Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹91.0 LAccepted-AOC VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹95.2 L+₹4.2 L (4.62%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹1.1 Cr+₹21.2 L (23.3%)Rejected-AOC 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹1.2 Cr+₹30.6 L (33.6%)Rejected-AOC AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹1.3 Cr+₹42.0 L (46.1%)Rejected-AOC 1201 1202 12TH FLOOR TOWER B MILLENIUM PLAZA SECTOR 27 VILLAGE GURUGRAM GURGAON HARYANA | GURUGRAM | GURUGRAM | HARYANA | 122002 | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
26 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Chandigarh
HQ CWE (AF) Chandigarh PIN-160003
PROVISION OF MANOEUVERING SPACE AROUND THE SWTS AT AF STN ADAMPUR
2024_MES_643285_1
CWE/AF CHD/ADM/T-35/2023-24
Open Tender
Civil Works
Item Rate
270 days
Adampur
As per NIT
8 documents required · 8 mandatory
₹1,000
GE(AF) Adampur
₹2.1 L
6 Jun 2024
20 Feb 2024
2 Apr 2024
20 Feb 2024
26 Mar 2024
12 Mar 2024
Amount
Excavation over area n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed.
Rolling and consolidating formation surfaces in cutting to the required level, gradient or camber with power roller exceeding 8 tonne and not exc 12 Tonne to achieve 98% Procter Density with and including watering as necessary complete all as specified and as directed.
M&L for Laying and compacting 200 mm thick (compacted thickness) Granular Sub Base Course (GSB) grading as per Grade I as specified in Table 400-1 of Morth specifications for Road and bridge works-2013, in two layers 100 mm each over compacted sub grade with natural sand, crushed gravel, crushed stone, crushed slag, or combination there of as per the grading required. Materials shall be mechanically mixed, spread and levelled on the sub grade by using motor grader of adequate capacity, Consolidating and rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density to required gradient and camber with finished surface tolerances as per Table 900-1 of MoRTH specifications for Road and Bridge works- 2013 complete all as specified and as directed.
M&L for Proving and laying Dry lean concrete (DLC) 100 mm thick of aggregate gradation as per table 1 of SP 49:2014 having 7 days average compressive strength not less than 7 MPa. Minimum cement content not less than 140 kg/Cum. DLC shall be mixed in Batching Plant, transported to site and laid by electronic sensor paver including spreading and compacting using high amplitude tamping bars of paver (initial compaction) further by double drum smooth wheeled vibratory rollers with 80-100 KN static weight to achieve minimum Dry Density not less than 98% of maximum dry density, including necessary steel form work, spreading, rolling and consolidating to required gradient and camber for acheving necessary finishing etc, tolerances shall be as per Table 900-1 of MoRTH specifications for Road and Bridge work 2013.7 MPa. complete all as specified and as directed.
M&L for 10 mm thick sand cushion with clean river sand duly clear of residual, organic and deleterious materials spread evenly to uniform thickness laid over DLC layer complete all as specified and as directed.
Supply and laying 400 micron thick HDPE sheet with maximum standard width available as approved by the GE without joints Manufactured by multilayer technology using 100% Virgin raw material, confirming to IS:10889:2004, water proof, wrinkle free without puncture having minimum weight 390gm/sqm laid over sand cushion with and including all necessary cutting and wastage, over lap shall not be less than 300 mm between adjacent strips and at transverse joints complete all as specified and as directed. Note: Company Loga, IS Code and batch No shall be marked on HDPE Sheet at every 2 meters.
M&L for 225 mm thick Pavment Quality Concrete (PQC) of minimum 28 days field Flexural strength of 45 Kg/sqcm or 4.5 Mpa, using aggregate gradation as per table 3 of IRC 15-2017, coarse aggregate of clean, hard strong, dense, non-porous and durable pieces of crushed stone or gravel, fine aggregates of clean natural sand or crushed stone sand or combination of both using minimum 360 kg/cum of cement mixed with Non Circular fibre virin synthetic fibre of 12-18 mm length, specific gravity 1.34 to 1.39, UV stable, alkali resistant, with equivalent dia 15-40 micron, minimum melting temperature as 240 degree c and minimum tensile strength of 300 Mpa and at the rate as specified by the manufacturer. PQC laid, spread and compacted with slip-form paver of minimum 7.50 m width, including curing and tining by Texturing cum curing machine. Required surface texturing shall be done as specified in Clause 10.1.14 and Table 9 of IRC:15-2017 complete all as specified and as directed. Note: Non Circular fibre shall be measured and paid seprately.
Supply only polyster triangular/non circular fibers having tensile strength 4000-6000 kg/sqcm and melting point > 250 C)[email protected]% by weight of cement in controlled cement concrete complete all as specified and as directed.
M&L for Forming 25 mm wide expansion joints in concrete slab for full depth of PQC. Early entry saw and subsequent cutting by using diamond bit cutter of appropriate size, making straight and smooth edges, Joints cleaned throughly with application of compressed air and shall be made dry, (vacuum cleaned) and free of dirt, oil, vegetation and other debris. The joints then be filled with pre-molded 25 mm thick compressible polyethylene closed cell type filler board as specified. Appling two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes (before placing the approved quality backup rod and pouring the sealant), placing of closed cell, medium density, crossed linked polyethylene foam backup rod 30 mm dia, over filler board and filled with polyurethane based sealant complying with BS-5212, BS 4254 and EN-141875-2003 with Minimum Movement Accommodation Factor (MAF) of + 30% having minimum 10 year performance guarantee. (Sealent shall be filled by applying masking tape on the edges of joints ( to avoid accidential slippage of sealent on top surfaces and to give neat finish) and removing the masking tape after filling of sealent complete as specified and as directed.
M&L for Cutting of construction joints 25 mm deep and 10 mm wide by using diamond bit cutter of appropriate size, making straight and smooth edges, Joints cleaned throughly with application of compressed air and shall be made dry, (vacuum cleaned) and free of dirt, oil, vegetation and other debris. Applying two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes (before placing the approved quality foam backup rod and pouring the sealant), placing of polyethylene foam backup rod 12 mm dia, filled with polyurethane based sealant complying with BS-5212, BS 4254 and EN-141875-2003 with Minimum Movement Accommodation Factor (MAF) of + 30% having minimum 10 year performance guarantee. (Sealent shall be filled by applying masking tape on the edges of joints ( to avoid accidential slippage of sealent on top surfaces and to give neat finish) and removing the masking tape after filling of sealent complete as specified and as directed.
M&L for Forming dummy/contraction joint with an initial saw cut of 3 mm soon after the concrete has set, upto a depth of 1/3 rd to 1/4 th thickness of the slab, widening the first saw cut to 6 mm and 24 mm deep by using diamond bit cutter of appropriate size, straight and smooth edges, Joints cleaned throughly with application of compressed air and shall be made dry, (vacuum cleaned) and free of dirt, oil, vegetation and other debris. Applying two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes (before placing the approved quality foam backup rod and pouring the sealant), placing of polyethylene foam backup rod 8 mm dia, filled with polyurethane based sealant complying with BS-5212, BS 4254 and EN-141875-2003 with Minimum Movement Accommodation Factor (MAF) of + 30% having minimum 10 year performance guarantee. (Sealent shall be filled by applying masking tape on the edges of joints ( to avoid accidential slippage of sealent on top surfaces and to give neat finish) and removing the masking tape after filling of sealent complete as specified and as directed.
M&L for Painting 2 mm thick of thermoplast fluorescent paint colour white or golden yellow or any other shade confirming to BS standard 3262 with 20% glass beads (inter mixed) applied hot with automatic (commercial) machine drive in strips after preparation of surfaces as per manufacturer's instructions & according to the specifications laid down by IRC * MOST (Ministary of surface Transport) specifications 2001 (4th revesion), making lines, broken lines/dashes, arrows etc, on road and other like surfaces exceeding 10cm but not exceeding 20 cm in width or girth, complete all as specifed and as directed.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specifed and as directed.
M&L for 300 mm thick Moorum filling in floors or pavings, (for berms of roads) laid in layers n.exc. 15 cm thick, spread, levelled and rolled and consolidated to required gradient and camber using earth compactor of min 8 to 15 ton complete all as specifed and as directed.
Removal of surplus soil excavated material) to distance 250 mtr but n exc 500 m and depositing where directed at a level n exc 1.5 mtr above the starting point complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering & well ramming in layers n. exc 25 cm in soft/loose soil complete all as specifed and as directed..
M&L for PCC 1:3:6 type C-2 using 40 mm gradded stone aggregates as in surface channels and drains complete all as specifed and as directed.
M&L for cement concrete (1:2:4) type B0 using 12.5 mm graded stone aggregate as in copings of drain etc including weathering, slightly rounded or chamfered angles and throating etc complete all as specifed and as directed.
M&L for use and waste of formwork to faces of PCC drain, vertical or to batter, rough finished surfaces of concrete flat complete all as specifed and as directed.
M&L for Brick work in cement mortar 1:4 (using sub class ‘B’, old size bricks), straight or curved on plan to any radius as in half brick thick walls complete all as specifed and as directed.
M&L for Brick work using sub class ‘B’ bricks (old size) straight or curved on plan exceeding 6 metre mean radius, built in CM (1:4) complete all as specifed and as directed.
M&L for Flush pointing to brick walls in cement mortar (1:3) complete all as specifed and as directed.
Excavaton in trenches n.exc 1.50mtr wide and n.exc 1.50mtr in depth for foundations etc and getting out in soft/loose soil complete all as specifed and as directed.
M&L for Construction of Soakage well (size 3.00 m dia x 6.00 m effective depth), excavation in any type of soil, foundation in PCC 1:3:6 type C2 using 40mm graded stone aggregate, walls of honey combed masonry with top ring of M-25 (Design Mix) concrete including interceptiing chamber and screen chamber made of brick masonry in CM 1:4, RCC cover slab in M-25/SFRC cover, inter connecting pipes of RCC /DWC, well shall be filled with bricks batscomplete all as speciified and as shown on drawings. Note: Drawing No CEJZ/STD-301/90 sheet No 1/4 to 4/4 dt 16.06.90 shall be followed.
M&L for Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete or in sub base of floors complete all as specified and as directed.
M&L for Plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete or in sub base of floors complete all as specified and as directed.
M&L for RCC hume pipe, class NP-2, 450 mm dia bore of pipe, laid and jointed with collars complete all as specified and as directed.
M&L for Brick work using sub class ‘B’ bricks (old size) straight or curved on plan exceeding 6 metre mean radius, built in CM (1:6) complete all as specified and as directed.
Removal of excavated material exc 500 m but not exc 1.0 Km and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
ELECTRA ENGINEERS
KULWANT SINGH
siddharthenterprises
Som Projects Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .