Chief Engineer, PWD(Roads), Assam
O/o the Chief Engineer, PWD(Roads), Assam
Improvement and Beautification of the premises of Assam Police Headquarters at Ulubari including Residential Complex, Officers Mess under SOPD (G) for the year 2020-21
2020_PWD_19502_1
No. CE/CW/21/20-21DGPOfficeCampus
Open Tender
Civil Works – Roads
365 days
Guwahati
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,000
Yes
Empowered Officer, ASRB
₹13.0 L
Yes
31 Dec 2020
1 Dec 2020
16 Dec 2020
1 Dec 2020
16 Dec 2020
1 Dec 2020
1 Dec 2020 - 16 Dec 2020
Amount
Scarifying existing bituminous surface to a depth of 50 mm by mechanical means (Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material with in all lifts and lead upto 1000 metres.)
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres)
Cleaning and de-silting of road side drains / cross drains etc. by mechanical means with adequate road safety measures by providing caution boards / safety ribbons /proper barricading where necessary / proper lighting if necessary etc. without damaging the foot paths / slabs / road surfaces etc including immediate disposal of the semi liquid / silt / garbage/Floating materials/ Polythin etc. taken out from the drains/ culverts etc. upto a lead of 20.00 KM from the site within 24 hours as directed keeping the road surface / footpath etc. clean and as directed by the department . De-siltation work will have to be carried out as and when necessary as directed by the Engineer-in-Charge. (Measurement shall be taken on inside of the drain wall )
Dismantling of Cement Concrete Pavement (Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000metres ,stacking serviceable materials and unserviceable materials separately.)
Excavation in Soil by Manual Means. (a)(Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 metres.)
Removal of Unserviceable Soil with Disposal upto 1000 metres (Removal of unserviceable soil including excavation, loading and disposal upto 1000 metres lead but excluding replacement by suitable soil which shall be paid separately as per clause 305.)
Construction of Subgrade and Earthen Shoulders (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table (300-2) (a), ( Including cost of testing of materials at site and laboratory as directed by the deptt.) (a) From Private land
Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC,and compacting with vibratory roller to achieve the desired density,complete as per cl. 401 Grade II Material
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km. ) grade III material
Providing and laying Interlocking Concrete Block Pavement (ICBP) conforming to IS:15658-2006 including all lead and lift complete as per technical specification and as directed.a) 80mm thick interlocking precast blocks having compressive strength of 40N/sq.mm.
Providing and laying M-40 grade cement concrete Edge block/ Edge restraints complete as per Technical specification clause 1504
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications b) TMT-IS 1786 ( Fe-500 D) Secondary Producer (ISI approved)
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork RCC Grade M30With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999 . Height upto 5m,Using concrete Mixer
Providing fitting and fixing in position Ornamental Iron Grill of size 1500x750 mm at Foot Path Edge as directed by engineer incharge.
Providing and fixing in position moulded cement concrete ck(Kerb),manufactured by GEMS of base width 30 cm and height 45 cm in proper level and grade at footpath edge, divider block etc. as directed by the department.
Providing and fixing Anti Skid paver tiles with skater tiles for specially abled peoples per BIS specification with size 340mm x 340 mm x 25 mm as directed and approved by the depatment.
Applying one self-priming coat of Unicem "Shakti" brand of required shade over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.Footpath edge kerb
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Back filling .Back filling behind abutment , wing wall and return wall complete as per Drawing and technical specification.B. Sandy material
9) Providing temporary bamboo barricades for Protection purpose with bamboo post of height 2.00m above the footpath at an interval of 1.5mm C/C fixing of bottom support having 2.00m length at an interval of 1.5m C/C tied with jati bamboo horizontally in 3 rows at an interval of 0.90m C/C with carriage of materials from the work site as and directed by the deptt.(after completion of work the contractor is allowed to collect and clearing the unserviceable bamboo from the site.)
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) 90cm equilateral traingle
60cm circular
80cmm x 60 cm rectangular
Direction and place identification sign upto 0.9sqm size board. Providing and erecting direction and place identification retro-Reflectrorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide clause 801.3 fixed over aluminium sheeting, 2mm thick with area not exceeding 0.9sqm fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)
Providing ‘Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mm x 125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/ 3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician).a) Bi- directional Stud-
Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
Tree reflector made of heigh intensity grade retro-reflectorised sheeting fixed over aluminium sheeting of mm/0.28mm thick firmly fixed with necessary galvanized nail.a)100mm dia/100mmx100mm.
Brick masonry work in 1:3 in sub-structure complete excluding pointing and plastering, as per drawing and technical specifications . In Substructure
Brick masonry work in 1:3 in super structure complete excluding pointing and plastering, as per drawing and technical specifications. In Super Structure
Plastering with cement mortar (1:3 ) on brick work in sub-structure as per Technical specifications
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b) Other ISI approved TMT reinforcement bar AI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc.
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Manual Means (I) Without dewatering up to 3.00 m depth.
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (N) Without plasticiser (A) PCC Grade M15
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.(a).Brick on flat soling.
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. Height upto 5m Using concrete Mixer
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.Without Plasticiser,RCC Grade M20,Using Concrete Mixer
Painting on Steel Surfaces (Providing and applying two coats of ready mix paint of approved brand on steel surface after through cleaning of surface to give an even shade)
Anti Skid Paver Tiles in parking place
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) b) brick/ tilework in cement mortar
Excavation for structures.Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, constructing of shoring and bracing, removal of slumps and other deleterious matter, dressing of sides and bottom, backfilling with approved material. I ) In ordinary soil A)Mechanical Means. (i)Depth up to 3.00 m (with dewatering)
Dry rubble flooring.Construction of dry rubble flooring at cross drainage work for relatively less important works.
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. b) Using other ISI marked approved circular hollow section
40 mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area , wearing layer is to be laid in panels including curing etc. complete as directed.
Providing Ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/ Rouf/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the Department).Delux rangeOf size 400mmx400mm and above
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.a) In cement mortar 1:3
Supplying, fitting and fixing ceiling tiles of 10mm thick made from Duratuff medium density fibre board in size 1200mm x 1200mm x 10mm with Sal wood timber frame (to be measured and paid separately)leaving an expansion gap of 3mm with necessary nails, screws etc. including 1st class local wood (Hollock /Bonsum / Sundi etc.)beading of size 50mm x 12mm complete as directed and specified.
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.