| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC GR 8 ADDA BUILDING 1ST FLOOR CITY CENTRE DURGAPUR 16 | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | L1 | Accepted-AOC Final work order | |
| 2 | L2₹20.0 L+₹66,821.84 (3.46%)Rejected-Finance DVC PARA MEMARI PURBA BARDHAMAN | MEMARI | PURBA BARDHAMAN | WEST BENGAL | L2 | Rejected-Finance STOOD L2 | |
| 3 | L3₹21.0 L+₹1.6 L (8.44%)Rejected-Finance MAIRAKATA P O GARBETA DIST PASCHIM MEDINIPUR 721127 | GARBETA | PASCHIM MEDINIPUR | WEST BENGAL | 721127 | L3 | Rejected-Finance STOOD L3 | |
| 4 | Rejected-Technical 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | - | Rejected-Technical shortfall documents not submited. |
| Sl No | Description | Qty | Unit | KOUSHIK MONDAL L2 | DURGAPUR POWER L1 | R.K.ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC approved as per choice of E.I.C ) with two inbuilt optical smoke sensors with backward & forward scattering light angles as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost).(Approved Make: Esser/Cerberus Pro/Securiton/ Notifer / Edward / Bosch as per choice of E.I.C ) | 140 | Each | 3,000 ₹4,20,000 | 1,550 ₹2,17,000 Lowest | 3,150 ₹4,41,000 |
| 2.00 | Supplying, installation, testing and commissioning of Addressable Heat Detector (Fixed temperature cum rate of rise) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost)...(Approved Make: Esser/Cerberus Pro/Securiton/ Notifer / Edward / Bosch as per choice of E.I.C ) | 4 | Each | 2,285 ₹9,140 Lowest | 2,318 ₹9,272 | 2,589 ₹10,356 |
| 3.00 | Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC approved ) with two inbuilt optical smoke sensors with backward & forward scattering light angles as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost).(Approved Make: Esser/Cerberus Pro/Securiton/ Notifer / Edward / Bosch) | 80 | each | 3,450 ₹2,76,000 | 1,950 ₹1,56,000 Lowest | 3,750 ₹3,00,000 |
| 4.00 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL / FM / ULC approved )soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Esser/Cerberus Pro/Securiton/ Notifer / Edward / Bosch ). | 4 | Each | 5,500 ₹22,000 | 4,850 ₹19,400 Lowest | 6,100 ₹24,400 |
| 5.00 | Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC approved) approved. (Approved Make: Esser/Cerberus Pro/Securiton/ Notifer / Edward / Bosch ). | 4 | Each | 9,500 ₹38,000 | 8,920 ₹35,680 Lowest | 11,100 ₹44,400 |
| 6.00 | Supply, Installation, Testing & Commissioning of Response Indicator for Alarm Indication of above False Celling Detector. (Approved Make: Reputed) | 70 | Each | 250 ₹17,500 | 220 ₹15,400 Lowest | 270 ₹18,900 |
| 7.00 | Supply, Installation, Testing & Commissioning of Power supply 230 V AC to 12 V DC with all other accessories. (Make: Reputed) | 1 | Each | 26,000 ₹26,000 Lowest | 35,800 ₹35,800 | 29,500 ₹29,500 |
| 8.00 | Supply, Installation,Testing & Commisioning of Microprocessor based Intelligent, addressable fire alarm control panel having expandable features ( VDS / UL / FM / ULC approved as per choice of E.I.C ) fully networkable with each loop capable of taking minimum 120 devices, 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type.The panel shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards.The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emargency condition, with integral battery charger complete as required. The panel shall have extra loop card to serve as stand by in case of burntout or malfunctioning of any operating loop cards. The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 bus.The FACP shall have provision for interfacing with the public address system and BMS( RS 485 )The system must be preloaded with licenced software.( Approved Make: Esser/Cerberus Pro/Securiton/ Notifer / Edward / Bosch as per choice of E.I.C ). 2 Loop | 1 | SET | 3,00,000 ₹3,00,000 | 4,89,900 ₹4,89,900 | 2,86,500 ₹2,86,500 Lowest |
| 9.00 | Supply & Laying of 2 length x 1.5 sq.mm copper Flexible Wire (FRLS)(Finolex/RR/Polycab) | 1,450 | Rm | 121 ₹1,75,450 | 58 ₹84,100 Lowest | 141 ₹2,04,450 |
| 10.00 | Supply & Laying of 20 mm dia PVC Conduit with accessories(make-Precision/Polycab) | 1,450 | Rm | 72 ₹1,04,400 | 40 ₹58,000 Lowest | 75 ₹1,08,750 |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
20 Jan 2025, 6:00 pmClosed
EE.AED.PWD
Office of the Executive Engineer (P.W.D.) Asansol Electrical Division Near Polo Ground Dist Paschim Bardhaman PIN 713304
Construction of Proposed (G plush 3) integrated building of consumer Affairs department, Govt of West Bengal at Asansol in the district of paschim Bardhaman under Asansol Division, P.W.D..SITC of Fire Detection System.
2024_WBPWD_793229_1
WBPWD/EE/AED /eNIQ-90/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
ASANSOL
Please refer Tender documents.
4 documents required · 4 mandatory
₹44,000
Office of the Executive Engineer P.W.D. Alsanso
21 Aug 2026
31 Dec 2024
22 Jan 2025
31 Dec 2024
20 Jan 2025
7 Jan 2025
6 Jan 2025
Amount
Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC approved as per choice of E.I.C ) with two inbuilt optical smoke sensors with backward & forward scattering light angles as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost).(Approved Make: Esser/Cerberus Pro/Securiton/ Notifer / Edward / Bosch as per choice of E.I.C )
Supplying, installation, testing and commissioning of Addressable Heat Detector (Fixed temperature cum rate of rise) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost)...(Approved Make: Esser/Cerberus Pro/Securiton/ Notifer / Edward / Bosch as per choice of E.I.C )
Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC approved ) with two inbuilt optical smoke sensors with backward & forward scattering light angles as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost).(Approved Make: Esser/Cerberus Pro/Securiton/ Notifer / Edward / Bosch)
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL / FM / ULC approved )soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Esser/Cerberus Pro/Securiton/ Notifer / Edward / Bosch ).
Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC approved) approved. (Approved Make: Esser/Cerberus Pro/Securiton/ Notifer / Edward / Bosch ).
Supply, Installation, Testing & Commissioning of Response Indicator for Alarm Indication of above False Celling Detector. (Approved Make: Reputed)
Supply, Installation, Testing & Commissioning of Power supply 230 V AC to 12 V DC with all other accessories. (Make: Reputed)
Supply, Installation,Testing & Commisioning of Microprocessor based Intelligent, addressable fire alarm control panel having expandable features ( VDS / UL / FM / ULC approved as per choice of E.I.C ) fully networkable with each loop capable of taking minimum 120 devices, 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type.The panel shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards.The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emargency condition, with integral battery charger complete as required. The panel shall have extra loop card to serve as stand by in case of burntout or malfunctioning of any operating loop cards. The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 bus.The FACP shall have provision for interfacing with the public address system and BMS( RS 485 )The system must be preloaded with licenced software.( Approved Make: Esser/Cerberus Pro/Securiton/ Notifer / Edward / Bosch as per choice of E.I.C ). 2 Loop
Supply & Laying of 2 length x 1.5 sq.mm copper Flexible Wire (FRLS)(Finolex/RR/Polycab)
Supply & Laying of 20 mm dia PVC Conduit with accessories(make-Precision/Polycab)
Supply & Laying of 6 watt Ceiling /Wall mounting Speaker at all floors at Corridor.
Supply & Laying of 100 / 120 Watt Digital Amplifire at ground Floor
Supply & Laying of Controller with Paging system with microphone at ground Floor
Supply & Laying of 2 CORE 1.5 sq.mm copper Flexible Wire (FRLS) Speaker Cable
Supply & Laying of 20 mm dia PVC Conduit with accessories.
Add GST @18% On total from item no 1 to 15.
Add LWC @1% On total from item no 1 to 16.
KOUSHIK MONDAL (BID ID -5998831)
R.K.ENTERPRISE (BID ID -6001049)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .