| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹34.7 L+₹2.4 L (7.50%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹35.6 L+₹3.3 L (10.3%)Rejected-Finance 26 740 35 KESARI HOUSE NEAR RICO INDUSTRIAL AREA DEVIPURA SIKAR RAJASTHAN 332 001 | SIKAR | SIKAR | RAJASTHAN | 332001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹36.9 L+₹4.6 L (14.3%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹37.0 L+₹4.7 L (14.6%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹39.8 L
EMD Value
₹79,600
Closing Date
10 Dec 2024, 6:00 pmClosed
Commander Works Engineer Hisar
Headquarters Commander Works Engineer Military Engineer Services Hisar, Military Station Hisar Hisar (Haryana)-125006
SPECIAL REPAIR AND REPLACEMENT OF 11 KV OVERHEAD HT LINE INTO HT UG CABLE AT EBS HISAR MIL STN UNDER GE (WEST) HISAR
2024_MES_683608_1
CWE/HSR/38 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Hisar
As per Notice Inviting Tender (NIT)
7 documents required · 7 mandatory
₹500
Yes
GE (West) Hisar
₹79,600
Yes
10 Jan 2025
12 Nov 2024
12 Dec 2024
12 Nov 2024
10 Dec 2024
26 Nov 2024
12 Nov 2024 - 3 Dec 2024
Amount
Dismantling ACSR or AAC conductors removing to store or taken on schedule of credit complete all as specified and as directed.
Dismantling earth wire or copper conductor, service feeder or distributor span removing to store or taken on schedule of credit complete all as specified and as directed.
Dismantling insulators any type, any size complete all as specified and as directed.
Dismantling concrete poles/ struts, any size, transporting to store and stacking or for schedule of credit
Dismantling cross-arms of mild steel channel or angle sections etc. complete and setting aside for re-use or removing to store or for schedule of credit
Supply, laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 6.35 kV/ 11 kV, three phase, earthed system, 3 core, screened, armoured power cable, 95 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 and to be laid in trenches, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe etc. making all connections with necessary glands, lugs, bushing complete all as specified and as directed.
S & F XLPE cable end termination, heat shrinkable, outdoor type complete with jointing material and accessories suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core, 50 sqmm to 95 sqmm complete all as specified and as directed.
Supplying & laying in trenches, in road cutting and along pole 80 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI pipe of 65 mm to 100 mm nominal bore complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
Supply & laying unreinforced precast concrete cable cover class HVP type 1, with peak shape, dimension 300 mm X 180 mm X 40 mm and 65 mm peak thickness as per IS 5820: 1970 complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Raman Electric Trading Co (BID ID -3175160)
HUMERS INFRATECH (BID ID -3179313)
m/s Rajesh Kumar (BID ID -3179387)
SAINI ELECTRIC STORE (BID ID -3179821)
fauji electric works (BID ID -3179747)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .