Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹28.8 L
EMD Value
₹57,600
Closing Date
28 Jun 2023, 4:00 pmClosed
Executive Engineer Electric Division Poonch
Executive Engineer Electric Division Poonch
2 Pyt. Saikloo 2. Electricity Pole at Ward No. 4 Khana Qazian Pyt. Kenri Kulani 3. LT Line at Arrah Bial Moh Dha at Ward No. 7 Pyt. Baila 4. HT Line at Gujjar Basti Moh. Seeran Ward No. 1 Pyt. Baila 5. Transformer 25 KVA at Maidan Ward No. 1 Pyt. Gag
2023_PDD_217729_1
e-NIT No.EDP/65 of 2023 dated.21.06.2023
Open Tender
Electrical and Maintenance Works
Turn-key
60 days
Poonch
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Yes
Executive Engineer Electric Division Poonch
₹57,600
Yes
17 Jul 2023
21 Jun 2023
1 Jul 2023
21 Jun 2023
28 Jun 2023
21 Jun 2023
Amount
Erection of 11 KV (HT) Line (Note: For detailed specifications please refer attached SBD which forms a part of the tender)
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard)
G.I Channel/Flat/Angle in shape of Fabricated X-arm Top Bracket, Angle Braces, Clamp etc.
Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 10 KN) (As per recommended IS/REC Standard)
Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard)
Supplying and fixing of Galvanized Nuts and Bolts of sizes.
Supplying and fixing of Galvanzied stay set with 50X8 mm stay clamp, guy insulator (02 nos) anchor plate (200X200x6mm) nut bolts, 2 nos. Turn buckles, 1.80 m long 16mm diameter solid GS Stay rod & 7/3.15 dia GI Stranded wire complete
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing, binding and Jumperig of conductor including joints with PG clamps of required size 30 mm2 ACSR ( Weasel) (As per recommended IS/REC Standard)
Supply and installation of 11 KV Link Set, 3-phase, 100A (As per recommended IS/REC Standard)
Erection of 11/0.433 kV Distribution Transformer (Note: For detailed specifications please refer attached SBD which forms a part of the tender)
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 63 KVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate.(As per recommended IS/REC Standard) (with one year warranty)
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 25 KVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate.(As per recommended IS/REC Standard) (with one year warranty)
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard)
Supply and installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type (As per recommended IS/REC Standard)
Supply and installation of 11 kV Horn, Gap Fuse Set, 3-phase, 100A (As per recommended IS/REC Standard)
Supply and installation of 11 kV Link Set, 3-phase, 100A (As per recommended IS/REC Standard)
Supply and fixing of Un Armoured Single Core PVC Cable 120 mm2 alongwith 12 no. Al. thimble 120 mm2
Supplying and fixing of Galvanized Nuts and Bolts of sizes.
Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard)
Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard)
Supplying and fixing of Angle Belt 1.5 Mtr for the protection of transformer
Supply and fixing of LT Distibution fuse set of standard making using clamps/thimbles with Bolts and washers etc. Complete job as per REC standard (Drilling of holes Prohibited).
Supplying and fixing of Angle Brace for transformer bed
Supplying and fixing of Cross X-mar 2.8. Mtr
Excavation of Earthing Pits of dia = 650 mm and depth= 3000 mm, Supplying and fixing of 3 No. sub station earthing by GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 mm 1 no for neutral earthing and 25X3 mm 2 nos (for 2 Nos transformer body earth, 2 Nos Pole earth, 1 no. LA Earth and 1 no. GO handle earth). (Note: For LA Earth 1 pipe shall be kept separate) GI Nuts, Bolts and Clamps,
Erection of 1kM of LT Line on Conductor, 3-Ph, 4-wire, 2-Ph, 3-wire & 1-Ph, 2-wire (Note: For detailed specifications please refer attached SBD which forms a part of the tender)
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard)
Supply and fixing of Mukky clamps for LT Shackle insulators (As per recommended IS/REC Standard)
Supplying and fixing of Shackle Insulators (polymer) ( 16 KN) (As per recommended IS/REC Standard)
Supplying and fixing of Galvanized Nuts and Bolts of sizes.
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size. 30 mm2 ACSR (Weasel) (As per recommended IS/REC Standard)
Pre, during and post geo tagged photographic evidence consisting of 5X7 inch photographs in coffee table book (Covering each pole/sub station)
SHARAZ AHMED MALIK
AQUIB TRADERS
M/S AL-AQSA TRADERS
MS Khawaja Construction and building
Hi Tech Electrical Works
Madina Electrical Works
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .