Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance OLD NO 2C NEW NO 7 1 THANGAVELU VAITHIYAR STREET CORPORATION MIDDLE SCHOOL TRIPLICANE CHENNAI 600005 | CHENNAI | TAMIL NADU | 600005 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance NO 1 KAMAM STREET SELAIYUR CHENNAI 600073 | CHENNAI | CHENNAI | TAMIL NADU | 600073 | Admitted-Finance |
Tender Value
₹31.2 L
EMD Value
₹62,400
Closing Date
9 Jul 2024, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
COMPREHENSIVE MAINT OF INTERNAL WIRING, FITTINGS, CONTROL,CONSOLES AND FIRE ALARM SYSTEM IN TECH AREA, ANNEXE , HANGAR INCLUDING WATCH TOWERS AND GUARD POST AT AF STATION TAMBARAM
2024_MES_659294_1
GE(AF)/TBM/8728/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
Airforce Station Tambaram
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹62,400
Yes
11 Jul 2024
12 Jun 2024
11 Jul 2024
12 Jun 2024
9 Jul 2024
27 Jun 2024
13 Jun 2024 - 20 Jun 2024
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, regulators, sockets etc to be measured seperately) and making good disturbed surface of wall, floors etc all as specified.
Point wiring complete with 1.50 sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including non metallic rigid PVC conduit accessories concealed on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxs concelled/surface in wall with 3 mm thick hylam sheet are suitable modular white cover plate with frame for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated copper conductor for continious earth wire and connected to common earth dolly for the following :-
All as per Item No 2 above for One light /fan point controlled by one 5 Amps switch.
All as per Item No 2 above but for One 3 pin 5 Amps socket outlet on same board
All as per Item No 2 above but for One 3/5 pin 5 Amps socket outlet on independent board
All as per Item No 2 above but for One call bell point controlled by one bell push
All as per item No 2 above but for one 3/5 pin socket outlet 15 Amps independent with cable 2.5 Sq mm size.
All as per item No 2 above but for one 3/5 pin socket outlet 15 Amps independent with cable 4 Sq mm size.
Point wiring complete with 1.50 sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including PVC casing & caping/PVC conduit on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxs concelled/surface in wall with 3 mm thick hylam sheet for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated copper conductor for continious earth wire and connected to common earth dolly for the following :-
All as per Item No 9 above for One light point/fan point controlled by one 5 Amps switch.
All as per Item No 9 above but for One 3 pin 5 Amps socket outlet on same board
All as per Item No 9 above but for One 3/5 pin 5 Amps socket outlet on independent board but below the switch board of light points in same vertical plane with cables 1.5sqmm .
All as per Item No 9 above but for One 3 pin 5 Amps socket outlet on independent board
All as per item No 9 above but for one 3/5 pin socket outlet 15 Amps independent with cable 2.5 Sq mm size.
All as per item No 9 above but for one 3/5 pin socket outlet 5 Amps independent with cable 2.5 Sq mm size.
All as per item No 9 above but for one 3/5 pin socket outlet 15 Amps independent with cable 4 Sq mm size.
Supply and fix in repairs in attending complaints for the following items including disconecting, removing, and connecting into electric circuit and testing complete all as specified:-
Supply and fix in replacement of Modular switch 1 way 6A, 1 module all as specified and as directed .
Supply and fix in replacement of Modular switch 1 way 16A, 1 module all as specified and as directed.
Supply and fix in replacement of Modular socket 6A 2/3 pin combined 2 module all as specified and as directed.
Supply and fix in replacement of Modular socket 6A/16A 2/3 pin combined 2 module all as specified and as directed.
Supply and fix in replacement of Modular Fan regulator 120 W 2 Module suitable for 1200mm/1400mm sweep fan all as specified and as directed.
All as per Item No.16 above for Switch piano flush type 5 Amps ,Single pole one way.
All as per Item No.16 above for Switch piano flush type 15 Amps ,Single pole one way.
All as per Item No.16 above but for Switch socket combination flush type 2 in 1, 5 pin 5 Amps 240 V
All as per Item No16 above but for Switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal.
All as per Item No.16 above but for Fan regulator step type electronic flush/switch type/socket type , suitable for 1200mm /1400 mm sweep fan.
All as per Item No.16 above but for PVC ceiling rose two to three terminal plate and jumbo type
All as per Item No.16 above but for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.
All as per Item No.16 above but for Bell push Flush type 5 Amps
All as per Item No.16 above but for Call bell 230 volts single pole A/C multimusic fancy type ding dong bell.
Supply and fixing in replacement of Switch flame proof rotary type with termination box inLM6, 16A, single pole 250V
Supply and fix in replacement of laminated hylum sheet 3 mm thick as per site required sie of 4''x4'' including cutting holes for fixing the switches /sockets etc and transfering all the switches/sockets including disconnecting and reconnecting into electric circuit and testing all as specified and as directed.
Supply and fix in replacement of laminated hyleum sheet 3 mm thick as per site required sie of 6''x8'' including cutting holes for fixing the switches /sockets etc and transfering all the switches/sockets including disconnecting and reconnecting into electric circuit and testing all as specified and as directed.
Supply and fix in replacement of laminated hyleum sheet 3 mm thick as per site required sie of 12"x8'' including cutting holes for fixing the switches /sockets etc and transfering all the switches/sockets including disconnecting and reconnecting into electric circuit and testing all as specified and as directed.
Supply and fix, in replacement, MCB DB SPN double door, 4 way 240 V neutral link, earth link all as specified and as directed.
All as per Item No.34 above but for MCB DB SPN, double door, 8 way 240 V with 200 A rated bus bar neutral link, earth link all as specified and as directed.
Supply and fix in replacement for MCB DB TPN 4 way vertical type double door complete including 200A rated copper bus bar, and netral and earth link suitable with MCB TPN as incommer all as specified and as directed.
Supply and fix in replacement for MCB DB TPN 6 way vertical type double door complete including 200A rated copper bus bar, and netral and earth link suitable with MCB TPN as incommer all as specified and as directed.
Supply and fixing in replacement for MCB SP 06 to 32 Amps, 10KA 240 volts,50Hz all as specified and as directed.
Supply and fixing in replacement of MCB SPN 05 to 40 Amps 10KA 240 volts all as specified and as directed.
Supply and fixing in replacement of MCB TP 63 Amps 10KA 415 volts all as specified and as directed.
Supply and fix in replacement of MCB TPN 63 Amps 10KA 415 volts all as specified and as directed.
Supply and fix in replacement of MCB TP 100 Amps 10KA 415 volts all as specified and as directed.
Supply and fix in replacement of Single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 Volts all as specified and as directed.
Supply and fix in replacement of MCCB 25 to 100 Amp 3 pole 16 KA breaking capacity 415 Volts all as specified and as directed.
Taking down existing sub main wiring any description along with PVC conduit/ casing capping and made good the disturbed surfaceall as specified and as directed.
M & L for circuit/sub main wiring complete with 2 X 2.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through existing surface/recessed steel/PVC conduit and accessories with 1 X 2.5 Sqmm of PVC FRLS copper cable for earth continuity all as specified, dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and as directed.
M & L for circuit/sub main wiring complete with 2 X 4 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories on surface of wall roofs etc with 1 X 4 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and as directed.
All as per item No.47 here in before but for 2 x 6 Sqmm conductor with 1 x 6 Sqmm as earth continuity copper conductor. Note for Sl items No.47 to 49 : Two runs of cable , one run of earth continuity cable and PVC conduit together shall be measured as one unit length.
M & L for circuit/sub main wiring complete with4 X 4 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through existing surface/recessed steel/PVC conduit and accessories with 1 X4 Sqmm of PVC FRLS copper cable for earth continuity all as specified, dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and as directed.
M & L for circuit/sub main wiring complete with 4 X 6 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories on surface of wall roofs etc with 1 X 6Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and as directed.
All as per item No.47 here in before but for 4 x 10 Sqmm conductor with 1 x 10 Sqmm as earth continuity copper conductor. Note for Sl items No.50 to 52 : Two runs of cable , one run of earth continuity cable and PVC conduit together shall be measured as one unit length.
Supply and fix in replacement of LED 36 Watt fitting aesthetically Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling designed 2'x2' flat pannel suitable to false ceiling including provision of suitable flexiable PVC wire from ceiling rose to fittings all as specified and as directed. (make :- Havells cart part No PLANO2X2PLR36WLED857S or Equivalent from list of Makes)
S & F in replacement of Wall mounted light fitting LED batten, extruded aluminium heat sink provided for effcient heat dissipation & integrated electronic driver with 20 W LED 6500K (4 ft) lamp including disconecting, removing, and connecting into electric circuit and testing all as per Havells Cat part No.LUMILINEBS20WLED840SPCWH or Equivalent from list of Makes all as specified and as directed. .
Supply and fix surface and wall mounted 10 Watt LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & intergrated electronic driver including LED lamp complete all as per Havells Cat No.LUMILINEBS10WLED865SPCWH or Equivalenet make from list of makes including testing all as directed by Engineer- in- charge.
supply and fix in replacement Regal batten suitable for T5 and T8 lamps for fixing of LED crystal glass light as per Havells Cat part No REGALBATTEN 8 UPT0 1X22 WDSBSWH Equivalent make of in Philips/Crompton including testing all as directed by Engineer- in- charge
supply and fix in replacement ultra bright led polycarbonate tubelight with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders having driver with tHd<15% l as per Havells Cat part No PHOTONULTRA2.01213T8SSTL20WLED865PC Equivalent make of in Philips/Crompton including testing all as directed by Engineer- in- charge
S&F in replacement of security light fitting LED luminares New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light source with 35 W LED 5000K lamp all as per Havells Cat No ENDURASUNDOWNSL35WLED765PASYBOPCIHD or Equivalent from list of Makes all as specified and as directed. .
M&L GI Bracket bend to shape in cold or hot 40mm bore medium grade and 1.50 M long with suitable MS clamps and nuts bolts etc, to fixing security light fittings to Bldgs complete after taking down the unsv GI bracket all as specified and directed.
Supply and fix energy saving environmental friendly, long life pressure die cast aluminium housing flood light 100W with PC difused lens enclosure over LED for glare light with resistance of IK07 built in surge protection all as JETAARDON of Havells or equivalenet make in Philips/wipro including disconecting, removing, and connecting into electric circuit including testing all as directed
Supply and fix in replacement of Gazella Highbay Energy saving LED 100 Watt environment friendly & robust Mediumbay /Highbay LED luminaire with high efficacy (100lm/W)all as per Havells cart part No GAZELLAHBP100WLED857PBOTG 9405 or or equivalenet make in Philips/wipro including disconecting, removing, and connecting into electric circuit including testing all as directed
Supply and fix in replacement PL lamp 36 watt sutiable for 2 X 2 recess mounted light fittings Ultra bright LED PLL with very high efficacy suited for installation in existing 2G11 lamp holders to give glare free light all as per cart part No HERCULESPLL419TL 18WLED865SPC or Equivalent from list of Makes all as specified and as directed. .
Supply and fix in replacement LED drive 36 Watt suitable for 2"X2" fitting all as specified and as directed
S&F in replacemnt of post top 25 Watt light fittings LED luminaire CORAL LED post top new generation IP 65 led post of family,energy saving, environmental friendly,long life aesthetically designed with symertical light distrubution,spun aluminium landscap luminaire with high power LEDs as light source.Opal cover offers soothing uniform illumination for different applications.as per Havells cart part No CORALPT25WLED830SSYMTOPC or Equivalent from list of makes including testing all as specified and directed
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all as specified and as direcetd .
Supply only 3 core PVC insulate aluminium conductor 4 sqmm for making connection from light fittings all as directed.
Supply and fixing LED highbay light fittings 1x200W and protection IP 67 Havells Cat No. SAUCERGENXADVPROHBP 200W LED , with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all as specified and as direcetd .
M&L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to GI earth lead wire 4.0mmdia by means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSR Pt I. The work shall inclusive of necessary earth work and PCC chamber 1:3:6 in type CI with 8mm CTD bar reinforcement both ways at 140 mm bents to centre complete all as specified and as directed including taking down old unserviceable earthing .
Routine,checking of fire alarm sysyem complete with electronic control panel consisting of 10 zones in simulator Building and SRE Building including attendance of alarm personnel to attend the fire alarm system faults, testing ,checking including replacement of unserveceable componts other than mentioned below Note:- Checking shall be done every Quarter The Fire alarm sysstem consisting the following at Simulator complex :-a) Addresable fire alarm Pannel-01 Nos b)Addresable Smoke Detectors-108 Nos c)Addresable MCP-08 Nos d)Strobe cum hooter -08 Nos e)Responds Indicator -50 Nos f) Convention fire alarm Pannel 4 Zone -3 Nos,(4 zone-02 Nos,3 Zone -01Nos) at SRE Complex :- a)Smoke Detectors -20 Nos b)Multi senson detectors -09 Nos c)MCP-06 Nos d)Strobe cum hooter-05 Nos for checking, cleaning ,pannel working Overall system working condition and make the report to submit the respective person if any fault present in pannel will be checking fault finding and retification will cover in the routine Maint cost if any replacement of device and cable laying material supply installation of device laying cable will be additional cost not covered in Routine maint and replacement of items shall be Measured and paid seperately under relevent items all as specified and as directed.Note:- Contractor should provide all the T&P like Ladder, safety belt,including site Clearence, power supply service to carry out maintainance and all asr Including above qouted rates.
supply and fixing in replacement of Addressable manual call point resettable type including all fixing Accessories Make :-Moniti Raval/Morely or Equivalent as approved.
M L for Replacement of Analog addressable multisensor -Heat and smoke combination detectors complete all as specified and as direcetd.Make :-Moniti Raval/Morely or Equivalent as approved.
Supply and fixing in replacement of Installation Addressable Electronic sounder cum strobe including all fixing Acessories Make :-Moniti Raval/Morely or Equivalent as approved.
Supply and Laying on wall /floor/roof 2 core 1.5 Sqmm copper armoured cable as directed.
Supply and fix in replacement of 12v,7 AH Battery all as specified and as direcetd
Supply and fix in replacement of Responds Indicator all as specified and as direcetd Make :-Moniti Raval/Morely or Equivalent as approved.
Supply and fix in replacement of Addressable Smoke Detector all as specified and as direcetd Make :-Moniti Raval/Morely or Equivalent as approved.
SJM CONSTRUCTIONS
M/s Bakiyalakshmi Enterprises
Vishwa Enterprises
NAVEEN ENTERPRIESES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .