Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹43.6 L+₹59,980 (1.39%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹45.9 L+₹2.9 L (6.66%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹46.2 L+₹3.2 L (7.41%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹47.0 L+₹4.0 L (9.26%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
12 Feb 2025, 6:00 pmClosed
GE (WEST) LUCKNOW
GE (WEST) LUCKNOW PIN 226002 C/O 56 APO
REPAIR/ MAINT OF LIGHTING CONDUCTOR METER BOX EARTHING AND CONNECTED WORKS UNDER GE (WEST) LUCKNOW
2024_MES_680768_2
GE/W/LKO/84 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
LUCKNOW
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (WEST) LUCKNOW
₹1 L
Yes
17 Mar 2025
28 Jan 2025
14 Feb 2025
28 Jan 2025
12 Feb 2025
29 Jan 2025
28 Jan 2025 - 28 Jan 2025
Amount
Taking down and dismantling of DB TPN /SPN DB of any type size and model removing of unserviceable spares / accessories for replacement of Bldg VTPN DB/SPN DB /MCCB and MCBs of any size, type and model to existing of any type and any size, complete all as specified and directed.
Taking down and dismantling of meter board of any type and any size and removing of unserviceable spares / accessories for replacement of Bldg meter bpoxes of any size , type and model to existing of any type and any size, complete all as specified and directed.
Taking down carefully copper/aluminum sub main wiring including teakwood batten/conduit and making good the disturbed surface of walls, complete all as specified and directed.
S&F MCCB sheet metal enclosure Frame F1 for suitable to installed 63A to 100A MCCB, suitable for isolation with suitable size to fix on wall/floors in standard steel sheet flush mounting type factory fabricated complete confirming to IP 42/43 without MCCB complete all as specified and directed.
S&F in repair MCB, single pole C, 240 Volts, 06 to 32 Amps,10Ka complete all as specified and directed.
S&F in repair MCB, single pole & neutral C, 240 Volts, 32 to 40 Amps,10Ka complete all as specified and directed.
S&F in repair MCB Three Pole & Neutral C, 415 Volts, 63-100 Amps,10Ka complete all as specified and directed.
S&F in repair MCCB 63-100 Amps 415 volts, 4 Pole 16 KA breaking capacity complete all as specified and directed.
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 12 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, IK09, True IP 43 (with PU Gasket) with test certificate factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 8 way 240 Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, IK09, True IP 43 (with PU Gasket) with test certificate factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
S&F in repairs double door VTPN 4 way double door suitable for 4 pole MCCB 63-125A, 415 V as incoming & SP/TP MCB as outgoing 200 Amps rated Busbar, inter connection link, cable ties,earth bar IK09, True IP 43 (with PU Gasket) with test certificate etc incl necessary civil works and electrical connections with suitable lugs/spreader links complete all as specified and directed by Engr-in-charge. ( Note: MCCB & MCB to be measured and paid seprately).
S&F sheet metal enclosure for MCB DB double door type, triple pole and neutral 4 way 415Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, IK09, True IP 43 (with PU Gasket) with test certificate ,factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
M&L in replacement for Submain wiring with two single core unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 4.0 sqmm nominal cross sectional area Multi-stranded copper conductor and one single core green unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 4.0 sqmm Multi-stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia including all conduit and fixing accessories existing in wall including cutting chases in wall and making good to the disturbed surface to match the existing colour code with 1mm putty taking out the unserviceable sub main wiring complete all as specified and directed
M&L in replacement for Submain wiring with two single core unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 6.0 sqmm nominal cross sectional area Multi-stranded copper conductor and one single core green unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 6.0 sqmm Multi-stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia including all conduit and fixing accessories existing in wall including cutting chases in wall and making good to the disturbed surface to match the existing colour code with 1mm putty taking out the unserviceable sub main wiring complete all as specified and directed
M&L in replacement for Submain wiring with two single core unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 10.0 sqmm nominal cross sectional area Multi-stranded copper conductor and one single core green unsheathed, PVC (FRLSH) insulated, 1100 Volts grade cable with 10.0 sqmm Multi-stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia including all conduit and fixing accessories existing in wall including cutting chases in wall and making good to the disturbed surface to match the existing colour code with 1mm putty taking out the unserviceable sub main wiring complete all as specified and directed.
M & L in repair Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
M & L in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos, 8mm dia 25mm long hex. head screw complete all as specified and directed.
S&F in repair Galvanised iron strip 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground with rectangular blocks below the strip all as directed by Engr-in-Charge
M&L in repair of Earthing complete with galvanized mild steel earth plate electrode 600x600x6 mm thick, burried vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanized steel earth lead wire 4.0 mm dia by means of nut, bolts, check nut & washer of galvanized iron or of steel, earth lead protected by 15 mm dia GI pipe light grade watering pipe 20 mm dia GI light grade GI wire meshed funnel alternate layer of char coal and salt PCC chamber, reassed for and including RCC cover including all necessary excavation & earth work, earth 7.5 mtr wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 1991 print and complete all as specified and directed.
M&L in repair of Chemical earthing for machinery/eqpts with copper earth plate 90cmx60cmx5mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to by using copper earth strip as earth lead of size 50 x 3 mm connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
S&F Modular AC BOX Power unit with Socket Plug top and MCBs with Single pole and neutral enclosure with a two pin and one pin for earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed by Engr-in-charge.
Supply and laying light grade GI pipe of dia 50 mm laid in trenches, wall, and floors complete all as specified and directed.
S&F in replacement 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular strande 6 sqmm aluminiuam conductor complete all as specified and as directed.
S&F in replacement 1100V grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection ,one twin core cable flat or circular strande 10 sqmm aluminiuam conductor complete all as specified and as directed.
Joy Dey Enterprises (BID ID -3230780)
VIDYA TRADERS (BID ID -3228080)
M/s PS Associates (BID ID -3236793)
Unnati Engineers (BID ID -3237745)
FUTURE Inc. (BID ID -3238440)
M I & CO. (BID ID -3232356)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .