Tender Value
₹26.6 L
EMD Value
₹53,200
Closing Date
29 Oct 2022, 6:00 pmClosed
GE SOUTH AKHNOOR
GE SOUTH AKHNOOR C/O 56APO
SPECIAL REPAIR OF PUMP HOUSE NO-9 OF GE (S) AKHNOOR AND SPL REPAIR TO BLD NO P-43, SINGLE OFFRS ACCN UNDER AOR OF AGE B/R-I UNDER GE (SOUTH) AKHNOOR.
2022_MES_555865_1
GES/AKH-44/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH AKHNOOR
MES EN-LISTED CONTRACTOR WITH CLASS D AND ABOVE WITH CATEGORY a(i)
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹53,200
28 Nov 2022
3 Oct 2022
1 Nov 2022
3 Oct 2022
29 Oct 2022
17 Oct 2022
Amount
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-In-Charge.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified and as directed by Engineer-In-Charge.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified and as directed by Engineer-In-Charge.
Taking down shutters of any descriptions area exceeding 1.00 Sqm but not exceeding 2.00 Sqm, complete all as specified and directed by Engineer-In-Charge.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-In-Charge.
Mild steel square bar framed work such as in grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; frame work of water tanks and similar work conforming to Fe-290, Gde-E-165, including cutting and welding, complete all as specified and as directed by Engineer-In-Charge.
Solid PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specification and drawing, including making good to disturbed surface of walls, complete all as specified and as directed by Engineer-In-Charge.
Anodised aluminium powder coated (minimum thickness of powder coating 50micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and as directed by Engineer-In-Charge.
Anodised aluminium powder coated (minimum thickness of powder coating 50micron) ventilator/ window shutters, aluminium section weighing 0.55 Kg/mtr including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc and fixing 5.50mm thick plain glass sheet and 5.0mm figured glass with rubber packing/ beading including Anodised aluminium powder coated grills of any size, pattern and aluminium wire cloth of nominal dia of 0.45mm and average width of aperature 1.40mm fixed with alumium wire and staples as directed, complete all as specified and as directed by Engineer-In-Charge. Note : Cost of 5.5mm thick plain sheet Glass and 5.0mm thick figured glass and other filling material in panels shall also be deemed to be included in quoted rate and nothing extra shall be admissible on this account.
Repair to RCC projection chajjas , roof fascias etc by scraping , cutting, chiseling , de-rusting and cleaning of exposed reinforcement surfaces, losse RCC surface with cement concrete in M-20(1:1.5:3), type A-1, (using 12.50mm graded crushed stone aggregate), nominal mix and reinforcement with welded mesh had drawn steel wire fabric of weight exc 2.0Kg/Sqm but not exc 4.0Kg/Sqm cut to length and shape required and tie with and including mild steel wire (annealed) not less than 0.9mm in dia as required, with or without fascia and finished with cement mortar15-20mm thick in 1:3 in patches area not exc 5.0 Sqm and thickness of RCC members n exc 70mm incl necessary form work and applying two coats of finishes to match with the existing surfaces at any height , complete all as specified and as directed by Engineer-In-Charge. Note : 1.0 Cost of steel wire fabric/expanded metal of required weight and size as directed shall deem to have been included in the quoted rates. 2. Cost of necessary saftey arrangements like ladders, saftey harness, scaffolding shall also be deemed to have been included in the quoted rates.
Dismantling of old/ damaged existing roof treatment with concrete and cleaning all waste and dirt by wire mesh, picking, sweeping and washing down with water to remove dust, etc, and removal of all material out side the cantt area and Applying one coat of neat cement slurry with 3.0 Kg of cement per Sqm on cleaned surfaces of roof, evenly, and screed bed/rendering 10mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement) including Water proofing treatment on roof top with APP (Ataxic Poly Propylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density polyethylene film, minimum weight not less than 3.0 Kg/ Sqm, 2.0mm thick, centre core is sandwiched on both sides by high quality polymeric mix with properties of high softening point, high heat resistance and cold resistivity to make it ideal for all water proofing treatment, with polymeric mix protection on both sides with 20 micron HMHDPE film, laid over one coat of bituminous primer conforming to IS: 3384, applied @0.40 Kg/ Sqm and one coat of hot blown bitumen of 85/25 grade, conforming to IS:702, applied @1.20Kg/ Sqm on prepared surfaces of roof, overlap should be not less than 150mm at ends and 75mm at sides, joints and overlaps uniformly bounded with LPG torch flame including applying of one coat of semi hot blown bitumen of 85/25 grade, @1.20 Kg Sqm and fine screened sand in dry condition @0.50 Kg/ Sqm after laying the membrane and including Precast machine pressed factory made PCC tiles, size 300x300mm and 20mm thick, with grey cement and no pigment, pointed in cement mortar 1:3 and laid over and including 15mm thick bedding layer in cement mortar 1:4 mixed with creosote oil @5% by weight of cement, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing chemical shall be included in quote rate.
Dismantling of old/ damaged existing roof treatment with concrete and cleaning all waste and dirt by wire mesh, picking, sweeping and washing down with water to remove dust, etc, and removal of all material out side the cantt area and Applying one coat of neat cement slurry with 3.0 Kg of cement per Sqm on cleaned surfaces of roof, evenly, and screed bed/rendering 10mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement) including Water proofing treatment on roof top with APP (Ataxic Poly Propylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density polyethylene film, minimum weight not less than 3.0 Kg/ Sqm, 2.0mm thick, centre core is sandwiched on both sides by high quality polymeric mix with properties of high softening point, high heat resistance and cold resistivity to make it ideal for all water proofing treatment, with polymeric mix protection on both sides with 20 micron HMHDPE film, laid over one coat of bituminous primer conforming to IS: 3384, applied @0.40 Kg/ Sqm and one coat of hot blown bitumen of 85/25 grade, conforming to IS:702, applied @1.20Kg/ Sqm on prepared surfaces of roof, overlap should be not less than 150mm at ends and 75mm at sides, joints and overlaps uniformly bounded with LPG torch flame including applying of one coat of semi hot blown bitumen of 85/25 grade, @1.20 Kg Sqm and fine screened sand in dry condition @0.50 Kg/ Sqm after laying the membrane and applying two coats of aluminium paint, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing chemical shall be included in quote rate.
Taking up or down steel tubing of 15mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed by Engineer-In-Charge.
Tubes, 'medium grade' galvanised, 15mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates.
Refixing old steel tubing galvanised, 15mm bore, with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts and connections in new or old position (walls, ceiling, floors, etc.), complete all as specified and as directed by Engineer-In-Charge.
Taking up or down steel tubing of 20mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed by Engineer-In-Charge.
Tubes, 'medium grade' galvanised, 20mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates.
Refixing old steel tubing galvanised, 20mm bore, with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts and connections in new or old position (walls, ceiling, floors, etc.), complete all as specified and as directed by Engineer-In-Charge.
Bib taps, long body, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.
Centre hole basin mixture,2 in 1 built in chromium plated, with round sport without pop up waste system for 15mm bore pipe,, fixing in repairs, complete all as specified and as directed.
Wall mixer with bend pipe for overhead shower with built-in non return valve, for hot and cold water, chromium plated, for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Cat Part No-F1014402 of Cera/ Jaquar/ Parko/ Hindware.
Centre hole basin mixture for hot and cold water, chromium plated, with round sport without pop up waste system for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Cat Part No-F1013451 of Cera/ Jaquar/ Parko/ Hindware.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, omplete all as specified and directed.
Excavation in trenches n exc 1.5 metre wide & n. exc 1.5 metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc n. exc 10 Sqm on plan n. exc 1.5 metre in depth and getting out in any type of soil, complete all as specified.
Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-35 Grade, laid over and including 30mm thick well rammed sand cushion laid over and including sub base of 75mm thick of plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), with grey cement and no pigment laid over and including Hard core of broken stone boulders of gauge n exc 63 mm, deposited spread and leveled in layers n exc 15 cm thick, complete all as specified and as directed by Engineer-In-Charge. Note :Thickness shall not exceed from 100mm thick.
Chequered cement concrete pre-laminated coloured tiles size 300mmx300mmx20/25mm thick, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 20mm thick screed bed or bedding layer in cement mortar 1:6 laid over and including 75mm thick sub base of Nominal Mix PCC 1:5:10 type E-2 using 40mm graded crushed stone aggregate, complete all as specified and as directed by Engineer-In-Charge.
M&L Cement concrete M-15, type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating and necessary form work, all as specified.
S&F Harrison rails 20mm dia , mild steel, chromium plated with fixing brackets, stops, rollers etc, complete all as specified and directed.
Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), ncluding cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
Non-skid, coloured, ceramic tiles (Designer Pattern) 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Non-skid, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 laid over and inlcuding Plain cement concrete Nominal Mix (1:2:4) M-15, type B-0 (using 12.50mm graded crushed stone aggregate), nominal mix, 25mm thick, complete all as specified and as directed by Engineer-In-Charge.
Vitrified Ceramic tiles 10mm thick (square/ rectangular) polished, non-skid, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 laid over and inlcuding Plain cement concrete Nominal Mix (1:2:4) M-15, type B-0 (using 12.50mm graded crushed stone aggregate), nominal mix, 25mm thick, complete all as specified and as directed by Engineer-In-Charge.
Vitrified Ceramic tiles 10mm thick (square/ rectangular) polished, non-skid, area of each tiles not exceeding 0.36 Sqm , set and fixing in skirting/ dado or any other vertical surfaces and pointed in white or coloured cement to match and including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed.
Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), 50mm thick, as in plinth protection and providing the joints throughout the thickness, filled with mastic filling comprising bitumen 85/25 grade and sand mixture 1:3 by weight, complete all as specified and as directed by Engineer-In-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-In-Charge.
Glazed ceramic tiles in vertical surface/ dado, size 300x450x7mm thick, 400x400x6/7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/ colour of tiles including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., complete all as specified and as directed by Engineer-In-Charge.
Granite (of any type) work (table rubbed and polished), 15-18mm thick, as in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed by Engineer-In-Charge.
Supply, fixing, jointing and testing, ISI Marked, of approved quality, gun metal globe/gate valve 20mm dia with iron wheel head, both ends screwed for iron pipe including taking down of old one complete all as specified and directed for following bore of pipes.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 125x60mm, complete all as specified and as directed by Engineer-In-Charge.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 105x60mm, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-1, (using 20mm graded crushed stone aggregate), nominal mix, as in cills, steps; plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates and in hold fasts or filling in hollow of steel frame, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Flush shutters, thickness 40mm, solid core construction, with block board core and plywood face panels, commercial type on both sides, having external teak wood lipping, 6mm thick fixed with nails, complete all as specified and as directed.
Factory made solid panel PVC door shutter with wood free EPS, 30mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame with three Nos of stainless butt hinges of 100mm size and rust proof screws, at site as per specification and drawing, complete all as specified and as directed by Engineer-In-Charge.
Supply and fixing in repair of cup board shutter 20mm thick (style) factory made PVC incl chowkat frame made out of MS tubes of 19 guage for top and bottom rails M S frame shall be covered with heated molded designer colour PVC channel having PVC sheet strip of 10 MM width stuck inside with solvent cement for styles and plane colour PVC sheets of top rail, lock rail and bottom rail on either side 10 mm (5 mm x 2) thick of 20 mm and 20 mm cross PVC sheets and as gap inserted for top and bottom rail. Paneling for plain colour PVC sheets to be fitted in the MS frame welded /sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement in the frame at site as per drawing held with AGE B/R-I and to the entire specifications. , complete all as specified and as directed by Engineer-In-Charge.
Sheet glass shelf assembly, consisting 5.50mm thick sheet glass, 120mm wide including anti rust screws, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Stainlees steel grating, chromium plated, size 125mm, heavy duty, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Angle valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, fixed in repairs, complete all as specified and as directed.
Factory made, plain framed, paneled shutter (two panel) 35mm thick, 2nd class hardwood with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and as directed by Engineer-In-Charge.
Glazed and skeleton shutters in second class hardwood, 35mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats including 0.56mm nominal dia of wire cloth with average width of aperature 1.18mm fitted with staples etc, complete all as specified and as directed.
Butt hinges, size 100mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed by Engineer-In-Charge.
Aluminium anodised, barrel tower bolts of extruded Section, size 150mm long and fixed, complete all as specified and as directed by Engineer-In-Charge.
Mild steel spring for doors, 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-In-Charge.
Aluminium alloy, anodised, sliding door bolt, size 250mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed.
Aluminium handles, cast type, anodised, size 150mm, complete all as specified and as directed by Engineer-In-Charge.
Cast iron body Door closer hydraulically regulated, designation No-3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Mild steel sliding door bolts, size 250mm long, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and as directed by Engineer-In-Charge.
Mild steel barrel tower bolts, size 150mm, stove enamelled black, with bright bolt and fixed, complete all as specified and as directed by Engineer-In-Charge.
Mild steel pressed handles, size 150mm, oval type, stove enamelled black, complete all as specified and as directed by Engineer-In-Charge.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, cverall length of cover plate 150mm, fixed in floor, complete all as specified and as directed.
Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed.
M&L for preparation of old painted steel surfaces of any description not other wise described over 10cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
Preparation of old/ decorated plastered or unplastered surfaces of walls and applying two coats of cement paint, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:6, complete all as specified.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed.
Rendering 15mm thick on bricks or concrete masonry surfaces, on walls, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed.
Rendering 5mm thick on any type of surfaces, on ceiling, in cement mortar 1:3, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement), complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing compound shall deemed included in quoted rates.
RS&F in replacement of otational moulded polyethylene water storage tanks of 1000 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Rotational moulded polyethylene water storage tanks of 500 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Demolition and breaking up drain pipes (Salt glazed ware, CI,AC or Reinforced concrete) of 100mm internal dia, set in cement mortar, complete all as specified and as directed by Engineer-In-Charge.
Demolition and breaking up drain pipes (Salt glazed ware, CI,AC or Reinforced concrete) of 75mm internal dia, set in cement mortar, complete all as specified and as directed by Engineer-In-Charge.
Cast iron sand cast soil, waste and vent pipes, 100mm bore, in any length with or without ears, with cement joints, laid in trenches or in floors, complete all as specified and directed by Engineer-In-Charge.
Cast iron sand cast soil, waste and vent pipes, 75mm bore, in any length with or without ears, with cement joints, laid in trenches or in floors, complete all as specified and directed by Engineer-In-Charge.
Cast iron bends, 100mm bore pipe (any radius), with duck's foot or heel rest, complete all as specified and as directed by Engineer-In-Charge.
Cast iron bends, 75mm bore pipe (any radius), with duck's foot or heel rest, complete all as specified and as directed by Engineer-In-Charge.
PVC waste pipe, 32mm bore with cup washers, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Cast iron ‘P’ or ‘S’ trap, with grating of 100mm outlet dia including jointing to waste pipe fixed in plain cement concrete, M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.
Cast iron floor trap, with grating of 100mm outlet dia including jointing to waste pipe fixed in plain cement concrete, M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.
Salt-glazed stoneware gully traps, size 150x100mm, square or round mouthed, type 'P' including jointing to waste pipe fixed in plain cement concrete, M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) , complete all as specified and as directed by Engineer-In-Charge.
Preparation of newly plastered or unplastered surfaces of walls and applying two coats of acrylic smooth exterior paint of required shade @ 1.67KG/10SQM including exterior primer @ 2.20Kg/10SQM, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whiting, on plastered surfaces, preparatory to distempering, complete all as specified and as directed.
Preparation of new plastered or unplastered surfaces of ceiling and applying two coats of distemper oil emulsion over one coat of chalk whiting, on plastered surfaces, preparatory to distempering, complete all as specified and as directed.
Salt-glazed stoneware drain pipes, internal 150mm, laid in trenches and jointed in cement mortar 1:1 including Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) of 150mm internal dia, set in cement mortar incl taking down old one of any specification,, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-2 (using 40mm crushed stone aggregates) as in bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; after laying, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) pipes, 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, single socketed, in any length with rubber ring joints, fixed on wall with mild steel/ PVC clamps, fixing in repairs, complete all as specified and as directed.
PVC (SWR) bends of 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, any radius, fixing with adhesive, complete all as specified and as directed.
Demolition of cement concrete (reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
PVC connections 15mm size with brass nuts of length 450mm, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China wash down water closet pan (pedestal pattern), white (including fixing bolts, flush pipe but excluding flushing cistern) and including plastic water closet seat cover, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and making good to dismantled/ damaged floor in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.
Vitreous China wash basin (full pedestal type), size 605x500 mm, white, design and accessories as per cat part and making good to dismantled/ damaged wall in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Design- Camber (Cat part No- S2040154 for wash basin and S2090125 for full pedestal) of Cera or equivalent in Johnson/ Hindware/ Jaquar.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white washing, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China wash hand basin, white, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper including brackets of any size, including cutting for and pinning in ends of brackets or erecting stand including fixing and supply of waste pipe of 32mm dia and waste coupling, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, capacity 10.0 litres and making good to dismantled/ damaged surfaces, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Brass chromium plated, tubular towel rail, 20mm dia, D type, 60cm long between flanges, fancy type, complete all as specified and as directed by Engineer-In-Charge.
Precast reinforced cement concrete M-20(1:1.5:3), type A-1, (using 20mm graded crushed stone aggregate), nominal mix, as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs and similar articles with plain faces as specified in clause No- 4.11.16 of SSR Part-I (2009), set in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge. Note : The descrption shall also deemed to have included the cost of TMT bars of 10mm dia and over all as per codal provisions as conforming to IS 456:2000 and necessary form work.
Cleaning of blocked/ choked SGSW/ Cast Iron drain pipes/ sewer lines of any dia and any types, in horizontal or vertical position by rodding, from manholes to manholes and manholes end to septic tanks/ soakage wells, flushing with pressure jet of water/ sewage suction machine after taking out existing manholes covers and putting back manhole covers in original position after cleaning of lines including removing the sludge and other waste materials/ blockage in drain pipes, transport to outside of Unit/ Cantonment area and spreading bleaching powder on top of manholes covers of septic/ soakage pits or in the surrounding areas to make hygienically fit, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of transportation of waste materials shall be deemed included in quoted rates.
Removing of manholes covers (any type) and dewatering/ pumping/ bailing out of contaminated water including cleaning of sludge and night soil from septic tanks/ soakage wells of any capacity and depth alongwith inlet/ outlet chambers etc by vehicle mounted sewage suction machine including pumping out the contaminated water in open drain/ low lying area to a distance exceeding 50mtr and removing the sludge, silt etc. (solid waste materials) to outside of Unit/ Cantonment area and putting back manhole covers in original position including spreading bleaching powder on top of septic tanks/ soakage wells to make it hygienically fit, complete all as specified and as directed by Engineer-In-Charge. Note: (i) Actual quantity of sludge/ waste material only shall be measured after dewatering the septic tanks only, the sludge shall be carried away in the sewage carrying tankers, of minimum capacity 7000 Ltrs each. (ii) Cost of dewatering/ pumping out of contaminated water from septic tanks and soakage shall deemed be included in quoted rates.
Machine cut kota stone slab, (minimum size shall be 550x550mm), flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or bedding layer of mortar 20mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Machine cut kota stone slab, (size shall in one length), 12mm thick, as in riser of steps, skirting, dado and pillar, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or back plastering layer of mortar 15mm thick in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Factory made steel window, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter with wire mesh and plain sheet glass 3.0mm thick, 4mm thick frosted glass, jointed internally and made with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD-1304, sheet No- 1/3 to 3/3 and as directed by Engineer-In-Charge. Note :- Cost of window shall include all members and spare parts as elaborated in the Drwaing and in the specifications and nothing shall be paid extra seperately.
Brass chromium plated shower rose 125mm size, fancy type, fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Construction of soakage well of 1.8 mtrs dia and 3.0 mtrs in depth, in any type of soil including plain cement concrete M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregates) in foundation and honeycombed brick masonry in cement mortar 1:4 and reinforced cement concrete cover slab, M-25, type A-1 (using 20mm graded crushed stone aggregates), complete all as specified and as shown in drawing. Drawing No- CE/TD/1202/03 sheet 1/2 and 2/2 dated 09.10.03 revised 14.10.14 and 11.05.07.
Ball valves, PTMT, PVC, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge.
Point wiring for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Description all as serial item No- 114.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 114.00 here in before but for one 3-pin socket outlet 5-Amps on the independent board.
Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheeathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination 2-in-1, 3-pin, 5 Amp flush type universal type, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination 2-in-1, 3-pin, 5 and 15 Amp flush type universal type, complete all as specified and as directed by Engineer-In-Charge.
T bulb curve, 12 Watt LED base B22 cool day light, complete all as specified and as directed by Engineer-In-Charge.
Stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-In-Charge.
Point wiring (in new concealed conduits to surfaces), modular type for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including modular boxes, modular cover plates of module and colour as directed and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of modular boxes, modular cover plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate.
Description all as serial item No- 125.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 125.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board.
Point wiring (in new concealed conduits to surfaces), modular type, for 3/6-pin, 15 Amps, socket outlet on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including modular boxes, modular cover plates of module and colour as directed and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of modular boxes, modular cover plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate.
Modular switch piano, single pole, one way, 5/10 Amps, 1/2 module complete all as specified and as directed by Engineer-In-Charge.
Modular switch 1 way 16A, 1/2 module 240 Volts, complete all as specified and directed by Engineer-In-Charge.
Modular stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
Modular bell push switch, single pole, one way, 5-Amps, 1/2 module, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
Shuttered Socket outlet modular type, 6A -5 pin combined 2 module, 240 Volts, complete all as specified and directed by Engineer-In-Charge.
Shuttered Socket outlet modular type, 6/16A -6 pin combined 2 module, 240 Volts, complete all as specified and directed by Engineer-In-Charge.
Modular LED indicator lamp fixed on modular switch board 240V, AC, 50Hz suitable for 1/2 Module ISI marked incl connecting with suiatble legnth of 1.50 sqmm PVC insulated copper wire, complete all as specified and as directed by Engineer-In-Charge.
S & F Inverter LED Batten with opal diffuser, IP20, battery back-up & functioning as per product TDS, 20 Watt, complete with all accessories with twin core twisted flexible copper conductor cable with suitable size all as specified and directed. Havells cat part No- PRIDE PLUS INVERTER BATTEN LHEXACP7FN1W020 or Equivalent Makes in Crompton/Philips/Osram.
S&F in replacement of 4 feet highly engineered plastic body suitable with fully diffused diffuser for general lighting in areas. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2000 nominal lumens and an outstanding solution efficacy of atleast 100 lumen/watt and maximum system wattage of 20 Watts. The electronic driver used shall have a power factor >0.95 and THD <20% with 4 KV internal surge protection. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make : Bajaj cat part No BCLSB 20 WH Bajaj or Equivalent makes in Wipro/Philips. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
LED tube light fitting, 10 watt, retrofit, 2-feet long, indoor decorative aluminium extruded LED battens, including LED lamp 10 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- Lumi Line Plus BS10WLED865SPCSS or equivalent in Crompton/Philips/Bajaj.
Decorative, wall light fixture made up of Polycarbonate, suitable for 9 W retrofit LED lamp B22 base., including LED lamp of 9 Watt, complete all as specified and as directed by Engineer-In-Charge. Make: Havells ordering cat part No-LHDL02160099 or equivalent in Bajaj/ Philips/ Wipro/ Crompton.
Replacement of old unserviceable/ damaged Industrial Bulkhead luminaire environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of high brightness LED 10 Watt and fixing matrials such as clamps, nuts, bolts, washers etc completed including taking down old unserviceable fittings, complete all as specified and as directed by Engineer-In-Charge. Make: Havells Cat Part No- HEXAFT10WLED857SSYMBOPC or equivalent in Crompton/Philips/Bajaj.
Sub main wiring (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
Sub main wiring (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 6 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-40)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Door bell, AC, 230 Volts, single pole, ding-dong type sound, completeall specified and as directed by Engineer-In-charge.
S&F in replacement of Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of Sheet metal enclosures with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 40 Amps, 240 Volts, complete all as specified and as directed.
S&F in replacement of MCB, Single Pole and Neutral, 32 Amps (up to), 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of MCB, Triple Pole and Neutral, 63 Amps (up to), 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Supply, laying commissioning, testing of the XLPE LT cable 1100 volts grade of size 16 Sqmm 2 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches/fixing on wall in PVC conduit pipe with the help of clamp/shadels, under road crossing through protection pipe etc after taking out existing under ground cable complete all as specified and directed.
Replacement of old unserviceable/ damaged Cable and Supply, laying commissioning, testing of the XLPE LT cable 1100 volts grade of size 25 Sqmm 4 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches/fixing on wall in PVC conduit pipe with the help of clamp/shadels, under road crossing through protection pipe etc after taking out existing under ground cable complete all as specified and directed.
S&F in replacement of SITC of high-quality integrated LED Street Light with a minimum system lumen of 4950 Lm and system wattage not exceeding 45W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF > 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have 4KV internal 10KV external surge protection in the Luminaire.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified, complete all as specified. Make : Bajaj cat part No ENXT P 54L WH PO PC SD or Equivalent makes in Wipro/Philips. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
S&F in replacement of Ceiling fan, mettalic, sweep 1200mm, with BLDC Motor, high speed, inclduing necessary fitting/fixtures such as Hook and clamps etc including connectig wire of suitable size and length from ceiling rose to fan connector, having BEE Star Rating- 5 Star, Rated Power Input in Watt 28±10%, Rated Speed in RPM 345±10%, Rated Air Delivery in CuM/ Min- 220 Minimum, Service Value CMM/W 7.85 Minimum No of Speed 5 , Insulation Class- E, Temperature Rise @ Rated Voltage 25 degree Celcius (Max) by winding resistance measurement at an ambient 30 degree Celcius, High Voltage Test Withstands 1.5KV, Insulation resistance Above 2 MΏ, Type of Ball Bearings Single row deep groove ball bearings of 6202 sizes Top & Bottom Cover should be of aluminium, Type of Lubricant Used Lithium Based – Shell Alvania RL3, Material of Blade Aluminium, BEE Certification, Material of Canopies- Polypropylene, complete all as specified and as directed. Make: BAJAJ Model No Energos 28 or Equivalent Makes in Havells / Crompton Greaves/ Usha / Orient Electric energy star Note: Old Ceiling fan taken out from the existing opening and shall be deposited at Store Yard of MES and shall be the property of Deptt.”
S&F in replacement of Ventilair fan, Plastic Body , sweep 250mm with louver shutter, superior rating for energy saving, copper wounded motor , Electrically operated automated front shutter Modern design, fashionable & elegant look and gravity Shutter To prevent entry of foreign objects like dust, bird, pets etc complete with nut bolts, washers incl making necessary connection with suitable size and length of wire of copper condutor, complete all as specified and as directed by Engineer-In-Charge. Make: Havells/ Crompton Greaves/ Usha/ Bajaj/ Orient. Note: Old Exhaust /Ventilair fan taken out from the existing opening and shall be deposited at Store Yard of MES and shall be the property of Deptt..
S&F in replacement of Sheet metal enclosures for Triple Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 4-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
Amount of Schedule of credit of for Rs 67,679.00 shall be deducted from quoted amount.
CHOPRA CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .