Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-Finance 113 F BLOCK HOUSE NUMBER 113 F BLOCK PANKI KANPUR NAGAR UTTAR PRADESH 208020 | KANPUR NAGAR | UTTAR PRADESH | 208020 | L1 | Accepted-Finance First lowest. | |
| 2 | L2₹1.5 L+₹10 (<0.01%)Accepted-Finance | L2 | Accepted-Finance Second lowest. | |
| 3 | L3₹1.5 L+₹20 (0.01%)Accepted-Finance 222 346 LUKERGANJ LUKERGANJ LUKERGANJ ALLAHABAD UTTAR PRADESH 211003 | PRAYAGRAJ | UTTAR PRADESH | 211003 | L3 | Accepted-Finance Third Lowest. |
| Sl No | Description | Qty | Unit | M/S OM SHANTI ENTERPRISES L2 | B.R. ENTERPRISES L1 | M/S New Sharma Electricals L3 |
|---|---|---|---|---|---|---|
| 1.00 | i) Inspection & rectification of SF-6 gas leakage from R&B Phase CB pole of 132KV spring charging SF-6 Circuit breaker (M/s ABB make) of 132KV Cantt bay installed at 132KV S/S Manauri, Kaushambi under ETD-IV, Prayagraj. This work includes opening of R & B phase assembly from upper & lower terminal flanges, cleaning of all groves of flanges and porcelain with petrol, scrubber pad & acrylic solution along with replacement of all damaged gasket/ O rings/ sealing rings/Guide rings/K-slot rings and damping gasket. This work also includes replacement of K slot ring of drive mechanism of 132KV spring charging SF-6 CB of said 132KV Bay by new K slot ring installed at 132KV S/S Manauri, Kaushambi.
(K-slot ring, gasket having IS-45513 specification having all type test approved suitable for 145KV M/s ABB make CB will be provided by contractor by their own cost & risk from original proprietor)
(ii) Replacement of defective short piston magnetic valve with new one. (Magnetic piston suitable for 145KV M/s ABB make CB will be provided by contractor by their own cost & risk from original proprietor)
(iii) Inspection & rectification of short circuit of wiring in DC circuit of T/F breaker to protect blowing of fuses by detecting the fault/damaged insulation of control wiring of switch cubical, control block and all the wiring up to the control room & replacement/ repairing of damaged wiring. | 2 | Nos | 74,995 ₹1,49,990 | 74,990 ₹1,49,980 Lowest | 75,000 ₹1,50,000 |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
25 Jan 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer ETD-IV, 57 George Town, Prayagraj
For attending SF6 gas leakage from R and B phase pole of 132 KV spring charging SF6 circuit breaker of 132 KV Cantt bay at 132 KV SS Manauri Kaushambi
2025_UPTCL_994386_1
09-ETD-IV(P)/2024-25
Open Tender
Electrical Works
Item Rate
132 KV Manauri
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Executive Engineer ETD IV Prayagraj
₹2,000
13 Oct 2025
18 Jan 2025
25 Jan 2025
18 Jan 2025
25 Jan 2025
18 Jan 2025
Amount
i) Inspection & rectification of SF-6 gas leakage from R&B Phase CB pole of 132KV spring charging SF-6 Circuit breaker (M/s ABB make) of 132KV Cantt bay installed at 132KV S/S Manauri, Kaushambi under ETD-IV, Prayagraj. This work includes opening of R & B phase assembly from upper & lower terminal flanges, cleaning of all groves of flanges and porcelain with petrol, scrubber pad & acrylic solution along with replacement of all damaged gasket/ O rings/ sealing rings/Guide rings/K-slot rings and damping gasket. This work also includes replacement of K slot ring of drive mechanism of 132KV spring charging SF-6 CB of said 132KV Bay by new K slot ring installed at 132KV S/S Manauri, Kaushambi. (K-slot ring, gasket having IS-45513 specification having all type test approved suitable for 145KV M/s ABB make CB will be provided by contractor by their own cost & risk from original proprietor) (ii) Replacement of defective short piston magnetic valve with new one. (Magnetic piston suitable for 145KV M/s ABB make CB will be provided by contractor by their own cost & risk from original proprietor) (iii) Inspection & rectification of short circuit of wiring in DC circuit of T/F breaker to protect blowing of fuses by detecting the fault/damaged insulation of control wiring of switch cubical, control block and all the wiring up to the control room & replacement/ repairing of damaged wiring.
M/S OM SHANTI ENTERPRISES (BID ID -4881290)
M/S New Sharma Electricals (BID ID -4881372)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .