Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-Finance BEING L1 | |
| 2 | L2₹16.9 L+₹1.5 L (9.77%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹18.0 L+₹2.6 L (16.7%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹18.3 L+₹2.8 L (18.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹19.2 L+₹3.8 L (24.7%)Rejected-Finance 180 SECTOR 1 CHANNI HIMMAT CHANNI HIMMAT JAMMU JAMMU JAMMU AND KASHMIR 180015 UDYAM JK 07 0006292 | JAMMU | JAMMU AND KASHMIR | 180015 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
30 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA C/O 56 APO
REPAIR/REPLACEMENT OF SECURITY LIGHTS, FLOOD LIGHTS WITH OTHER CONNECTED ITEMS AT 213 TRANSIT CAMP UNDER GE NAGROTA.
2021_MES_485299_1
GEN-58/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAGROTA
Class D and above and Category b(I)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹60,000
Yes
30 Dec 2021
30 Oct 2021
2 Dec 2021
30 Oct 2021
30 Nov 2021
15 Nov 2021
60 days
Amount
Taking doen security light fitting HPSV/HPMV/HPMH/Post top lanterns/flood light/LED light fittings etc of any capacity from any geight any situation and re-fixing/re-hanging the same in existing location or other location after carrying out repair works on light fittings including testing complete all as specified and directed by Engr-in -Charge Note: (i) The rate quoted for the above tiems shall be deemed to be included for necessary charges for replacement of the all defective parts/fitting but cost of fittings viz ballast of any type ignitor , holder , lamp /tube /LED lamp of any capacities requried will be measured and paid separately under appropiate items of Sch 'A' here in after
Supply & fixing in replacement Heavy duty copper wound ballast(choke) for HPSV/MH street light/flood light fitting of 70 watts, complete all as specified and as directed.
Supply & fixing in replacement Heavy duty copper wound ballast(choke) for HPSV/MH street light/flood light fitting of 150 watts, complete all as specified and as directed.
Supply & fixing in replacement Heavy duty copper wound ballast(choke) for HPSV/MH street light/flood light fitting of 250 watts, complete all as specified and as directed.
Supply & fixing in replacement Lamp electric srew type HPSV/MH lamps suitable for 70 watts, complete all as specified and as directed.
Supply & fixing in replacement Lamp electric srew type HPSV/MH lamps suitable for 150 watts, complete all as specified and as directed.
Supply & fixing in replacement Lamp electric srew type HPSV/MH lamps suitable for 250 watts, complete all as specified and as directed.
Supply & fixing in replacement Lamp LED 30 W GLO watt 230 volts pin type suitable for fix in batton holder, complete all as specified and as directed.
Supply & fixing in replacement Lamp holders suitable for pin type, complete all as specified and as directed.
Supply & fixing in replacement Ignitor 220-240 volts AC suitable for 70/150/250 watts HPMH/SV street light luminaries, complete all as specified and as directed.
Supply only 70/150/250 W HPSV/HPMH porcelain holder complete all as specified and directed
Supply & fixing in replacement Capacitor 220-240 volts AC suitable for 70/150/250 watts HPSV street light luminaries, complete all as specified and as directed.
Supply and Fixing in replacement of old burnt constant current driver suitable security light/flood light fitting of 25 to 60W capacity, complete all as specified and directed by Eng in Charge
Supply and Fixing in replacement of old burnt constant current driver suitable security light/flood light fitting of 72 to 100 W capacity, complete all as specified and directed by Eng in Charge
Supply and Fixing in replacement of old burnt constant current driver suitable security light/flood light fitting of 120 to 180 W capacity, complete all as specified and directed by Eng in Charge
Supply and Fixing in replacement of unsv burnt surge protection device of capacity 10 kv complete suitable for security light fitting of any capacity, complete all as specified and directed by Eng in Charge
Supply and fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street light based on LUX level of nature light having ON ≤ 30 lux and OFF ≥ 10 Lux . The sensor (Nature Switch) along with suitable power contactor , MCB and support termianl should be enclosure made of rust proof, electric shock proof , termite proof and FR grade SMC junction box(sintex make) conforming to confirmining IS 13947.4-1 & IS 8828, IP 66 including contactors ( 3 Nos each) and incoming- ourgoing MCBs ( 3 Nos each) rating of 25-40 amp and Circuit copper wiring of min 10 Sqmm cable including down old unserviceable, complete all as specified and directed.
S&F of 90 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 9900 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters .side entry mounted for 40 mm and above OD pipe bracket etc incl taking down old unsv light fittings complete all as specified and directed by Engr in- Charge .
S&F of 60 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 6600 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters .side entry mounted for 40 mm and above OD pipe bracket etc incl taking down old unsv light fittings complete all as specified and directed by Engr in Charge .
S&F of 120W LED Flood Light luminaire made up of Matt black ptextured powder coated pressure Die Cast aluminum housing and frame with heat resistant toughened clear glass fixed with SS screw/ Ant dust exposed lens, sturdiness and embossed brand name/ logo name of manufacturer on fixture . The luminaire should have a minimum system lumen output of 14400 lumens and 120 Watts. The fixture shall have a CRI of minimum 70. The fixture shall be designed for a sysytem life of 50000 hours @ 70 % lumen maintenence , Ingress protection of IP 66 (lamp and gear compartment ) and Mechanical impact resistance ratinfg of IK>=07. The fixture driver should have an operating voltage range of 120-277V, surge protection of internal 4 KV amd external surge protection of 10 KV, PF.0.95, THD<10%. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india .LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters including complete electrical connection with fixing arrangenment on pole or wall and taking down unsv light fittings complete all as specified and directed by Engr-in-Charge .
S&F IP65 rated 40 W LED post top light fitting with moonlight effects and efficient light distribution complete with electrical connection arrangement complete all as specified and directed
S & F junction box made of SMC/FRP sheet ready made of size 300 mm x200 mm x 105 mm having 100A capacity RYB and neutral aluminium bus bar of 3 mm thick duly fitted on suitable insulator and MCB SP 6A 10 KA 240V-01 with fixing arrangement fixed properly to pole/fixed on wall with MS clamps 25x5mm and nut and bolts, complete all as specified and directed.
Supply & Fix street light brackets fabricated out of medium grade GI pipe of 50 mm dia, 1.5mtr long bent to shape suitable for street light fittings with two sets of clamps made out of mild steel flat iron suitable for fixing on HT/LT poles with nuts, bolts and washers all as directed including dismantling the existing brackets etc complete all as directed.
S & F in repair MCB TPN 16-32 Amp 415 volts 50 Hz AC 10 KA "C" Series complete all as specified and directed.
S & F in repair MCB SPN 6-32 Amp 415 volts 50 Hz AC 10 KA "C" Series complete all as specified and directed.
S & F in repair MCB SP 6-32 Amp 415 volts 50 Hz AC 10 KA "C" Series complete all as specified and directed.
S & F XLPE cable, insulated,armoured, heavy duty electric cable with aluminium conductor,1100 volts grade, cross-sectional area 35 Sqmm 3.5 core including taking down old unservicebale cable, complete all as specified and directed . (Note : Excavation, returning and removal shall be measured and paid separately).
All as per item No.27.00 here-in-before but 25 Sqmm 4 core.
All as per item No.27.00 here-in-before but 16 Sqmm 4 core.
All as per item No.27.00 here-in-before but 10 Sqmm 4 core.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes cable & electric pole, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out any type of soil, complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3 m in depth for foundation, etc or not exceeding 10 Sqmm on plan and exceeding 1.5 m but not exceeding 3 m in depth for shafts, cesspits, manholes, pier holes, cable and electric pole etc and getting out in any type of soil complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25cm complete in any type of soil,complete all as specified and directed by Engineer-in-Charge.
Removing excavated material to a distance n.ext 50mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point.
M & L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base on floors, foundation filling and mass concreate, complete all as specified and directed.
M & L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filing and and mass concreate, complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping/above ground level around the pole etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form form work, complete all as specified and directed.
Sand (Dry clean ) as in cushioning to underground electric cable provided all as specified in Clause 19.75 of SSR Part-I 2009.
Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat all as directed.
Dismnalting of concrete poles/struts, any size and removing the same from site out side of MoD land, complete all as specified and directed. (Note : The item are not reuse in site and carrying to credit).
Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters) with 300 mm x 300 mm x 6 mm mild steel base plate continuously welded to poles, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection ,complete all as specified and directed by the Engr-in-Charge.
M & L for aluminium conductor, steel reinforced of any size on LT poles including straining, binding with insulators with AI/copper binding wire with insulators as in over head conductors, providing PVC sleeves for jumber fixed as in repairs, complete all as specified and directed.
Service cable/wire 1100 V twin core aluminium stranded conductor of size 6 Sqmm including taking down from street light poles any positions, complete all as specified and directed.
Service cable/wire 1100 V twin core aluminium stranded conductor of size 10 Sqmm including taking down from street light poles any positions, complete all as specified and directed.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of Rs. 80,790.00 during AOC Note:- Tenderers shall not quote for this Schedule
ASHOKA ENGINEERS AND BUILDERS
Surya & Gautam Builders
proach associates
Tawi Constructions
Prakash Trading Corporation
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .