacity, complete all as specified and directed by Engr-in-Charge.
Removing all connections from LT panel having feeders upto 04 Nos ( Total of incoming and outgoing), any capacity, indoor or outdoor type, fpr repairs/ servicing, Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the panel as per standard engineering pactice complete all as specified and directed Note:- Items required for replacement shall be provided against respective items separately.
Removing all connections from LT panel having feeders above 04 Nos upto 08 Nos ( Total of incoming and outgoing) , any capacity, indoor or outdoor type, fpr repairs/ servicing. Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the panel as per standard engineering pactice complete all as specified and directed Note:- Items required for replacement shall be provided against respective items separately.
M&L for Painting of LT panel of size 600x600x300mm (approx) after removing old dust partical,oily porytion by rubbing with sand paper with spary pump, and writing /digital printing, Capacity Descripton, date of installation,etc as direction by Engr-in-cahrge.
M&L for Scraping of old paint from two pole/ four pole structure without removing accessories and preparation of surfaces for repainting. Repainting the poles with one coat of alternative green and white strips of 30 cm each upto 1.5 mtr height using synthetic enamel paint, marking the pole Number with black enamel paint and repainting the remaining Iron parts i.e. cross arms, supporting angles, XPM jali, clamps, GI bkt, etc, steel pole above 1.5 mtr height by applying one coat of aluminium paint or for PCC pole with snowcem of approved color all as required at site or directed.
Supply and fixing as in repair / replacement motorised changeover switches of 315 A , 4P (Four Pole) , 415 V, surface mounted type with side handle operation including bridging bars & external handle with swtich is in ON position, OFF position and other DG/Sources ON position (three position ) complete including electrically connection and taking out unserviceable changeover swtich, complete all as specified and directed.
S&F in replacement of UNSV Aluminum thimbles of size 10sqmm to 70sqmm as per site requirements, complete all as specified and directed.
S&F in replacement of UNSV Aluminium thimbles of size 95Sqmm to 185sqmm as per site requirements, complete all as specified and directed.
M&L for danger notice plate of 1.6mm thick Mild steel sheet, vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT, 20x15 cm size all as specified and directed.
Supplying and fixing of 25 mm dia. PVC conduit pipe along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete as specified and directed.
M&L for Dehydration including filteration and cleaning of transformer oil by centifugal dehydration machine till to achieve Di-electric strength 50 KV at 2.5 mm gap testing of sample before and after dehydration and filteration all as specified and directed by Engineer-in-Charge. NOTE:- Contractor shall be arrange the dehydration machine and testing kit without any extra cost to the deptt. Test report to be submitted after completion of job.
Supply & Filling /pouring of transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and as directed. NOTE:- Dielectric strength test shall be carried out at site before pouring/ filling in transformers in the presence of Engr-in-Charge on the site.
M&L for earthing with steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less tha 1.5 mtr deep below normal ground level connected to galvanized iron strip size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after wlding of GI strip to earth electrode to the full length of earth plate, 40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30x30 cm made of RCC type B-1,1:2:4 with suitable handle, angle iron frame made of angle iron of size 40x40x4mm, adequate quantity of charcoal dust and salt layers all around the earth plate and filling of vegetables soil to the remaining 10% removal of surplus soil and retruning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and complete all as specified and directed by Engineer-in-Charge.
M&L for Design, development, supply commissioning and testing burnished metallic brown 99.99% pure copper material specially developed for earthing purpose 'T' point terminal exothermic/ nut bolt/ breezing, ground tubular effective chemical earthing (CPRI tested for 25KA current capacity for LT line ) highly anti-corrosive long life eletrode with and including adequate protective coating to withstand servere weather condition in the earth pit of the standard size comprising of 40 mm dia & 3m long copper rod as primary conductor and hollow copper tube of 80 mmx 3 m long with a losing base plate of 80 mm secondary conductor to install with suitable connecting terminal coforming to IS 3043 1987 specification highly conductive packing material to be filled in earth pits for providing uniform low resistive anti-corrosive, hygroscopic medium around the earth system for improving the efficiency of current dissipation with crystalline conductive mixture CCM 25 kg per bag sufficient quantities required at site complete RCC earthing pit cover material and labour complete bfc compound specified and as per IEC 62561 acceptance chemical test Leaching, sulphur determination, corrosion, resistivity along with CPRI and chemical compound test report Note :- 1. Excavation / drilling hole in hard rock is included in the rate quoted included and T&P. 2. Min. resistance for earthing pit shall be less than 1 ohm. 3. Drilling or earth work shall be included in the overall cost quoted by the contractor.
S&F in replacement of copper strip 20mm x 3.15 mm complete with insulators and fixing screws etc for roof/wall above ground level including removing u/s strips, complete all as specified and directed.
S&F in replacement of aluminium strip 25 mm x 4 mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed.
Supply and fix single pointed air termination aluminium rod,12 mm dia, 300 mm long, complete all as specified and directed.
S&F in replacement of porcelain strip holder on wall and roof of suitable size including removing broken u/s one complete all as specified and directed.
M&L for 32 mm GI pipe 'light grade' of 1.3 mtr piece fixing in PCC cubical and complete connection of existing air termination rod complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping and necessary form work, weathering slightly rounded or chamfered angles and throating etc, complete all as specified and directed.
M&L for General Servicing of DG set 200 KVA, comprising of Cleaning & greasing of the parts, Tappet setting as per standard, Fan belt, tensioner pulley and lever adjustments, Tightening of all the nuts, bolts and clamps, Testing & checking of AC & DC Wiring, Self & Charging Alternator cleaning and testing, checking of working & minor fault removal, Checking of Supply & return fuel pipes from fuel tank to engine, Cleaning of hydraulic governer, Cleaning of radiator complete set.Checking of FIP timing by Fuel cut off method including Transportation, Labour charges & minor material required for servicing etc. as required complete all as specified and directed by Engineer-in-Charge. Note :- 1. Servicing through OEM authorised representative or service Engineer from the manufacturer only. 2. Cost of unserviceable items will be measured and paid seperately under relevant items.
All as per item No.66 above but capacity of DG set 160 KVA
All as per item No.66 above but capacity of DG set 100 KVA
All as per item No 66 above but capacity of DG set 82.5 KVA
All as per item No.66 above but capacity of DG set 62.5 KVA
All as per item No.66 above but capacity of DG set 25 to 40 KVA
Supply only Element lub oil filter Cartrige complete all as specified and directed.
Supply only fuel filtter Cartage complete all as specified and directed.
Supply only Pre Filter Assembly complete all as specified and directed.
Supply only Air Filter for Set complete all as specified and directed.
Supply only seal 'O' ring complete all as specified and directed.
Supply only genuine Engine oil complete all as specified and directed.
Supply only super plus coolent complete all as specified and directed.
Supply only distilled water complete all as specified and directed.
Supply only Battery terminals, lugs, bolts complete all as specified and directed.
Supply only Battery leads copper conductor multi-wired 35 Sqmm.
Supply only Hinges for DG set door of any size, any type as required on site.
M&L for Dismantling the radiator and fan from the engine for cleaning of copper tubes and cooling fins by de-scaling solution and using air compressor, soldering on leakage, patch work and re-assembling the radiator and fitted with DG set properly including replacement of radiator hose pipe with clamps and bolt/nut with washer, leak check and pressure testing including transporting to repair workshop and bringing back for upto 62.5 KVA all as directed
All as per item No 83 above but capacity from 82.5 KVA upto 200 KVA
S&F in replacement and testing of radiator assembly of DG Set 32.5 KVA, complete all as specified and as directed.
S&F in replacement and testing of radiator assembly of DG Set 160 KVA, complete all as specified and as directed.
S&F in replacement of low lube oil pressure sensor upto 160 KVA DG Set, complete all as specified and as directed.
S&F in replacement of Water Pump of Radiator suitable for DG set Radiator up to 62.5 KVA, complete all as specified and as directed.
All as per item No 88 above but capacity from 82.5 KVA upto 200 KVA
M&L for removal & replacement of fly wheel gear ring suitable for upto 62.5 KVA DG set connection & testing, complete all as specified and as directed.
All as per item No 90 but capacity from 82.5 KVA upto 200 KVA.
M&L for Removal & replacement of thermostat suitable for upto 62.5 KVA DG set connection & testing complete all as specified and directed.
All as per item No 92 above but capacity from 82.5 KVA upto 200 KVA.
Supply and fixing in replacement of AVR for DG set having capacity 62.5 KVA, complete all as specified and as directed.
All as per item No 94 above but capacity from 82.5 KVA upto 200 KVA.
Supply, fixing and testing for smoothing fuctioning Fan Belt suitable for DG set up to 62.5 KVA, complete all as specified and as directed.
All as per item No 96 above but capacity from 82.5 KVA upto 200 KVA,
Supply and fixing in all type of hose pipe with clamps, over flow pipe, copper tube fuel supply pipe, etc with clip and complete fittings suitable for DG set upto 62.5 KVA, complete all as specified and as directed.
All as per item No 98 above but capacity from 82.5 KVA upto 200 KVA.
S&F for fuel hose pipe from fuel filter to fuel pump for DG set upto 62.5 KVA, complete all as specified and as directed.
S&F for fuel pipe from fuel tank to fuel filter for DG Set 82.5 KVA to 200 KVA, complete all as specified and as directed.
Supply and fixing mounting rubber bushing set of 6 for existing generator, complete all as specified and as directed.
S&F of under/over voltage relay 3 phase 415V for DG set of capacity upto 200 KVA, complete all as specified and as directed.
Supply & Fixing in replacement of Battery Charger 12V DC, 5 Amp of Autocut Electrical Battery Charger Unit SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Rectifier Unit etc suitable for smoothing functioning of DG set as required on site, complete all as specified and as directed.
All as per item No 104 above but capacity Battery Charger 24V DC, 10 Amp.
Supply & Fixing of DC 12V Stop Solenoid Coil suitable for DG Set, complete all as specified and as directed.
Supply & Fixing of DC 24V Self Solenoid Coil suitable for DG Set, complete all as specified and as directed.
Supply and replacement of Battery 12 Volt 100 AH suitable DG set, complete all as specified and as directed.
Supply and replacement of Battery 12 Volt 180 AH suitable DG set, complete all as specified and as directed.
M&L for repairing of self starter of DG set capacity 12 Volts including transporting upto workshop to carry out necessary replacement of burnt copper winding with new copper winding/ coil of existing gauge from rotor and stator coil, cleaning of slots, dryings varnishing and proper insulating to winding, complete all as specified and as directed.
All as per item No 110 above but capacity 24 Volts.
M&L for carrying out complete over hauling/servicing of DG set panel /AMF panel/control panel including checking and rewiring of faulty electrical circuit using 1.5 Sqmm FRLS copper conductor for DG set of any type/make /capacity and making all electric connection and testing for smooth operation, complete all as specified and as directed.
Labour only for rectification of fault in AMF panel of DG set and testing on load ranging from 25 to 200KVA, complete all as specified and as directed.
M&L in replacement of relay of AMF panel, complete all as specified and as directed.
M&Lin replacement of display panel of AMF suitable for DG set rating 25 to 62.5 KVA along with all connections and push buttons for mode change and start stop button, complete all as specified and as directed.
M&L in replacement of display panel of AMF suitable for DG set rating 82.5 to 200 KVA along with all connections and push buttons for mode change and start stop button, complete all as specified and as directed.
S&F in replacement of IOPS Module digital display controller unit suitable for exisitng DG Set, complete all as specified and as directed.
S&F in replacement of MCCB, 3 pole, 415 volts, fixed type, 200 Amps with breaking capacity 36KA, including taking out old U/S complete all as specified and directed.
S&F in replacement of MCCB, 3 pole, 415 volts, fixed type, 250 Amps with breaking capacity 36KA, including taking out old U/S complete all as specified and directed.
S&F in replacement of MNX 95, 3 pole contractor, 2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 - 4-1, in existing model and make including taking out old unserviceable one, complete all as specified and as directed.
S&F Contactor, (4 Pole AC & DC Control) operational current AC1,160 Amps, poles composition - 4NO,DC control ref-LP1D80004 of TC complete all as specified and as directed.
S&F Contactor, (4 Pole AC & DC Control) operational current AC1,125 Amps, poles composition- 4NO,DC control ref-LC1DT125A of TC complete all as specified and as directed.
S&F in replacement of MNX 18, 3 pole contractor, 2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 - 4-1, in existing model and make including taking out old unserviceable one, complete all as specified and as directed.
S&F in replacement of MNX 70, 3 pole contractor, 2 NO+ 2 NC, 415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including taking out old unserviceable one, complete all as specified and as directed.
S& F Panel LED indication lamps (R/Y/B) complete all as specified and as directed.
S&F Rotary switch of existing make, complete all as specified and as directed.
S&F in replacement of digital volt meter, 415 volts, including after taking out old unserviceable one all as specified ans as directed by Engr-in-Charge.
S&F in replacement of digital Ammeter, 415 volts grade,100 Amps rating, including and after taking out old unserviceable one all as specified and as directed by Engr-in-Charge.
M&L for attending of any breakdown of standby power supply in any location, wherever required round the clock, rectify the fault and restore the standby supply within three hours after receipt of complaint of any nature i.e engine, alternator, control panel/AMF panel etc complete all as directed by Engineer-in-Charge. Note- (i) The cost of replaced spare parts will be paid and measure seperatly. (ii) If complaint is not attended by contractor with in five hours the penalty of Rs 500/- per hour to be imposed and amount of penalty will be deducted from RAR. (iii) The cost of transportation (to and from) for all kind of necessary equipment /T&P shall be arranged/brought by contractor to complete the job at site or at E/M Yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically so contractor to specify the telephone/mobile number who will receive the complaint round the clock.
M&L for servicing/testing of APFC (Automatic Power Factor Control) panel including checking of all internal connections and replacement of spares if required complete all as as specified and as directed. Note - Spares to be measured and paid separately
S&F in capacitor 3 phase, 5 KVAR complete all as specified and as directed.
S& F in capacitor 3 phase, 10 KVAR complete all as specified and as directed.
S& F in capacitor 3 phase, 25 KVAR complete all as specified and as directed.
S& F in capacitor 3 phase, 2 KVAR complete all as specified and as directed.
S& F in capacitor 3 phase, 3 KVAR complete all as specified and as directed.
Supply and install reactive power manager in existing APFC panel, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of Onload Changeover switch 400 Amp, 4 pole ,415 V,50 Hz in sheet metal enclosure complete all as specified and directed by Engineer-in-Charge.
M&L for welding each canopy door to the outer unit for proper closing and opening including hinges and repainting complete all as specified and directed by Engineer-in-Charge.
M&L spray gun painting of generator upto 62.5 KVA in existing colour with smooth finishing, compete all as specified and directed by Engineer-in-Charge.
M&L spray gun painting of generator 82.5 KVA upto 160 KVA in existing colour with smooth finishing, compete all as specified and directed by Engineer-in-Charge.
M&L spray gun painting of generator 200 KVA in existing colour with smooth finishing, compete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar, compete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Earth test box made of powder coated, 3.15 mm thick, CRCA sheet, 20 cm x 20 cm x 10 cm size conforming to CPRI approved and IP-65 protection class,right hinge openable type including mounting arrangement such as making hole in wall,providing MS clamp,nut,bolt etc, compete all as specified and directed by Engineer-in-Charge.
M&L for High quality powder coating on electric panels (Cubical) installed at different places with synthetic enamel paint of suitable colour including and after scrubbing all body surface to get all foreign particles removed off, applying one coat of metal primer by disconnecting, removal of all accessories like bas bar, CTs,MCCBs and all wirings,equipments and refix with new Gun metal nut, bolt and washer complete with new copper lead wiring, compete all as specified and directed by Engineer-in-Charge.
S&F in replacement of wall mounted TPN busbar chamber factory made with busbar of current rating 400 Amp, 415, 4 way, complete all as specified and directed by Engineer-in-Charge.
S&F rubber insulation mat of size 1.8 mtr x0.9mtr wide 2mm thick green / blue colour ISI marked embossed, for up to 3.3 KV complete all as specified and directed by Engineer-in-Charge.
Taking down unserviceable street light fitting from fixed type High mast pole 16 to 25 mtrs LED Street Light fitting/Flood light Fitting of any size from the pole/bldg and kept in safe custody for refixing or for schedule of credit to contractor, complete all as specified and directed by Engineer-in-Charge. Note : All T&P i.e ladder, Tools, Safety glooves etc will be provided by the contractor without any extra cost
Refixing after repairing and reconnecting up complete to fixed type high mast pole 16 to 25 mtrs LED street light/Flood light fitting after rectification of defects in wiring of the fitting, including replacement of holders, PVC connector, ballast, ignitor, condessor and lamp and making electric connection with PVC unsheathed wire with old or new conductor with OH line or Bus bar box complete all as specified and directed by Engineer-in-Charge. Note : All T&P ie ladder, Tools, Safety glooves etc will be provided by the contractor without any extra cost
Taking down unserviceable street light fitting/LED Street Light fitting/Flood light Fitting of any size upto 11 mtrs, from the pole/bldg and kept in safe custody for refixing or for schedule of credit to contractor complete all as specified and directed by Engineer-in-Charge. Note : All T&P i.e ladder,Tools,Safety glooves etc will be provided by the contractor without any extra cost
Refixing and reconnecting up complete LED street light/Flood light fitting after rectification of defects in wiring of the fitting in an including replacement of holders, PVC connector, ballast, ignitor, condessor and lamp and making electric connection with PVC unsheathed wire with old or new conductor with OH line or Bus bar box complete all as specified and directed by Engineer-in-Charge. Note : All T&P i.e ladder, Tools, Safety glooves etc will be provided by the contractor without any extra cost
S&F in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in replacement of LED street light fitting 45 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessories complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in replacement of LED street light fitting 60 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessories complete all as specified and directed by Engineer-in-Charge.
S&F LED flood light in replacement of luminarie 70 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection acomplete all as specified and directed by Engineer-in-Charge. Note : All T&P i.e ladder, Tools, Safety glooves etc will be provided by the contractor without any extra cost to height upto 25 mtr.
S&F LED flood light in replacement of luminarie 120 W with high pressure die-cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed by Engineer-in-Charge. Note : All T&P i.e ladder, Tools, Safety glooves etc will be provided by the contractor without any extra cost to height upto 25 mtr.
S&F LED flood light luminarie 200 W with high pressure die-cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed by Engineer-in-Charge.
Supply and fix single phase driver for LED street light / flood light of 45 to 200 watt capacity and compatible with existing street light/ flood light any type / any rating complete all as specified and directed by Engineer-in-Charge.
S&F in replacement street light GI pipe bracket of 50 mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed by Engineer-in-Charge.
M&L for scrapping of surface of steel tubular poles of any size with emery paper and painting of pole one coat of primer and two coats of silver colour(Alimium paint) paint including writing pole No on yellow colour with 30cm strip upto 1.5 Mtr height from ground level complete all as specified and directed by Engineer-in-Charge.
Supply and fixing automatic street light pre-wired switch using nature switch for automatic switching of street light based on lux level of nature light.THE SENSOR (NATURE SWITCH) alongwith power contactor for 25 KW 3 phase, MCB pole/wall mountable enclosure made of rust proof electric shock proof terminal proof and FR grade special moulding compound junction box conforming to IP54 with all other accessoried i.e lugs cable connedtion etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement non-metallic junction box/street light box with three phase aluminium bus bar of suilable for 415 Volt , 50 Hz electric supply conforming to IP65 wall / pedestral mounted and including MCB SPN 06 Amps complete all as specified and directed by Engineer-in-Charge.
M&L for servicing and maintenance of High mast pulley and GI wire rope system oiling, greasing etc for smooth functioning of the lowering mechanism complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of 0.5 HP to 1 HP motor of high mast complete all as specified and directed by Engineer-in-Charge.
NAVYUG VYAPARI (BID ID -3378242)
M/S Anand Enterprises (BID ID -3373034)
M/S Parshant Associates (BID ID -3378653)
PARAS ENTERPRISES (BID ID -3377834)
Singh Associates (BID ID -3377037)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .