| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-Finance | L1 | Accepted-Finance Being lowest bid L1. PNC have been approved by CFA on 12 Mar 2024. | |
| 2 | L2₹33.8 L+₹1.3 L (3.92%)Rejected-Finance | L2 | Rejected-Finance Being higher than L1 Bid. | |
| 3 | Rejected-Technical | - | Rejected-Technical Tech bid rejected by CFA on 13 Dec 2023 | |
| 4 | Rejected-Technical | - | Rejected-Technical Tech bid rejected by CFA on 13 Dec 2023 |
Tender Value
₹31.9 L
EMD Value
₹63,850
Closing Date
30 Oct 2023, 11:30 amClosed
SO-1 (Wks), HQ 5 Sector Assam Rifles
SO-1 (Wks), HQ 5 Sector Assam Rifles
Special repair to roof of existing non-resdl bldg and repair in roof of various accn at Bn HQ Phek at 22 AR (Now 38 AR).
2023_ARMHA_775265_1
VIII.28028/Engr/HQ 5 Sect/2023/06
Open Tender
Civil Works
Works
365 days
Bn HQ at Phek
As per tender documents
2 documents required · 2 mandatory
₹1,000
SO1 (Wks), HQ 5 Sect AR, C/o 99 APO
₹63,850
13 Mar 2024
9 Oct 2023
31 Oct 2023
9 Oct 2023
30 Oct 2023
10 Oct 2023
9 Oct 2023 - 28 Oct 2023
Amount
SCHEDULE ‘A’ PART-I (SPECIAL REPAIR IN ROOF OF VARIOUS ACCN)
Dismantling roofing including ridges, hips, valleys and gutters etc.and stacking the material within 50 metres lead of:G.S. Sheet.
Dismantling roofing including ridges, hips, valleys and gutters etc.and stacking the material within 50 metres lead of:Asbestos cement sheet
Taking out wind ties 30x6mm from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m²
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I.limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m²
Fixing of old wind tie with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand & manufacturer over and including priming coat of ready mixed zinc chromate yellow primer of approved brand.
providing and fixing wind ties of 40x 6 mm flat iron section.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
SCHEDULE ‘A’ PART-II (ROOF TREATMENT OF NON RESDL BLDGS)
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size)
Supply of Water Proofing materials.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N.Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147.The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane 3 mm thick
APS GROUP CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .