Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹17.0 L+₹30,584 (1.83%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹17.2 L+₹53,385 (3.20%)Rejected-Finance PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L3 | Rejected-Finance Highest amount quoted | |
| 4 | Rejected-Technical | - | Rejected-Technical Overloaded. Work bal in hand is more than 05 times of tender limit. |
Tender Value
Refer Docs
EMD Value
₹68,500
Closing Date
8 Sept 2022, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
REPAIR/MAINT TO EXTERNAL WATER SUPPLY, DISTRIBUTION SYSTEM INCLUDING PUMP, PANELS, VALVE IN RESTRICTED AND UNRESTRICTED AREA OF DGQA UNITS AT GCF VFJ KHAMARIA AND REPAIR/PREVENTIVE MAINT OF INTERNAL AND EXTERNAL ELECT SUPPLY, STREET LIGHTS IN RE
2022_MES_541706_1
8479/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
D a (ii)
7 documents required · 7 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹68,500
Yes
19 Oct 2022
11 Aug 2022
10 Sept 2022
11 Aug 2022
8 Sept 2022
26 Aug 2022
11 Aug 2022 - 18 Aug 2022
Amount
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr deep for fundations, manholes, laying GI/CI pipes, cable etc n.exc 10Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
All as per Srl item No 1 here-in-before but depth of excavation exc 1.5 mtr but n. exc 3.0 mtr depth.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exce 25Cm thick complete all as specified and directed.
Removing excavated soil to a distance not exce 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
Cutting existing the following cast iron pipes in position for insertion of new pipe/tees, branches etc. complete all as specified.
250 mm bore
200 mm bore
150 mm bore
100 mm bore
Taking up the DI water mains (including all fittings) of size 150 mm dia incuding flanged ends rubber joints with spigot and socket ends and lead joint including burning out joints and recovering lead of size. Note : Excavation/earth work shall be measured and paid separately.
S&F Ducitile iron pipe double flanged ISI marked 150 mm Daimeter,3 - 6 mtr length in Each pipe, 4 mm thickness, finished polished in round shape for drinking water all as specidied and directed by Engr-in-Charge.
M&L for run lead joints for the following size of pipes complete for water mains with spigot & socket pipes and fittings complete all as specified and directed:-
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
S&F the following rubber tyton joint of size :-
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
S&F rubber gasket joint for flanged end pipe & fittings of following size :-
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
S&F in repairs machanical Gypsum joint ISI marked for spigot end pipe of following sizes :-
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
S&F 200/250mm bore spigot/flanged/ socketed CI fittings. such as bends (any type radius and angle), tapers, tees, collars & tail piece socket/flanged/spigot etc complete all as specified.
Dismantling/taking out unserviceable sluice valve of size 80mm to 250mm bore dia by opening/cutting rusted nuts, bolts etc all as specified and directed.
S&F the following CI sluice valves both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 ISI marked complete all as specified and directed. Make : Kirloskar/L&T/Upadhiya
80 mm bore
100 mm bore
S&F the following CI sluice valves both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed.Make : Kirloskar/L&T/Upadhiya
150 mm bore
200 mm bore
250 mm bore
Dismantling/taking out unserviceable air release valve/non return/foot valve/fire hydant valve of any size by opening/cutting rusted nuts, bolts etc all as specified and directed.
Supply and fix CI double end flanged and drilled non return valve of size 200 mm PN-1.6 dia ISI marked. Make : Kirloskar/Upadhyay/L&T
Supply and fix CI double end flanged and drilled non return valve of size 150 mm dia PN-1.6 ISI marked. Make : Kirloskar/Upadhyay/L&T
Supply and fix CI double end flanged and drilled non return valve of size 100 mm dia PN-1.6 ISI marked. Make : Kirloskar/Upadhyay/L&T
Supply and fix CI foot valve, flanged end and drilled of size 150 mm dia ISI marked. Make : Kirloskar/ Upadhyay/L&T
Supply and fix CI foot valve, flanged end and drilled of size 100 mm dia ISI marked. Make : Kirloskar/ Upadhyay/L&T
Supply and fix cast iron double ball air release valves of size 80mm as per IS 14845, PN rating H-7 ISI marked. Make : Kirloskar/Upadhyay/L&T
Cutting of road /hard standing for laying /dismentling of pipe line and making good surfaces matching with the existing surface after laying of pipe line.up to 30 cm.
Dismantling of existing valve pit and M&L for construction of masonry valve pit (as per drawing No CEJZ/TD/819/91 dated 16/04/91) with the following specification :- Excavation/earth work, returning filling, removal of surplus soil, Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 1200 x 1200 x 1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40mmx40mmx5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing.
Dismantling of existing valve pit and M&L for construction of masonry valve pit (as per drawing No CEJZ/TD/819/91 dated 16/04/91) with the following specification:- Excavation/earth work, returning filling, removal of surplus soil, Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 900 x 900 x1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40mmx40mmx5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing.
Taking up or down the following old unserviceable GI Tubing and connections including cleaning for refixing. Note :- Excavation/earthwork shall be measured & paid separately.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100mm bore
Refixing the following old GI Tubing and connections in New or old position (walls, Ceiling, Floors etc) of sizes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bre
Laying only the followiing old serviceable removed GI Tubing from site and connection in New or old position (in trenches) of sizes :-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F the followiing GI tubing medium grade with all fittings and fixed complete laid in trenches of size :-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100mm bore
S&F the followiing GI tubing medium grade with all fittings complete to walls and ceilings or laid in floors of size :
15 mm bore
20 mm bore
25 mm bore
40 mm bore
Taking down/removing the following Unserviceable Gate valve/stop valve from water supply lines, closing the opening with plug or preparing for new as required necessary fittings complete all as specified :-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F the followiing Gun metal Globe or Gate valve with iron wheel head, screwed both ends for iron pipe and fixed with required necessary GI fittings complete :- Make : Kartar/Zolto/Sant/Leader
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Taking down/removing unservieable bib taps 15/20mm bore from pipe line/tanks complete all as specified and directed.
S&F 15mm bore bib tap cast copper alloywith crutch/buterfly handle screwed for iron pipe complete all as specified. Make - Prayag/Polytuff.
S&F 15mm bore bib tap standard of PTMT any colour (minimum wt 15mm - 90gms) screwed for iron pipe complete all as specified. Make - Prayag/Polytuff.
Cutting the following existing galvanised iron pipe in position for insertion of new pipe/tees, branches etc.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
S&F in replacement the following stainless steel spindle suitable for following dia of sluice valve complete with stainless steel nut and threading as per sample & directed by Engr-in- Charge :-
250 mm bore sluice valve
200 mm bore sluice valve
150 mm bore sluice valve
100 mm bore sluice valve
80 mm bore sluice valve
S&F in replacement Digital water leval indicator system 150 mm size digit direct display, operated on 230v Ac, suitable for upto 20 metre height over head Reservior/underground sump of any capacity, preadjustable alarm for upper & lower level, temp range -5 to 50 degree, humidity up to 90% RH, reset push switch for silent the alarm including 4 core 1.5 sqmm copper cable. Make: SURYA ELECTRONICS & CONTROLS / RECTRONIC DEVICE & CONTROLS.
Taking up Submersible Pump assembly including column pipe approx 50 to 70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 17.5HP/15 HP Pump Set . (i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3phase ,taking out burnt winding wire, with & including PVC insulated water proof copper wire with winding wire of appropriate gauge and turn, providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 17.5/15 HP submersible pump of any make including carrying out painting by two coats of synthetic enamelled paint over a coat of primer, assembling the pump and motor including testing complete all as specified and directed.
Taking up Submersible Pump assembly including column pipe approx 50 to 70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 12.5/10 HP Pump Set .(i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3 Phase ,taking out burnt winding wire, with & including PVC insulated water proof copper wire with winding wire of appropriate gauge and turn,providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 12.5/10 HP submersible pump of any make including carrying out painting by two coats of synthetic enamelled paint over a coat of primer, assembling the pump and motor including testing complete all as specified and directed.
Taking up Submersible Pump assembly including column pipe approx 50 to 70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 7.5/5 HP Pump Set .(i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3 Phase ,taking out burnt winding wire,with & including pre insulated water proof copper wire with using winding wire of appropriate gauge and turn, providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 7.5/5 HP submersible pump of any make including carrying out painting by two coats of synthetic enamelled paint over a coat of primer, assembling the pump and motor including testing complete all as specified and directed.
Note for item No 39 to 41 (i) Cost of disconnection of electric connection from LT control panel & starter of submersible pumping set & reconnecting with existing pipe and making electrical connection with panel board & starter shall be included in the quoted rate of these items. (ii) Cost of lowering of submersible pump set of any size after repairs and re-connecting with existing pipe shall be included in the quoted rate of these items. (iii) Cost of spare parts shall be included in the quoted rate of these items. (iv) The contractor shall be repair the submersible pump and motor within 72 hours after receiving the complaint failing which recovery/penalty shall be imposed @ Rs 500.00/day. The same shall be recovered from the RAR/FB.
Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Vlots, 50 Cycles, and taking out to local workshop induction motor 60/50/40 HP for repair purpose including complete cleaning, varnishing ,insulation and greasing and including shifting back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. Note- Rewinding will be measure & paid seperately under relavant item of sch.
Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Vlots, 50 Cycles, and taking out to local workshop induction motor 12.5/15/25 HP for repair purpose including complete cleaning, varnishing, reinsulation and greasing and including shifitng back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. Note:- Rewinding will be measure & paid seperately under relavant item of sch.
M&L for Rewinding the motor with super enamelled copper winding wire with appropriate same gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations as directed by Engr-in-Charge. Make:Atlas/BWC/Swastik/ Chetak
Taking down unservicable existing motor starter of any size/capacity.
M&L Fully Automatic Star Delta Motor starter 50 HP in sheet-steel enclosure type ML with single phase protection feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 28-42 complete all as specified. (Make : L&T cat no SS 91730 or Equivalent OF SIEMENS/schneider).
M&L Fully Automatic Star Delta Motor starter 35 HP in sheet-steel enclosure type ML with single phase protection feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 22-32 complete all as specified. (Make : L&T cat no SS 91730 or Equivalent OF SIEMENS/schneider).
M&L Fully Automatic Star Delta Motor starter 25 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 13-21 complete all as specified. (Make : L&T cat no SS 91855 or Equivalent OF SIEMENS/schneider).
M&L Fully Automatic Star Delta Motor starter 15 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 11-18 complete all as specified. (Make : L&T cat no SS 96257 or Equivalent OF SIEMENS/schneider).
M&L Fully Automatic Star Delta Motor starter 12.5 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 9-14 complete all as specified. (Make : L&T cat no SS 96257 or Equivalent OF SIEMENS/schneider).
M&L Fully Automatic DOL Motor starter 7.5 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 13-22 complete all as specified. (Make : L&T cat no SS 96228 or Equivalent OF SIEMENS/schneider).
M&L Fully Automatic DOL Motor starter 3 HP in sheet-steel enclosure type MF-1. feature (Motor Rating AC-1 Duty, 230V, 50Hz, 1-Ph) and Relay Range 10.5-17.5. (Make : L&T cat no cs90319kodo or Equivalent OF SIEMENS/schneider).
Taking down unservicable existing cable from motor/pannel to starter any size/capacity.
S & F PVC Insulated unsheathed cable 10 sq mm, 3 core, multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified. Make : Policab/Havells/Finolex
S&F in repairs MCCB 250 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T / Schneider/Hager
S&F in repairs MCCB 200 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T / Schneider/Hager
S&F in repairs MCCB 160 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T / Schneider/Hager
S&F in repairs MCCB 125 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T / Schneider/Hager
S&F in repairs MCCB 100 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T / Schneider/Hager
S&F in repairs MCCB 63 A 16 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T / Schneider/Hager
M&L draining water from OH reservoirs not exc. 18 Mtr head/staging, and cleaning internal portion of tank (bottom and walls) by means coir / wire brush etc. and wash the internal portion of tanks by using bleaching powder @ 25 grams per 1000 Ltrs of water after removing sludge and mud etc to a distance not exc 50 mtr including one coat of synthetic enamel paint on all steel surfaces such as ladder, railing, inlet & over flow CI pipes connected sluice valves of the respective OH tanks/ground level reservoir etc writing letters with white paint (date of cleaning and capcity of tank) on black painted surface of tanks all as directed by Engineer-in-Charge.
100000 gallons capcity
50000 gallons capcity
All as per srl item No 61 above but exceeding 18 Mtr head / staging for the following :
100000 gallons capcity
All as per srl item No 61 above but semi underground reservoir/sump of 200000 gallons cap each tanks devided in two poriton
All as per srl item No 61 above but semi underground reservoir/sump of 100000 gallons cap each tanks devided in two poriton
All as per srl item No 61 above but semi underground reservoir/sump of 50000 gallons cap each tanks devided in two poriton
All as per srl item No 61 above but semi underground reservoir/sump of 25000 gallons cap each tanks devided in two poriton
S&F in repairs15 HP submersible pump set suitable for 150-200 mm boreing, 1-447 mtr head, 30-740 LPM discharge, including all accessories all as specified and directed by Engr-in-Charge. Make KIRLOSKAR 15 HP BOREWELL SUBMERSIBLE PUMP SET 100HHN-1515 or CROMPTON 15HP BOREWELL SUBMERSIBLE PUMP 8W3K15D-W or Havells Submersible Pumpsets Water Filled Motor H6W6M3F150T 11.2 kW 15 HP.
S&F in repairs10 HP submersible pump set suitable for 150 mm boreing, 5-306 mtr head, 60-2400 LPM discharge, including all accessories all as specified and directed by Engr-in-Charge. Make KIRLOSKAR 10 HP BOREWELL SUBMERSIBLE PUMP SET KS6F-1006R orCROMPTON 10 HP SUBMERSIBLE PUMP SET 650CS100-1010 or Havells Submersible Pumpsets Water Filled Motor 7.5 kW 10 HP.
S&F in repair centrifugal pump 1 HP, single phase, 9-22 mtr head, brass impeller, with complete accessories all as specified and directed by Engr-in-Charge. Make CROMPTON 1 HP MBG12 CENTRIFUGAL WATER PUMP or KIRLOSKAR 1 HP 210V 0.75 KW SINGLE PHASE MONOBLOCK PUMPS KDS-128+ or V-GUARD MONOBLOCK PUMP NEON-WSF100
Note :- Item No 62 top 64 catered against BER items
Supply and fix in replacement Altoch Dosing system consisting of 100littres PE/FRP Tank with PE/FRP lid and level gauge alongwith Agitator(1280 RPM) with shaft and blade (FRP/Epoxy coated)/plastic mounted on Tank lid having port hole for pouring Altoch and water as required. Lid having provision for mounting Dosing Pump on lid. Agitator motor 90 Watts,1440 RPM, 230 Volts 50 Cycles, 0.2 Amp and having speed controller to reduce speed up to 800 RPM complete all as specified and directed.
Supply and installation in replacement High pressure SingleHead Gear Motored adjustable Dosing pump set,uneffected on dry running having no loss of prime, independent of back pressure and able to handle both chemical solutions as well as suspensions, 230 volts 50 cycles AC, 44 RPM, 1/30 fraction H.P having output 2US GPD to 40 U.S GPD complete with accessories ie lead tubing, connecting nuts, injecting check valve, ferrules etc complete all as specified.
Dismantling of existing u/s steel LT poles of any size & type from its position carefully and removing from the site and including necessary excavation and earth work in any soil/strata, demolition of concrete, disconnection of conductor from pole etc. complete all as directed.
Supply and install steel, tubular swaged poles complete with cast iron base plate, finial taper plug nuts and taper plug , bolts, nuts and screws as specified type 410-SP- 31 (9.0 m long) complete all as specified and directed. Note : Excavation, earth work shall be measured and paid separately.
M&L unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified. Note : Measurement shall be done after puning down of sand.
M&L Brick covering with width equal to length of bricks as mechanical protection to cable with well burnt sub class `B` old size bricks laid dry and flat complete all as specified and as directed.
M&L for Plain cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate for coping of pole with and including formwork complete all as specified and directed.
S&F in repairs 1100 Volts grade line composite phase separators, moulded & bolted type as per IS 1445 - 1997 suitable for the following :-
Taking down and S&F inreplacement XLPE insulated armoured and PVC sheathed "heavy duty" electric cable with aluminium conductor 1100 volts grade laid in trenches, passing through pipes /ducts including testing complete of following cross sectional area of the following sizes:- Note:- Rate is inclusive of cable gland & cable lugs. The contractor shall be used old cable route indicator retrietive from item No 33 to 35 above. Fixing cost for the same shall be included in the quoted rates of these items.
2 core, 4 sqmm cross sectional area
2 core, 6 sqmm cross sectional area
2 core, 10 sqmm cross sectional area
4 core, 16 sqmm cross sectional area
3.5 core, 25 sqmm cross section area
3.5 core, 35 sqmm cross section area
3.5 core, 50 sqmm cross sectional area
S&F in repairs 50mm bore, GI steel tubing "light grade" for cable protection passing under road /floor or for fixing to poles complete all as specified and as directed. Make :- JINDAL/ ZENITH/ TATA.
Taking down partly unserviceable/unserviceable security/street/gate/flood light fittings from poles/towers/ Perimeter Fencing of any type upto 9 m height by manual or mechanical means and for necessary repair and make srviceable as per complaint given by department (E/M service cell) through job card/complaint register on day to day basis all to the satisfaction of Engr-in-Charge & complete all as specified and directed Note :- Ballast,Lamp holder, capacitor, ignitor, covers ,lamps and LED drivers of required wattage/type shall be measured and paid separately.
Fixing only repaired serviceable fitting of any size, and any make complete all specified and directed by Engr-in-Charge
S&F in repairs Electronic driver suitable for LED fitting 25 watt. Make : bajaj/Wipro/Havells/ Crompton
S&F in repairs Electronic driver suitable for LED fitting 45 watt. Make : bajaj/Wipro/Havells/ Crompton
S&F in repairs Electronic driver suitable for LED fitting 60 watt. Make : bajaj/Wipro/Havells/ Crompton
S&F GI pipe bracket made of light Grade tubing of size 40 mm bore, duly bended by hot forgoing length 1.20 mtr including two sets of clamps made of 30mm x 5mm thick Flat iron with GI bolt,nuts & washers complete all as specified and directed.
S&F LED street light lumanaries of size 90 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection Make: Havells Cat Pt No ENDURAPEARLPLUSSL 90WLED757PASYTOPCASTHO or equivelent of Philips, Bajaj, CG,Orient.
S&F LED street light lumanaries of size 80 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection Make : Havells Cat Pt No ENDURACITYLINERNEOMPSL80WLED757PASYBOTG equivelent of Philips, Bajaj, CG,Orient.
S&F LED street light lumanaries of size 60 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection Make: Havells Cat Pt No ENDURAPEARLNEOSL60WLED757PASYTOPC equivelent of Philips, Bajaj, CG,Orient.
S&F LED street light lumanaries of size 45 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection Make: Havells Cat Pt NoENDURAPEARLNEOSL45WLED757PASYTOPC equivelent of Philips, Bajaj, CG,Orient.
S&F LED street light lumanaries of size 25 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection Make: Havells Cat PtENDURAPEARLSL25WLED757SASYTOPCMP equivelent of Philips, Bajaj, CG,Orient.
S&F in repairs post of lantern fitting made out of black ABS plastic spigot & spun alluminium funnel shaped with clear acrylic cover suitable for 1x45w LED lamp including fitting complete all as specified. Make : Havells Cat JUPITERMAXIPT50WLED757PSYMTOPC equivelent of Philips Philips, Bajaj, CG,Orient.
S&F in repairs Post of lantern fitting made out of polycarbonate mateial suitable for 1X25w LED lamp including lamp complete all as specified. Make : Havells Cat JUPITERMAXIPT50WLED757PSYMTOPC equivelent of Philips, Bajaj, CG,Orient.
S&F in repairs sheet metal box of size 60cm x 60cm x 20 cm for fixing street light timer switch , frame pole mounted type fabricated out of 1.6 MM sheet steel including powder coat painting over a coat of red oxide primer including ,consisting of the following :- (a) MCCB 63 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM97919OOH2OG /Legrand cat no-420013/schneider cat no-LV510315 - 2 nos (b) Astronomical, Multifunctional digital time swithces cat no 004767 of legrand or equivalent of L & T cat no- T2 DD T7/MDS/GIC - 1 no. (c )Power contactor ML-4 , 3 pole rating not less than 70 A with 230 coil make L&T/SEIMENS - 1 no. (d) Internal wiring and, clamp - 02 no.made out of 40x5mm flat & angle 40x40x5mm -0.90m long -2Nos. (e ) MCB SP 6 amps-1 No
M & L earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized streep 32x6 mm by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-3 of SSR-2009 (part-I)
S&F in repairs PVC junction box IP 65 Protection of size 0.200 x 0.250 x 0.115 complete with 1 Nos of MCB SP 2.5 Amps & 4 way industrial connector including Clamp made out of MS flat 30X5 mm, connection from junction box to street light fitting with three single core PVC insulated & PVC sheathed wire 2.5 Sqmm copper. Make of Box- SPELS BERG/ SINTEX/ HENSEL
S&F in repairs PVC insulated 3 core 2.5sqmm multistranded COPPER conductor for connection of Security light from JN BOX to Security light /OH conductor to security light all complete as specified and directed. Make: finolex/plaza/havells/CCI.
S&F in repairs PVC insulated 3 core 1.5sqmm multistranded COPPER conductor for connection of Security light from JN BOX to Security light /OH conductor to security light all complete as specified and directed. Make: finolex/plaza/havells/CCI.
S&F in repairs Astrorex D-22, Multifunctional digital time swithces Make : Legrand/L & T/ MDS/ GIC
S&F in repairs MCCB 200 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : L&T / Schneider/Hager
S&F in repairs MCCB 160 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : L&T / Schneider/Hager
S&F in repairs MCCB 125 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : L&T / Schneider/Hager
S&F in repairs MCCB 100 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : L&T / Schneider/Hager
S&F in repairs MCCB 63 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified. Make : L&T / Schneider/Hager
S&F in repairs ON LOAD change over switch 4 pole 200amps with sheet metal enclosure. Make : L&T schneider/Legrand
M&L for preparation for surface of existing steel poles including cross arms, nuts, bolts, for painting LT pole 7.5 mtr long above ground level and applying one coat of approved quality of aluminum paint all as directed by Engr -in-Charge.
Labour for cutting the tree branches passing near the HT /LT OH line of width/ girth not more than 30cm upto 3 meter distance from adjacent pole or four/two pole structure all as specified and directed by Engr-in-Charge. Note : (i) Each span having 50 mtr distance approximately. (ii) All cutting branches of trees shall be thrown away /burnt at approximately 200 to 500 mtr away from site.
Repair of LT electric control panel board, cleaning inside with blower, servicing tightening all electrical connections/ contacts points, replacing defective locking clips thimble and making it serviceable with inter locking wiring including welding , painting and replacement of the defective parts and refixing back in its existing position complete all as specified and directed. Note: Defective parts shall be measured and paid separately.
Surface dressing by cutting grass, thorn bushes and congress grass upto the root level surrounding the installation incl the same not less than 200 mtr away all as directed by Engr-in-Charge.
S&F LED flood light lumanaries of size 160 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection Make: Havells Cat Pt JETAIRISFLS 160WLED757PWBLT G equivelent of Philips, Bajaj, CG, Orient.
S&F LED flood light lumanaries of size 180 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection Make: Havells Cat Pt JETA VALOURFL180WLED757PINTNBLT G, Bajaj, CG, Orient.
Schedule of credit amount of Rs. 3,05,324.50 to be deducted during AOC
Goodluck Enterprises
shri krishna traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .