Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.1 LQualified Make: PARADYNE
Model: PDFN3-1000-972 B 187 DDA SHED OKHLA INDUSTRIAL AREA OKHLA INDUSTRIAL AREA PHASE I NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | Make: PARADYNE
Model: PDFN3-1000-972 | L1 | Qualified | |
| 2 | L2₹1.1 L+₹9,120 (8.64%)Qualified Make: BPE
Model: BPE 1KVA OFFLINE UPS FLAT NO 14 SR LGF KRISHNA MARKET LAJPAT NAGAR 1 NEW DELHI DELHI 110024 | SOUTH EAST DELHI | DELHI | 110024 | Make: BPE
Model: BPE 1KVA OFFLINE UPS | L2 | Qualified | |
| 3 | L4₹1.2 L+₹17,280 (16.4%)Qualified Make: BPE
Model: BPE LI NIY UPS 1000 1 KVA 216 VAH Mild Steel 1YR AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE LI NIY UPS 1000 1 KVA 216 VAH Mild Steel 1YR | L4 | Qualified | |
| 4 | L5₹1.3 L+₹19,936 (18.9%)Qualified Make: PARADYNE
Model: PDFN3-1000-972 415 4TH FLOOR VISHWADEEP TOWER DISTRICT CENTER JANAKPURI SOUTH WEST DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | Make: PARADYNE
Model: PDFN3-1000-972 | L5 | Qualified | |
| 5 | L7₹1.3 L+₹25,120 (23.8%)Qualified Make: PARADYNE
Model: PARADYNE 1 KVA 216 VAH (PDFN3-1000) 40A 8 I ST FLOOR ASHOK NAGAR NEW DELHI DELHI 110018 UDYAM DL 11 0006731 | WEST DELHI | DELHI | 110018 | Make: PARADYNE
Model: PARADYNE 1 KVA 216 VAH (PDFN3-1000) | L7 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
31 May 2018, 3:00 pmClosed
Line Intractive UPS with AVR Experience with Gov. Required 5 Year (s) Line Intractive UPS With AVR ( 32 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/216 1.0/216 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz Degree of protection IP-21 IP-21 Inverter Efficiency (%) >/= 70% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year
2 Years
5 Years Installation and commissioning instructions No - CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for printer (not through Yes Yes
No 1/4 inverter) Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 degree for 16 Hrs as Yes - 2/4 per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date 81000043 DATED – JUN -16 - Name Of Lab BIS REGISTERED AND ETDC (GOVT OF INDIA LAB) - Address of Lab BIS DELHI AND ETDC MOHALI PUNJAB (GOVT OF INDIA LAB) - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Amit Sharma 110001
ADDL DTE GEN TERRITORIAL ARMY GS BRANCH IHQ OF MOD (ARMY) L BLOCK CHURCH ROAD 32 45 EMD Required No ePBG Required No
111924
GEM/2018/B/15972
Line Intractive UPS with AVR
45 days
Delhi; New Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Experience with Gov. Required 5 Year (s) Line Intractive UPS With AVR ( 32 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/216 1.0/216 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz Degree of protection IP-21 IP-21 Inverter Efficiency (%) >/= 70% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years Installation and commissioning instructions No - CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for printer (not through Yes Yes | - | - | - |
| No 1/4 inverter) Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 degree for 16 Hrs as Yes - 2/4 per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date 81000043 DATED – JUN -16 - Name Of Lab BIS REGISTERED AND ETDC (GOVT OF INDIA LAB) - Address of Lab BIS DELHI AND ETDC MOHALI PUNJAB (GOVT OF INDIA LAB) - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Amit Sharma 110001 | - | - | - |
| ADDL DTE GEN TERRITORIAL ARMY GS BRANCH IHQ OF MOD (ARMY) L BLOCK CHURCH ROAD 32 45 EMD Required No ePBG Required No | - | - | - |
Exempted
31 May 2018
21 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_111924.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .