Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹17.2 L+₹4.6 L (36.3%)Rejected-Finance | L2 | Rejected-Finance NOT A LOWEST BID | |
| 3 | L3₹18.4 L+₹5.8 L (46.1%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance NOT A LOWEST BID | |
| 4 | L4₹19.9 L+₹7.3 L (57.9%)Rejected-Finance | L4 | Rejected-Finance NOT A LOWEST BID |
Tender Value
₹20.2 L
EMD Value
₹40,340
Closing Date
21 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MH AND RH KIRKEE
GE MH RH KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIR REPLACEMENT OF LT DISTRIBUTION SYSTEM BY REPLACEMENT OF US LT CABLES AND SWITCH GEARS AT MH KIRKEE UNDER GE MH AND RH KIRKEE
2021_MES_462580_1
8216/E8
Open Tender
Civil Works
Item Rate
180 days
KIRKEE AND AUNDH
AS PER TENDER DOCUMENTS AND NIT
6 documents required · 6 mandatory
₹500
Yes
GE MH AND RH KIRKEE
₹40,340
Yes
10 Sept 2021
24 Jul 2021
23 Aug 2021
24 Jul 2021
21 Aug 2021
7 Aug 2021
24 Jul 2021 - 31 Jul 2021
60 days
Amount
Disconnecting incoming and outgoing cable/busbar connections, taking out from the cradle and overhauling of manually/electrically operated, draw out type air circuit breaker of any make, 03 or 04 pole, 415 volts, AC, current rating 800 A Make C &S all as specified under - (a) Cleaning of dust, spider web, foreign particles etc. (b) Removal of old grease from various parts. (c) Cleaning of various parts with CRC-2-26. (d) Check the tightness of all hardware. (e) Replacement of damaged parts. (f) Re-greasing and lubricating of all rotating, moving parts. (g) Checking, setting and fault attending of spring charging mechanism operation. (h) Checking, setting and fault attending of closing and tripping mechanism operation. (j) Checking, setting and fault attending of breaker auxiliary switch contact healthiness. (k) Checking of breaker operation in isolating / test and service position. (l) Confirming of Insulation resistance value of each live part w.r.t earth.
Disconnecting incoming and outgoing cable/busbar connections, taking out from the cradle and overhauling of manually/electrically operated, draw out type air circuit breaker of 800A S1 EDO 3P SR18G, 03 or 04 pole, 415 volts, AC, Make : L & T all as specified under - (a) Cleaning of dust, spider web, foreign particles etc. (b) Removal of old grease from various parts. (c) Cleaning of various parts with CRC-2-26. (d) Check the tightness of all hardware. (e) Replacement of damaged parts. (f) Re-greasing and lubricating of all rotating, moving parts. (g) Checking, setting and fault attending of spring charging mechanism operation. (h) Checking, setting and fault attending of closing and tripping mechanism operation. (j) Checking, setting and fault attending of breaker auxiliary switch contact healthiness. (k) Checking of breaker operation in isolating / test and service position. (l) Confirming of Insulation resistance value of each live part w.r.t earth.
All as per item No 2 above but 1600A S1 MDO 3P SR18
All as per item No 2 above but 1600A S1 EDO 3P SR18G
All as per item No 2 above but 1600A S1 EDO 4P SR18G
All as per item No 2 above but 2000A S1 EDO 4P SR18G
All as per item No 2 above but 2500A S1 EDO 3P SR18G
NOTE for item No. 2 to 7:- 1. The contractor has to submit detail service report for each breaker over-hauled. 2. All the necessary tools and tackles shall be arranged by contractor for the subject work. 3. The contractor has to replace minor spares like spring washers, washers locking pin, circlip, spring, small nut-bolts etc. free of cost. 4. Contractor has to arrange for necessary cleaning agent (petrol, diesel, CRC 2-26 etc.) and lubricating material like grease, oil and lubricating sprays if any, as required for subject work. 5. The servicing / overhauling of breaker is to be carried out at site. However, if any breaker requires to be taken to contractor’s work-shop, then contractor has to arrange transportation of such breakers from site to Work-shop and back to site without extra cost. 6. Major spares required to be replace during servicing will be measured and paid under relevant item as specified in the schedule hereforth. 7. Load break test should done in front of Engineer-in-Charge. 8. All required load bank should be carried by Contactor without extra cost. 9. Servicing work done with prior permission of Engineer-in-Charge as breaker installed inside the hospital. 10. All working executive must performed technical qualification and necessary exprience of work.
Supply & fix in repair / replacement the following spares of ACB of make L& T:-
Supply & fix in repair / replacement of Pole Assy. 400-1250 S1 D/O
Supply & fix in repair / replacement of Pole Assy. 1600 S1 D/O
Supply & fix in repair / replacement of Pole Assy. 2000 S1 D/O
Supply & fix in repair / replacement of Pole Assy.2500 S1 D/O
Supply & fix in repair / replacement of CTs for SR18 800S1
Supply & fix in repair / replacement of CTs for SR18 1600S1
Supply & fix in repair / replacement of CTs for SR18 2000S1
Supply & fix in repair / replacement of CTs for SR18 2500S1
Supply & fix in repair / replacement of Jaw contact Assy 400-1250A S1
Supply & fix in repair / replacement of Jaw contact Assy 1600S1Supply in repair / replacement of 2000S1
Supply & fix in repair / replacement of Jaw contact Assy. 2500 S1
Supply & fix in repair / replacement of Vertical Terminal Adapter 400-1250 S1
Supply & fix in repair / replacement of Vertical Terminal Adapter 1600/2000 S1
Supply & fix in repair / replacement of Vertical Terminal Adapter 2000 C
Supply & fix in repair / replacement of Vertical Terminal Adapter 2500 S1
Supply & fix in repair / replacement of Arc Chute 630-1250 S1
Supply & fix in repair / replacement of Arc Chute 1600/2000S1
Supply & fix in repair / replacement of Arc Chute 2500 C/H/S1
Supply & fix in repair / replacement of Fixed Arcing Contact 630-1250 S1
Supply & fix in repair / replacement of Fixed Arcing Contact 1600 S1
Supply & fix in repair / replacement of Fixed Arcing Contact 2000 S1
Supply in repair / replacement of Fixed Arcing Contact 2500S1
Supply & fix in repair / replacement of Moving Arcing Contact 630-1250 S1 2000S1Supply in repair / replacement of 2500
Supply & fix in repair / replacement of Shutter Assy. 400-2000 S1Supply in repair / replacement of
Supply & fix in repair / replacement of Shutter Assy. Supply in repair / replacement of 3200 S1
Supply & fix in repair / replacement of Cradle Terminal Assy. 400-1250 S1
Supply & fix in repair / replacement of Cradle Terminal Assy. 1600/2000 S1
Supply & fix in repair / replacement of Cradle Terminal Assy. 2500 S1
Supply & fix in repair / replacement of Cradle Terminal support 400-1250 S1
Supply & fix in repair / replacement of Cradle Terminal support 1600/2000A S1
Supply & fix in repair / replacement of Cradle Terminal support 2500S1
Supply & fix in repair / replacement of Shunt Release EA 220V DC
Supply & fix in repair / replacement of Under-voltage Release 240V AC
Supply & fix in repair / replacement of Closing Coil 240V AC/ 220V DC
Supply & fix in repair / replacement of FRCD 400-3200S1 (3P & 4P)
Supply & fix in repair / replacement of Left-plate Assy 400-3200 S1
Supply & fix in repair / replacement of Motor 240V AC
Supply & fix in repair / replacement the following spares of ACB of make C & S:-
Supply & fix in repair / replacement of Motor Auxiliary isolating contact assembly CS-AIH-2-116(4P)
Supply & fix in repair / replacement of Motor Compact UVT Coil6D- 16D/06N-2OS, CS-AUH-V-A-NA
Supply & fix in repair / replacement of Motor Shunt Trip 6D-16D/06N-2OS,CS-AVH-S-116-MA
Supply & fix in repair / replacement of Motor Closing Coil 6D-16D/06N-2OS,CS-AVH-S-116-MA
Supply & fix in repair / replacement of Motor Arcing Contact, CS-ARCCONT-O8D
Supply & fix in repair / replacement of Motor Main isolating Contact(Jaw Contacts) CS-MIC-O8D(50k)
Supply & fix in repair / replacement of Motor Cradle terminal for drawout AH ACB
Supply & fix in repair / replacement of Motor Arc Chutes
Supply & fix in repair / replacement of Motor Charging Motors (220 Volts AC / DC)
Supply & fix in repair / replacement of Motor Control relay for charging Motor (220 V AC)
Supply & fix in repair / replacement of Motor Micro switch for motor cut off 6 D
Supply & fix in repair / replacement of Motor Drawout Handle
Supply & fix in repair / replacement of Motor Complete lower mechanism assly of 800 A
Taking down & Supply and fix following type MCCBs in various panels:-
MCCB 400 Amp four pole, Adjustable type 415 volts, 36 kA, suitable for existing of panel and as per sample
MCCB 350 Amp four pole, 415 volts, 36 kA suitable for existing of panel and as per sample
MCCB 250 Amp four pole, 415 volts, 36 kA suitable for existing of panel and as per sample
MCCB 200 Amp four pole, 415 volts, 36 kA suitable for existing of panel and as per sample
MCCB 160 Amp four pole, 415 volts, 36 kA suitable for existing of panel and as per sample
MCCB 125 Amp four pole, 415 volts, 25 kA suitable for existing of panel and as per sample
MCCB 100 Amp four pole, 415 volts, 25 kA suitable for existing of panel and as per sample
MCCB 63 Amp four pole, 415 volts, 25 kA suitable for existing of panel and as per sample
M&L for Repair to APFC panel by replacing old U/S damaged electrical components parts and providing new parts as under:-
25 KVAR capacitor Heavy Duty
20 KVAR capacitor Heavy Duty
12.5 KVAR capacitor Heavy Duty
10 KVAR capacitor Heavy Duty
S & F heavy duty power contactor for capacitor of 50 KVAr
S & F heavy duty power contactor for capacitor of 25 KVAr
S & F heavy duty power contactor for capacitor of 20 KVAr
S & F heavy duty power contactor for capacitor of 12.5 KVAr
S & F heavy duty power contactor for capacitor of 10 KVAr
400A FN Type switch with bollet HTC Fuse. Make L & T
S & F APFC Relay meter for 08 stage suitable for existing panel of 144 x 144 mm size
S & F APFC Relay meter for 12 stage suitable for existing panel of 144 x 144 mm size
125 A control fuse links top and base
80 A control fuse links top and base
63 A control fuse links top and base
40 A control fuse links top and base
32 A control fuse links top and base
Illuminated push buttons red/green
LED type RYB indicating lamps(set of three)
Supply and fix in repair Voltage meter as per site requirement sutiable incoming braker
Supply and fix in repair Amps meter as per site requirement sutiable incoming braker
Supply and fix any size & any shape of CT for Ammeter of capacity upto 800/5
Supply and fix including taking down of burnt aluminum bus bar of any size and capacity and fix with all necessary provision cutting, bending, drilling, fixing with nut bolt washers as directed by Engineer-in-Charge
Servicing of LT indoor/outdoor Panel/feeder pillar box any type by disconnecting and removing all the incoming and outgoing cable connection from MCCBs, cleaning of dust with air blower, replacement of unserviceable MCCBs, burnt busbars, burnt thimbles, unserviceable indicator lamps, unserviceable Ammeter, unserviceable Volt meter, reconnections after proper cleaning of contacts with CRC solution and fixing of hanging front and rear openings with new hinges welding etc. including painting of complete panel included stand (after proper scrubbing) with synthetic enamel paint (ordinary tint) one coat as per specified colour code including writing of panel/feedar panel location using black systhetic paint complete all as specified and directed by Engr -in- charge. Note : (i) Cost of labour, painting of panel, cotton waste insulator and thimbles and T&P required for upkeeping/maint work is inclusive in quoted rate. (ii) MCCBs, Bus bars, indicator lamps, Ammeter, Volt meter, will be measured & paid separately as supply only .
S & F Change over of capacity 100 amps 4 pole including taking down of old change over removing all connected cable and fixing of new change over with all suitable connection as specified and directed by Engineer-in-Charge
All as per item No 20 but 250 Amps
All as per item No 20 but 400 Amps
Taking down unserviceable cable of any size upto 300 sq mm carefully from trenches / poles / ducts / LT ,panel, OH conductors etc at different locations all as specified and directed by Engr-in-Charge
Supply and Fix for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 35 sqmm 3.5 core including aluminium cable gland, nut bolts washers & lugs,all as specified and directed
All as per item No 24 but 50 sqmm 3.5 core
All as per item No 24 but 70 sqmm 3.5 core
All as per item No 24 but 120 sqmm 3.5 core
All as per item No 24 but 185 sqmm 3.5 core
All as per item No 24 but 240 sqmm 3.5 core
Supply & Fix Heat shrink straight through joint LT 1100 volts grade 25-50 sqmm, 4 core, make-Raychem, Cat No-EPKJ0130 or equivelent of M-Seal/MS Seal/3M
Supply only Heat shrink straight through joint LT 1100 volts grade 70-120 sqmm, 4 core, make-Raychem, Cat No-EPKJ0137 or equivelent of M-Seal/MS Seal/3M
Supply only Heat shrink straight through joint LT 1100 volts grade 150-185 sqmm, 4 core, make-Raychem, Cat No-EPKJ0144 or equivelent of M-Seal/MS Seal/3M
Supply only Heat shrink straight through joint LT 1100 volts grade 240-300 sqmm, 4 core, make-Raychem, Cat No-EPKJ0144 or equivelent of M-Seal/MS Seal/3M
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of pipe line in soft / loose soil and getting out in soft / loose soil complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil all as specified & directed
Removing excavated meterial to a distance n.exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified & directed by Engineer-in-Charge
M&L for natural dry river sand cushioning including spreading, levelling and hand punning to underground cable in trench all as specified and directed. Note : Punned thickness shall only be measured and paid.
M&L for brick protection with PCC cable cover class LV, type-I, flat size 250x150x40 mm factory casted ISI marked all as specified and directed.
PURVA ELECTRICALS AND ENGINEERS
M/S. Niksun Electro-Infra Private Limited
SHREE VAIBHAV ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .