| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAdmitted-Finance | ₹23.2 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | Rejected-Technical Documents are not found in order as per NIT. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Documents are not found in order as per NIT. |
| Sl No | Description | Qty | Unit | M/S LAB GUARD INDIA L1 |
|---|---|---|---|---|
| 1.01 | Repair/Replacement of pulley & wire and servicing of fume hood lifting shutter complete in all respects. | 10 | Each | 8,228 ₹82,280 Lowest |
| 1.02 | Replacement of Impeller with casing,Main Body PP Material Thickness 10 mm, FRP thickness 03 mm, Dimension of main body. Dia 18”x Breadth 6” Suction Point Dia 10”. Exhaust Point 10 ”Motor Stand MS Stand Dimension 10”x10”x10” with angle Support Three Side .size-N-20. | 5 | Each | 69,600 ₹3,48,000 Lowest |
| 1.03 | Replacement of Impeller with cashing, Main Body PP Material Thickness 10 mm, FRP thickness 03 mm, Dimension of main body Dia. 22”x Breadth 8” Suction Point Dia. 10”.Exhaust Point 10 ”Motor Stand MS Stand Dimension 10”x10”x10” with angle Support Three Side. Size- N-25. | 13 | Each | 71,520 ₹9,29,760 Lowest |
| 1.04 | Replacement of Crompton Make, 2 HP motor, 1440 RPM, 3 phase, AMP 05,Volt 440, RPM 1450. | 5 | Each | 18,774 ₹93,870 Lowest |
| 1.05 | Replacement of Crompton Make, 5 HP motor, 1440 RPM, 3 phase, AMP 09, Volt 440, RPM 1450 . | 15 | Each | 27,342 ₹4,10,130 Lowest |
| 1.06 | Modification of electronic control (Air flow monitor) lighting system to manual system as required. | 54 | Each | 3,325 ₹1,79,550 Lowest |
| 1.07 | Modification of electronic control (Air flow monitor) starter system to 5HP manual starter system,make-Havells /Crompton / Anchor with lead 4 core 1.5mm as required. | 11 | Each | 9,922 ₹1,09,142 Lowest |
| 1.08 | Modification of electronic control (Air flow monitor) starter system to 7HP manual starter system, make- Havells / Crompton/Anchor with lead 4 core 2.5mm as required. | 11 | Each | 10,527 ₹1,15,797 Lowest |
| 1.09 | Replacement of main cable of fume hoods, Size-10mm 4 core make-Polycab/Hevells/Anchor. | 30 | Meter | 1,250 ₹37,500 Lowest |
| 1.10 | Replacement of Cable connector 100 Amp. | 5 | Each | 1,980 ₹9,900 Lowest |
Tender Value
₹22.5 L
EMD Value
₹45,043
Closing Date
23 May 2026, 5:00 pmClosed
Sr. S.E (E)
Sector 10, Jankipuram Extn., Sitapur Road, Lucknow
Renovation of chemical Fume-hoods at Jankipuram campus of CDRI, Lucknow.
2026_CSIR_276925_1
2/02/2026-Engg.
Open Tender
Electrical Works
Item Rate
120 days
Sector 10, Jankipuram Extn., Sitapur Road
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹45,043
5 Jun 2026
8 May 2026
25 May 2026
8 May 2026
23 May 2026
8 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Repair/Replacement of pulley & wire and servicing of fume hood lifting shutter complete in all respects. | 10 | Each | 6,800 | ₹68,000 |
| 1.02 | Replacement of Impeller with casing,Main Body PP Material Thickness 10 mm, FRP thickness 03 mm, Dimension of main body. Dia 18”x Breadth 6” Suction Point Dia 10”. Exhaust Point 10 ”Motor Stand MS Stand Dimension 10”x10”x10” with angle Support Three Side .size-N-20. | 5 | Each | 58,000 | ₹2,90,000 |
| 1.03 | Replacement of Impeller with cashing, Main Body PP Material Thickness 10 mm, FRP thickness 03 mm, Dimension of main body Dia. 22”x Breadth 8” Suction Point Dia. 10”.Exhaust Point 10 ”Motor Stand MS Stand Dimension 10”x10”x10” with angle Support Three Side. Size- N-25. | 13 | Each | 59,600 | ₹7,74,800 |
| 1.04 | Replacement of Crompton Make, 2 HP motor, 1440 RPM, 3 phase, AMP 05,Volt 440, RPM 1450. | 5 | Each | 14,900 | ₹74,500 |
| 1.05 | Replacement of Crompton Make, 5 HP motor, 1440 RPM, 3 phase, AMP 09, Volt 440, RPM 1450 . | 15 | Each | 21,700 | ₹3,25,500 |
| 1.06 | Modification of electronic control (Air flow monitor) lighting system to manual system as required. | 54 | Each | 2,750 | ₹1,48,500 |
| 1.07 | Modification of electronic control (Air flow monitor) starter system to 5HP manual starter system,make-Havells /Crompton / Anchor with lead 4 core 1.5mm as required. | 11 | Each | 8,200 | ₹90,200 |
| 1.08 | Modification of electronic control (Air flow monitor) starter system to 7HP manual starter system, make- Havells / Crompton/Anchor with lead 4 core 2.5mm as required. | 11 | Each | 8,700 | ₹95,700 |
| 1.09 | Replacement of main cable of fume hoods, Size-10mm 4 core make-Polycab/Hevells/Anchor. | 30 | Meter | 1,050 | ₹31,500 |
| 1.1 | Replacement of Cable connector 100 Amp. | 5 | Each | 1,980 | ₹9,900 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
FumehoodTENDERDOCUMENTmerged.pdf
Tender Documents • 31.35 MB
BOQ_323439.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .