| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC BHAGIRATHIPUR DOMKAL MSD | DOMKAL | MURSHIDABAD | WEST BENGAL | 742101 | ₹1.4 Cr | L1 | Accepted-AOC LOWEST RATE QUOTED |
| 2 | L2₹1.4 Cr+₹46,980 (0.34%)Rejected-Finance ALAMPUR NODAKHALI | ₹1.4 Cr+₹46,980 (0.34%) | L2 | Rejected-Finance HIGHER THAN L1 |
| 3 | L3₹1.4 Cr+₹1.1 L (0.81%)Rejected-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 UDYAM WB 13 0098535 | MURSHIDABAD | WEST BENGAL | 742237 | ₹1.4 Cr+₹1.1 L (0.81%) | L3 | Rejected-Finance HIGHER THAN L1 |
| Sl No | Description | Qty | Unit | DAS ENTERPRISE L3 | S. P. CONSTRUCTION L2 | M/S.S.S.ENTERPRISE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Overhauling the defective 800 KW, 6.6 KV Motor for Clear Water Pump House
Cost for transportation of the defective 800 KW, 6.6 KV motor from site to workshop at Kolkata by hired vehicle including loading at site with the aid of adequate man power and departmental hoisting arrangement. | 1 | Item | 23,900 ₹23,900 | 23,890 ₹23,890 | 23,836 ₹23,836 Lowest |
| 2.00Unloading the job (Motor Rating - 800 KW, Operating Voltage - 6.6 KV, Rotational Speed - 1490 RPM, Frame - NG450, Sl. No. 2181457/01, Make - CG) at the workshop and carrying out the following tasks by engaging personnel having sufficient knowledge pertaining to the work : | ||||||
| 2.01 | Physical inspection of the motor
Testing of IR and Pl
Measurement of stator winding resistance and inductance
Measurement of BTD RTD resistance
No Load run of the motor with LT supply if motor permits
Measurement of Vibration Temperature
Dismantling of motor
Separation & cleaning of component
Measurement of bearing housing
Condition checking of Bearings, DTT, TB etc.
Checking of Rotor | 1 | Item | 92,100 ₹92,100 | 92,099 ₹92,099 | 92,096.35 ₹92,096.35 Lowest |
| 3.00Supply and delivery of the following materials as per sample for the above-mentioned HT motor : | ||||||
| 3.01 | Dial-type Bearing Temperature Detector (BTD) for non-drive end bearing. | 1 | No | 15,200 ₹15,200 | 15,195 ₹15,195 | 15,141.82 ₹15,141.82 Lowest |
| 3.02 | Bearing 6324/C3 for drive end. | 1 | No | 97,399 ₹97,399 | 97,344 ₹97,344 | 97,321.2 ₹97,321.2 Lowest |
| 3.03 | Bearing 6322/C3 for non-drive end. | 1 | No | 61,999 ₹61,999 | 61,820 ₹61,820 | 61,806.75 ₹61,806.75 Lowest |
| 4.00carrying out the following tasks by engaging personnel, having sufficient knowledge pertaining to the work as mentioned below : | ||||||
| 4.01 | Cutting and disconnecting the both side end-rings (short circuit ring), removing all cracked bars from rotor-slots, manufacturing new set of rotor-bars from aluminium, making short circuit rings of rotor winding, fitting new bars into the rotor slots by push fit, jointing of bars and rings complete followed by machining the rotor. | 1 | Item | 7,86,500 ₹7,86,500 | 7,86,100 ₹7,86,100 | 7,85,998.06 ₹7,85,998.06 Lowest |
| 4.02 | Dynamic balancing of the rotor with cooling fan. | 1 | Item | 52,900 ₹52,900 | 52,600 ₹52,600 | 52,439.2 ₹52,439.2 Lowest |
Tender Value
Refer Docs
EMD Value
₹2.8 L
Closing Date
21 Jul 2025, 2:00 pmClosed
SUPERINTENDING ENGINEER
81/2/7, PHEARS LANE, COMMERCIAL COMPLEX, 3RD FLOOR, KOLKATA-700012.
Miscellaneous electro-mechanical repairing works at Surface Water Based Water Supply Scheme for Arsenic Affected Areas of South 24 Parganas District (34 MGD) under South 24 Parganas Mechanical Division, PHE Dte.
2025_PHED_862839_1
01/SE/MC-I/WBPHED/2025-2026
Open Tender
Electrical Work/ Equipment
Item Rate
SOUTH 24PGS.
Please refer Tender documents.
5 documents required · 5 mandatory
₹2.8 L
11 Sept 2025
24 Jun 2025
23 Jul 2025
25 Jun 2025
21 Jul 2025
25 Jun 2025
Amount
Overhauling the defective 800 KW, 6.6 KV Motor for Clear Water Pump House Cost for transportation of the defective 800 KW, 6.6 KV motor from site to workshop at Kolkata by hired vehicle including loading at site with the aid of adequate man power and departmental hoisting arrangement.
Unloading the job (Motor Rating - 800 KW, Operating Voltage - 6.6 KV, Rotational Speed - 1490 RPM, Frame - NG450, Sl. No. 2181457/01, Make - CG) at the workshop and carrying out the following tasks by engaging personnel having sufficient knowledge pertaining to the work :
Physical inspection of the motor Testing of IR and Pl Measurement of stator winding resistance and inductance Measurement of BTD RTD resistance No Load run of the motor with LT supply if motor permits Measurement of Vibration Temperature Dismantling of motor Separation & cleaning of component Measurement of bearing housing Condition checking of Bearings, DTT, TB etc. Checking of Rotor
Supply and delivery of the following materials as per sample for the above-mentioned HT motor :
Dial-type Bearing Temperature Detector (BTD) for non-drive end bearing.
Bearing 6324/C3 for drive end.
Bearing 6322/C3 for non-drive end.
carrying out the following tasks by engaging personnel, having sufficient knowledge pertaining to the work as mentioned below :
Cutting and disconnecting the both side end-rings (short circuit ring), removing all cracked bars from rotor-slots, manufacturing new set of rotor-bars from aluminium, making short circuit rings of rotor winding, fitting new bars into the rotor slots by push fit, jointing of bars and rings complete followed by machining the rotor.
Dynamic balancing of the rotor with cooling fan.
Thorough cleaning of stator winding, repairing of stator-slots and wedges, and heat varnishing of the stator winding. This includes the cost for dismantling the motor part by part, complete overhauling, reassembling the same by using all newly supplied materials as mentioned above, metalizing and machining of dive-end bearing housing, succeeded by testing and painting the job complete.
Cost for transportation of the repaired 800 KW, 6.6 KV motor from workshop at Kolkata to site by hired vehicle including loading at site with the aid of adequate man power and proper hoisting arrangement.
Improvement of Ventilation Arrangement at Clear Water Pump House Dismantling and taking out the defective/inoperative materials in connection with the existing ventilation system such as fans, air filters, air grilles & louvers, broken segment of outside platform etc. along with its allied accessories by engaging competent manpower and applying proper tools & plants as per direction of EIC.
Supply and delivery of the following materials at site :
Axial Flow Fan (Sweep-610 mm, Capacity-8500 CMH, Static Pressure-30 mm WG, Speed-1440 RPM, Motor Rating-1.5 kW/4 Pole)
Air Filter with filter housing and inlet inlet louvers (Type-3 Ply HDPE Panel Filter, Size-610 mm x 610 mm x 50 mm) (4 nos. in a set)
Chequered Plate for outside platform (2030 mm x 1340 mm x 6 mm thick)
Air Grilles (1500 mm x 325 mm)
Installation of the above supplied materials (Item No. 7.01-7.04) in their respective positions by supplying all the necessary jointing materials etc. by engaging competent manpower and applying proper tools & plants complete followed by testing the entire installation up to entire satisfaction of EIC. This also includes the cost pertaining to the necessary repairs of the structural segment, outside the pumping station and painting with two coats of synthetic enamel paint after preparing the surfaces properly and subsequent priming work.
Replacement of the HT & LT Power Cable System Supply & delivery of the following materials at site :
6.6 kV Grade (UE), 185 sq.mm, 3 Core, Aluminium Conductor, XLPE Insulated, Galvanised Steel Flat Strip Armoured Cable conforming to IS 7098 (Part-2) 2011, with up to date amendments (From RWPS Feeder No.-2 at 33/6.6 kV Sub-Station to Incomer-2 at RWPS).
1.1 kV Grade, 185 sq.mm, 3.5 Core, Aluminium Conductor, XLPE Insulated, Aluminium Armoured Cable conforming to IS 7098 (Part-1) 1988, with up to date amendments (From WTP Feeder No.-1/2 at 33/6.6 kV Sub-Station to Incomer-1/2 at Filter House).
Indoor Termination Kit for the above supplied cable (Item No. 9.01)
Indoor Termination Kit for the above supplied cable (Item No. 9.02)
Heat Shrinkable Straight Through Joint Kit, suitable for the above supplied cable (Item No. 9.01)
150 mm diameter, medium gauge G.I. pipe with necessary fittings and jointing materials for protection of cable while crossing the road.
Laying of one no. cable above 35 sq.mm and upto 185 sq.mm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) nos. bricks per metre including filling the space between the bricks and cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying only cable above 50 sq.mm but not exceeding 400 sq.mm through RCC/ Hume/GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core.
Finishing the end of the XLPE/PVC armoured cables (Item No. 9.01-9.02) by crimping method incl. supplying and fixing solderless socket, tapes, anticorrosive paste & jointing materials.
S. P. CONSTRUCTION (BID ID -6742928)
DAS ENTERPRISE (BID ID -6742109)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .