Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.2 L+₹22,280 (11.3%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Hard Copy not submitted by the contractor. |
Tender Value
₹2.2 L
EMD Value
₹4,435
Closing Date
16 Nov 2022, 9:30 amClosed
Executive Engineer
EE, EandM, Division, APWD, Prothrapur, Port Blair
Modification of Old Ambulance Shed for Utilization as Jan Aushadi Generic Store under PMJAY at PHC Hut Bay under AE I MID APWD Hut Bay SW Providing IEI
2022_APWD_7838_1
NIT No 35/EE/EandM/22-23
Open Tender
Electrical Works
Item Rate
45 days
South Andaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹4,435
26 Dec 2022
28 Oct 2022
16 Nov 2022
28 Oct 2022
16 Nov 2022
3 Nov 2022
29 Oct 2022 - 2 Nov 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. a) Group-C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying of AC Ceiling Fan (1200 mm) Sweep 5 Star Rated ISI Marked without regulator i/c wiring down rod of standard length (upto 30 cm) with all accessories similar to Bajaj Code No. 250467/68 KASSELS - 50- ISI or its equivalent
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying Installation Testing and Commissioning of 20W LED CRCA batten with decorative end cap complete with retrofit polycarbonate / glass Tube as equivalent to C&S CRUX - i/1X20W Order No, LTDC01220WLED/WD or its equivalent Fitting
Supplying and fixing PVC batten/ angle holder including connections etc. as required
Supplying of 9 W LED Lamp directly fitted in Batten Holder as equivalent to C&S CHANDRA/9W/W/B22 Order Code LTHPEDLEMP9W/B22BULB or its equivalent etc., as requried.
Supplying, Installation, Testing and Commissioning of 10 W Plastic Housing with clear prismatic diffuser bulk head LEDs, IP65 protection as equivalent to C&S e-TARA Series, e-TARA/10W, Order No. CG80IB10WLED or its equivalent Fitting.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. a) 63 A TP&N
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way , Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single Pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 A
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2 mtr, outer dia 50 mm, inner dia 19 mm and inner space be filled with crystalline conductive mixture including filling -up with electrolite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok)
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying of following XLPE insulated heavy duty armoured aluminium conductor UG cable of 1.1 KV grade conforming to IS: No. 7098 (Part-I) and IS: No. 1554 (Part-I) 1958 as applicable Make (Clooster/ Havells/ Polycab/RR Cable etc., as required. a) 25 Sq.mm x 3.5 Core
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. a) Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required a) Upto 35 sq. mm (clamped with 1mm thick saddle
Supplying and Laying of One Number double walled corrugated high density polythylene Pipe having corrugation on the outer wall and plain surface inner wall confirming to IS 14930 part I complete with necessary HDPE fitting for protection of 1.1 KV grade under ground cable directly in ground at the depth of 50 cm in the existing cable trench etc., as required. a) 77/63 mm
Supplying and Laying of One Number double walled corrugated high density polythylene Pipe having corrugation on the outer wall and plain surface inner wall confirming to IS 14930 part I complete with necessary HDPE fitting for protection of 1.1 KV grade under ground cable directly on the surface of wall etc., as required. a) 77/63 mm
SITC of 02 Ton 5 Star Rating (As per 2018 BEE Star Rating) Invertor High Wall Split Type Air Conditioner (Rotary Compressor 1 Phase 220 V) Make HITACHI Model RMOS524HCEA or its equivalent Model in HITACHI / O GENERAL with maximum cooling capacity of atlest 7000 watts (with copper condenser) i/c standard refrigerant copper pipe kit, cementing, painting to give an even look and smooth finish, wrapping PVC non adhessive white tape over insulation of gas pipe etc, as required and as per the direction of Engineer-In-Charge
Supplying and Fixing of 5 KVA Voltage Stabilizer suitable for 2 Ton Air Conditioner as required Make: V- Guard Model VND 500 (Voltage Range 150V - 285V, 15 Amps) or its equivalent.
Providing and Fixing of Pre- Fabricated Stand for Keeping Outdoor units of 1 Ton, 1.5 Ton, 2 Ton Capacity Split Type Air Conditioner as required.
K RUDRA MURTHY
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .