Loading…
Loading…
Tender ID
Tender Value
₹31.9 L
EMD Value
₹95,845
Closing Date
10 Apr 2026, 6:00 pmClosed
SM(E-E), AAI, Agatti Airport
SM(E-E), AAI, Agatti Airport-682553
SITC of additional Air conditioners and replacement of outlived old Air Conditioners at various location of Agatti Airport
2026_AAI_272128_1
AAI/AGT/ENGG (E)/AC/2025-26/NIT-03
Open Tender
Electrical Works
Works
SM(E-E), AAI, Agatti Airport
Please refer Tender documents.
20 documents required · 20 mandatory
₹1,180
₹95,845
23 Mar 2026
21 Mar 2026
13 Apr 2026
21 Mar 2026
10 Apr 2026
21 Mar 2026
21 Mar 2026 - 3 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, testing, and commissioning of air cooled factory assembled 5-star rated minimum 1.0 TR Split type Inverter AC having remote operation, minimum 5.00 ISEER rated, eco friendly refrigerant, copper condensor coil, Inverter Rotary compressor i/c drilling necessary hole on the wall(if required) and making good the damages(if any) along with the supply and installation of manufacturer standard length of copper refregerant liquid, suction pipe and Copper conductor multi core cable etc. with all necessary standard protections, features as per OEM suitable for operation on 230V, 50 Hz, 1-Phase AC Supply etc. complete as required. | 3 | Nos | - | - |
| 2 | Supply, Installation, testing, and commissioning of air cooled factory assembled 5-star rated minimum 1.5 TR Split type Inverter AC having remote operation, minimum 5.00 ISEER rated, eco friendly refrigerant, copper condensor coil, Inverter Rotary compressor i/c drilling necessary hole on the wall(if required) and making good the damages(if any) along with the supply and installation of manufacturer standard length of copper refregerant liquid, suction pipe and Copper conductor multi core cable etc. with all necessary standard protections, features as per OEM suitable for operation on 230V, 50 Hz, 1-Phase AC Supply etc. complete as required. | 4 | Nos | - | - |
| 3 | Supply, Installation, testing, and commissioning of air cooled factory assembled 5-star rated minimum 2.0 TR Split type Inverter AC having remote operation, minimum 5.00 ISEER rated, eco friendly refrigerant, copper condensor coil, Inverter Rotary compressor i/c drilling necessary hole on the wall(if required) and making good the damages(if any) along with the supply and installation of manufacturer standard length of copper refregerant liquid, suction pipe and Copper conductor multi core cable etc. with all necessary standard protections, features as per OEM suitable for operation on 230V, 50 Hz, 1-Phase AC Supply etc. complete as required. | 4 | Nos | - | - |
| 4 | Supply, Installation, testing, and commissioning of air cooled factory assembled 3-star rated minimum 3.0 TR Split type Inverter AC having remote operation, eco friendly refrigerant, copper condensor coil, Inverter Rotary compressor i/c drilling necessary hole on the wall(if required) and making good the damages(if any) along with the supply and installation of manufacturer standard length of copper refregerant liquid, suction pipe and Copper conductor multi core cable etc. with all necessary standard protections, features as per OEM suitable for operation on 415 V, 50 Hz, 3-Phase AC Supply etc. complete as required. | 5 | Nos | - | - |
| 5 | Supplying, Installation, Testing and Commissioning of minimum 4 TR Floor mounted tower AC system having remote Operation and Rotary/scroll compressor suitable for operation on 415 V, 50Hz, 3-Ph A.C supply including iron stand for IDU along with the supply and laying of standard length of copper refregerant liquid and suction pipe and Cu conductor multi core cable as per OEM recommendation by drilling necessary hole on the concrete wall and making good the damages(if any) etc. with all necessary protections and features as per OEM etc. complete as required. | 8 | Nos | - | - |
| 6 | Supplying, Installation, Testing and Commissioning of minimum 2 TR Ductable split AC system having remote Operation and Rotary/scroll compressor suitable for operation on 230 V, 50Hz,Single phase A.C supply including supply and laying of standard length of copper refregerant liquid and suction pipe and Cu conductor multi core cable as per OEM recommendation by drilling necessary holes and making good the damages(if any) etc. with all necessary protections and features as per OEM etc. complete as required. | 2 | Nos | - | - |
| 7 | Supply, installation, testing, and commissioning of floor-standing cold & normal water cooler with stainless steel body, 40 LPH cooling capacity, 80 Ltr storage, eco-friendly refrigerant, push-type taps, and drain arrangement etc. complete as required. | 2 | Nos | - | - |
| 8Supply and laying of OEM recommended refrigerant copper piping with Nitrile rubber insulation of suitable size for following capacity split air conditioners i/c jointing/bracing with the existing copper piping (wherever applicable) etc. complete as required. | |||||
| 8.1 | 1TR Split AC | 6 | Meters | - | - |
| 8.2 | 1.5TR Split AC | 16 | Meters | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.40 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.94 MB
te.pdf
Tender Documents • 17.64 MB
BOQ_317806.xls
BOQ • 11.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .