Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹40.9 L+₹1.2 L (3.04%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹41.5 L+₹1.8 L (4.63%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹42.3 L+₹2.7 L (6.71%)Rejected-Finance MES CHOWPATTI HASIMARA DIST JALPAIGURI WB PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹43.1 L+₹3.4 L (8.61%)Rejected-Finance OLD HASIMARA PO HASIMARA DISTT ALIIPURDUAR WB PIN 735215 | HASIMARA | ALIPURDUAR | WEST BENGAL | 735215 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
5 Sept 2024, 6:00 pmClosed
GE (AF) HASIMARA
GE (AF) HASIMARA PO-HASIMARA DIST- ALIPURDUAR PIN-735215
REPAIR TO HARD STANDING, PATH, PROVN OF APPROACH PATH ALONGWITH MAIN ROAD AND REPAIR/MAINT OF INTERNAL ELECTRIFICATION INCLUDING REPLACEMENT OF UNSERVICEABLE LIGHTS FITTINGS, REPLACEMENT OF ELECTRICAL FITMENTS, DISTRIBUTIONS BOXES, ALUMINIUM WIRING W
2024_MES_666504_1
C/8797/2024-25/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹80,000
Yes
14 Sept 2024
18 Jul 2024
7 Sept 2024
18 Jul 2024
5 Sept 2024
1 Aug 2024
Amount
Surface excavation not exceeding 30cm deep and averaging 25cm deep and getting out in soft/loose soil, complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed.
M&L for hardcore of gauge not exceeding 63mm but n. exc. 100mm of broken stone or boulder, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C- 2, (using 40mm graded crushed stone aggregatet) as in floors, pavings or plinth protection etc., complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed. ( Note : Consolidation thickness shall be measured for payment.)
M&L for 80mm thick machine pressed precast concrete coloured interlocking paver block any shape and size, fixed with grey cement and pigment confirming to IS 15658-2006, M-40 grade, complete all as specified and directed.
M&L for PCC (1:2:4) type B-1, (using 20mm graded crushed stone aggregate) as in sides of chequered tiles path/ Interlocking paver block etc, rounded or chamfered on edges, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc. 15cm thickness (below or above ground level), incluuding removing of demolished materials n exc 50m from site of work and deposited where directed, complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8), type D-2 (using 40mm graded stone aggregate) as in sub-bases, floors and pavings etc.,complete as specified and directed.
M&L for 15mm thick chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors, with grey cement and pigments, over and including 15mm thick screed bed or bedding layer of CM (1:6), complete all as specified and directed.
M&L for 60mm thick machine pressed precast concrete coloured interlocking paver block any shape and size fixed with grey cement and pigment confirming to IS 15658-2006, M-35 grade, complete all as specified and directed.
M&L for 40mm thick PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) finished even and fair without using extra cement including necessary formwork, complete all as specified and directed.
M&L for plastic dividing strips 38mm width, 1.5mm thick and inserted in position, conform to design, complete all as specified and directed.
M&L for PCC (1:2:4) type B-0, (using 12.5mm graded crushed stone aggregate) as in copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring complete light,fan, plug point & power complete alongwith fittings switches, ceiling roses, tube light fittings, bulk head fitting, regulator, sockets main switches, DB removing materials to store & making good disturbed surfaces of walls/floors, ceiling etc., complete all as specified and directed.
M&L for point wiring complete as specified with 1100 V grade with 1.5 Sqmm single core PVC insulated unsheathed FRLSH cable, copper conductor multistranded drawn in and including concealed PVC conduit not less than 20mm dia, including fittings, including cutting chases on wall for concealed conduit and sinking of CI/pressed steel terminal boxes, 60mm deep, 1.2mm thick for mounting switches, sockets etc with and including 3mm thick plastic laminated sheet cover fixed with brass screws and cup washers duly grouted and pointed with red oxide primer inlcuding PVC insulated FRLSH unsheathed stranded copper conductor of size 1.5 sqmm as earth wire connected to common earth dully for one light point/one fan point controlled by one, one way switches inlcuding making good distrurbed surfaces of wall in CM (1:3) and finished the surfaces as per existing, complete all as specified and directed.
All as per item No 16.00 here-in before but for one switch socket combination 5/6 Amps on independent board, complete all as specified and directed.
All as per item No 16.00 here-in before but for one 3 pin 5 Amp socket outlet on the same board with other switches, complete all as specified and directed.
All as per item No 16.00 here-in before but point wiring with 2.5 sqmm FRLSH copper cable and 2.5 sqmm FRLSH copper cable as earth continuity conductor for one 6 pin, 5/15 Amps switch socket combination on independent board, complete all as specified and directed.
All as per item No 16.00 here-in before but for one light point controlled by two 2 ways switches, complete all as specified and directed.
All as per item No 16.00 here-in before but for one call bell point, complete all as specified and directed.
S&F for switch piano flush button, single pole, one way, 5/6 Amps 240 volts, complete all as specified and directed.
S&F switch piano flush type, single pole, two ways, 6 Amps, complete all as specified and directed.
S&F for bell push, flush type 5 Amps, complete all as specified and directed.
S&F for bell electric, heahy duty, ding dong type, 230 volts, single pole, complete all as specified and directed.
S & F switch socket combination, flush type, 5 pin, type 5/6 Amps, complete all as specified and directed
S & F switch socket combination, flush type, 5/6 pin, type 15/16 Amps, complete all as specified and directed.
S & F socket outlet, flush type, 5 pin 5/6 Amp, complete all as specified and directed.
S & F in repair industrial socket metal clad, plug and socket with MCBs single pole 20 Amp, complte all as specified and directed .
S&F in repair switch, modular type, single pole, one way, 5/6 Amp, one module, complete all as specified and directed.
S & F in repair modular, switch socket combination 5 pin, flush type, 5/6 Amp, 5 in 1, including modular cover plate and frame, complete all as specified and directed
S & F in repair modular, switch socket combination 5 pin, flush type, 5/16 Amp, 5 in 1, including modular cover plate with frame, complete all as specified and directed
S&F in repair switch modular type, single pole, 2 way, 5/6 Amp, one module, complete all as specified and directed
S&F in repair socket outlet modular, 5 pin, 5/6 Amp, flush type, complete all as specified and directed.
S&F in repair flush type bell push, modular type, single pole, 5/6 Amp, one module, complete all as specified and directed.
S&F in repair flush type fan step regulator, modular type, not less than 120 watt two module for ceiling fan 1200/1400mm sweep, complete all as specified and directed.
S&F ceiling rose of size 65 x 50mm, surface bakelite, three terminal, completes all as specified and directed.
S&F LED lights fitting 1x 20 W, 220V, AC, box type with driver, LED lighting fixture with extruded aluminium channel, including LED tube light of 20watt connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down old unserviceable light fittings, completes all as specified and directed.
S&F in replacement bldg security light fitting LED type, 25 watt with all necessary acessories, clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC fixed to wall/ on pole including fixing arrangement with galvanized iron pipe 35mm bore, light grade, brackets, 2 mtr length, bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076, complete all as specified and directed
S & F in replacement angle holder, insulated body, with back plate for conduit fittings, complete all as specified and directed.
S & F water tight bulk head fitting, comprising of connector galvanised cast iron back plate, weather proof enameled gallery, with electronic driver, (latest design), 10 W, upper PVC body, complete all as specified and directed. (Make: Havells Cat Part No. HEXAFT10WLED857SSYMBOPC/Bajaj Cat Part No. BIBWP 10W LED/Crompton Cat Part No. LBHP-10-CDL)
S&F in replacement decorative wall light, gold finish fixture with white glass diffuser and including 9 W LED filament lamp, E27 base, complete all as specified and directed.
S&F in replacement LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V, AC, decorative type with driver, LED tube light of 10watt connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, completes all as specified and directed. (Make : Havells Cat Part No. LUMILINEPLUSBS10WLED865SPCSS/Bajaj Cat Part No. BCLSB 10 WH/Philips Cat Part No. BN021 LED12S 6500 PSU GR)
S & F in repair speed regulator for ceiling fan 1200/1400mm sweep, complete all as specified and directed.
S&F LED luminaire 600mm x 600mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size including taking down old unserviceable luminaire, complete all as specified and directed.
S&F LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down old unserviceable flood light, complete all as specified and directed.
S&F in replacement LED lamp 9 watt white/red/yellow/blue/green colour for angular holder, completes all as specified and directed.
M&L for submain wiring wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, 6.0 Sqmm (nominal area) drawn in and including heavy duty PVC conduit not less than 20mm size including 6.0 Sqmm (nominal area) 1100 Volts grade, FRLSH type, PVC insulated unsheathed multistranded flexible copper conductor cable as continuous earth wire and connecting to common earth dolly including taking down old unserviceable sub-main wiring, complete all as specified and directed. Note:- Three runs of cable and one run of PVC conduit shall be measured as one length of sub main.
M&L for submain wiring wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, 4.0 Sqmm (nominal area) drawn in and including heavy duty PVC conduit not less than 20mm size including 4.0 Sqmm (nominal area) 1100 Volts grade, FRLSH type, PVC insulated unsheathed multistranded flexible copper conductor cable as continuous earth wire and connecting to common earth dolly including taking down old unserviceable sub-main wiring, complete all as specified and directed. Note:- Three runs of cable and one run of PVC conduit shall be measured as one length of sub main.
S&F MCB distribution board (DB), SPN with sheet metal encloser, double door, IP 43 protection, 240 volts, 08 way, single pole and neutral, with 200 Amps rated busbar (as per OEM), neutral link for fixing MCBs/Isolators including taking down old unserviceable MCB DB of any description, completes all as specified and directed.
S&F MCB distribution board (DB), SPN with sheet metal encloser, double door, IP 43 protection, 240 volts, 12 way, single pole and neutral, with 200 Amps rated busbar (as per OEM), neutral link for fixing MCBs/Isolators including taking down old unserviceable MCB DB of any description, completes all as specified and directed.
S&F in repair MCB SPN, 6 to 32 Amps, 240V, 10 KA, 'B' curve, including connection of testing, completes all as specified and directed.
S&F in repair MCB SP, 6 to 32 Amps, 240V, 10 KA, 'C' curve, including connection of testing, completes all as specified and directed.
S&F MCB distribution board (DB) TPN with sheet metal encloser, double door, IP 43 protection, 240 volts, 04 way, single pole and neutral, with 200 Amps rated busbar (as per OEM), neutral link for fixing MCBs/Isolators including taking down old unserviceable MCB DB of any description, completes all as specified and directed.
S&F of MCCB 100 Amps AC 4 pole 415 Volt 16 KA breaking capacity as per IS/IEC 60947-2 with thermal magnetic release including providing new thimble / lugs of suitable size, complete all as specified and directed.
M&L for earthing of galvanised steel earth plate electrode 60cm × 60cm × 6mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work PCC (1:2:6) type C-1 with suitable size of CI cover plate with angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect,including galvanised earth lead wire 4.0mm, 15mm bore (medium grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion including taking out/dismantling of old unserviceable earthing of any description, complete all as specified and as directed. Note :- Proper earthing pit should be provided with pit cover.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), completes all as specified and directed.
S&F exhaust fan, steel body AC, single phase, 230V of size 300mm sweep complete with blades, frame and louvers including cutting wall for fixing the exahaust fan, making good the opening in CM (1:4) and finished the surfaces as per existing and connecting the fan with and including 3 core PVC insulated sheathed flexible copper conductor of suitable size, complete all as specified and directed.
S & F in replacement LED bed side light, antique brass finshed steel bedside cylindrical spot, 10 Watt, suitable for reading, complete all as specified and directed .
Note: An amount of Rs.24,366.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S. NARENDRA KUMAR GARG (BID ID -3075983)
SHRI D P AGARWAL (BID ID -3077876)
BHARAT ELECTRIC (BID ID -3081669)
M/S BIJAY KUMAR SHIVA (BID ID -3076270)
B L SHARMA (BID ID -3076461)
CONSTRUCTION SHELTER (BID ID -3080850)
M/S ROY ENTERPRISE (BID ID -3080919)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .