Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC ERODE 638 002 | ERODE | TAMIL NADU | 638002 | ₹24.6 L Quoted ₹25.2 L | L1 | Accepted-AOC Provision of 100 KVA Diesel Generator Sets with AMF Panel arrangements to the Mordhana Dam in Vellore District. |
| 2 | L2₹26.1 LRejected-Finance NO 218 LAKSHMANA RAO STREET PUDHUPETTAI KRISHNAGIRI 635 001 | KRISHNAGIRI | KRISHNAGIRI | TAMIL NADU | 635001 | ₹26.1 L | L2 | Rejected-Finance Among the 2 bidders Highest rate quoted by Senthil Kumar |
| Sl No | Description | Qty | Unit | S.Senthil Kumar L2 | R SURESHMANI L1 |
|---|---|---|---|---|---|
| 1.00 | Supply , Testing Commissioning and Handing over of 1no 100 KVA Diesel Generator set(Make Kirlokar/Asoke Leylend/Cummins) of 0.8 P.F three Phase 415V/420volts,50C/S 1500 RPM CPCB Approved capacity compressing of Developing 156 BHP Water cooled clock wise rotating with 80 KW / 100 KVA operating capacity Brush Less Alternator close coupled underneath fuel tank ,standard safeties, LLOP With stop solenoid ,battery with lead ,Electric start and Anti Vibration mountings and accessories and AMF control panel as detailed below including transporting and Unloading charges (A) ENGINE :
Water cooled diesel engine suitable for Generator application with a shaft output of 156 BHP 1500 RPM under NTP condition . The Engine Shall Comprise the following standard fitting flexible coupling, fly wheel,air cleaner, fan blower radiator, water pump, fuel filter and lubricatingoil filter etc (B) 12/24 Volt Electronic Starting Equipment Complete with Starter motor dynamo standard batteries with cable flexible exhaust piping of 50cms Length (C) Engine Instrument Panel / Mounted Starting push button /starting key lubricating oil temperature gauge lubricating oil pressure gauge water temperature gauge safety control for low lubricating oil pressure , safety control for high water temperature safety control for over speed ,Hour meter(mechanical)and RPM indicator battery charging ammeter. The engine should be cabable of providing 10% over load for one hour for every 11hours continous run at full load D.ALTERNATOR:
100 KVA /80 KW Capacity Brushless Alternator AC 3phase 50c/s 415/420V 0.8PF 1500 RPM under NTP conditions conforming to IS 13364 (part - II) 1992 to be means of coupling
E. AMF CONTROL PANEL
The AMF control panel cubical should be fabricated with vermin proof and duct proof best quality sheet steel and floor mounted with removable rear panels and hinged front door with enamel paint and incorporating the following suitable provisions for connecting incoming and out going leads having been made on the control panel 1) AC Ammeter and selector switch, 2) Voltmeter and selector switch, 3) 3 Nos current Transformer with suistable ratio,4) Frequency meter, 5) KWH meter, 6)1 No. Power factor meter,
7) Battery charging set comprising of the following for charging the battery from mains. a) Transformer/Rectifier, b) DC Ammeter, c) DC Volt meter, d) ON/OFF switch, e) Charging rate selector switch, f) push botton start, g) push botton stop,h) push botton reset, 8) 1 set Air-break contactor with auxilary neutral contactor for main supply, 9) 1 set low voltage HRC fuse for short circuit protection of the main supply, 10) 1 set Air break contactor with auxiliary neutral contactor for Alternator Supply, 11) 1 set three pole bimetal release for over load protection of alternator, | 1 | Number | 15,82,000 ₹15.8 L | 16,10,000 ₹16.1 L |
| 1.1012) 1 set low voltage HRC fuse for the short circuit protection of the alternator, 13) 1 set DC control relay incorporating engine start/stop and failure to start/lock out, 14).1 set selector switch auto/manual, 15) 1 NO. push botton start, 16) 1 NO. push botton stop, 17) 1 NO. push botton reset, 18) 1 No. signal lamp for indicating load ON main, 19) 1 No. signal lamp for indicating load ON set, 20) 1 No. signal lamp for indicating fails to starts.,21) 1 No. signal lamp for indicating set running, 22) 1 No. signal lamp for indicating bettery charger, 23) 1 set pilot lamp of 3 Nos, 24) MCCB of 250 capacity with magnetic over load release, instant short circuit, 25) Rectangular copper bus bars (1 No. for each phase neutral and earthing terminal) of adequate capacity duly colour coded with heat shrinkable PVC sleaves., 26) 1 No. mains voltage monitor, 27) Hooter/Audio alarm for indication set fails to startand for DG O/L, 28) 1 set timer, 29) Audio visual indicator arrangements for a) low lubricating oil pressure, b) High water temparature, c) Over speed, 30) 1 No. earth fault relay, 31) Isolator to isolate the neutral. Note: 1. The Control panel should be complete with necessary fuses , cables , lables, other accessorries with neutral isolation arrangements. 2. The engine should trip for the following Conditions a) Low lubricant pressure, b) High water temparature. c) Over speed (F) Fuel tank : Fuel tank of 250 litrs a Capacity and with Inlet and Outlet connections level indicator with scale etc .., | |||||
| 2.00 | ERECTION OF GENSET : Providing suitable concrete foundation with cement concrete 1:2:4 with sand cushion all around the foundation erection of 100 KVA Generator set over the existing foundation and erection of generator set with proper alignment over the existing foundation to suit 100 KVA Genset foundation size L3800 mm x w 1700 mm x H 450 mm | 2 | Job | 50,000 ₹1 L | 50,030 ₹1.0 L |
| 3.00 | Supply and installation of Exhaust piping of sufficient length with suitable M.S pipe so as to extend outside the generator with necessary thermal insulation | 10 | Metre | 2,500 ₹25,000 | 2,000 ₹20,000 |
| 4.00 | Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry (SD-221) | 8 | Number | 3,300 ₹26,400 | 3,140 ₹25,120 |
| 5.00 | Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection (SD-76) | 82 | Metre | 550 ₹45,100 | 490 ₹40,180 |
| 6.00 | Supply of tools sucjh as1 no 15" cutting piler , 1no 6" screws driver , 2 nos 9" screw driver , 1 set 6 nos double ended spanner ,1No 1/2 ip hammer , 1No panner for removing engine oil p[lug 1no line tester required for the mainttenence and operation of generator set -1 set | 1 | Set | 2,650 ₹2,650 | 2,510 ₹2,510 |
| 7.00 | Supply and demonstration of the following safety accessories’ a) 1 meter x 1 meter x1/2 inch 11kv rubber mat - 2 nos. b) one set of 4 nos. 9 liters fire buckets with metal stand frame - 1set c) first aid box with medicine - 1no d) 11 kV rubber hand gloves - 2 nos e) 2 Kg capacity dry powder type fire extinguishers - 2 nos f) Hand operated pump to transfer fuel from standard barrel to fuel tank - 1 no g) First aid chat in Tamil and English - 1no. h) Battery water acidity tester - 1 no. | 1 | Number | 20,050 ₹20,050 | 20,010 ₹20,010 |
| 8.00 | Preparation of site plan, physical layout, electrical line schematic diagram in 10 sets. Getting drawing approval from CEIG, preparation of completion report, rectification report and arranging CEIG’s inspection and obtaining safety certificate. Preparation of one set of approved drawing and a copy of safety certificate in a neat frame work to be fixed in the generator room – 1set. | 1 | Job | 1,85,000 ₹1.9 L | 1,00,050 ₹1.0 L |
| 9.00 | Supply and laying of 3 1/2 x 120 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (SD-187) | 65 | Metre | 1,100 ₹71,500 | 1,020 ₹66,300 |
Tender Value
₹24.7 L
EMD Value
₹23,000
Closing Date
13 Feb 2026, 5:00 pmClosed
Superintending Engineer, WRD.,
O/o of the Superintending Engineer, WRD., Upper Palar Basin Circle, Vellore-6
Provision of 100 KVA Diesel Generator Sets with AMF Panel arrangements to the Mordhana Dam in Vellore District.
2026_WRD_653048_1
e Tender Short Term Tender Notice No 06 UPBC Vellore F-Tender 2025-2026 Dated 05 02 2026
Open Tender
Electrical Works
90 days
Gudiyatham
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹23,000
22 May 2026
9 Feb 2026
13 Feb 2026
9 Feb 2026
13 Feb 2026
9 Feb 2026
ERECTION OF GENSET : Providing suitable concrete foundation with cement concrete 1:2:4 with sand cushion all around the foundation erection of 100 KVA Generator set over the existing foundation and erection of generator set with proper alignment over the existing foundation to suit 100 KVA Genset foundation size L3800 mm x w 1700 mm x H 450 mm
Supply and installation of Exhaust piping of sufficient length with suitable M.S pipe so as to extend outside the generator with necessary thermal insulation
Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry (SD-221)
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection (SD-76)
Supply of tools sucjh as1 no 15" cutting piler , 1no 6" screws driver , 2 nos 9" screw driver , 1 set 6 nos double ended spanner ,1No 1/2 ip hammer , 1No panner for removing engine oil p[lug 1no line tester required for the mainttenence and operation of generator set -1 set
Supply and demonstration of the following safety accessories’ a) 1 meter x 1 meter x1/2 inch 11kv rubber mat - 2 nos. b) one set of 4 nos. 9 liters fire buckets with metal stand frame - 1set c) first aid box with medicine - 1no d) 11 kV rubber hand gloves - 2 nos e) 2 Kg capacity dry powder type fire extinguishers - 2 nos f) Hand operated pump to transfer fuel from standard barrel to fuel tank - 1 no g) First aid chat in Tamil and English - 1no. h) Battery water acidity tester - 1 no.
Preparation of site plan, physical layout, electrical line schematic diagram in 10 sets. Getting drawing approval from CEIG, preparation of completion report, rectification report and arranging CEIG’s inspection and obtaining safety certificate. Preparation of one set of approved drawing and a copy of safety certificate in a neat frame work to be fixed in the generator room – 1set.
Supply and laying of 3 1/2 x 120 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (SD-187)
Supply and clarnping of 3 1/2 x 120 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.(SD-210)
Supply and providing cable end termination of 3 1/2 x 120 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete (SD-228)
Supply and fixing of brass cable gland for 3 1/2x 120 sq.mm PVC armoured LTUG Cable with earth connection (SD-169)
Supply and laying of 12 core x 2.5 sq.mm PVC copper cable in a trench to be excavated at a depth of 0.75 metre covering the cable completely through suitable G.I. pipe and refilling the earth to make good (DATA - A)
Supply and clamping of 12 core x 2.5 sq.mm PVC copper cable on post or on wall through suitable G.I. pipe with M.S. clamps (DATA-B)
Supply and fixing of 200A changeover Switches with angle iron frame work with MS cable entry boxes with earth Connection.(SD 659)
Providing fuel to run the DG set for 8 hours full load testing and Commissioning.
GST 18 % in Figures
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_783068.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
TenderDocuments.pdf
Tender Documents • 1.22 MB
BOQ_783068.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid