Loading…
Loading…
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
7 Oct 2026, 6:00 pm
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh post Hyderabad-500058
REPAIR/MAINTENANCE OF UNSV INTERNAL WIRING ELECTRICAL FITTINGS, HIGHWAY LIGHTS, REPAIRS OF CEILING/EXHAUST FANS IN DMRL AND NEWLY TAKEN OVER FROM CCE OF AMCC/MAIN BLDG DMRL AT KANCHANBAGH, HYDERABAD.GH, HYDERABAD
2026_MES_789883_1
8278
Open Tender
Civil Works
Item Wise
180 days
GE I R and D Kanchanbagh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹79,000
Yes
17 Sept 2026
17 Sept 2026
9 Oct 2026
17 Sept 2026
7 Oct 2026
1 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and Labour for sub main wiring with 2 runs of 2.5 Sqmm single core PVC insulated unsheathed FRLS copper cable 1100 Volts grade multistranded drawn through non metallic rigid PVC conduit ISI marked 25 mm dia including conduit accessories concealed/surface type on walls, roof, floors etc including one run of 2.5 Sqmm PVC copper conductor as earth continuity wire including taking down unserviceable sub main wiring including conduit all as specified and directed.
Note : 2 Runs of 2.5 sqmm cable 1 run of 2.5 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment. | 180 | RM | - | - |
| 2 | All as per srl item No. 1 here-in-before but with 2 runs 4 sqmm including 1 run of 4 sqmm PVC copper conductor FRLS cable as earth continuity wire in not less than 25mm dia ISI marked PVC conduit..
Note : 2 Runs of 4 sqmm cable 1 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment. | 180 | RM | - | - |
| 3 | All as per srl item No. 1 here-in-before but with 2 runs 6 sqmm including 1 run of 6 sqmm PVC copper conductor FRLS cable as earth continuity wire in not less than 25mm dia PVC conduit.
Note : 2 Runs of 6 sqmm cable 1 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit for the purpose of payment. | 120 | RM | - | - |
| 4 | All as per srl item No. 1 here-in-before, but sub main wiring with 4 runs of 4sqmm with 2 run of 4 sqmm copper conductor FRLS as earth continuity wire in not less than 25mm dia PVC conduit.
Note : 4 Runs of 4 sqmm cable 2 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment. | 120 | RM | - | - |
| 5 | All as per srl item No. 1 here-in-before, but sub main wiring with 4 runs of 6 sqmm with 2 run of 6 sqmm copper conductor FRLS as earth continuity wire in not less than 25mm dia PVC conduit.
Note : 4 Runs of 6 sqmm cable 2 run of 6 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment. | 120 | RM | - | - |
| 6 | All as per srl item No. 1 here-in-before, but sub main wiring with 4 runs of 10 sqmm with 2 run of 10 sqmm copper conductor FRLS as earth continuity wire in not less than 25mm dia PVC conduit.
Note : 4 Runs of 10 sqmm cable 2 run of 10 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment.
Make for Item No 1 to 6 :
For Copper wire : Finolex/Nicco/Havells/Gloster/KEI or its equivalent
For PVC conduit : Sudhakar/Polyplast/Supreme/GM or its equivalent
Make of Gang Boxes: GM/Havells/Legrand or its equivalent | 60 | RM | - | - |
| 7 | Taking down old unserviceable point wiring (Light, Fan, Socket or power) complete including fixture and fittings such as switches, ceiling roses, regulators, sockets, light fittings etc and making good to the disturbed surfaces of walls,ceilings and floor etc complete all as directed | 520 | Point | - | - |
| 8 | Material and labour for point wiring complete with ISI marked 1.5 Sqmm PVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc, concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etc including PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for and connecting up complete for the following:-
One light/ fan point controlled by one, one way switch | 300 | Point | - | - |
| 8.01 | One light point controlled by one, two way switch | 10 | Point | - | - |
| 8.02 | One 5 Amps socket point on independent board. | 30 | Point | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
BOQ_885453.xls
BOQ • 0.34 MB
Tenderdocument.pdf
Tender Documents • 1.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .