Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 CrAccepted-AOC | ₹5.3 Cr | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹5.5 Cr+₹23.5 L (4.42%)Rejected-Finance B 22 HQ ADG NEI GUWAHATI BABULAR BAZAAR TINSUKIA 786125 ASSAM | TINSUKIA | ASSAM | 786125 | ₹5.5 Cr+₹23.5 L (4.42%) | L2 | Rejected-Finance Not being L1 Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not being eligible Bidder as per NIT Conditons |
Tender Value
₹5.3 Cr
EMD Value
₹5.8 L
Closing Date
5 Oct 2022, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVN OF I LEVEL FACILITIES AT AF STN MOHANBARI
2021_MES_496864_5
88631/MHB/E8
Open Tender
Civil Works
Lump-sum
545 days
Mohanbari
Please refer tender documents
8 documents required · 8 mandatory
₹3,000
GE AF MOHANBARI
₹5.8 L
Yes
15 Nov 2022
6 Sept 2022
7 Oct 2022
6 Sept 2022
5 Oct 2022
21 Sept 2022
Amount
NOTE (Applicable for all Parts/ Items):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
SCHEDULE "A" Part - I (BUILDING / STRUCTURES WORK ) Details of pre priced Schedule is given in tender documents
SCHEDULE 'A' PART- II ( SITE CLEARANCE AND AREA DEVELOPMENTS) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- III (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- V (ROAD / PATH / CULVERT / HARDSTANDING ) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- VI ( SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- IX (EXTERNAL ELECTRICFICATION) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- X ( FIRE DETECTION SYSTEM AND FIRE FIGHTING ) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- XI (LIGHTNING ARRESTER) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- XII (FIRE POINT) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- XIII (AIR CONDITIONING AND POWER CONVERTER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XVI (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
BLANK
SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK Excavation in trenches not. exc 1.5 m wide and not exceeding 1.5 m in depth for foundation etc drain, manhole, laying of cable not exceeding 10 Sqm on plan and not exceeding 1.5mtr in depth and getting out in soft/loose soil complete all as specified and as directed.
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level, not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Removing excavated soil to a distance exceeding 250 m but not exceeding 500 m and depositing where directed at a level, not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Removing excavated soil to a distance exceeding 500 m but not exceeding 1.50 Km and depositing where directed at a level, not exceeding 1.5 metre above the starting point complete all as specified and as directed.
INTERNAL ELECTRIC SUPPLY S&F telephone socket, single module, polycarbonate type, complete with box including connection complete all as specified and as directed.
INTERNAL ELECTRIC SUPPLY S&F LED T-8 Retrofit tube light fitting 4 ft 1x20 watt, 230 volt energy efficient epoxy powder coated CRCA sheet housing with channel, connector block, having short circuit and surge protection etc. including 1x20 W T8 LED Tube light complete with all accessories internally pre-wired and including connection with twin core twisted flexible wire copper conductor cable of suitable size complete all as specified and directed.
S & F New generation energy saving and environmental friendly long life LED security light fittings 45 watt including LED lamp, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and impact resistance of IK 07 fixing with and including bracket of 40mm bore GI pipe, light grade, 1.50m length, bend to shape, along with fixing clamps, nuts, bolts and washers complete all as specified and directed.
S&F LED luminaire 600mm x 600mm, 36 / 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders etc. including LED lamp, suitable for roof ceiling including connecting up with driver three core flexible wire copper conductor cable of suitable size complete all as specified and directed.
S&F Energy efficient five star rated ceiling fan, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan including fan hook, clamp & fan box complete in all respect all as specified and directed.
S&F Exhaust fan, heavy duty, of size 300 mm sweep metal body, double ball bearing complete with and including suitable metallic louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan including making suitable hole and plastering & fixing in position with suitable arrangement in wall complete all as specified and directed.
S&F LED light fittings, mirror type with high out put diffuser, 2 feet long, 10 watt 220 V AC, decorative type with driver, holders etc. including 1x10 W LED lamp including connecting up with three core flexible wire copper conductor cable of suitable size complete all as specified and directed.
S & F factory made sheet metal enclosure double door designed SPN 6 Way DB with 200 Amps rated copper busbar, grouter/ fixed flush in wall with and including suitable flat iron complete with, neutral link, dinrail suitable for mountaning MCB’s complete all as specified and as directed. (Note:- MCBs shall be measured and paid separately)
S & F factory made sheet metal enclosure double door designed SPN 2 Way DB with 200 Amps rated copper busbar, grouter/ fixed flush in wall with and including suitable flat iron complete with, neutral link, dinrail suitable for mountaning MCB’s complete all as specified and as directed. (Note:- MCBs shall be measured and paid separately)
S&F MCB single pole of capacity 6 to 32 amps, C-curve, 10 KA breaking capacity and making connection complete all as specified and directed.
S&F MCB single pole and neutral of capacity 6 to 32 amps, C-curve, 10 KA breaking capacity and making connection complete all as specified and directed.
Supply, fixing, connecting, testing and commissioning MCCB, TP with microprocessor release 100 Amps, 16kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (medium grage), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast RCC (1:2:4) type B1, cover slab of size 54 cm x 54 cm x 5 cm and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (light grade) testing on completion complete all as specified and directed. [Note : (a) Proper earthing pit should be provided with pit cover. (b) Excavation/earthwork is deemed to be included in the quoted rate.]
INTERNAL WATER SUPPLY. S&F 15 mm bore brass angle stop cock CP high pressure with capstan head, long shank screwed down complete all as specified and directed.
SEWAGE DISPOSAL M & L for on site LLDPE septic tank of capacity 5500 ltr to 6000 ltr, with necessary strong basement with concrete as per manufacturer's instruction complete all as specified and directed. (Note: Cost of basement shall deemed to be included in the unit rate.)
Construction of Soakage Well of size 1.2 m dia x 3 mtr effective depth, complete all as specified and as shown on drawings.
EXTERNAL WATER SUPPLY Road cutting of size 30 cm width x 45 cm depth for laying of GI pipes including making good the road surfaces with necessary returning filling and 15 cm thick PCC (1:2:4) type B1 ( using 20mm graded stone aggregate) on top, complete all as specified and directed.
M&L for construction of brick masonry valve pit chamber of internal dimension 900 x 900 x 900 mm depth with sub class 'B', old size, in CM (1:4) and 10mm thick plastering in CM (1:4) ,PCC (1:4:8) type D2 (using 40mm graded broken stone aggregate ) as in foundation lean concrete ,PCC (1:3:6) type C1 (using 20mm graded broken stone aggregate) as in bedding and copping MS frame with 50x50x6mm angle iron 5mm thick MS sheet cover plate with locking system ,hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preperation of surface ,three coats of white wash on plastered suface (exposed to view ) including necessary excavation in soft loose ,soil ,returning filling in and removal of surplus soil to a distance not excedding 50 m complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply, fixing, connecting, testing and commissioning MCCB, 4 pole, 200 Amps, 35kA breaking capacity with fixed thermal and fixed magnetic setting, 415 Volts AC, 50Hz, fixed in and including suitable size sheet metal enclosure, wall mounted type (for outgoing connection for existing panel) complete all as specified and directed.
Road cutting of size 30 cm width x 45 cm depth for laying of GI pipes as cable protection, including making good the road surfaces with necessary returning filling and 15 cm thick PCC (1:2:4) type B1 ( using 20mm graded stone aggregate) on top, including GI pipe 80mm bore, medium grade, complete all as specified and directed.
M&L for Earthing complete with copper earth plate electrode 600x600x3.15 mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to copper strip of size 20x3 mm earth lead by means of bolt, nuts , check nuts and washers of copper upto 7.5m length, earth strip protected by and including 40mm dia GI pipe (light grade ) and connected to main test point or body of pole or lightening arrestor or main controlling switch as directed including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) Type B1 cover slab of size 54x54x5cm reinforced with 8 mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting made out of 10mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI Pipe (medium Grade ) for watering, charcoal and salt in alternate layers of 15 cm (Compacted thickness ) in any type of soil and disposal of spoil to a distance n.exc 50m and necessary testing complete all as shown in Electrical Plate No3 of SSR part -1 all as specified and directed.
M&L for Earthing complete with GI earth plate elecrode of size 600 mm × 600 mm × 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to GI earth strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work pre-cast RCC(1:2:4) type B-1 pit cover 50mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast RCC (1:2:4) type B1, cover slab of size 54 cm x 54 cm x 5 cm and PCC (1:2:4) type B-1 concrete pit and angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15 cm compacted thickness all around the earth electrode with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect, protected by 40 mm bore (light grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion complete all as specified and as directed. [Note : (a) Proper earthing pit should be provided with pit cover. (b) Excavation/earthwork is deemed to be included in the quoted rate.]
Supply, installation, commissioning and testing of LT panel board of suitable size to accomdate mentioned accessories, factory made outdoor cubical type double door shutter, pedestal mounted with hinged doors & locking arrangement made out of 3.15 mm thick mild steel CRCA sheet supported and fixed on structural frame of angle iron of size 50 x50 x6mm, confirming to IS 8623, painting to all internal & external exposed steel surfaces with powder coating paint (7 stage process), duly fixed in ground with PCC foundation (1:2:4) type B1 (leg of LT panel be embedded not less than 15cm in PCC) with danger notice plate of 1.6mm thick mild steel sheet, vitrious enamelled (white) with letters figures and conventional skull and bones in signal red colour suitable for 3 phase 4 wire system 415 Volts grade with necessary wiring with PVC sheathed stranded copper conductor of appropriate length size with and including fixing lugs bolts, screws etc complete all as specified and directed. For safety , panel shall be finger touch proof and it should have IP-66 Protection in module door open condition. Busbars shall be made of high conductivity, and high strength Aluminum E91 grade as per IS 5082-1981, of rectangular cross sections better suitable for full load current for phase bus bars and full rated current for neutral bus bar. The busbars shall be supported on non-breakable, non-hygroscopic epoxy resin or glass fiber reinforced polymer insulated supports.The material and the spacing of the Busbar supports should be same as per the type tested assembly (TTA). All bus bars shall be provided in a separate chamber and all connections shall be done by bolting. Panel comprising of the following accessories :- [Note: (i) The bottom portion of enclosure shall be minimum 60cm above ground level of legs of angle iron. (ii) PCC foundation shall deemed to be included in the unit rate.]
FIRE DETECTION SYSTEM AND FIRE FIGHTING S & F Fire alarm beep buzeer bell complete all as specified and directed.
S & F CO2 Fire Extinguisher, 4.5 Kg capacity complete all as specified and directed.
S & F portable ABC multipurpose mono monioum phosphate powder, nitrogen pressurised type Fire Extinguisher, capacity 6 Kg complete in all respect (6 x 85 = 510) and as directed.
AIR CONDITIONING AND POWER CONVERTER SUPPLY Supply, installation and testing of hi wall split units 2 TR indoor/outdoor complere with cordless remote control unit and in-build air ioniser and plasma filter for better indoor air quality with 5 star rating inverter AC and BEE 3.2 complete all specified and directed.
Supply, installation and testing of hi wall split units 1.5 TR indoor/outdoor complere with cordless remote control unit and in-build air ioniser and plasma filter for better indoor air quality with 5 star rating inverter AC and BEE 3.2 complete all specified and directed.
Supply, installation, commissioning and testing of Voltage stabilizer for primary switching technology,high power efficiency , built in thermal overload protection ,low & high voltage cut-0ff protection ,single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.
Supply, installation, commissioning and testing of Voltage stabilizer for primary switching technology,high power efficiency , built in thermal overload protection ,low & high voltage cut-0ff protection ,single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed.
Supply, installation, commissioning and testing of Auto Wound Voltage Converter 220 V to 110 V Step Down ToroidialTransformer MCB-40 AMPS, Single Phase 50/60Hz 100% Copper Wound for better Performance, Table & Wall Mount, No Humming Noise, With Enclosure.2 Universal Socket (Output - 110v) Capacity Of 3 KVA complete all as specified and as directed.
CHEMICAL SAFETY AND DG SET (SCHEDULE 'A' PART- XIV) Supply and fix electric water heater, storage type, acrylic/ABS body with stainless steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with and including all accessories such as safety valve, thermostate, NRV, connection pipe, etc. complete all as specified and directed.
Supply, installation and testing Body & Eyewash, Flow rate Eye Wash: 11.4 liters per minute (3.0 gallons per minute) for 15 minutes, Flow rate Shower Head: 75.7 liters per minute (20.0 gallons per minute) for 15 minutes, Diameter of Shower head: 10-Inch, Diameter of Eye Wash bowl: 10-Inch, Eye Wash Bowl Material: ABS, Shower Head Material: ABS, Supply Pipe Material: Carbon Steel, Foot operated: No, Inlet connection: 1 1/4 Inch IPS, Outlet connections: 1 1/4 Inch IPS complete all as specified and directed. (Make: EURONICS model No. Carbon Steel ESY02Y or equivalent model of make: National Safety Solution / Unique Safety Services / Unicare.)
Supply and installation Spirit Level 12-Inch Accuracy Solid spirit bulb which doesn't break easily, Aluminum frame is strong and precision extruded which increases accuracy and strength of the Spirit levels Rubber moulding is provided on the sides to prevent damage to the body of the spirit levels complete all as specified and directed. (Make: Taparia / Stanlay / Hira / Freemans.)
Supply and installation Accurate Measurement on Temperature and Humidity: Recording the current indoor temperature and humidity, the temperature range is from 32°F - 122°F (0℃-50℃) and humidity range is from 20%-95% complete all as specified and directed. (Make: Precise / Uni-T / HTC / Fluke.)
Supply, installation, commissioning and testing of of silent Diesel Engine driven generator set 415 Volts, 3 phase 4 wire 0.8 PF, engine as per IS : 10001/10002 and alternator as per IS : 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundatin etc, of capacity 100 KVA Comprising and including of following. (A) DIESEL ENGINE: Liquid cooled turbo charged with after cooler to deliver suitable BHP for 100 KVA at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete with following- (a) Radiator with blower fan or heat exchangar with guard. (b) Pipe coupling for engine cooling system piping. (c) Paper element filters (d) Fuel filter,fuel pipe & fuel injection pump. (e) Lube oil filter,bypass filter,corrosion inhibitor coolant with first filling of lube oil and disel during commissioning and minimum 12 hours testing complete. (f) Fly wheel housing with engine bearing mechanism and fly wheel to suit alternator. (g) Dry type replaceable air cleaners,vacuum indicators & residential silencers.
Serial Item No. 14.43 (Contd....) (h) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (k) Battery charging alternator & self starter. (m) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (n) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet 30 gauge for the entire length of exhaust pipe. (p) Interconnecting copper cabling of adequate capacity batteries control. (q) Electric operated electronic governor. (B) ALTERNATOR- Brushless AC alternator, self exited ,self regulated 3 Phase, 415 Volt, 4 wire, rated for output of 100 KVA ,minimum power factory 0.8, 1500 RPM , insulation class 'H' salient pole, revolving field,single bearing automatic voltage regulator and directly coupled with engine. (C ) ENGINE INSTRUMENT PANEL- (i) Digital type controller able to display- alternator voltage, battery voltage, load current, fuel level, lub oil pressure, frequency, RPM and able to stop generator on any fault and to display parameters i.e. low battery,LLOP, under voltage, over voltage, High engine temperature, battery charging failure and other protection as per manufacturer recommendations including necessary wiring set of relays, MCB/Fuse etc complete. (ii) Engine start and stop switch (iii) Emergency Stop Switch (iv) DC power supply suitable for controller and suitable battery charger connected to load side to charger battery.
Serial Item No. 14.43 (Contd....) (F) DIESEL STORAGE TANK: Fuel tank of MS sheet of capacity not less than 12 Hrs continuous operation on full load with fuel level guage, drain plug, locking arrengements, etc including connection to Engine through fuel filter/ manual feed pump as per manufacturer recommendation. (G) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and power coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 db(A) at a distance of 1 M at 75 % load under field condition and 70 db at 3 M from Gen set when DG set is working at full load along with testing conformance, laveling certification etc as laid down in GSR No.371(E) dt 17 May 2002. (H) MISC: Tool kit operation, maint cat, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturers standard practice.
ARBORICULTURE (SCHEDULE 'A' PART- XV ) Supply and planting of Ashok Tree with Height 3 to 4 feet including Digging Holes 1.2 m Dia x 1.2 m deep in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio 2:1 (2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludge/Cow dung / manure after reduction by 8% flooding with water and removal of Surplus soil) complete all as specified and directed.
Preparation of beds for hedging, grass and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 1:8 (8 parts of stacked volume orf earth after reduction by 20% : one parts of stacked volume of sludge or manure after reduction by 8%) flooding with water, filling with earthnecessary, watering and finally dressing, levelling etc, including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling, within a lead of 250m and upto 1.50 KM complete all as specified and directed.
DURANTA GOLDEN - 25-30cm Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 1:8 by volume (8Parts of stacked volume of earth after reduction by 20%) One parts of stacked volume of sludge or manureafter reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lift complete all as specified and directed.
Providing Manpower (one Mali/Gardener) to maintain the garden/trees /grass/ hedges after completion of the landscaping /plantation work at site watering, including replacing the shrubs tree, if any, with the existing plants, prunng dried branches once in every week, depositing the material at place as directed by Engr-in-Charge. Note: (a) All the equipments supplied shall confirm to relevant Standerds/ IS with latest amentments. (b) Contractor should intimate the Department for factory inspection before dispatch. (c) Testing shall be done at site in the presence of Rep of Accepting officer all as directed. (d) Diesel required for testing shall be supplied by the contractor and unit rate quoted by the contractor shall deemed to be included.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .