Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.8 LAccepted-Finance | ₹47.8 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹49.4 L+₹1.6 L (3.43%)Rejected-Finance SUMEL BAMANWAS SWAI MADHOPUR | ₹49.4 L+₹1.6 L (3.43%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹49.5 L+₹1.8 L (3.69%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | ₹49.5 L+₹1.8 L (3.69%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹49.7 L+₹1.9 L (3.96%)Rejected-Finance | ₹49.7 L+₹1.9 L (3.96%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹50.1 L+₹2.3 L (4.89%)Rejected-Finance | ₹50.1 L+₹2.3 L (4.89%) | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | V R TRADERS L3 | GS and Co L2 | SHIV SHAKTI BUILDERS L5 | GILL ENTERPRISES L1 | RAJINDRA AIR CONDITINOR FABRICATORS L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down point wiring complete including fixture and fittings and making good to disturbed area all as specified and directed by Engineer-in-Charge. | 1,442 | Per point | 20 ₹28,840 | 14 ₹20,188 | 10 ₹14,420 | 29 ₹41,818 | 5 ₹7,210 Lowest |
| 2.00 | Taking down submain wiring 2 run / 4 run with earthing cable and making good to disturbed area all as specified and directed by Engineer-in-Charge. | 2,059 | RM | 10 ₹20,590 | 15 ₹30,885 | 10 ₹20,590 | 10 ₹20,590 | 5 ₹10,295 Lowest |
| 3.00 | M&L in replacement point wiring complete with ISI marked 1.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through concealed in wall/ceiling with PVC rigid concealed conduit suitable size with all accessories such as bend, reducers, MS hooks, ceiling rose, galvanised steel pressed modular terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc covered with 3 mm thick plastic laminated modular top cover sheet of required color fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer including fixing and 1.5 sqmm copper conductor as earth continuity to connect common earth dolly and including taking down old unserviceable wire any type and making good disturbed surfaces of walls as necessary completed for One light point/ Fan point/ Exhaust point/ bell point controlled by one way switch all as specified and directed | 935 | Per Point | 500 ₹4,67,500 Lowest | 550 ₹5,14,250 | 580 ₹5,42,300 | 589 ₹5,50,715 | 550 ₹5,14,250 |
| 4.00 | All as per Srl item No. 3.00 here-in-before but one three pin socket out let 5 amps on the same board with other switches | 166 | Per Point | 500 ₹83,000 | 250 ₹41,500 | 300 ₹49,800 | 246 ₹40,836 Lowest | 270 ₹44,820 |
| 5.00 | All as per Srl item No. 3.00 here-in-before but One 3 pin, 5A switch socket outlet point on independent board | 169 | Per Point | 50 ₹8,450 Lowest | 550 ₹92,950 | 550 ₹92,950 | 344 ₹58,136 | 550 ₹92,950 |
| 6.00 | All as per Srl item No. 3.00 here-in-before but with 2.5 sqmm cable for 1No 16 amps socket outlet point on independent board including 2.5 sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor | 172 | Per Point | 550 ₹94,600 Lowest | 650 ₹1,11,800 | 700 ₹1,20,400 | 589 ₹1,01,308 | 650 ₹1,11,800 |
| 7.00 | S&F PVC Lamp holder suitable for LED 5 to 20 watt bulb and including taking down old unserviceable holder complete all as specified and directed | 150 | EACH | 35 ₹5,250 Lowest | 80 ₹12,000 | 90 ₹13,500 | 246 ₹36,900 | 70 ₹10,500 |
| 8.00 | M&L for ceiling rose 3 terminal / PVC / polycarbonate isolated body and including taking down old unserviceable ceiling rose all as specified and directed by Engineer-in-Charge | 160 | EACH | 25 ₹4,000 Lowest | 35 ₹5,600 | 40 ₹6,400 | 196 ₹31,360 | 47 ₹7,520 |
| 9.00 | S&F Bell ding dong AC 230V single pole and including taking down old unserviceable items complete all as specified and directed | 250 | Each | 150 ₹37,500 | 180 ₹45,000 | 149 ₹37,250 Lowest | 491 ₹1,22,750 | 160 ₹40,000 |
| 10.00 | S&F bell push flush type 5 amps and including taking down old unserviceable items complete all as specified and directed | 90 | Each | 20 ₹1,800 Lowest | 30 ₹2,700 | 25 ₹2,250 | 147 ₹13,230 | 20 ₹1,800 Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
17 Sept 2025, 6:00 pmClosed
GE FARIDKOT
GE FARIDKOT MIL STN
REPAIR REPLACEMENT OF INTERNAL ELECTRIFICATION AND INTERNAL POINT WIRING SUB MAIN WIRING FIXTURE EARTHINGS AND CONNECTED WORKS OF MD ACCN AND REPAIRS MAINT OF DIFFERENT TYPES OF WINTER APPLIANCES INCLUDING CONNECTED WORKS AT FARIDKOT MIL STN
2025_MES_727254_1
GE FRD-11/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE FARIDKOT
Class D b i
9 documents required · 9 mandatory
₹500
GE FARIDKOT
₹1 L
Yes
24 Sept 2025
22 Aug 2025
19 Sept 2025
22 Aug 2025
17 Sept 2025
5 Sept 2025
Amount
Taking down point wiring complete including fixture and fittings and making good to disturbed area all as specified and directed by Engineer-in-Charge.
Taking down submain wiring 2 run / 4 run with earthing cable and making good to disturbed area all as specified and directed by Engineer-in-Charge.
M&L in replacement point wiring complete with ISI marked 1.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through concealed in wall/ceiling with PVC rigid concealed conduit suitable size with all accessories such as bend, reducers, MS hooks, ceiling rose, galvanised steel pressed modular terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc covered with 3 mm thick plastic laminated modular top cover sheet of required color fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer including fixing and 1.5 sqmm copper conductor as earth continuity to connect common earth dolly and including taking down old unserviceable wire any type and making good disturbed surfaces of walls as necessary completed for One light point/ Fan point/ Exhaust point/ bell point controlled by one way switch all as specified and directed
All as per Srl item No. 3.00 here-in-before but one three pin socket out let 5 amps on the same board with other switches
All as per Srl item No. 3.00 here-in-before but One 3 pin, 5A switch socket outlet point on independent board
All as per Srl item No. 3.00 here-in-before but with 2.5 sqmm cable for 1No 16 amps socket outlet point on independent board including 2.5 sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor
S&F PVC Lamp holder suitable for LED 5 to 20 watt bulb and including taking down old unserviceable holder complete all as specified and directed
M&L for ceiling rose 3 terminal / PVC / polycarbonate isolated body and including taking down old unserviceable ceiling rose all as specified and directed by Engineer-in-Charge
S&F Bell ding dong AC 230V single pole and including taking down old unserviceable items complete all as specified and directed
S&F bell push flush type 5 amps and including taking down old unserviceable items complete all as specified and directed
S&F in replacement PVC wall plug / gatti of size 35 mm / 50 mm of suitable required size including taking down old unserviceable items complete all as specified and directed.
S&F in replacement T-Type catcher of suitable size for fixing of tube light in wall and including taking down old unserviceable items complete all as specified and directed
S&F in replacement catcher of suitable size for fixing of wire in wall and including taking down old unserviceable items complete all as specified and directed.
S&F in replacement of black screw 1 inch/ 1.5 inch/2 inch/3 inch long of suitable size as per requirement and including taking down old unserviceable items complete all as specified and directed.
S&F of Rechargeable LED tube light fitting 20W, (4 feet long) 230 V, surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver and including connections up with copper conductor wire with suitable size as per specification and directed by Engineer-in-Charge. Note:- LED tube light must be rechargeable and minimum 4 hours battery backup
S&F in replacement 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of size 6 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular and including taking down old unserviceable items complete all as specified and directed.
S&F in replacement 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of size 10 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular and including taking down old unserviceable items complete all as specified and directed.
S&F in replacement of Modular switch 1 way 16 amps 1 module including taking down unserviceable switch any type all as specified and directed
S&F in replacement of Modular socket 6A / 16A - 2/3 pin combined 2 module including taking down unserviceable socket any type all as specified and directed
S&F in replacement of Modular switch 1 way 6 amps one module including taking down unserviceable switch any type all as specified and directed
S&F in replacement of Modular socket 6A 2/3 pin combined 2 module including taking down unserviceable socket any type all as specified and directed
S&F piano type switch single pole 1 way 5/6 amps 230 volt AC supply and including taking down old unserviceable item complete all as specified and directed
S&F socket two in one 3/5 Pin 5 Amps 230 volt AC supply and including taking down old unserviceable item complete all as specified and directed
S&F piano type switch single pole 1 way 15/16 amps 230 volt AC supply and including taking down old unserviceable item complete all as specified and directed
S&F socket 15/16 Amps 230 volt AC supply and including taking down old unserviceable item complete all as specified and directed
Taking down and refixing of LED tube light fitting 20W/ 10W (4f/2ft long) 230 V, surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver and including connections up with copper conductor wire complete all as specified and directed
Supply and laying submain wiring with two single core PVC FRLS insulated copper conductor 6 sqmm and same 6 sqmm for continuous earth wire drawn in existing PVC conduit and including taking down old unserviceable wire any type and making good disturbed surfaces of wall all as specified and directed.
Taking down MCBs/MCCBs and refixing with necessary connections in DBs complete all as specified and directed .
Supply and laying rigid non-metallic PVC conduit size 20 mm/ casing capping exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. with all fitting including taking down old Unserviceable pipe any type complete all as specified and directed by Engineer-in-Charge.
M&L in replacement factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN DB) double door (IP-42 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates including one MCCB 100 Amp 4 pole 415V as incommer and 8 Nos outgoing MCBs 230V as rating required at site including flexible pipe complete all as specified and conforming to IS: 8623 including making good disturbed surface complete all as specified and directed. NOTE : All MCBs/MCCB and cables terminating into MCBs/MCCB shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under this item
M&L in replacement repair of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.2 mm thick CRCA sheet with metal double door (IP-42 protection ) fixed flush to wall and suitable for universal mounting and including 100 Amps bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with one MCB SPN 40 Amp as incomer and outgoings 6 Nos MCB as rating required at site including flexible pipe complete all as specified and conforming to IS: 8623 including making good disturbed surface all as specified and directed. NOTE : All MCBs and cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under this item
Supply and laying Rigid non-metallic PVC conduit size 25 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. with all fitting including taking down old unserviceable pipe any type complete all as specified and directed by Engineer-in-Charge.
M&L in replacement MS sunken box 1.6 mm thick galvanised steel pressed sunken terminal boxes as per existing size, painted on both sides inside and outside with one coat of red oxide primer of suitable sizes for mounting of switches sockets, fan regulators etc. with 3mm thick plastic laminated sheet covers per existing size and including taking down old unserviceable items, making good to the disturbed surfaces of walls, matching the colour with existing surface complete all as specified & directed
M&L for providing earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0 sqmm size upto 7.5 meter long by means of bolts, nuts check nuts and washers of all galvanised iron or steel all as shown in electrical plate No.5 of SSR Part-1 and connected to equipment including necessary excavation/ earth work in any type of soil/rock strata, funnel with wire mesh and 20mm dia pipe for protection of earth wire PCC pit with 40mm thick PCC cover etc. complete all as specified and directed
S&F in replacement of hylam sheet of size 5x8 Square inch with cutting slot for mounting of switches sockets, fan regulators including nut, washer thimble etc. with 3mm thick plastic laminated sheet cover of same size and making good to the disturbed surfaces of walls, matching the colour with existing surface complete all as specified & directed.
S&F in replacement of hylam sheet of size 9x11 Square inch with cutting slot for mounting of switches sockets, fan regulators including nut, washer thimble etc. with 3mm thick plastic laminated sheet cover of same size and making good to the disturbed surfaces of walls, matching the colour with existing surface complete all as specified & directed.
S&F in replacement of hylam sheet of size 11x13 Square inch with cutting slot for mounting of switches sockets, fan regulators including nut, washer thimble etc. with 3mm thick plastic laminated sheet cover of same size and making good to the disturbed surfaces of walls, matching the colour with existing surface complete all as specified & directed.
M&L for Cutting chases in bricks wall /PCC walls for taking out blocked concealed conduit and making good to surface in cement mortar 1:3 and with finish to match the existing surface complete all as specified and directed
Laying only for sub main wiring as 1 x single core PVC FRLS insulated copper multistranded 1.5/2.5/4.0/6.0 sqmm in existing rigid PVC conduit including connection with electrical appliances and taking down old unserviceable wire complete all as specified and directed
Fixing only switch/socket/fan regulator/ fan regulator at site all as specified and directed.
Fixing only of LED tube light fitting 20W/ 10W (4f/2ft long) 230 V, surface/ wall mounted LED batten with polycarbonate housing & integrated electronic driver and including connections up with copper conductor wire at site complete all as specified and directed
Fixing only ceiling fan of any size and taking down old unserviceable celling fan and deposit it to E/M store yard complete all as specified and directed
Fixing only exhaust fan/ fresh air fan of any size and taking down old unserviceable items complete all as specified and directed
S&F in replacement of condenser 3.15/2.5 Mfd AC 240V, including taking down unserviceable condenser any type all as specified and directed by Engineer-in-Charge
S&F in replacement of 2.5 Sqmm 3 core cable from top plug to geyser complete all as specified and directed by Engineer-in-Charge. NOTE: (A) The complaints are required to be attended/rectified on the same day of the reporting. However in exceptional case, if any complaint could not be attended on the same day. The same will be cleared within 48 hours of the reporting. (B) The contractor shall deposited the old material rete rived from item No 1 to 45 in MES store yard within 48 hours by his own arrangement to concerned JE E/M and shall maintain the record for the same.
M&L for checking/ inspection of non functional/ non working geyser any capacity/ make in existing location for identifying the defects/ faults in geyser/ wiring and solar water heater/ fault from DB etc all as per complaint obtained from MES service centre complete all as specified and directed. Notes :- (i) Attending day to day petty nature of complaints in repair and maintenance of solar water heater & electric water storage heater (geyser) of any type / capacity, lodged by the users including fault detection and rectification or making the same serviceable by providing skilled technician with helper and obtaining the signature from users and up keeping the record up to date complete in all respect and as directed. (ii) Contractor shall provide the complaint slip containing 100 pages in duplicate of size 5 inch x 8 inch properly binded and printed with their Firm Name and Telephone numbers as per sample complete all as specified and directed. (iii) The complaints should be attended within 12 hrs by deploying required Nos of manpower
S&F in replacement of gun metal check valve/ non return valve 15 mm dia suitable for Geyser of any make/ capacity complete all as specified and directed
S&F in replacement of pressure release valve for geyser 15 mm dia suitable for existing complete all as specified and directed
S&F in replacement of geyser triangle shape/ round/ cup shape/ banana type/ altro/ eterno type heating element 1500 watt suitable for any type, size & make of geyser as per existing including rubber ring clamping screws etc. complete all as specified and directed
S&F in replacement of geyser triangle shape/ round/ cup shape/ banana type/ altro/ eterno type heating element 2000 watt suitable for any type, size & make of geyser as per existing including rubber ring clamping screws etc. complete all as specified and directed
S&F in replacement of thermostat of geyser suitable for any type, size & make of geyser as per existing range 15-60 degree temperature complete all as specified and directed
S&F thermostate temperature auto cut out for geyser complete all as specified and directed
S&F in replacement of indicating lamp round type suitable for Geyser any type complete all as specified and directed
S&F in replacement of Heating plate assembly with water inlet & outlet, rubber gasket, nuts and bolts and washers of required size suitable for 50 Ltr Capacity Geyser of any type and make etc complete all as specified and directed
All as per Srl item No 54 here-in-before but suitable for capacity 25 Ltrs Geyser
S&F in replacement of glass wool for geyser vessel of any size and capacity complete all as specified and directed
S&F in replacement of mild steel holding/anchor bolts and nuts machine made of size 10cm to 15cm long and dia of bolt 10mm to 15mm complete including making good and matching existing disturbed surface and finish complete all as specified and directed by Engineer-in-Charge. Note :- Anchor bolt shall be grouted with hammer drill only
S&F in replacement of dead nut/ Safety plug of brass as per sample suitable for Geyser of any capacity/ make complete all as specified and directed by Engineer-in-Charge
S&F in replacement of socket out let (enclosure type) suitable for Geyser complete all as specified and directed by Engineer-in-Charge
S&F in replacement of metal plug top (enclosure type) suitable for geyser complete all as specified and directed by Engineer-in-Charge
S&F in replacement of hot water PVC connection of 15mm bore heavy duty, length upto 45cm with brass nut joints and washers at both ends complete all as specified and directed by Engineer-in-Charge
S&F in replacement of sheet metal enclosures with socket plug top and MCBs single pole and neutral enclosure with a 2 pin and earth plug and socket complete all as specified and directed
Fixing only MCB, SPN, 32 amps, 230V, C Series with breaking capacity 10 KA with connection complete all as specified and directed
Fixing and replacement of plug top 15/16Amps all as specified and directed by Engineer-in-charge Note item issued under such B free for fixing by the department
Fixing only Piano type switch single pole 1 way 15/16 amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
Fixing only socket two in one 5/6 Pin 15/16 Amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
M&L for replacement of bottom split inspection cover for geyser of capacity 25 ltrs of any make complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified including all fittings of size 16 mm dia (Note- Rates quoted shall deemed to be included for making holes/nitch for replacement of pipe and making good disturbed surface to match with existing surface and finish complete all as specified and directed by Engr-in-Charge
S&F in replacement of stop valves 15mm bore, cast copper alloy, high pressure, both ends screwed complete all as specified and directed by Engr-in-Charge
Fixing only stop valves 15mm bore, cast copper alloy, high pressure, both ends screwed complete all as specified and directed by Engr-in-charger. Note item issued under Sch B free for fixing by the department
S&F in replacement of Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for GI pipe or for brass ferrule and fixed complete all as specified and directed
Fixing only bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for GI pipe or for brass ferrule and fixed complete all as specified and directed.. Note item issued under Sch B free for fixing by the department
S&F in repair galvanised iron tubing, 15 mm bore, medium grade with fittings, fixed to walls and ceiling with hooks or laid on floor including taking down old unserviceable pipe complete all as specified and directed
S&F in repair GI Socket 15mm dia, ISI marked complete all as specified and directed.
S&F in repair GI Union 15mm dia, ISI marked complete all as specified and directed.
S&F in repair GI Elbow 15mm dia, ISI marked complete all as specified and directed.
S&F in repair GI Nipple 15mm dia ,100mm long ,ISI marked complete all as specified and directed.
S&F in repair GI Tee 15x15x15mm dia, ISI marked (Independently) complete all as specified and directed.
S&F in repair PVC insulated and FRLSH sheathed, circular, flexible, multi stranded, copper cable, 3 core of size 30/0.75 (2.5 sqmm) complete all as specified and directed
S&F in repair High quality evacuated/vacuum glass tube of outer dia 58 mm, internal dia of tube 47 mm in 1800 mm length, thickness of tube not less than 1.8 mm made from borosilicate to minimize heat loss with triple layer coating for maximum absorption of solar radiation including gasket & mounting screws nut etc suitable for solar water heater complete all as specified and directed by Engr-in-Charge.
S&F in repair Heating element 3.0 KW single phase, ISI marked suitable for Solar Water Heater complete all as specified and directed by Engr-in-Charge.
S&F Installation, testing and commissioning in replacement of Solar Hot Water Tank capacity 500 Ltr made of 1.2 mm SS 304 with 50mm PUF insulation, with provision electrical back up and other safety devices such as thermostat relay etc complete all as specified and directed by Engr-in-Charge. Make: TATA BP solar/Intersolar/ luminous/Novel
S&F Installation, testing and commissioning in replacement of Solar Hot Water Tank capacity 200 Ltr made of 1.2 mm SS 304 with 50mm PUF insulation with provision electrical back up and other safety devices such as thermostat relay etc complete all as specified and directed by Engr-in-Charge . Make TATA BP solar/Intersolar/ luminous/Novel
M&L for servicing of split type AC (hot & cold type)of capacity 1.5 / 2 TR of any type or make by opening the condenser unit fixed on roof top and heating unit fixed inside the building, and cleaning the complete condenser unit and heating unit including fins and checking / testing of all parts for its serviceability, and oiling / greasing of motors, replacing worn-out bushes of blower, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant gas upto the required level, replacement of minor parts such as nut / bolt washers etc. and reassembling of complete unit including testing for smooth functioning complete all as specified and directed
M&L for removing the unserviceable condenser fan motor from Split type A/C of 1.5 / 2.0 TR capacity, and fixing new condensing motor in original position with new washer nuts & bolts complete all as specified and directed
M&L for removing the unserviceable reciprocating compressor sealed unit of any type or make from split type air conditioner (hot & cold type) of capacity 1.5/2.0 TR after cutting the copper tubing without any damage to existing parts, replacing the compressor with reconditioned compressor of same make & capacity complete with erection of compressor on base with suitable capillary, filters etc jointing/brazing of copper refrigerant suction and discharge pipe line with and including charging of refrigerant gas to required level complete including cleaning of condenser fins, leakage testing etc including testing for smooth functioning complete all as specified and directed
S&F PCB plate of AC split type 1.5 Ton/2 Ton with new remote complete all as specified and directed. Make- LG/ Voltas/ Sidwal/ Carrier/Videocon
Repair/servicing to RO system with dismantling the accessories carefully of capacity up to 50 Ltrs per hour and any type /make after disconnecting the electric connections if required, making necessary repairs by replacing following parts refixing the same in its original position testing and re-fixing properly at the same place all as specified and as directed. Notes :- Replacement of material shall be measured and paid under the relevant items
Supply only Pre filter for RO system up to 50 Ltr capacity complete all as specified
Supply only Carbon block filter for up to 50 Ltrs capacity complete all as specified
Supply only UV for RO system up to 50 ltrs capacity complete all as specified
Supply only Membrane for RO up to 12 to 15 ltrs capacity complete all as specified
Supply only Pressure pump for RO up to 12 to 15 ltrs capacity complete all as specified
S&F in repair sub main wiring with two runs of single core PVC, FRLS sheathed, insulated, copper cable of 4 Sqmm size, multi stranded, 1100 volts grade with PVC insulated FRLS copper wire 4 Sqmm for continuous earth wire drawn into and existing concealed conduit of suitable size not less than 20mm dia complete all as specified and directed . Note :- Two runs of 4 Sqmm copper cable and one run of 4 sqmm copper wire earth continuity conductor in conduit with accessories shall be measured as one length)
GS and Co (BID ID -3427302)
V R TRADERS (BID ID -3420952)
RAJINDRA AIR CONDITINOR FABRICATORS (BID ID -3427704)
SHIV SHAKTI BUILDERS (BID ID -3427870)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .