Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC MOHANPUR PT LL HOUSE NO 00 CITY TOWN SILCHAR P O KATIRAIL P S KATIGORAH DISTRICT CACHAR PIN 788804 | CACHAR | ASSAM | 788804 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹40.4 L+₹1.2 L (3.10%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹41.7 L+₹2.5 L (6.46%)Rejected-Finance MAHALAKPUR NIZAMPUR AGHWANPUR ROAD AGHWANPUR MORADABAD UTTAR PRADESH 244001 | MORADABAD | UTTAR PRADESH | 244001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹42.6 L+₹3.4 L (8.67%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹43.0 L+₹3.8 L (9.63%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SEVOKE ROAD
GE SEVOKE ROAD POST SALUGARA DIST JALPAIGURI
REPAIR MAINT REPLACEMENT OF OLD CI GI WATER SUPPLY PIPE LINE AND CONNECTED E/M ITEMS AT VARIOUS LOCATION OF SEVOKE MIL STN UNDER GE SEVOKE ROAD
2020_MES_388813_3
GE/SEV/23 OF 2020
Open Tender
Civil Works
Item Rate
270 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE SEVOKE ROAD
₹80,000
Yes
15 Feb 2021
30 Dec 2020
15 Jan 2021
30 Dec 2020
13 Jan 2021
1 Jan 2021
31 Dec 2020 - 31 Dec 2020
60 days
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out excavated material for laying/ taking out pipe line in soft/ loose soil complete all as specified and directed
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in each layer in soft/ loose soil complete all as specified and directed
Removal of surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
Taking up or down from any position existing GI water tubing and connections carefully including cleaning for refixing or removal to E/M store yard complete all as specified and as directed for following sizes:- Note :- Excavation/earth work shall be measured and paid seperately under respective item
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
Relaying/Fixing old serviceable water tubing, jointing and testing as obtained from item No. 4 here-in-before in new or existing position including all new fittings, ISI Marked, such as bends, elbow, tee, reducers, sockets, unions etc as required, laid in trenches, fixed to wall/celling or floors including making holes in wall where required complete all as specified and directed by Engr-in-charge for the following sizes:-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply, laying, jointing & testing galvanised iron tubing medium grade with all fittings such as bends, elbow, tee, socket, reducers, unions etc as required at site laid in trenches complete all as specified and directed for the following sizes:-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
S&F in repair gun metal gate/globe valve, ISI Marked, with iron wheel head screwed both ends for pipe including taking down unserviceable complete all as specified and as directed the following sizes:-
50 mm bore
40 mm bore
25 mm bore
20 mm bore
Cutting of existing cast iron/DI pipes in any position for insertion and fitting of new Tee, Coller, Tail pieces etc for taking out connections, branch connections complete all as specified and directed for the following sizes:- Note :- (a) Excavation/earth work shall be measured and paid seperately under respective item of schedule. (b) Cast iron fittings shall be measured and paid seperately as supply only under respective item of the schedule
200 mm bore
150 mm bore
100 mm bore
Taking out cast iron/Ductile iron/PVC/Cemented water mains including all fittings with flanged joints/tyton joints/ spigot and socket ends for the following sizes :-
200 mm bore
150 mm bore
100 mm bore
Supply, laying, jointing and testing of Ductile iron water mains Class K-7 with spigot and socket ends including rubber gasket joints laid in trenches complete all as specified and directed for the following sizes :-
200 mm bore
150 mm bore
100 mm bore
Supply, fixing and testing DI fittings for spigot & socketed or flanged pipes i.e. bends, reducers, tail pieces, tapers, tees, collars, caps, plugs with MS plate, nuts, bolts, washers gaskets etc of sizes 80mm to 200mm dia including taking out Unserviceable complete all as specified and directed .
Supply, fixing and testing cast iron fittings for spigot & socketed or flanged pipes i.e. bends, reducers, tail pieces, tapers, tees, collars, caps, plugs with MS plate, nuts, bolts, washers gaskets etc of sizes 150mm dia including taking out Unserviceable complete all as specified and directed .
M&L for boring drilling, threading and tapping on existing cast iron mains for size 80 mm to 300 mm bore for connecting 15/20/ mm bore pipe by fixing on clamp made out of MS flat iron of size 40 x 3 mm made to required shape & size with GI socket duly welded, nut & bolts etc. complete all as specified and directed.
Repair to existing GI pipe line to prevent the leakage including cutting the pipe line in position and insertion of new fittings like sockets, tees, reducers, bends as required at site or welding of suitable size all as directed by Engr-in-charge for the following sizes :-
150 mm bore
100 mm bore
80 mm bore
50 mm bore
40 mm bore
25 mm bore
S & F Stack clamp made out of 50mm x 5mm, mild steel flat iron including nuts, bolts, gasket etc for the following sizes:-
200mm bore
150mm bore
100mm bore
80mm bore
M & L for taking out sluice valve, refacing, remetaling,regrinding and refixing of following bore dia, complete all as specified and directed:
200mm Bore
150mm bore
100 mm bore
S&F sluice valve PN 1.6 with Stainless steel spindle nuts, bolts, washers and rubber gasket sheet for packing including taking out existing unserviceable sluice valve fixed at any position all as specified and directed by Engineer-in-charge.
200mm bore
150mm bore
100 mm bore
80 mm bore
M&L for burning out Lead Joint from Cast Iron Pipes 100mm bore in position including recovering old Lead, complete all as specified and as directed. Note- Excavation & earth work if required shall be measured and paid under respective item.
M&L for burning out Lead Joint from Cast Iron Pipes 150mm bore in position including recovering old Lead, complete all as specified and as directed. Note- Excavation & earth work if required shall be measured and paid under respective item
M&L for burning out Lead Joint from Cast Iron Pipes 200mm bore in position including recovering old Lead, complete all as specified and as directed. Note- Excavation & earth work if required shall be measured and paid under respective item
M & L for run lead joints for pipes and fittings (spigot and socket ends) 100 mm bore and testing complete all as specified and directed.
M & L for run lead joints for pipes and fittings (spigot and socket ends) 150 mm bore and testing complete all as specified and directed.
M & L for run lead joints for pipes and fittings (spigot and socket ends) 200 mm bore and testing complete all as specified and as directed.
Labour only run lead joints for pipes and fittings (spigot and socket ends) 100 mm bore and testing complete all as specified and as directed.
Labour only run lead joints for pipes and fittings (spigot and socket ends) 150 mm bore and testing complete all as specified and as directed.
Labour only run lead joints for pipes and fittings (spigot and socket ends) 200 mm bore and testing complete all as specified and as directed.
S & F mechanical joint of following sizes, complete all as specified and directed:
200mm bore
150mm bore
100mm bore
Cleaning of over head/Under ground sump, RCC tank of following capacity by de- watering duly scraping the inner surface cleanig the same with bleaching powder including lime wash of the complete inner portion of tank all as directed by Engr-in-Charge. Note- (i) Cost of safty equipment such as safty belt and Scafolding etc is deem to include in item rate.
For 50,000 Gallon O/H tanks at 18 to 20 mtr height
For 40,000 Gallon O/H tanks at 18 to 20 mtr height
For 25,000 Gallon O/H tanks at 18 to 20 mtr height
For 50,000 Gallon U/G tanks ( MAP Majors Area PH)
For 1,00,000 Gallon U/G tanks ( MAP Ors Area PH)
Dismantling of GI Pipe Connections from the Pressure Filter Plant capacity 6000 to 10000 Gallons, opening the Manhole and removal/taking out old Filter Media completely from Oxidation Chamber, Pre-filter, Iron Removal Filter and depositing the same to a distance not exc. 100 Metre and re-fixing the pipes in the original/existing Position after replacement of unserviceable PVC Nozzale (Dom type) including replacement of Gasket of Manhole Cover and necessary Bolts, Nuts, Washers, etc. as required, complete all as specified and as directed.
Supply and incorporation of MNO2 of size 1/8'' x 1/10'' as filter media of iron removal plant ,complete all as specified & directed.
Supply and incorporation of GRAVEL of size 1 1/4'' x 1 1/2''(collection sourceBARAKAR river bank) as filter media of iron removal plant complete all as filter media of iron removal plant ,complete all as specified & directed.
Supply and incorporation of GRAVEL of size 1/2'' x 1''(collection sourceBARAKAR river bank) as filter media of iron removal plant complete all as filter media of iron removal plant ,complete all as specified & directed.
Supply and incorporation of GRAVEL of size 1/4'' x 1/2''(collection sourceBARAKAR river bank) as filter media of iron removal plant complete all as filter media of iron removal plant ,complete all as specified & directed.
Supply & incorporation of SAND of size 1/6" x 1/8'' mesh (collection source BARAKAR river bank) as filter media of iron removal plant complete all as filter media of iron removal plant ,complete all as specified & directed.
Supply & incorporation of Anthracite grit of size 1/8" x 1/4'' as filter media of iron removal plant complete all as filter media of iron removal plant ,complete all as specified & directed.
Supply & fixing PVC strainers of sizes as dismantled of Make: PHI/RMCO, complete all as specified & directed.
M & L Painting to External Surfaces of Iron Removal Chamber, Pre-filter Chamber, Oxidation Chamber including Pipes complete of Fiteration Plant capacity 8000 GPH with Two Coats of Sythetic Enamel Paint of approved colour over a coat of Red Oxide Primer including neccessary preparation of surfaces, complete all as specified and as directed.
M&L Painting to Internal Surfaces of Iron Removal Chamber, Pre- filter Chamber and Oxidation Chamber including Pipes complete of Filteration Plant capacity 8000 GPH with Two Coats of Black Bituminous Paint (Lead Free) suitable for Drinking Water grade including necessary surface preparation by means of scraping, brushing, cleaning, complete all as specified and as directed.
Testing of water sample of various pump houses of sevoke militry station for bacteriological and chemical testing (systematic analysis) from government approved laboratory including submitting the report to the department ,complete all as specified & directed.
M & L for Scraping old paint of Electric Panel and Painting with two coats of synthetic enameal paint over a coat of red oxide primer and the shade paint including disconnecting electric connection and re-wiring without any damage of existing parts as directed by Engnr-in-Charge complete as all specified and as directed.
M & L in replacement for fabrication of ladder for OHT & UG sump made out of MS angle / flat iron frame & MS bar including cutting welding and fixing by PCC work and painting with one coat of red oxide & two coats of Bituminous black water proof paint at site complete all as specified & directed.
Supply & fixing in repair Pressure guage of capacity 210 kg/cm2. complete all as specified and as directed.
M & L for jointing of pipe of dia upto 200mm , shifted by elephant running over the river bed and formation of two PCC pillars for supporting of each length of pipe complete all as specified and as directed.
S & F battery of 180 AH, 12 V with battery terminal and connecting cables complete all as specified and as directed.
S&F of 3 phase Digital panel volt Meter Flush Mounting 96x96mm, Accuracy Class-I, input voltage measurement range 17-520V AC (P-P), including taking out unserviceable complete all as specified and as directed.
S&F of 3 phase 5A, Digital panel ammeter Flush Mounting 96x96mm, Accuracy Class-I, CT/PT Site programmable including taking down existing unserviceable one complete all as specified and as directed.
S&F of 3 phase indicator lamp including taking down existing set complete all as specified and as directed by Engr-in-Charge
M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron frame of size 50 x 50 x 6mm and locking arrangements including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork, painting one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 1200mm x 1200mm x1200mm (internnal dimensions) including demolition of existing valve chamber,complete all as specified and as directed.
Supply and laying burnt clay sub class B brick as cable protection all as specified and directed.
Relaying only old recovered cable cover of any size in trenches all as directed by Engr-in-Charge.
Supplying & Laying in trenches Clear Sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified.
M&L for PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of pole, stay including frame work where reqd all as directed.
M&L for PCC (1:2:4) type B-1 coping 20 mm graded aggregate for grouting, finished even and smooth without using extra cement all as directed.
M & L for laying LT underground Cable, including takingdown existing u/s XLPE insulated, heavy duty armoured sheathed 1100 volts grade 10 Sq mm, 2 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete with all as specified.
All as per item No 54 above but 16sqmm, 4 core all as specified.
All as per item No 54 above but 25sqmm, 3.5 core all as specified.
All as per item No 54 above but 35sqmm, 3.5 core all as specified.
All as per item No 54 above but 70sqmm, 3.5 core all as specified.
All as per item No 54 above but 95sqmm, 3.5 core all as specified.
All as per item No 54 above but 120sqmm, 3.5 core all as specified.
All as per item No 54 above but 300sqmm, 3.5 core all as specified.
Taking down existing unserviceable/faulty LT UG cable 1100V of any size from existing location and relaying the same after necessery repair work all as specified and as directed. (Note: Items if required for repair and excavation works will be measured and paid seperately under relevant items)
Supply and fix cable joining kit for 1.1 KV grade for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 /4 core XLPE, armoured, AI conductor cable of size 25 to 50 Sqmm, Indoor/Outdoor type, including taking out & relaying damaged UG cable after repair complete all as specified and as directed. (Note: Excavation and connected items will be measured and paid separetely).
All as per item No 63 above but size 70-120sqmm, 4 core all as specified.
All as per item No 63 above but size 150-185sqmm, 4 core all as specified.
Restring/Fixing only of existing ACSR conductor any size/any type drawn on fixed to insulator on the pole complete as with permissible sags for OH Conductor as per Indian Electricity Rules 1956 - Para 77 and 79 all as specified and directed.
Labour for cutting of trees branches 2 mtr above the conductor which are touching to the HT/LT over head lines in vertically & horizontally conductor and poles etc. Complete clear in a standard span in between two poles and removing cutting material not exc 50 mtr and depositing where directed at a distance level no exc 3 mtr from starting point, minium 04 Nos of mazdoor man with ropes/cutting tools complte will be engaged for a standard one span at a forest/high gradient/any type of surfaces, follows safety measures as per IE Rules, complet all as speciied and as directed.
M & L in repair GI tubing of 40 mm bore light grade with all fitting fixed to wall/ceiling as cable protection laid on floor all as specifed and directed.
M & L in repair GI tubing of 50 mm bore light grade with all fitting fixed to wall/ceiling as cable protection laid on floor all as specifed and directed.
M & L in repair GI tubing of 80 mm bore light grade with all fitting fixed to wall/ceiling as cable protection laid on floor all as specifed and directed.
M&L MCCB 4 Pole, including taking down old u/s having current rating 400 Amp, thermal magnetic setting adjustable 70%-100% breaking capacity 36 KA at 415V,50Hz, Frame size/type CH along with spider links complete all as specified and directed.
M&L MCCB 4 Pole, including taking down old u/s having current rating 250 Amp, thermal magnetic setting adjustable 70%-100% breaking capacity 25 KA at 415V,50Hz, Frame size/type CH.along with spider links complete all as specified and directed.
M&L MCCB 4 Pole, including taking down old u/s having current rating 200 Amp, thermal magnetic setting adjustable 70%-100% breaking capacity 25 KA at 415V,50Hz, Frame size/type CH along with spider links complete all as specified and directed.
M&L MCCB 4 Pole, including taking down old u/s having current rating 160 Amp, thermal magnetic adjustable 70%-100% breaking capacity 16kA at 415V,50Hz, Frame size/type CH along with spider links complete all as specified and directed.
M&L MCCB 4 Pole, including taking down old u/s having current rating 63-100 Amp, thermal magnetic adjustable 70%-100% breaking capacity 16 KA at 415V,50Hz, Frame size/type CH along with spider links complete all as specified and directed.
M&L cutting for raod crossing, PCC hard standing for laying of cable/protection pipe including making good the existing damaged surface with same finish using PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) to matach the original finish complete all as specified and as directed.
M&L for boring horizontal holes upto 2mtr deep in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m. (Note: Connected items like Pipes is measured and paid seperately under relevant items).
M&L for repair to existing outdoor type polycarbonate panel board by replacement of existing burnt/damaged polycarbonate box IP66 of size 600x300x214mm (High Transparent Lid)-01 Nos including making connections of main busbar with main incomer MCCB and one outgoing MCCB via suitable/directed size new copper bars connected link TPN+E covered with heat-shrinkable insulation type colour coded sleeves including supply and fixing of Elecrtolytic grade main copper Busbar section TPN+E of rating min 600A covered with heat-shrinkable type colour coded sleeves including SMC/DMC insulators, nuts, bolts & washers - 01 Set all as specified and as directed by Engr-in-Charge.
M&L disconnecting the XLPE UG cable connection from existing MCCBs in the existing LT panel/feeder pillar box completely and repair the terminal point of cable by providing new cable lugs, nuts & bolts of appropriate size and crimp the cable lugs by crimping tools as per technical requirements, wrap PVC insulation tape as per colour coding and connect the cable in same way as per existing in existing MCCB complete incl excavation for taking out burried cable if required all as specified and as directed by engr-in-charge.
M & L for preperation of Metal surfaces of LT Panel/feeder pillar box (Size below 1.0x1.2x0.6m) of any description and aplying one coat of synthetic enamel paint by spray of colour match with original including cleaning grass/herbs etc from panel 1 meter nearby ground complete all as specified and as directed by the engr-in-charge
M & L for preperation of Metal surfaces of LT Panel/feeder pillar box (approx size 2.0x2.5x0.6m) of any description and aplying one coat of synthetic enamel paint by spray of colour match with original including cleaning grass/herbs etc from panel nearby ground complete all as specified and as directed by the engr-in-charge
S&F in repair Onload changeover switch 100A confirming to IS/IEC 60947/3, 4 pole 415 Volts, modular construction, positive isolation enclosed in sheet steel enclosure complete all as specified and directed.
S&F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 65mm dia for 1100 volts grade all as specified and as directed
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strip 25x4mm as earth lead by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 5 of SI part I including necessary excavation and earth work GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to LT panel board as indicated including testing complete all as specified and as directed.
M&L for replacement of steel tubular swaged poles complete with cast iron base plate, finial taper plug bolts, nuts & screw as specified type 410 SP-31, 9.0 meter long all as specified and directed by Engr-in-Charge.
M & L for Cross arms, bracings, supports, clamps fabricated rectangular pole structure ( for 33 KV CT, PT, Ganf & LA etc.) & back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending, cold or hot drilling holes for bolts, in any shape or size as indiacted or directed and inclusive of one primer coat, one under coat and one finishing coat of Aluminium paint all as directed.
S&F in repair digital time switch with quick and easy programming having precision to the second and weekly overview on display including making necessery wiring and connections complete all as specified and directed.
S&F in repair contactor 3 pole 415Volt with integrated auxilary contacts 2NO + 2NC of 50A rating including making necessery connections all as specified.
S&F earth continuty conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm aluminium strip all as directed.
SHRI JIBANDHAN PAUL
M S BHARAT CONSTRUCTION CO.
M/S ASOKE KUMAR MAJUMDER
SRI SURAJIT SENGUPTA
JHA CONSTRUCTION AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .