Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.4 LAccepted-AOC | ₹66.4 L | L1 | Accepted-AOC accepted |
| 2 | L2₹66.6 L+₹19,714 (0.30%)Rejected-AOC H NO 959 SECTOR 3 ROHTAK | ₹66.6 L+₹19,714 (0.30%) | L2 | Rejected-AOC rejected |
Tender Value
₹56.4 L
EMD Value
₹1.1 L
Closing Date
5 Aug 2022, 5:00 pmClosed
Executive Engineer
Electrical Division PWD BnR Br. Rohtak
Construction of New Building of Govt. College Dujana in Jhajjar District (Pdg. E.I. only). Recall
2022_HRY_231404_1
PWD/Electrical/123345
Open Tender
Electrical Works
Item-rate/Agreement basic
60 days
Jhajjar
Please refer to tender documents as per DNIT conditions.
3 documents required · 3 mandatory
₹5,000
₹1.1 L
Yes
2 Apr 2025
22 Jul 2022
8 Aug 2022
22 Jul 2022
5 Aug 2022
22 Jul 2022
Amount
HSR Items
Ceiling Fan / Exhaust Fan
20.71 Supply, Erection, Testing of Ceiling Fan IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-Charge
20.72 Supply, Erection, Testing of Exhaust Fan IS marked (as per IS code 374)having a capacity of 45 cubic meter per minute complete with suitable GI sheet ducting in structure confirming to latest IS specifications complete in all respects complete to satisfaction of Engineer-in-Charge
23.1 Copper Wiring in MS Conduit (Surface/Recess)
23.1.1 Wiring for Light/Fan/Call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick conduit pipe.
23.1.1.2 Group B
23.1.2 Wiring for Twin control light point with 2 Nos. 2 way, 5 amp. switch in 1.5 Sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe.
23.1.2.2 Group B
23.1.4 Wiring in MS conduit system for 3 pin 5 amp. plug point by using 2 no. 1.5 sqmm FRLS copper wire and 1 No. 1.5 Sqmm FRLS copper wire, including providing 2 no. 5/6 Amp 3/5 pin socket and 1 no. 5/6 Amp switch required MS Box etc complete as required
23.1.4.2 Group B
23.1.5 Wiring in MS conduit system for 3 pin 15 amp. plug point by using 2 no. 4 sqmm FRLS copper wire and 1 No. 4 Sqmm FRLS copper wire foe earthing, including providing 2 no. 15/16 Amp 3/6 pin socket and 1 no. 15/16 Amp switch required MS Box etc complete as required
23.1.5.2 Group B
23.1.6 Wiring main sub mains and circuit wiring in Two single core for phase and neutral wire and one single core for each wire PVC insulated copper conductor cable 1100 volts grade in MS conduit etc complete as required
23.1.6.1 1 run of size 1.50 Sqmm (1/1.40 mm)
23.1.6.3 1 run of size 4 Sqmm (1/2.24 mm)
23.1.6.4 1 run of size 6 Sqmm (1/2.80 mm)
23.1.6.5 1 run of size 10 Sqmm (1/3.50 mm)
23.6.6 Supply and Erection of MS conduit pipe 1.6 mm thick, ISI marked surface / recessed in slab / wall / ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of work
23.6.6.1 M S Pipe of 20 mm dia
23.6.6.2 M S Pipe of 25 mm dia
23.7.6 Supplyand erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspectionboxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-charge of work.
23.7.6.2 PVC pipe of 25 mm dia
23.8 Fittings and Accessories.
23.8.1 Providing and fixing Paino type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connection, complete in all respect
23.8.1.12 Bakelite angle / straight button holder large size.
23.8.1.13 Socket size rotary step type Electronic regulator for AC ceiling fan
23.8.4 Supply and erection of 10.5 cm dia MS Fan box including 8 mm dia 30 cm long MS road made into suitable suspension hook and erected in RCC slab for the erection of fan complete with all labour and material required to complete the job
23.9 Erection of Exhaust fan in existing opening, complete with necessary earthing of Fan including carriage from PWD store to the site of work.
23.11 Making suitable hole in the wall suitable for exhaust fan upto 450 mm sweep including finishing the same and fixing of stainless steel wire mesh 2 mm thick having about 50 meshes per inch at exhaust side complete as required.
23.22 MCCB, Distribution Boards, MCB's, RCCB's, Change Over etc.
23.22.1 Supply and erection of modular case circuit breaker single pole / 4 pole on existing wall / pedestal / panel including bounding to earth and making necessary connections required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work.
23.22.1.3 Triple Pole MCCB 16 to 100 Amp., 25 KA
23.22.1.11 4 Pole MCCB 200 to 250 Amp., 25 KA
23.22.1.12 4 Pole MCCB 300 to 400 Amp., 50 KA
23.22.2 MCCB enclosure made of sheet steel suitable for mounting MCCB of following ratings
23.22.2.1 MCCB upto 125 A FP
23.22.3 Supply and erection of Sheet Steel Enclosure 1pole/2 pole/4 on wall/on existing pedestal complete as required.
23.22.3.1 SP enclosure suitable for single pole MCB
23.22.4 Supply and erection of double door sheet steel enclosure distribution boards suitable for MCB's & ELCB's recessed in wall including bonding to earth complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work.
23.22.4.11 Vertical TPN DB Double Door 8 way (8 incoming 3 phase*8 outging)
23.22.4.12 Vertical TPN DB Double Door 12 way (8 incoming 3 phase*12 outging)
23.22.5 Supply and erection of miniature circuit breaker 240/ 415 V in the existing distribution board including making necessary connections
23.22.5.1 6 Amp. to 32 Amp. Single Pole
23.22.5.5 6 Amp. to 32 Amp. MCB'S TRIPLE POLE
23.22.5.6 40 Amp. to 63 Amp. MCB'S TRIPLE POLE
23.24.4.4 Load Bank 8 way 400 Amp.
24.1 Earthing and Lightening Arrestor
24.1.1 Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. (but without charcoal or coke and salt) as required
24.1.2 Extra for using salt and charcoal/coke for earth electrode as required.
24.1.3 Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt ) complete as required
24.1.4 Earthing with tinned copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
24.1.5 Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode
24.1.7 Supplying and Laying 25mm x 3mm G.I. Strip in 40mm dia GI pipe as/from earth electrode including soldering etc. as required.
24.1.9 Providing and fixing 25 mm x 5mmm copper strip in 40 mm dia G.I. pipefrom earth electrode as required
24.1.11 Providing and laying earth connections from earth electrode with 4.00 mm dia GI wire in 15 mm dia GI pipe from earth electrode as required.
24.5.2 S/E of mark double walled corrugated (DWC) HDPE pipe10 Kg./Cm2 laid 0.75 mtr. below ground level including digging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-incharge of the work
24.5.2.3 DWC/HDPE pipe 63/50 mm outer dia / inner dia
24.5.2.4 DWC/HDPE pipe 90/75 mm outer dia / inner dia
24.4.16 Supply and erection of weather proof M.S. box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S. sheet hinged cover, locking arrangement, housed in wall, including the cost of 1 no. 16 amp. 415 volts SP MCB and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board/10 mm Bakellite sheet in the M.S. box including painting and necessary connections
M.R. Items
NS-1 Supply & erection of double door (Indo Asian / Havells / standard make) sheet steel enclosure distribution board (Suitable for MCCB as incomer and MCB for out going circuit but with out cost of MCCB / MCB etc. The distribution board duly recessed in wall / surface mounting necessary connections with all labour & material required to complete the job in all respect up to entire satisfaction of Engineer-in-charge of the work.
NS-2 S/E of underground cable loose in existing pipe or trenches complete in all respect upto the entire satisfation of Engineer-in-Charge of the work.
i) 10 Sqmm 4 Core Cable (Armd.)
ii) 25 Sqmm 3.5 Core Cable (Armd.)
iii) 50 Sqmm 3.5 Core Cable (Armd.)
iv) 120 Sqmm 3.5 Core Cable (Armd.)
N.S - 3 Supply and Erection of LED flood light Luminaire 250W of Makes: Havells make JETAVALOUR FL 240 W LED 757 MODWBLTG or its equivalent models and specifications of Philips /Wipro /Bajaj make with lense with high power LED flood light in aluminium PDC housing, toughened glass cover with IP 66 protection and accessories required to complete the job in all repect including erection an making connection with other petty material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work.
N.S - 4 Supply & erection of M.S. Box made of 16 Gauge of size d 8" x 10" x 4" covered with3 mm thick bakelite sheet white colour of ISI Mark fixed by means of 4 Nos. brass screws with cost of 1 No. 15 Amp. multi socket of ISI Mark and 15 Amp. switch and 3 Nos. 5 Amp. multi-socket with 5 Amp. switches of ISI Mark including fixing the M.S. Box in wall with cost of cement sand mixture including painting of M.S. Box and to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of the work. (Based on HSR)
N.S - 5 Supply and erection of MS Saddle and clamps duly galvanised , on wall / RCC parapit for fixing underground cable at a distance of 0.60 metre center to center fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect and upto entire satisfaction of the Engineer-in-charge of work. (Based on Old HSR 31.48)
N.S - 6 Supply and erection of MS stand made of 50mmx50mmx6mm angle iron frame and 150cm long, 30cm wide with MS sheet covering size 30cmx30cm 3.15mm thick fixed on the top of board & legs duly embedded in 1:2:4 cement concrete block 30cm below ground level including the cost of cement sand, welding, painting & fabrication charges etc. up to the entire satisfaction of Engineer - in - charge of the work. (Based on Old HSR 31.51)
N.S - 7 Supply and Erection of LED Tube fitting with all accessories as supplied by the manufacturer complete in all respect. Make: Philips/Wipro/Havells
i) LED Tube Light Fitting 18 W
ii) LED Tube Light Fitting 40 W
iii) LED 40 W Panel 2'x2'
DEVENDER KUMAR CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .