Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹23.8 L+₹5.9 L (32.9%)Rejected-Finance NOT FOUND | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹24.0 L+₹6.1 L (33.9%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹27.5 L+₹9.6 L (53.6%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹33.5 L+₹15.6 L (86.9%)Rejected-Finance NAGAR PANCHAYAT PATHARDEVA DEORIA | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | shiv shanker enterprises L2 | YOGINDER KUMAR GUPTA AND COMPANY L1 | AMBIKA ENTERPRISES L4 | M/s Shree Bala Ji Construction Company L5 | BHATIA ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of existing unserviceable LT Panel of any type, size and capacity, after carefully disconnecting all incoming and outgoing electrical connections, control wiring, earthing connections and accessories, including dismantling from foundation/supports, breaking PCC foundation (if any), and removal from site, complete all as specified and as directed. | 3 | EACH | 500 ₹1,500 | 500 ₹1,500 | 1,000 ₹3,000 | 1,000 ₹3,000 | 400 ₹1,200 Lowest |
| 2.00 | Supply, installation, testing and commissioning of capacitor duty contactor-controlled Automatic Power Factor Correction (APFC) Panel, indoor type, manufactured and assembled in a CPRI-approved panel manufacturing facility, suitable for linear and non-linear loads, complete with self-healing MPP capacitors of 480 V rating having minimum design life of 150,000 operating hours, capable of automatic switching in different steps through a site-programmable APFC relay, suitable for 3-phase, 440 V, 50 Hz system, of capacity 150 kVAR (in steps of 4 × 25 kVAR, 2 × 15 kVAR and 2 × 10 kVAR), complete with incoming MCCB having adjustable overload and short-circuit protection of suitable rating and rupturing capacity, outgoing MCBs/MCCBs of suitable ratings and rupturing capacities, 7% detuned aluminium wound reactors suitable for operation at 440 V, auto/manual operating mode selector, capacitor ON/OFF indication lamps, digital multifunction meter for monitoring electrical parameters, including all internal wiring, bus bars, control wiring, control components and accessories necessary for satisfactory operation, complete all as specified and as directed.
NOTE: Cost of cable glands, cable lugs, internal wiring, earthing terminals, PCC foundation (if required) and all other accessories/components necessary for satisfactory functioning of the APFC panel shall be deemed to be included in the quoted rate. Detailed GA drawing, schematic diagram and component schedule of the APFC panel shall be got approved from the Accepting Officer before procurement/manufacture. The quoted rate shall also be deemed to include all accessories/components of suitable capacity required for satisfactory operation of the system, even though not specifically mentioned in the BOQ, and no extra claim whatsoever shall be admissible on this account during the currency of the contract. | 1 | EACH | 2,45,786 ₹2,45,786 | 1,75,461 ₹1,75,461 Lowest | 2,95,000 ₹2,95,000 | 6,00,000 ₹6,00,000 | 3,05,000 ₹3,05,000 |
| 3.00 | All as per Item No 02 above, but for APFC Panel of capacity 120 kVAR capacity with automatic switching in steps of 4 × 20 kVAR, 2 × 15 kVAR and 1 × 10 kVAR, complete all as specified and as directed. | 1 | EACH | 1,95,786 ₹1,95,786 | 1,48,846 ₹1,48,846 Lowest | 2,70,000 ₹2,70,000 | 5,00,000 ₹5,00,000 | 2,05,000 ₹2,05,000 |
| 4.00 | Repair/servicing of Automatic Power Factor Correction (APFC) Panel of capacity 25 kVAR to 80 kVAR by disconnecting and reconnecting LT cable connections, opening the panel, carrying out thorough inspection, cleaning, fault finding and checking of all components, including replacement of unserviceable capacitors, capacitor-duty contactors, APFC relays, indication lamps, selector switches, push buttons, NO/NC contacts and other similar minor control components as required, including replacement of defective internal wiring with copper conductor cable complete with PVC beading, ferrules, glands, lugs and termination accessories, reassembly of the panel, testing, calibration and commissioning for satisfactory operation, complete all as specified and as directed.
NOTES:-
(1) Rate quoted shall be deemed to include all labour, T&P, consumables, minor sundry items required for completion of the work. Major components such as capacitors, contactors and APFC relays shall be measured and paid for separately under relevant items, wherever provided in the Schedule.
(2) Repair/servicing shall be carried out in accordance with the "Notes for Item Nos. 03 & 04 (Repairs to APFC Panels)" appended at the end of the BOQ. The quoted rate shall be deemed to include compliance with all provisions contained therein. | 5 | EACH JOB | 1,500 ₹7,500 | 1,500 ₹7,500 | 10,000 ₹50,000 | 5,000 ₹25,000 | 700 ₹3,500 Lowest |
| 5.00 | -ditto- as per Item No. 04 here-in-before but for APFC panel of capacity 100 to 200 KVAR | 1 | EACH | 2,000 ₹2,000 | 1,500 ₹1,500 | 15,000 ₹15,000 | 5,000 ₹5,000 | 800 ₹800 Lowest |
| 6.00 | S&F Automatic Power Factor Controller Relay type 3 Phase/ 3 CTs, with inbuilt solid state automatic power factor correction arrangement, having microprocessor (intelligent) based control circuit & capacitor duty contactor power switching 8 Stage, having required capacity as per site requirement, connecting Single Phase and Three Phase Capacitors, compensation of each Phase, Measures A Power Factor, relay, microprocessor based to replace defective APFC relay with digital display of power factor and other parameters to sense power factor through control CT and give phased impulses to contactor coils for switching ON-OFF required number of capacitors as per requirement to achieve required power factor complete all as specified and directed. | 1 | EACH | 7,500 ₹7,500 | 7,200 ₹7,200 | 45,000 ₹45,000 | 20,000 ₹20,000 | 6,000 ₹6,000 Lowest |
| 7.00S&F Self-healing Capacitor heavy duty Can (Cylindrical) type, 3 Phase 440 Volt, 50 Hz, complete all as specified and as directed for the following capacities :- | ||||||||
| 7.01 | 5 KVAR | 2 | EACH | 900 ₹1,800 | 1,100 ₹2,200 | 1,050 ₹2,100 | 800 ₹1,600 Lowest | 1,800 ₹3,600 |
| 7.02 | 10 KVAR | 4 | EACH | 1,700 ₹6,800 | 2,000 ₹8,000 | 2,050 ₹8,200 | 1,000 ₹4,000 Lowest | 2,100 ₹8,400 |
| 7.03 | 15 KVAR | 4 | EACH | 2,200 ₹8,800 | 2,500 ₹10,000 | 2,550 ₹10,200 | 1,200 ₹4,800 Lowest | 2,300 ₹9,200 |
Tender Value
₹30.0 L
EMD Value
₹59,920
Closing Date
30 Jun 2026, 6:00 pmClosed
GE (AF) SIRSA
OFFICE OF GARRISON ENGINEER AIR FORCE STATION SIRSA HARYANA-125055
REPAIR MAINT IMPROVEMENT OF APFC VOLTAGE STABILIZER ALONGWITH ALLIED WORKS AT AF STN SIRSA
2026_MES_772614_1
GE/SRA/T-14/2026-27
Open Tender
Miscellaneous Works
Item Rate
240 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) SIRSA
₹59,920
Yes
24 Jul 2026
16 Jun 2026
1 Jul 2026
16 Jun 2026
30 Jun 2026
25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of existing unserviceable LT Panel of any type, size and capacity, after carefully disconnecting all incoming and outgoing electrical connections, control wiring, earthing connections and accessories, including dismantling from foundation/supports, breaking PCC foundation (if any), and removal from site, complete all as specified and as directed. | 3 | EACH | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.69 MB
Tender.pdf
Tender Documents • 1.74 MB
CREDIT.pdf
Additional Documents • 0.07 MB
BOQ_865143.xls
BOQ • 0.45 MB
GENINSTRCTIONT.pdf
Tender Documents • 1.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .