Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹41.4 L+₹3.9 L (10.4%)Rejected-Finance | L2 | Rejected-Finance Since Not Being Lowest | |
| 3 | L3₹46.0 L+₹8.6 L (22.9%)Rejected-Finance 2 MANORATH MAIMOLEM VASCO DA GAMA GOA 403802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | L3 | Rejected-Finance Since Not Being Lowest | |
| 4 | L4₹46.2 L+₹8.7 L (23.2%)Rejected-Finance | L4 | Rejected-Finance Since Not Being Lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Recommended for Financial bid opening, since not enlisted in appropriate category. Also Appendix B of enlistment letters copy not uploaded |
Tender Value
₹44.2 L
EMD Value
₹88,500
Closing Date
4 Sept 2024, 6:00 pmClosed
SHRI JITENDRA KUMAR MEENA IDSE EE
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802
8616/E8
2024_MES_662605_1
8616/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
VASCO
Class D Category c i
8 documents required · 8 mandatory
₹500
GE (NW) VASCO
₹88,500
Yes
10 Mar 2025
29 Jun 2024
6 Sept 2024
29 Jun 2024
4 Sept 2024
16 Jul 2024
29 Jun 2024 - 15 Jul 2024
Amount
SPLIT TYPE AC Taking down carefully the unserviceble rotary / hermetically sealed compressor unit from split type AC 1.5 ton capacity and supply and install new rotary/ hermetically sealed factory made compressor of suitable capacity from the authorised dealer, and testing commissioning complete all as specified and as directed.
All as per Srl item No. 01 above but for 2 Ton capacity as directed.
Charging of refrigerant gas with required quantity, after testing the system against leakage & putting the split type AC of 1.5 / 2.0 Ton capacity in perfect working condition complete all as specified and as directed.
Supply only running capacitor 45 MFD for split type AC of suitable capacity complete all as specified and as directed.
Supply only outdoor unit of split AC of 1.5 Ton capacity, 230 volt comprising of condensor coil, fan motor with blade, of make and type same as per existing complete all as specified and as directed.
Supply only indoor unit of split AC, 230 volt comprising of cooling coil, blower, remote sensor unit with remote of 1.5 ton capacity of make and type as per the existing complete all as specified and as directed.
Replacement of Air filter made of PVC / Nylon fiber suitable for any split type AC complete all as specified and as directed.
Replacement of complete wiring kit of suitable make and model of split type AC of any capacity complete all as specified and as directed.
Replacement of condenser fan blade made out of aluminium/plastic for split type AC of suitable capacity of make as approved complete all as specified and as directed.
Replacement of blower made of aluminium / plastic for split type AC of suitable capacity of make as approved complete all as specified and as directed.
Replacement of starting capacitor 120/150 MFD complete all as specified and as directed.
Replacement of starting relay suitable for split type AC complete all as specified and as directed.
Supply only copper tubing (two copper tubings with insulation tube) as per existing size for split AC any capacity 230 volt complete all as specified and as directed.
Supply only Printed circuit board (PCB) of Window / Split ACs 1.5/2.0 ton complete all as specified and as directed.
Servicing of split type AC of any capacity and make, washing condensor, cooling unit, cleaning of air filter incl testing and replacement of spares / components as required complete all as specified and as directed. (i) Spares will be measured & paid as supply only items mentined here in above. (ii) Gas charging etc will be measured & paid separately.
Taking down of old unservicable air conditioner and supply and install new portable air conditioner with Non-Inverter Compressor, Smart & Elegant Design, single phase 230 V 50 Hz 100% Inner Grooved Copper Tubes, Capacity: 1.0 ton suitable for small / medium size rooms (Up to 100 square feet) refrigerant: R-410 Refrigerant has been used in this AC which is environment friendly 360° rotating strong caster wheels to bear load of the AC and makes it easy to move with elegant design with Top Throw, Auto Swing & Auto Restart, easy Installation, Self Diagnosis Function with Remote Control, LED Display, free standing with cooling power 3.45 KW wattage with exhaust pipe and window assembly panel of Make:- Havells/ Lloyd 2020 Model, LP12B01TP, White or equvialent in Voltas, Bluestar, Carrier, O General etc complete all as specified and as directed.
WATER COOLERS Disconnection old unserviceable water cooler and supply & install new Aqua Clear Stainless Steel Water Cooler of capacity 60/80 ltrs with in built RO of storing capacity, of 60 Ltrs single phase 230 V, 50 Hz power consumption of 800 Watt to 1000 watt RO unit should have the Treated Water Flow of 1 m3/hr and Recovery : 55- 60%, Feed Water TDS should be 900 PPM (Max). Note:- Old unserviceable water cooler of any capacity will be shifted to AGE E/M-II yard.
Taking down carefully the old unservicable compressor unit from the water cooler and supply and fix new hermetically sealed compressor of suitable size & capacity from the authorised dealer and testing the compressor after fixing etc for the following model :-
Kirloskar -4440
Tecumseh -AW 1000
Charging of refrigerant gas with required quantity, after flushing out and testing the system against leakage etc and of connected works including replacement of copper capillary tube and putting the water cooler in perfect working condition and testing the same after re-installation complete all as specified and as directed of Capacities 40/80/100/120/150 ltr Capacity
Cleaning, checking, servicing of water cooler of any capacity and re-assembling connecting complete all as specified and as directed. (i) Leakage testing of Gas and Gas charging will be measured and paid separately. (ii) Spares will be measured and paid separately as supplied only items.
Supply only starting relay complete with over load protector suitable for Kirloskar/ Tecumsah compressor complete all as specified and as directed.
Supply only starting capacitor 40-60 MFD
Supply only starting capacitor 80 - 100 MFD
Supply only running capacitor 25 MFD
Supply only running capacitor 10 MFD
Supply only condenser fan motor single phase, with blade, capacity 1/35 HP including mounting clamps, bushes, nuts and bolts complete all as specified and as directed.
Supply only Srl item No. 26 above but capacity 1/10HP
Supply only thermostat suitable for any type of water cooler
Cleaning of water cooler tanks with potassium permanganet solution after removing all dust/mud particles complete all as specified and as directed.
Repairing of water cooler storage tanks leakages by soldering / brazing work complete all as specified and as directed.
Supply only liquid line filter of make and size as approved by GE complete all as specified and as directed.
Supply only PVC float valve 15mm bore with PVC heavy duty ball and rod, complete all as specified and as directed.
Supply only brass chromium plated push cock of 15mm bore (as per sample) with brass flex nipple complete all as specified and as directed.
Supply only PVC drain pipe 32mm dia, 1300 mm long flexible pipe complete all as specified and as directed.
M&L spray painting of water cooler of any capacity after scrapping old painted surface and applying one coat of synthetic enamel paint including writing serial No/MES No & SM No (Size of letter 20mm) on the front of the Machine, with white paint complete all as specified and as directed.
REFRIGERATORS Taking out carefully Old un-serviceable compressor unit from the refrigerator and S&F new factory made rotary/ hermetically sealed compressor unit suitable for 165 ltrs capacity from the authorised dealer and testing the compressor after refixing complete all as specified and as directed
Cleaning, checking, servicing of Refrigerator of any capacity and re-assembling connecting complete all as specified and as directed. (i) Leakage testing of Gas and Gas charging will be measured and paid separately. (ii) Spares will be measured and paid separately as supplied only items.
Charging of refrigerant gas with required quantity after flushing out the system, testing the system against leakage and putting the refrigerator in working condition and testing after repair, of 165 ltrs Refrigerator complete all as specified and as directed
Supply only liquid line filter for refreigerators of any type and cap of approved make complete all as specified and as directed.
Supply only starting relay suitable for any type and cap of Refrigerators complete all as specified and as directed.
Supply only thermostat switch with knob for refrigerator.
Supply only bulb screw type 15 watts suitable for any type of refrigerators
Supply only evaporation fan motor single phase, 230 volts, AC for any make and capacity of refrigerators including fan blades complete all as specified and as directed.
Supply only freezer assembly suitable for any capacity and make of Refrigerators complete all as specified and as directed.
Supply only condenser coil suitable for refrigerators of any capacity complete all as specified and as directed.
Supply only vegetable tray, egg tray, water tray etc complete all as specified and as directed.
VOLTAGE STABLIZER Rewinding of burnt transformer using super enamel copper wire of existing size as directed by EIC, for the following capacity of voltage Stablizers:
5 KVA Cap of any make
4 KVA Cap of any make
Replacement of cut off relay of the following capacity of voltage stablizers Make- Dunmeg or equivalent as approved by GE
5 KVA Cap of voltage stablizer
4 KVA Cap of voltage stablizer
Replacement of automatic circuit complete of the following capacity of the voltage stablizer:
5 KVA Cap
4 KVA Cap
Replacement of high/low cut off with time delay circuit of the following capacity of the voltage stablizer:
5 KVA Cap
4 KVA Cap
Replacement of tigger transformer for the following capacities of the voltage stablizer:
5 KVA Cap
4 KVA Cap
Replacement of volt meter AC, 230 volt of any capacity and size suitable for voltage stablizers complete all as specified and as directed.
Replacement of indicator bulb suitable for voltage stabilizers of approved make all as directed by EIC.
Taking down old unserviceable Split type air conditioners of Capacity 2.0 Tr comprising of indoor & outdoor units complete and suppy & install new Split air conditioner comprising of indoor & outdoor units complete with cordless remote control unit with cooling function of capacity 2.0 TR. Note:- The old split air conditioner comprising of indoor & outdoor units will be deposited to MES store yard of AGE E/M-II.
Taking down of old unserviceable wall mounted stablizers and supply & installation of new Voltage stabliser of 5 KVA capacity automatic voltage stabilizer, wall mounted with input corrected range of 140 Volts to 280 Volts and output range voltage 225 Volts +/- 11% with digital display features of high and low out of range voltage shut down and time relay of 2 to 3 Mins on initial start Capacity – 5 KVA.
M & L for sub main wiring with 6 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor stranded cable with and including continuous earth wire of size 4.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified and as directed. Note :- 2 Runs of 6sqmm copper conductor cable and 1 Run of 4sqmm copper conductor cable with 1 Run PVC conduit 25mm dia will be measured as one RM unit
Supply & fixing Sheet Metal Enclosures with one single pole MCB of 20 Amps capacity 240 volts 'B' series 10KA and making connections complete all as specified and as directed.
S&F (in repairs) MCCB, TPN, 100 Amps, Icu=16 KA, 415 volts, 50 hz, AC, with Adjustable Thermal release, Fixed magnetic type suitable release in duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections complete all as specified and as directed.
S&F in repairs MCCB, TPN, 160 Amps, Icu=35 KA, 415 volts, 50 hz, AC, with Adjustable Thermal release, Fixed magnetic type suitable release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections complete all as specified and directed.
S&F in repairs MCCB, FP, 200 Amps, Icu=35 KA, 415 volts, 50 hz, AC, with Adjustable Thermal release, Fixed magnetic type suitable release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections complete all as specified and as directed.
Servicing and testing of Water Cooled Package Air Conditioners, comprising of Hermetic / Semi Hermetically sealed Scroll Compressors with microprocessor based control, including copper refrigerant piping, electrical interlocking between indoor units and condenser water pump motor, cooling tower motor etc, suitable for operation on R - 407C or any ecofriendly refrigerants , capacity not less then 3 x 15 TR (2 Working +1 No 50% stand by) i.e. one 15.0 TR standby as per air conditioning data sheet enclosed as Appendix 'A' with all equipment and accessories complete and comprising the following :- (a) Three Nos Package type air conditioning unit fully microprocessor controlled each of minimum 15.0 TR capacity complete and comprising of the following :-
(i) Hermetically sealed Scroll type compressor with inbuilt motor of matching capacity, electrically operated on three phase 415 volts, 50 Hz AC supply complete with suction and discharge shut of valves, automatic capacity control with thermostats and solenoid valves, built in suction strainer, oil pump, hot gas muffler, oil pressure safety switch etc all as specified. (ii) Three Nos guage panel complete with HP/LP cut outs. oil switch, suction, discharge and oil pressure guage. (iii) Cooling coils of copper tube with aluminium fins. (iv) Filters, filter plenum and by pass dampers (03 Nos lots) with 90% efficiency to 20 microns. (vi) In built Blowers for weather makers complete (vii) Expansion valves and pilot solenoid valves.
Note:- The servicing to be carried out 02 times in the interval of 5 Months (viii) Three sets of spring antivibration pads and suitable foundation as per manufacturer's instructions for installation of the above package units. (ix) Necessary copper piping for liquid line complete with fittings valves etc. (x) First charge of ecofriendly refrigerant gas like R407C and oil for the complete plant. (xi) One set of flow switch in condenser water line (b) One lot of air distribution system from Package units to the space to be air conditioned and provision of return air plenum as per IS- 665 comprising of class VIII galvanized sheet with suitable supporting arrangements and bracing, supply / return / fresh air grills on wooden frame work duly painted / finished to match with the existing ceiling, fire damper fusible link operated
(b) One lot of air distribution system from Package units to the space to be air conditioned and provision of return air plenum as per IS- 665 comprising of class VIII galvanized sheet with suitable supporting arrangements and bracing, supply / return / fresh air grills on wooden frame work duly painted / finished to match with the existing ceiling, fire damper fusible link operated (c) Design and provision of hollow GI duct suitably insulated and weather protected from outside plant room to inside air conditioned room of suitable size and thickness duly supported on steel structure from AC Plant room to the rooms to be air conditioned for continuous supply and return air ducts with Plenum chamber and Canvas cloth joint.
(d) Necessary provision of FRP cooling tower with fan and fan motor working on 415 V AC 3 phase supply of suitable capacity along with water pumps of suitable capacity electrically operated, 3 phase 415 Volts, monoblock type- 02 Nos (Minimum capacity 5 HP), circulating water pipe line made up of ERW steel pipe heavy grade with all fittings and fixtures of suitable size and length duly painted on the outer surface area to the unit including necessary supports / laying underground as per OEM specifications complete all as specified and as directed. Note :- Rate quoted for Sr Item No. 60.00 is inclusive of provision cost of Sr Item No. 60.03 & 60.04
Taking down of existing armstrong type false ceiling carefully, and re-fixing the same after installation of new ducts including removal of existing old air ducts.
M&L for Earthing complete with GI earth plate electrode 600x600x6 mm thick buried directly in ground earth pit not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below ground level connected to GI earth lead strip 20 x 4 mm size by mean of nut/bolt and washer of GI as shown in electrical plate no 3 of SSR part I including necessary excavation and earth work GI pipe 20mm dia light grade for watering etc, PCC pit chamber with PCC cover in cement concrete 1:3:6 Type C2 with 40 mm thick Precast RCC cover slab 1:2:4 type B 0 with 8 mm dia TMT bar and handle with lifting hooks, adequate quantity of charcoal dust and common salt mixed with ordinary paddy field earth 20% etc including testing complete all as specified and as directed.
Supply, Installation, and commissioning of factory made fabricated CPRI approved Indoor type double door complete finished in all respect cubical type LT switch board suitable for and including under mentioned accessories panel shall be fabricated out of 2.00 mm thick powder coated mild steel sheet and angle iron frame of 40x40x6 mm size and Provn of 4 Nos aluminium bus strip of suitable size fixed on porcelain insulators and wiring of sections with aluminium strip of suitable size including PCC foundations complete in all respect :- (i) MCCB TPN 415 Volt capacity 63 Amps 16 KA microprocessor based (ICS100% = ICU) and trip setting as required - 02 No (incoming) (ii) ON load front operated change over switch 415 volt 4 pole of size 63 Amp -01 No.
Supply and fixing of molded case circuit breaker CG Cat Part No:- NSX250F, COMPACT NSX TYPE 3 PHASE 250 AMP, 690 Volt AIC rating – 36 KA @ 415 V complete all as specified and as directed.
Supply & fixing of Single Phase Preventer VSP-2 / VSP-3/ VSP D-2 type, 415 V, TP complete all as specified and as directed.
Renewal of ball bearing( size No 6203) for electric induction motor of 2 HP to 5HP capacity complete all as specified and as directed.
Renewal of ball bearing for AHU of 3 x 15 TR capacity complete all as specified and as directed.
Renewal of thermostate / temperature control switch suitable for 1x15 TR Air Cooled package type AC plants complete all as specified and as directed.
Renewal of anti freeze switch suitable for Central/ package type AC plants complete all as specified and as directed.
Renewal of drier for liquid line suitable for 3 x 15 TR capacity compressor complete all as specified and as directed.
S&F in repairs including testing harmetically sealed scroll Compressor of capacity 5.5 TR suitable for existing 3 x 15 TR Air Cooled package type AC indoor unit of 3 x 15 TR capacities (Model No. ZR72KCG-TFD-52 E of EMERSON), suitable for 407(c) non CFC refrigerent gas including necessary brazing work to make the system leak proof complete all as specified and as directed.
M&L for Taking down/ dismantling of portion of false ceiling for internal cleaning of air ducts with cloths with care and deposting the dust particles in container, removing the grills/ diffusers, and refixing the grills, diffusers and false ceiling in its original locations including renewal of screws complete all as specified and as directed (3 x 15 TR).
Renewal of drier for liquid line suitable for 3 x 15 TR capacity compressor complete all as specified and as directed.
Renewal of thermostate / temperature control switch suitable for 3 x 15 TR Package type AC plants complete all as specified and as directed.
Supply and charging of Refrigerent gas R-407 (c) Non CFC (ecofriendly) in company sealed cylinders of any capacity complete all as specified and as directed. Note: If the recharged refrigerent gas is leaked within one month of running of AC plant, the contractor shall recharge gas (including supply) without any extra cost to department.
Renewal of V Belts of size B-40 to B-60 complete all as specified and as directed.
S&F in repairs thermostatic expansion valve of 3 x 15 TR working on R-407 (c) NON CFC refrigerent gas (Ecofriendly) Air cooled package type AC plant (Make - Blue Star) including collecting the refrigerent in the empty cylinders arranged by Contractor at his own resources by any means, cutting, welding, brazing, renewal of gasket, nuts, bolts and washers etc complete all as specified and as directed.
Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 16 Sq mm, 4 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified.
Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil getting out and levelling of bottom surface to required level for laying UG cable / erection of poles all as specified.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick all as specified.
Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and as directed.
Supplying & Laying precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm in trenches for protect to under ground cable complete all as specified and as directed.
Supplying & Laying in trenches Clear river Sand for cushioning under ground cable 8 cm below and 15 cm above complete all as specified and as directed. Note: Punned thickness only will be measured and paid.
Repair and replacement of unserviceable flood light LED Light 50W 230 Volts AC outdoor type secondary optics, aluminium pressure die cast housing with IP 66, 4 KV inbuilt surge protection efficasy 120 Im / W 5700 K, Make Bajaj Cat No. BJFL 50 W LED I with driver or equivalent of Philips, CG complete all as specified and as directed.
Dismantling of old burnt LT panel of any capacity and Supply, install and testing commissioning of LT panel KIOSK type cubical weather dust and vermin proof (out door type) CPRI approved factory made suitable for operation on 1100 Volts 3 phase, 4 wire 50 HZ AC electric supply externally powder coated & internally painted with two coats of synthetic enamel paints over one coat of red oxide primer made out of 3 mm thick CRCA steel sheet as size having opening and locking arrangement both from front & back side with cable tray of size not less than 20 cm including copper busbar size 50 x 10 mm fixing on angel iron size of 50 x 50 x 6 mm including connected accessories and necessary PCC work 1:3:6 type C-2 blocks complete with following accessories :-
(a) MCCB 400 Amps, 4 pole 36 KA, adjustable thermal and fixed magnetic setting - 01 No (incoming) (b) MCCB 250 Amps, 4 pole 35 KA fixed thermal and fixed magnetic setting - 02 Nos (Outgoing) (c) MCCB 160 Amps , 4 pole 25 KA fixed magnetic thermal and fixed magnetic setting - 01 No (Outgoing) (d) MCCB 100 Ampsm 4 pole, 25 KA fixed magnetic thermal and fixed and fixed magnetic setting - 01 No (Outgoing) (e) S & Fix multi function digital meter with LCD display incl PT & CT having CTR 50/5 (Parameters :- V, A, F, PF, KW, KWA, KWH, KVAH, KVARH) - 01 Nos (f) Indicators with neon lamp with RYB shade, 240 Volts 50 C/s of suitable capacity resistance -01 set (g) Internal wiring with suitable size PVC insulated single core copper connecting instruments - 01 lot.
Dismantling/ taking down burnt squirrel Cage Induction Motor of any capacity, 3 Phase, 415V, 1450 RPM of any make from its base and transporting the motor to the Contractor's workshop and back, refixing the motor at site after carrying out the following repairs/ renewals complete all as specified and as directed :- (i) opening the side covers and removing the rotor and cutting/ removing the burnt coils / winding from stator. (ii) Cleaning the slots carefully (iii) Rewinding the stator using super enamelled copper winding wire with same size, number of coils, number of turms/ coils as per data acquired from the old burnt motor, including varnishing two coats, drying and reassembling the electric motor at site (iv) Testing the coils for there continuity and no current passing through the stator core.
(v) Dynamic testing of the rotor and alignment of the main shaft and ensure that no imbalance vibtrations. (vi) Re-assembling the rotor and connecting the end terminals to the terminal plate of the motor, closing the ends with side covers (vii) Testing and commissioing the electric motor connecting to the electric supply to its full load by connecting the compressor. (viii) Renewal of Bolts, nuts and washers Note :- Parts renewed i.e Ball bearing shall be measured and paid separately. However filling of grease and oiling extra shall be deemed to be included in Unit rates.
star freeze service (BID ID -3066789)
Heat Control (BID ID -3065911)
Susheel Enterprises (BID ID -3070410)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .