| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 CrAccepted-AOC 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹44.4 Cr Quoted ₹44.5 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹44.9 CrRejected-Finance A 2 45 JANAKPURI NEW DELHI 110058 | NEW DELHI | NEW DELHI | DELHI | 110058 | ₹44.9 Cr | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹44.9 CrRejected-Finance 11 JAMES HICKEY SARANI FORMALLY KNOWN AS DACRES LANE 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | ₹44.9 Cr | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹47.0 CrRejected-Finance | ₹47.0 Cr | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹47.5 CrRejected-Finance | ₹47.5 Cr | L5 | Rejected-Finance Other than L1 |
Tender Value
₹51.1 Cr
EMD Value
₹15 L
Closing Date
30 Dec 2024, 6:00 pmClosed
SR DDG and CE
DGNP, Mumbai-01
MAJOR AUGMENTATION AND AUTOMATION OF WED STORE HOUSE AT MANKHURD- PHASE-II, MUMBAI
2024_MES_678977_1
8558
Open Tender
Civil Works
730 days
Naval Dockyard Mumbai
Please refer Tender documents.
10 documents required · 10 mandatory
₹3,000
DGNP Mumbai
₹15 L
8 May 2025
10 Oct 2024
31 Dec 2024
10 Oct 2024
30 Dec 2024
15 Nov 2024
Amount
LIST OF WORKS (Schedule A Part I to Part XIV)
Total amount of Sch 'A' Part-I (Building Works) brought forwarded from sl page No 27.
Total amount of Sch 'A' Part-II (Earth Work & Site clearance) brought forwarded from sl page No 28.
Total amount of Sch 'A' Part-III (Internal Electrification) brought forwarded from sl page No 32R).
Total amount of Sch 'A' Part-IV (Internal Water supply) brought forwarded from sl page No 34(R).
Total amount of Sch 'A' Part-V (Road/Hard standing) brought forwarded from sl page No 37.
Total amount of Sch 'A' Part-VI (Sewage Disposal ) brought forwarded from sl page No 38(R).
Total amount of Sch 'A' Part-VII (Area Drainage) brought forwarded from sl page No 39(R).
Total amount of Sch 'A' Part-VIII (External Electrification) brought forwarded from sl page No 41(R).
Total amount of Sch 'A' part- IX (Fire Fighting) brought forwarded from sl page No 43(R).
Total amount of Sch 'A' part- X (Water Cooler) brought forwarded from sl page No 44(R).
Total amount of Sch 'A' part- XI (Arboriculture ) brought forwarded from sl page No 45(R).
Total amount of Sch 'A' part- XII (Lift) brought forwarded from sl page No 46(R).
Total amount of Sch 'A' part- XIII (Demolition & Dismantling) brought forwarded from sl page No 48(R).
Subtotal
Sch 'A' Part- XIV(MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
INTERNAL ELECTRIFICATION
TPN DB(LPDB)- 12Way TPN DB, Main Incoming: 63A, TPN, MCB,Sub Incomers-40A,DP,100ma,RCBO - 3Nos. With Outgoings: -16-20A 10KA SP MCB- 36Nos.
TPN DB(LPDB)- 8Way TPN DB, Main Incoming: 63A, TPN, MCB,Sub Incomers-40A,DP,100ma,RCBO - 3Nos. With Outgoings: -16-20A 10KA SP MCB- 24Nos.
TPN DB(LPDB)- 6Way TPN DB, Main Incoming: 63A, TPN, MCB,Sub Incomers-40A,DP,100ma,RCBO - 3Nos. With Outgoings: -16-20A 10KA SP MCB- 18Nos.
12Way SPN DB ,(UPS&ELDB), Incoming: 32A,DP,100ma,RCBO,. Outgoings: -16A 10KA SP MCB- 10Nos.
TPN DB(ACDB)- 6Way TPN DB, Main Incoming: 63A, TPN, MCB,Sub Incomers-40A,DP,100ma,RCBO - 3Nos. With Outgoings: -16-20A 10KA SP MCB- 18Nos. (FUTURE PURPOSE)
Supply,Erection,Testing & Commissioning of 200W LED Pressure die-cast aluminum housing with polycarbonate direct lens. LED module fixed on die-cast aluminum heat sink for proper thermal management and constant current driver with built-in surge protection,open & short circuit protection. System efficacy should not be less than 160lm/W and nominal system lumens should not be less than 32000 lumens, CRI > 70, CCT 5700K and lifetime of 50,000 hours. Operating Temperature Range -20degC to 50degC , THD<10 %, Innovative LED layout & heat sink design improve airflow and enhance heat dissipation for better performance. Input voltage range of 140V to 270V, 4kV internal + 10kV External surge protection. IP rating of IP66 and IK07 impact resistance. XE version is with EMI/EMC compliant IP67 rated & constant current driver. 200W SUSPENDED HIGHBAY WITH 160LM/W 5700K 32000 LUMENS OUTPUT 60 DEGREE BEAM ANGLE
Supply,Erection,Testing & Commissioning of 40W LED luminaire comprising of powder coated aluminium housing and special Opal diffuser for smooth light distribution. Constant current integral LED Driver is provided, having open/short circuit protection and Built-in surge protection. Luminaire is suitable for surface mounting. Housing color: white . System efficacy should not be less than 120lm/W and nominal system lumens should not be less than 4800 lumens, CRI > 80, CCT 5665K ±355K. Operating Temperature Range 0degC to 45degC, Constant Current driver suitable to operate in input voltage range of 180V to 270V (nominal rated voltage – 240V) 4kV internal surge protection . IP rating of IP20 40W INDUSTRIAL BATTEN EXTRUDED ALUMINIUM HOUSING WITH 120LM/W
Supply,Erection,Testing & Commissioning of 36W LED Luminaire with visual comfort ,Recess Mounted Sleek and Seamless aesthetics with CRCA steel sheet housing and Opal diffuser fixed in separate engineered plastic frame. White powder coated Housing finish Uniformly lit special diffuser with well distributed light suitable for Armstrong and grid ceiling.The Luminaire shall be designed to emit at least 3600 nominal lumens with system efficacy of at least 120 lumen/watt.Luminaire should have CRI > 80, and CCT of 5665K+355K and shall be compliant with IP20 classification. Operating Temperature Range is -10degC to 45degC. The luminaire shall be designed to ensure lumen depreciation L70 over 25000 burning hours as per LM 80 report. Constant current driver , with power factor >0.90 with a built-in surge protection of 4kV and input operating voltage range of 180 to 270V AC. Driver should comply Driver safety requirements as per IS 15885 with BIS certification.Manufacture should have in house NABL testing facility & LM80 report from LED manufacturer. LM 79 report from NABL accredited Lab shall be submitted. The luminaire should comply with all the required IEC and IS standards.The supplier or OEM shall ensure that brand name should be visible on all equipment supplied for the work and same should be eponymous as their company name as per incorporation documents. 36W 2X2 RECESS OR SURFACE MOUNTED CRCA HOUSING WITH 120LM/W (36W 2X2 LIGHT FIXTURE)
Supply,Erection,Testing & Commissioning of 20W LED luminaire comprising of extruded aluminium housing with engg. plastic end caps and Opal diffuser for smooth light distribution . LED’s connected in series parallel and populated on FR4 PCB. Luminaire is suitable for surface mounting. Housing color: white . System efficacy should not be less than 120lm/W and nominal system lumens should not be less than 2400 lumens, CRI > 80, CCT 6530K ±510K. Operating Temperature Range 0degC to 45degC, Constant Current driver suitable to operate in input voltage range of 180V to 270V (nominal rated voltage – 240V) 4kV internal surge protection . IP rating of IP20 . 20W INDUSTRIAL BATTEN EXTRUDED ALUMINIUM HOUSING WITH 120LM/W (20W TUBE LIGHT)
Supply,Erection,Testing & Commissioning of 18W LED luminaire comprising of Engineered Plastic housing and Opal diffuser for uniform lighting.. Luminaire is suitable for surface mounting with seamless integration with ceiling. Housing color: white. System efficacy should not be less than 120lm/W and nominal system lumens should not be less than 1800 lumens, CRI > 80, CCT 6500K . Operating Temperature Range 0degC to 45degC, Constant Current driver suitable to operate in input voltage range of 140V to 270V (nominal rated voltage – 240V) 4kV internal surge protection . IP rating of IP20 . 18W RECESS OR SURFACE MOUNTED DOWNLIGHT WITH 120LM/W(18W DOWN LIGHT)
Supply,Erection,Testing & Commissioning of 12W LED luminaire comprising of Engineered Plastic housing and Opal diffuser for uniform lighting.. Luminaire is suitable for surface mounting with seamless integration with ceiling. Housing color: white. System efficacy should not be less than 100lm/W and nominal system lumens should not be less than 1200 lumens, CRI > 80, CCT 6500K . Operating Temperature Range 0degC to 45degC, Constant Current driver suitable to operate in input voltage range of 140V to 270V (nominal rated voltage – 240V) 4kV internal surge protection . IP rating of IP20 . 12W RECESS OR SURFACE MOUNTED DOWNLIGHT WITH 120LM/W (12W DOWN LIGHT)
WATER SUPPLY EXTERNAL Supply, installation, testing and commissioning approved make high quality G.I.Class 'B' Pipes with 50 mm dia, GI malleable specials such as tees, elbows, check nuts, unions, flanges, reducers, supports for the pipes traveling above ground, clamps, etc., including threading, cutting and fixing in/on walls ceiling, ground, terrace floor etc., The rate shall include for necessary chasing the walls and making bores wherever required and making good the chased surfaces and bores in cement mortar etc., complete.
20 mm dia (Screwed ends)
25 mm dia (Screwed ends)
32 mm dia (Screwed ends)
Supply, installation, testing and commissioning in position control lever operated type C.I body Butterfly Valve with 65 mm dia (Flanged ends) , matching companion flanges, bolts, nuts, rubber gasket etc., complete
Supply, installation, testing and commissioning of Level Sensor shall consist of control unit, preamplifier and one full insulated probe-mounted vertically or two part insulated probe mounted from tanks side wall adjustable switching system for pump control application, the same to be housed in stove enamel painted cast aluminium weather proof suitable for black panel / wall mounting etc.
2 core x 1.5 sq.mm cable
Supply and Fixing of 25mm dia Air Release Valves for water risers.
GI angle iron brackets using 40 x 40 x 6`mm thick for supporting water supply, soil and waste pipe on walls/ceiling by using hanger rods welded/grounted and the brackets shall be given two coats of anti corrosive paint over a coat of primer etc., complete as per drawing or as per site requirements.
Supply and Installation of Main Pump of capacity 2280 Lpm 70 Mtrs Head electrical hydrant pump.
SEWAGE DISPOSAL
Supply and fixing precast RCC septic tank of capacity 25000 Ltr including conecting with sewage line and necessary requirement of T & P for installation of septic tank complete all as specified and directed by Engineer-in-charge.
EXTERNAL ELECTRIFICATION
11KV OUTDOOR HT PANEL (11KV 3WAY HT RMU PANEL)
INCOMING (1 No's) Each Consisting of Following
CB:-(1 Set): 11KV, 1250A, 25KA For 1Sec Horizontal Draw out type VCB Manually and Motor Operated spring charging mechanism, With 230V AC Supply for Motor,110V DC for shunt Trip coil and Closing Coil. Axu. Contact 4No+4Nc, Mechanical ON and OFF indicator and Push button, Mechanical operation counters with lightining surge arrester.The Each VCB Shall be Provided with DC Power Pack, AUXILIARY SWITCH 6NO + 6NC, Aluminium BUSBAR WITH HEAT SHRINKABLE HT SLEEVE- 1250A, 25kA/3sec STC, PAINT SHADE - FRONT / REAR , LV DOOR S & COVERS - RAL9003 (as per final technical clarification), DEGREE OF PROTECTION - IP42, BOTTOM CABLE ENTRY, MECHANICAL ON / OFF INDICATOR
CURRENT TRANSFORMER : - (1 Set) 11KV ,25kA FOR 1SEC CURRENT TRANSFORMER:- (1 Set), CT Current Ratio:-: 100/1/1A, Core-1: CL. 0.5, 15VA - (Metering), Core-2: CL. 5p10, 15VA - (Protection), 11KV CBCT,25kA FOR 1SEC.CURRENT RATIO:- 100/1/1A
LINE POTENTIAL TRANSFORMER (STAR - STAR-STAR) : - (1 Set) , Cast resin PT with HT and LT HRC Fuses, Ratio:11KV/√3/110v/√3 /110v/√3 Three Phase, Burden 100 VA, Core-1:-CL. 0.5 for metering, Core-2:-CL. 3P for Protection
PROTECTION RELAYS: ( RELAYS as per requirement of IEC 61850 protocol), ECOX - 6 Nos. Thermal Sensors (3Nos. Cable Compartment + 3Nos. Busbar Compartment) per Feeder + 2 Nos. Humidity (Climate sensors) per offered Board 1) TRIPLE POLE NON DIRECTIONAL IDMT - 2 O/C + 1 E/F-((50/50N 51/51N) Digital Numerical relay and shall be compatable for BMS with communication port.-1 No. 2) Master Trip Relay -(86) - (1No), 3) Trip Circuit Super Vision Relay -(95) - (1No) 4) Instantaneous Overcurrent with Ground Fault-(50G) 5) ANTI PUMPING RELAY (SEPARATE CONTACTOR)-94
BREAKER PANEL INDICATION LAMPS : 1) ON, OFF and Trip Indication Lamps for RYB. - (1 set), 2) Trip Circuit Healthy lamp - (1 set), 3) Spring Charging lamp - (1 set) 4) Auto trip - (1 set) 5) LED Type R-Y-B Phase Indication Lamps - (1 set) 6) TRIP CIRUIT SUPERVISION - (1 set) 7) TEST POSITION - (1 set) 8)SERVICE POSITION - (1 set) 9) R-Y-B HEALTHY - (1 set) DC SUPPLY HEALTHY INDICATION - (1 set)
OUTGOING - 1&2: (2 No's) Each Consisting of Following
CB:-(1 Set): 11KV, 800A, 25KA For 1Sec Horizontal Draw out type VCB Manually and Motor Operated spring charging mechanism, With 230V AC Supply for Motor,110V DC for shunt Trip coil and Closing Coil. Axu. Contact 4No+4Nc, Mechanical ON and OFF indicator and Push button, Mechanical operation counters with lightining surge arrester.The Each VCB Shall be Provided with DC Power Pack, AUXILIARY SWITCH 6NO + 6NC, Aluminium BUSBAR WITH HEAT SHRINKABLE HT SLEEVE- 800A, 25kA/1sec STC, PAINT SHADE - FRONT / REAR , LV DOOR S & COVERS - RAL9003 (as per final technical clarification), DEGREE OF PROTECTION - IP42, BOTTOM CABLE ENTRY, MECHANICAL ON / OFF INDICATOR
CURRENT TRANSFORMER : - (1 Set), 11KV ,25kA FOR 1SEC CURRENT TRANSFORMER:- (1 Set), CT Current Ratio:-: 100/1/1A, Core-1: CL. 0.5, 15VA - (Metering), Core-2: CL. 5p10, 15VA - (Protection), 11KV CBCT,25kA FOR 1SEC.CURRENT RATIO:- 100/1/1A
LINE POTENTIAL TRANSFORMER (STAR - STAR-STAR) : - (1 Set), Cast resin PT with HT and LT HRC Fuses, Ratio:11KV/√3/110v/√3/110v/√3 Three Phase, Burden 100 VA, Core-1:-CL. 0.5 for metering ,Core-2:-CL. 3P for Protection
PROTECTION RELAYS: ( RELAYS as per requirement of IEC 61850 protocol), ECOX - 6 Nos. Thermal Sensors (3Nos. Cable Compartment + 3Nos. Busbar Compartment) per Feeder + 2 Nos. Humidity (Climate sensors) per offered Board) 1) TRIPLE POLE NON DIRECTIONAL IDMT - 2 O/C + 1 E/F-((50/50N 51/51N) Digital Numerical relay and shall be compatable for BMS with communication port.-1 No. 2) Master Trip Relay -(86) - (1No) 3) Trip Circuit Super Vision Relay -(95) - (1No) 4) Instantaneous Overcurrent with Ground Fault-(50G) 5) ANTI PUMPING RELAY (SEPARATE CONTACTOR)-94
BREAKER PANEL INDICATION LAMPS : 1) ON, OFF and Trip Indication Lamps for RYB. - (1 set), 2) Trip Circuit Healthy lamp-(1 set), 3) Spring Charging lamp - (1 set), 4) Auto trip. - (1 set), 5) LED Type R-Y-B Phase Indication Lamps. - (1 set), 6) TRIP CIRUIT SUPERVISION - (1 set), 7) TEST POSITION - (1 set), 8) SERVICE POSITION - (1 set), 9) R-Y-B HEALTHY - (1 set), 10) DC SUPPLY HEALTHY INDICATION - (1 set)
DRY TYPE TRANSFORMERS: Supply, erection, testing, commissioning and installation of 11KV / 433V, 1250KVA, 50Hz, Z=6.25% (DRY TYPE) , transformer with OLTC, RTCC & AVR with ±10% instep of 1.25% manufactured as per IS 1180 Energy Efficiency Level 2 with all standard accessories and as per MSEDCL approved standards as per Technical Specification and SLD. Rating:- 1250 KVA 1) Installation:- INDOOR ONLY 2) Type Two Windings, Cast Resin-Dry Type 3) Cooling:- AN/AF (unless otherwise specified) 4) Phase:- 3 Phase 5) Primary Voltage:- 11kV (As specified in BoQ) 6) Secondary Voltage:- 433 V 7)Tap changeover:- ON LOAD ( As specified in BoQ) 8)Tapping on windings HV/LV :-HV winding 9)Motorized load tap changer (if specified):- -15% to +5%, In steps of 1.25% 10)Winding connection:- H.V Delta ,L.V Star grounded 11) Winding material:- Copper 12) Vector Group:- Dyn 11 13) Percentage Impedance:- As per IS 14) Losses Unless otherwise specified,:- as per table 7.1 (Page no, 76) of ECBC-2017 Revision: April, 2018 and subsequent revisions thereof, by BEE, Govt. of India 15) Neutral CT:- REQUIRED 16) Fault Level HV system:- 350 MVA 17) Transformer Neutral:- Effectively earthed through an additional bushing on LV side 18) Transformer Terminations: Primary side 11kV (E) XLPE Aluminum Conductor armored cable 19) Secondary side Bus-duct:- (2000A SANDWICH TYPE BUSDUCT)
MAIN PCC PANEL ( The MPCC Consisting of the Following ) (INDOOR PANEL)
ELECTRICAL + MECHANICAL INTERLOCKING (ALL THE NECESSARY ACCESSORIES SHOULD BE TAKEN INTO THE PANEL FOR E+M INTRACTION) Incomer-1 (From EB - Transformer - 1), 2000A, 4P, EDO ACB of 50KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases -6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 2000/5A, CL-1, 15VA, Tape wound CT's - 3Nos Incomer-2 (From DG PANEL), 630A, 4P, MCCB of 50KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases - 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 320/5A, CL-1, 15VA, Tape wound CT's - 3Nos
Outgoing Feeders on BUSBAR-1: 1) 1250A, 4P, EDO ACB of 50KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases -2 Nos (1 DEDICATED + 1SPARE) Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 1250/5A, CL-1, 15VA, Tape wound CT's - 3Nos. 2) 630A, 4P, MCCB of 35KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases -2 Nos (1 DEDICATED + 1 SPARE). Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 630/5A, CL-1, 15VA, Tape wound CT's - 3Nos 3) 320A, 4P, MCCB of 35KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases -1 Nos (1 DEDICATED ). Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 320/5A, CL-1, 15VA, Tape wound CT's - 3Nos 4) 200A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -1 Nos (1 DEDICATED ). Each consisting of following 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 200/5A, CL-1, 15VA, Tape wound CT's - 3Nos 5). 125A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -4 Nos (4DEDICATED). Each consisting of following 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. - (1 set)On,Off & Trip Indications: (1 sets ) 125/5A, CL-1, 15VA, Tape wound CT's - 3Nos 6) 100A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -1 Nos (1DEDICATED). Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ), 100/5A, CL-1, 15VA, Tape wound CT's - 3Nos
Busbar-1: 415V, 3000A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 50KA for 1 Sec. - LS (with 50% Neutral)
Outgoing Feeders on BUSBAR-2: 1600A, 4P, EDO ACB of 50KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases -2 Nos (1 DEDICATED + 1SPARE). Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No.LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 1600/5A, CL-1, 15VA, Tape wound CT's - 3Nos
Busbar-2: 415V, 3000A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 50KA for 1 Sec. - LS (with 50% Neutral)
BUS COUPLER : 2000A, 4P, EDO ACB of 50KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases
SPD: This panel shall include Mains Incoming Panel:Protection at the main incomer of the power supply system has to be connected at the Main Distribution Board after the incoming breaker. CLASS B SPD -TYPE I -MAIN DISTRIBUTION PANEL(THREE PHASE+ NEUTRAL) The SPD should be connected between Phase and Neutral and between Neutral and Earth with the following ratings: Nominal Voltage, Un -230V, 50/60 Hz,Line to Neutral-MOV with built in thermal fuse,Neutral to Earth-Spark Gap Encapsulated / Non-exhausting,MCOV of 320V Total Impulse current -50 kA (10/350µ sec) - 12.5 kA each. Voltage protection level <1.5 kV. Protection Modes for : L & N to PE. Maximum Discharge Current Imax per pole-50 kA (8/20µ sec) Mounting on -Din rail Max. Back-up fuse-Up to 500 amps max. Depending up on panel design & breaking capacity. rovals:UL Degree of Protection:IP 20 Operating temperature range:-40°C to +85°C Response Time-< 100 nano seconds Remote signaling:Visual Model Number- ,MCD 50 B 0S -320 V+MCD 125 B NPE ,BACK UP FUSE NEEDED 250 A, 3PHASE , 4 WIRE SYSTEM DIN RAIL MOUNTED SPD CLASS B SPD-TYPE-1 Quantity-2No
600KVAR CAPACITOR BANK APFC PANEL(INDOOR Type) - 1No Panel consisting of the following
(ii) Outgoings: 1) 250A, TP ,35KA Thermal Magnetic MCCB with OverLoad & Short circuit Protections- 5No's. Each consisting of following 100KVAR CAPACITOR DUTY CONTACTOR 7% DETUNED COPPER REACTOR100KVAR CAPACITOR BANK @ 480V MPP HEAVY DUTY CAPACITOR BANK ON / OFF INDICATING LAMPS START/STOP PUSH BUTTONS 2) 63A, 3P, MCCB of 10KA breaking capacity with O/C, S/C, E/F and Thermal Magnetic based Releases -3Nos. Each consisting of following 25KVAR CAPACITOR DUTY CONTACTOR 7% DETUNED COPPER REACTOR 25KVAR CAPACITOR BANK @ 480V MPP HEAVY DUTY CAPACITOR BANK ON / OFF INDICATING LAMPS START/STOP PUSH BUTTONS 3) 40A, 3P, MCCB of 10KA breaking capacity with O/C, S/C, E/F and Thermal Magnetic based Releases -1Nos. Each consisting of following 15KVAR CAPACITOR DUTY CONTACTOR 7% DETUNED COPPER REACTOR 15KVAR CAPACITOR BANK @ 480V MPP HEAVY DUTY CAPACITOR BANK ON / OFF INDICATING LAMPS START/STOP PUSH BUTTONS 4) 32A, 3P, MCCB of 10KA breaking capacity with O/C, S/C, E/F and Thermal Magnetic based Releases -1Nos. Each consisting of following 10KVAR CAPACITOR DUTY CONTACTOR 7% DETUNED COPPER REACTOR 10KVAR CAPACITOR BANK @ 480V MPP HEAVY DUTY CAPACITOR BANK ON / OFF INDICATING LAMPS START/STOP PUSH BUTTONS Note - All Capacitors Should be with DETUNED FILTERS.
(iii) Bus Bar: 415V, 1250A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 50 KA for 1 Sec. - LS
(iv) SPD: This panel shall include Mains Incoming Panel: Protection at the main incomer of the power supply system has to be connected at the Main Distribution Board after the incoming breaker. CLASS B SPD -TYPE I -MAIN DISTRIBUTION PANEL (THREE PHASE+ NEUTRAL). The SPD should be connected between Phase and Neutral and between Neutral and Earth with the following ratings:- 1. Nominal Voltage, Un -230V, 50/60 Hz, Line to Neutral-MOV with built in thermal fuse, Neutral to Earth-Spark Gap Encapsulated / Non-exhausting, MCOV of 320V 2. Total Impulse current -50 kA (10/350µ sec) - 12.5 kA each. 3. Voltage protection level <1.5 kV. 4. Protection Modes for: L & N to PE. Maximum Discharge Current Imax per pole-50 kA (8/20µ sec) 5. Mounting on -Din rail Max. 6. Back-up fuse-Up to 500 amps max. 7. Depending up on panel design & breaking capacity. 8. Approvals :UL 9. Degree of Protection : IP 20 10. Operating temperature range:-40°C to +85°C 11. Response Time-< 100 Nano seconds Remote signalling Quantity-2No
(c) GROUND FLOOR (LIGHTING,POWER,AC DISTRIBUTION-LPDB AND ACDB)
(i) Incomer: 125A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -Each consisting of following. 6A, control MCB of C-Curve - 3Nos, Multifunction Meter(MFM) With RS485 communication port - 1 No, LED Type R-Y-B Phase Indication Lamps -(1 set), On,Off & Trip Indications: (1 sets ), 125/5A, CL-1, 15VA, Tape wound CT's - 3Nos
(ii) Outgoing: 63A, TPN, MCB of 10KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -7 Nos (4 DEDICATED + 3 SPARE)
(iii) Busbar: 415V, 160A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 25 KA for 1 Sec. - LS
(iv) SPD: This panel shall include Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system.Class B+C/Class I+II (according to IEC 61643 - 1)(THREE PHASE+ NEUTRAL) Class B+C/Class I+II (according to IEC 61643 - 1) Pluggable type SPD with potential free contact and thermal disconnector has to be connected between Line and Neutral and SPD of Spark Gap type between Neutral and Earth of following ratings should include base element & pluggable arresters. If required, remote signaling should be provided for remote monitoring purpose. Nominal Voltage, Un -230V, 50/60 Hz,Line to Neutral-MOV with built in thermal fuse,Neutral to Earth-Spark Gap Encapsulated / Non-exhausting,MCOV of 320V Nominal current -90 kA (8/20µ sec) - 30 kA each. Voltage protection level <1.4 kV. Protection Modes for : L & N to PE. Maximum Discharge Current Imax per pole-50 kA (8/20µ sec) Mounting on -Din rail Max. Back-up fuse-Up to 160 amps max. Depending up on panel design & breaking capacity. Approvals: OVE Degree of Protection:IP 20 Operating temperature range:-40°C to +85°C Response Time-< 25nano seconds Quantity-1No
(TYPICAL) FIRST & SECOND FLOOR (LIGHTING,POWER,AC DISTRIBUTION-LPDB AND ACDB)
(i) Incomer: 125A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -Each consisting of following. 6A, control MCB of C-Curve - 3Nos, Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. - (1 set) , On,Off & Trip Indications: (1 sets ), 125/5A, CL-1, 15VA, Tape wound CT's - 3Nos
(ii) Outgoing: 63A, TPN, MCB of 10KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -7Nos (4 DEDICATED + 3 SPARE)
(iii) Busbar: 415V, 160A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 25 KA for 1 Sec. - LS
(iii) Busbar: 415V, 160A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 25 KA for 1 Sec. - LS
(iv) SPD: This panel shall include Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Class B+C/Class I+II (according to IEC 61643 - 1)(THREE PHASE+ NEUTRAL) Class B+C/Class I+II (according to IEC 61643 - 1) Pluggable type SPD with potential free contact and thermal disconnector has to be connected between Line and Neutral and SPD of Spark Gap type between Neutral and Earth of following ratings should include base element & pluggable arresters. If required, remote signaling should be provided for remote monitoring purpose. Nominal Voltage, Un -230V, 50/60 Hz,Line to Neutral-MOV with built in thermal fuse,Neutral to Earth-Spark Gap Encapsulated / Non-exhausting,MCOV of 320V Nominal current -90 kA (8/20µ sec) - 30 kA each. Voltage protection level <1.4 kV. Protection Modes for : L & N to PE. Maximum Discharge Current Imax per pole-50 kA (8/20µ sec) Mounting on -Din rail Max. Back-up fuse-Up to 160 amps max. Depending up on panel design & breaking capacity. Approvals: OVE Degree of Protection:IP 20 Operating temperature range:-40°C to +85°C Response Time-< 25nano seconds Quantity-1No
THIRD FLOOR (LIGHTING,POWER,AC DISTRIBUTION-LPDB AND ACDB)
(i) Incomer: 125A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps.- (1 set)On,Off & Trip Indications: (1 sets ) 125/5A, CL-1, 15VA, Tape wound CT's - 3Nos
(ii) Outgoing: 63A, TPN, MCB of 10KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -9 Nos (6 DEDICATED + 3 SPARE)
(iii) Busbar: 415V, 160A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 25 KA for 1 Sec. - LS
(iv) SPD: This panel shall include Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Class B+C/Class I+II (according to IEC 61643 - 1)(THREE PHASE+ NEUTRAL) Class B+C/Class I+II (according to IEC 61643 - 1) Pluggable type SPD with potential free contact and thermal disconnector has to be connected between Line and Neutral and SPD of Spark Gap type between Neutral and Earth of following ratings should include base element & pluggable arresters. If required, remote signaling should be provided for remote monitoring purpose. Nominal Voltage, Un -230V, 50/60 Hz,Line to Neutral-MOV with built in thermal fuse,Neutral to Earth-Spark Gap Encapsulated / Non-exhausting,MCOV of 320V Nominal current -90 kA (8/20µ sec) - 30 kA each. Voltage protection level <1.4 kV. Protection Modes for : L & N to PE. Maximum Discharge Current Imax per pole-50 kA (8/20µ sec) Mounting on -Din rail Max. Back-up fuse-Up to 160 amps max. Depending up on panel design & breaking capacity. Approvals: OVE Degree of Protection:IP 20 Operating temperature range:-40°C to +85°C Response Time-< 25nano seconds Quantity-1No
ALL FLOORS ( EMERGENCY LIGHTING AND UPS POWER DISTRIBUTION-EL&UPSDB )
(i) Incomer: 100A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -Each consisting of following.
(ii) Outgoing: 32A, DP, MCB of 10KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -10 Nos (7 DEDICATED + 3 SPARE)
(iii) Busbar: 415V, 125A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 25 KA for 1 Sec. - LS
COMMON SERVICE PANEL
(i) Incomer: 320A, 4P, MCCB of 35KA breaking capacity with O/C, S/C, E/F and Micro proceser based Releases - Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. -(1 set) On,Off & Trip Indications: (1 sets ) 320/5A, CL-1, 15VA, Tape wound CT's - 3Nos
(ii) Outgoing: 1) 100A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -2 Nos (1 DEDICATED + 1SPARE) 2) 63A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -3 Nos (1 DEDICATED + 2SPARE) 3) 32A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -9 Nos (7 DEDICATED + 2SPARE)
(iii) Busbar:415V, 400A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 35 KA for 1 Sec. - LS
(iv) SPD: This panel shall include Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Class B+C/Class I+II (according to IEC 61643 - 1)(THREE PHASE+ NEUTRAL) Class B+C/Class I+II (according to IEC 61643 - 1) Pluggable type SPD with potential free contact and thermal disconnector has to be connected between Line and Neutral and SPD of Spark Gap type between Neutral and Earth of following ratings should include base element & pluggable arresters. If required, remote signaling should be provided for remote monitoring purpose. Nominal Voltage, Un -230V, 50/60 Hz,Line to Neutral-MOV with built in thermal fuse,Neutral to Earth-Spark Gap Encapsulated / Non-exhausting,MCOV of 320V Nominal current -90 kA (8/20µ sec) - 30 kA each. Voltage protection level <1.4 kV. Protection Modes for : L & N to PE. Maximum Discharge Current Imax per pole-50 kA (8/20µ sec) Mounting on -Din rail Max. Back-up fuse-Up to 160 amps max. Depending up on panel design & breaking capacity. Approvals: OVE Degree of Protection:IP 20 Operating temperature range:-40°C to +85°C Response Time-< 25nano seconds Quantity-1No
INDUSTRIAL SOCKET PANEL
Incomer: 630A, 4P, MCCB of 50KA breaking capacity with O/C, S/C, E/F and Micro proceser based Releases - Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 630/5A, CL-1, 15VA, Tape wound CT's - 3Nos
Outgoing: 1) 32A, TP, MCB of 10KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -43 Nos ( 40 DEDICATED + 3SPARE) 2) 20A, DP,
(MCB of 10KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -43 Nos ( 40 DEDICATED + 3SPARE)
Busbar: 415V, 800A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 50 KA for 1 Sec. - LS
SPD: This panel shall include Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Class B+C/Class I+II (according to IEC 61643 - 1)(THREE PHASE+ NEUTRAL) Class B+C/Class I+II (according to IEC 61643 - 1) Pluggable type SPD with potential free contact and thermal disconnector has to be connected between Line and Neutral and SPD of Spark Gap type between Neutral and Earth of following ratings should include base element & pluggable arresters. If required, remote signaling should be provided for remote monitoring purpose. Nominal Voltage, Un -230V, 50/60 Hz,Line to Neutral-MOV with built in thermal fuse,Neutral to Earth-Spark Gap Encapsulated / Non-exhausting,MCOV of 320V Nominal current -90 kA (8/20µ sec) - 30 kA each. Voltage protection level <1.4 kV. Protection Modes for : L & N to PE. Maximum Discharge Current Imax per pole-50 kA (8/20µ sec) Mounting on -Din rail Max. Back-up fuse-Up to 160 amps max. Depending up on panel design & breaking capacity. Approvals: OVE Degree of Protection:IP 20 Operating temperature range:-40°C to +85°C Response Time-< 25nano seconds Quantity-1No
BUS BAR TRUNKING SYSTEM :
Supply, erection, testing and commissioning of 415V, 50 Hz. 3Phase+50% Neutral, 2000 Amps 50 kA 4P (IP 68) Sandwich BUSDUCT [Between TRANSFORMER TO MAIN PCC PANEL] . The Busbar Trunking System shall be of Sandwich construction, . It shall be possible to mount the Busbar Trunking System in any orientation without affecting the current rating. The busbars should be made of high conductivity electrical grade Aluminum (60%). The Purity of Aluminum conductor should not be less than 99.6%, the joint area should be Tin plated. Inside should be Class-F, each layer shall have withstand breakdown voltage of minimum 6kv. The insulation material used shall be of minimum class of (155 deg.c) with UL Certified. Housing shall be made of 1.6mm electro-galvanized sheet steel, epoxy powder coated with RAL7032 shade, indoor busduct must be IP-54 / IP-55 & Outdoor busduct should be IP-65 / IP-66 with canopy. This includes bends/flangers/connectors etc as per the requirements to work done as per the site conditions. NOTE: 1) ALL THE BUS DUCTS WHICH ARE BEING LAID AND TERMINATED OUTDOOR SHALL BE PROVIDED WITH IP-68 PROTECTIONS ALONG WITH CANOPY.
UPS/INVERTERS : Supply , Erection ,testing and Commisioning of 20KVA Microprocessor based double conversion on line UPS System with 3 phase input and 3ph output IGBT Based as per the requirement/ Technical Specifications including SMF Batteries to provide 90 Minutes backup with necessary accessories (Considered Battery Racks, interlinks, 5 Mtrs UPS to battery cable) .
HT/LT CABLE SUPPLYING AND LAYING. Supplying, laying, testing and commissioning of cables of the following sizes of cables on trays built up trenches or through GI pipes or clamping to column wall or structure using GI spacers and saddles (at an interval of 300mm for cables of OD up to 25mm and 500mm for the cables) scope shall includes supply of these saddles, hardware and consumables. Cables laid in trays shall be dressed and tied with black nylon ropes in the horizontal portions and clamped using the GI saddles at every 750mm in the vertical portion. What ever cables are laid through GI pipes scopes shall also include sealing the mouth of the GI pipes. Where ever cables are to be laid in built up trenches work shall be includes opening the RCC slabs before laying and replacing them after laying. The work shall be carried out as per the specification and as per the directions of the Engineer-in-charge.NOTE:All Aluminium Cable(Size) complying to IS 7098 Part 1,XLPE insulation,Inner & Outer Sheath complying ST2, Armoured Cable.
4 C XLPE Cable ( AL & CU both)
3 C x 2.5 Sq.mm Cu,Flexible Cable (Specifcally For Internal Cabling/Wiring of all the High Bay Light Fixtures.)
3 C x 10 Sq.mm AL,Ar XLPE Cable
CABLE TERMINATIONS (including supply of cable glands and lugs)
3.5 C AL,Ar XLPE Cable (Only AL)
3.5 C x 240 Sq.mm
3.5 C x 185 Sq.mm
3.5 C x 95 Sq.mm
3.5 C x 70 Sq.mm
3.5 C x 50 Sq.mm
3.5 C x25 Sq.mm
CABLE TERMINATIONS (including supply of cable glands and lugs) Aliminium Armoured XLPE Cable OF FOLLOEING SIZES4 C XLPE Cable ( AL & CU both)
4 C x 25 Sq.mm
4 C x 10 Sq.mm
3 C x 6 Sq.mm
3 C x 2.5 Sq.mm Cu,Flexible Cable (Specifcally For Internal Cabling/Wiring of all the High Bay Light Fixtures.)
3 C x 10 Sq.mm AL,Ar XLPE Cable
FRLS Control Cables. (All below Mentioned Cables are Provided for Transformer and DG set Control Wiring)
14Cx2.5 Armoured Copper Cable.
4Cx2.5 Armoured Copper Cable.
3Cx2.5 Armoured Copper Cable.
2Cx2.5 Armoured Copper Cable.
Supply and lay Earth contunity conductor of following sizes:-
100X10mm GI flat
50X6 mm GI flat
40X6 mm GI flat
75X6 mm Copperflat
CABLE TRENCH/CABLE TRAYS.
CABLE TRAYS
Supply & Installation of heavy duty hot dipped galvanized perforated type Cable trays of following sizes, suspended from ceiling or fixed vertically on wall / column 2mm thick as per including necessary supports like anchor bolts, hangers, brackets etc. and accessories like Elbows, Bends, Tee, requisite support / suspenders, hardware etc. as per site requirement. All supporting structure & hardware including nuts & bolts etc. shall be of galvanized iron as approved. Height of cable tray will be 50 mm.
Without Cover
600 mm width perforated cable tray
450 mm width perforated cable tray
300 mm width perforated cable tray
150 mm width perforated cable tray
75 mm width perforated cable tray
50 mm width perforated cable tray
With Cover
600 mm width perforated cable tray
450 mm width perforated cable tray
300 mm width perforated cable tray
150 mm width perforated cable tray
75 mm width perforated cable tray
50 mm width perforated cable tray
Ladder trays Without cover
600 MM width Ladder cable tray
450 mm width Ladder cable tray
300 mm width Ladder cable tray
150 mm width Ladder cable tray
75 mm width Ladder cable tray
50 mm width Ladder cable tray
Steel for supporting the above Cable Trays
Supply and fixing 45W LED (with system efficacy not less than 20 lumen/watt) street light fitting made up of pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection, bracket 1.5 m long, made of 40 mm dia GI pipe, light grade, including GI clamps, nuts, bolts and washers with two coats of synthetic enamel paint over a coat of red oxide primer, input voltage range 220-240 V, including necessary electrical connections from ceiling rose to light fitting with 3 core, 1.5 Sqmm flexible copper conductor cable complete as as specified and as directed.
SAFETY ACCESSORIES : Supply and installation of following safety accessories., Pair of sand bucket (two buckets on one stand) - 7, Shock treatment chart in Hindi and English duly framed - 2, First Aid Box - 5, Enamelled Danger Boards for 11KV - 2, 3 Buckets 9Ltr. Capacity with angle Iron stand - 1, Electrical Insulating Rubber Mats for 11KV and 433V (HT and LT panels) should be of 3.0mm and 2.0mm respectively As per IS: 15652-2006 to be provided as per the requirements on site.
NOTE- (I) Earthing Strips,Running Length of Conductors in the LPS System, Cable Tray and Cable quantities measured based on the as on date Latest drawings received from the Client. It may vary based upon the Site Conditions/Equipment Locations and as per the routing at site by (+/-10%).
(II) Please note that Electrical Contractor need to consider the electrical services layout drawings of overall plant as conceptual drawing only and the electrical contractor need to furnish/prepare the final shop drawing before starting the electrical works and as built drawings after completion of the electrical works as per the site condition and exact shed area machinery/equipment/instrument location layout. Electrical Contractor is duty bound to prepare shop and as built drawings.
RAIN WATER HARVESTING
UPVC Class “3” Pipes (IS:4985) with 100 mm dia latest amendment soil waste and vent pipes jointed with solvent cement inclusive of all necessary specials like bends, tees, offsets, junctions, pan connector, cowls etc., laid under floor/under ceiling/on walls with suitable supports (threaded rods with clamps/ms angles/gripple supports) for the pipes clamps including making bores in masonry / RCC slabs etc., and rendering the bores in cement mortar after laying the pipes and specials curing etc., complete.
RCC Hume Pipes of NP2 class with suitable collars filling the recess at joints of pipes with hemp dipped in hot bitumen or other suitable compound for chalking of joint by jack, setting up of loose space over the collar joints chalked with CM 1:2, finished both ends to a slope of 1:1 including curing, testing of pipes, etc., complete of following sizes:-
200 mm dia
250 mm dia
400 mm dia
ARBORICULTURE
M&Lfor Organic mannuer filling in ground laid in layers not exceeding 15cm thick spread levelled watering for required level and gradient and slope complete all as spedified and as ditected.
Removal of weeds road pebbles etc. manually or mechanically and Clearing the area befor starting the Arboriculture work.
Supply and plantetion of Fox tail palm ( Wodyetaib Bifurcate) 9 to 10 ft length including necessay digging and application of fertilizers.
Supply and plantetion of Bouganvilla (dwarf) Hybrid variety 3 x 3ft high including necessary digging and application fertilizers.
FIRE FIGHTINING
CO2 Design, Supply and installation of a high-pressure seamless brand new rechargeable type CO2 cylinder with a water capacity of 68 liters and CO2 capacity of 45 kg, equipped with a master valve and 24 VDC solenoid for both auto and manual operation. The cylinder conforms to IS-72855 standards with a test pressure of 250 Kg/cm2 and a working pressure of 150 Kg/cm2. It holds approvals from BIS and CCOE. Max working pressure: 250 Kg/Cm2., Qty- 68 Nos With and including following items.
Design, Supply and installation of a high-pressure seamless brand new rechargeable type CO2 cylinder with a water capacity of 68 liters, ISI marked, and CCE approved to fill 45 kg of CO2 gas. The cylinder adheres to IS-72855 standards with a test pressure of 250 Kg/cm2 and a working pressure of 150 Kg/cm2. It holds approvals from BIS and CCOE. Max working pressure: 250 Kg/Cm2.,Qty- 748 Nos
Design,Supply and installation of pilot cylinders with pressure actuation, Qty -28 Nos.
Design, supply and installation of CO2 Cylinder Bank Accessories suitable for 45kg capacity CO2 cylinders, the package includes: a seamless Sch.80 pipe manifold made as per ASTM-A-106 Gr.B standards, finished with a P.O Red shade; a frame assembly equipped with holding rods and nuts for cylinder stability, powder-coated for durability with suitable holes provided for anchor fasteners for grouting; and a gas weight monitor fixing rail assembly, also powder-coated with a red shade finish., Qty - 69 Nos
Design, supply and installation of a Continuous Gas Weight Loss Monitor from reputable brands such as UFC, TRIPARULEX, or equivalents, ensuring accurate and reliable monitoring of gas consumption.", Qty - 814 Nos
Design,Supply and Installation of Remote Cylinder Weight Tracking System, Qty- 66Nos
Design,Supply and Installation of CO2 Discharge, Qty - 650 Nos.
Design,Supply and Installation of Non-Return Valve for CO2 Cylinder. Qty - 814 Nos.
Design,Supply and Installation of 1/2" High-Pressure Hose from Cylinder Manifold, Qty - 814 Nos.
Supply and Installation of 1/4" High-Pressure Hose from Valve to Pneumatic Head, Qty- 748 Nos.
Design,Supply and Installation of Primary Adapter for Cylinder, Qty- 66 Nos.
Design,Supply and Installation of Provision of Conventional Heat Detector (Probe Type with FP Junction Box), Qty - 1200 Nos.
Design,Supply and Installation of Gas Release Control Panel with Backup Battery., Qty - 5 Nos.
Supply and Installation of Manual Gas Release Unit - Weatherproof, Qty - 5 Nos.
Supply and Installation of CO2 Discharge Pressure Sensor, Qty - 5 Nos.
Supply and Installation of Safety Outlet for Manifold, Qty - 5 Nos.
Supply and Installation of Hand-operated suppression mechanism-WP, Qty - 5 Nos.
Supply and Installation of auditory alarm device, Qty - 5 Nos.
Supply and Installation of Audible and Visual Alert System., Qty - 5 Nos.
Supply and Installation of Schedule 40 seamless piping system including elbows, tees, reducers, and other fittings., Qty - 10 Nos
Supply and installation of 2 x 1.5 sq mm cu conductor cable with glands., Qty - 10 Nos
Design, Installation, Testing and Commissioning Charges, Qty - 5 Nos
Portable Fire extinguishers for other areas
Supply and Installation of DCP Cartridge type Fire Extinguisher 6Kgs. capacity bearing ISI Mark for Fighting BC Class of Fire. The Extinguisher will be Manufactured Strictly as per IS: 15683 bearing ISI Mark with floor mounting stand. Minimum fire rating should be 6A, 183B with MAP 90% , Qty- 16 Nos.
Supply and Installation of Co2 type Fire Extinguisher 4.5 Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Squeeze Grip type valve with initial Charge as per IS: 15683:2006 specification, bearing ISI Mark with floor mounting stand. With minimum fire rating 55B. Qty - 2 Nos.
Supply and Installation of Co2 type Fire Extinguisher 9Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Squeeze Grip type valve with initial Charge as per IS: 15683:2006 specification, bearing ISI Mark with floor mounting stand. With minimum fire rating 55B, Qty- 36 Nos.
Hydrant network- piping & Accessories
supply and installation of MS pipe 'B' class, complete with requisite fittings, precise cutting, and fabrication as per provided drawings
150 mm dia Approximate , Qty- 300 RM.
100 mm dia Approximate , Qty- 180RM.
80 mm dia Approximate , Qty- 90 RM.
supply and installation of wrapping and coating solutions tailored for underground pipes with an approximate diameter of 150mm, ensuring long-lasting protection against corrosion and environmental factors, Qty- 300 Mtr.
Supply and Installation of SS Double Hydrant valve 63mm dia coupling ISI mark With nut bolt, flange, gasket, tee, angle, etc. , Qty- 6 Each.
Supply and Installation of SS Single Hydrant valve 63mm dia coupling ISI mark With nut bolt, flange, gasket, tee, angle, etc., Qty- 14 Each.
Supply and Installation of RRL hosepipe 15mtr. Long with male-female coupling winded ISI mark., Qty- 40 Each.
Supply and Installation of Branch pipe with nozzle 63mm dia, ISI mark., Qty- 20 Each.
Supply & fixing of wall mounting swing type first aid fire hose reel with drum (30 Mtr) With "1" Inch Ball valve, Qty- 20 Set.
Supply and Installation of weather proof fire hose cabinet for keeping 2 no. RRL hose & branch pipe standard size, Qty- 20 Each.
Supply and installation of SS four way fire brigade inlet., Qty- 2 Set.
Supply & fabrication of steel support for piping along with wall side include grouting/ anchorfastner., Qty- 1 Tone.
SITC of GM Air Release Valve 25.**Manufacturer certificate with serial number to be provided, Qty- 4400 Nos.
FIRE EXTINIGUSHERS
Supply and install in position approved make ABC Stored pressure type Fire Extinguisher 6 Kgs Modular Fire Extinguishers Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher is manufactured strictly as per IS: 15683:2006 with ISI mark. FIRE RATING 4A 55B, Qty- 48 Nos.
supply and installation of 9-liter Water CO2 Stored Pressure Type fire extinguishers, equipped with a controllable discharge mechanism, suitable for Class A fire ratings (2A), and bearing the ISI Mark IS 15683 for assured quality and compliance.", Qty- 12 Nos.
Foam 9 Ltrs capacity Fire Extinguisher for Transformer Yard and DG Yard., Qty- 1 Nos
Supply and install in position approved make Co2 type Fire Extinguisher 4.5 Kgs Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with 1 metre length Wire Braided Discharge hose and horn and Wheel type (ISI Approved) valve with wall bracket and with initial Charge as per IS: 15683-2006specification, bearing ISI Mark. FIRE RATING 21B, Qty- 48 Nos.
FIRE ALARM & DETECTION
Supply, Installation, testing & Commissioning of Microprocessor based Analogue addressable fire alarm control panel. panel shall have below specifications: 1) Combination of 120 Detectors & Devices per SLC loop. 2) expandable up to min. 1loops. 3) Minimum 40 x 4 Characters LCD display. 4) Networkable - Modules shall be considered ( OFC/copper ) 5) Auto Dialer upto 5 numbers. ( vendor shall consider the auto dailer ) 6) Auto Programming Day and Night Mode 7) Enable and Disable function 8) FM Approved. 9) Advanced user friendly programming software including ‘Fuzzy Logic’. Operates on 120 to 220V AC, 60 / 50 Hz. Operating Temperature 0°C- 49°C /95% relative humidity RH (non-condensing) . Built-in Alarm, Trouble, Security, and Supervisory relays, with 24Hrs Normal Condition 1Hrs Alarm Condition battery backup & mounting accessories as per site conditions. Quote rate shall be included required network/communication modules. Scope of work includes cutting the false ceiling, drilling the holes, laying the cables as per site conditions etc.
Supply Installation, Testing & Commissioning of Analogue Addressable type Optical Smoke & Heat Detectors(Multisensor) with required mounting base and back box, FM Approved
Supply, Installation, Testing & Commissioning of Addressable pull type Manual call point /resettable which is used for manually trigger a fire alarm suitable for interconnecting to the loop technology directly. ( No break glass type). FM Approved
Supply, Installation, Testing & Commissioning of Sounder cum strobes multi tone sounder. FM Approved
Supply, Installation , Testing & Commissioning of Addressable Control Modules with required battery backup and Power Supply Units. With required back box. FM Approved
Supply, Installation , Testing & Commissioning of Addressable Monitor Modules.(for third party integration) . With required back box. FM Approved
Supply, Installation , Testing & Commissioning of Fault Isolator Module with required back box. FM Approved
Supply& Fixing of Response Indicators, Local Approved
Supply & laying of 2 core x1.5 Sq.mm FRLS Cu conductor Armoured shielded type fire rated low smoke multi-stranded, copper conductor cable.(includes termination and testing of loop into device) approx. quantity only. Actuals as per site conditions. ( for loops & Hooters )
Supply & laying of 3 core x1.5 Sq.mm FRLS Cu conductor Armoured shielded type Power cable multi-stranded, copper conductor cable.(includes termination and testing of loop into device) approx. quantity only. Actuals as per site conditions. ( for control modules/FZM )
Short wave length laser-Based Absolute Smoke Detection system with 1 pipe inlets, 500 m2 coverage; Wide sensitivity range - 0.001%–20% obs/m; 4 alarm levels ; High efficiency aspirator; Clean air barrier optics protection; Easy to replace dual stage filter with memory; 7Nos of inbuilt potential free relay outputs;supports linear pipe length of 50m per pipe (total 100m) or branched pipe up to 50m per pipe; supports 20 Nos of EN54 Class A sampling points, AutoLearn for automatic setup of alarm threshold, Referencing & Event log; TCP/IP, WiFi & VESDANet connectivity for central monitoring & monitoring of Andriod/iOS tablets/smartphones. The panel shall have Automated Pipe Cleaning technlogy. Approvals-UL, ULC, FM, ActivFire, VdS, CE , EN54-20.
Short wave length laser-Based Absolute Smoke Detection system with 2 pipe inlets, 2000 m2 coverage; Wide sensitivity range - 0.001%–20% obs/m; 4 alarm levels ; High efficiency aspirator; Clean air barrier optics protection; Easy to replace dual stage filter with memory; 7Nos of inbuilt potential free relay outputs;supports linear pipe length of 100m per pipe (total 400m) or branched pipe up to 130m per pipe; supports 80 Nos of EN54 Class A sampling points, AutoLearn for automatic setup of alarm threshold, Referencing & Event log; TCP/IP, WiFi & VESDANet connectivity for central monitoring & monitoring of Andriod/iOS tablets/smartphones.The panel shall have Automated Pipe Cleaning technlogy. Approvals-UL, ULC, FM, ActivFire, VdS, CE , EN54-20.
Short wave length laser-Based Absolute Smoke Detection system with 4 pipe inlets, 6000 m2 coverage; Wide sensitivity range - 0.001%–20% obs/m; 4 alarm levels ; High efficiency aspirator; Clean air barrier optics protection; Easy to replace dual stage filter with memory; 7Nos of inbuilt potential free relay outputs;supports linear pipe length of 100m per pipe (total 600m) or branched pipe up to 130m per pipe; supports 100 Nos of EN54 Class A sampling points, AutoLearn for automatic setup of alarm threshold, Referencing & Event log; TCP/IP, WiFi & VESDANet connectivity for central monitoring & monitoring of Andriod/iOS tablets/smartphones, The panel shall have Automated Pipe Cleaning technlogy. Approvals-UL, ULC, FM, ActivFire, VdS, CE , EN54-20.
Sampling Hole Kit which consist of PVC pipe fitting ( Tee ) with 10mm dia built in hole to suck the air.
PVC/UPVC/CVPC/ABS Plastc End Cap for large bore pipes, 25 mm
EN approved power supply unit with 110/230VAC input and 18 to 29VDC output. The power supply unit has the following indications: OK - Green LED and Fault - Yellow LED, shall be installed at Aspiration panel.
Sampling Pipe - 25mm OD, 18 to 21mm ID smooth bore PVC/UPVC/CVPC/ABS Plastc Pipe
Software based Air flow calculation shall be run to verify the Transport Time from the farthest sampling point of the zone to Aspiration panel. ( Ensure that the Transport Time shall not more than 120 Sec )
Supply, install, testing, commissioning and configuration of Aspiration system central monitoring station to monitor the all the field aspiration panels at control room which consist of suitable Workstation with 21 inc monitor, key pad, wired mouse pre loaded latest OS, i5 processor, 1TB SSD, 8GB Ram, Pre loaded Central monitoring software, the sofware supports upto 20 field panel and user firendly. The required Ethernet Communication cable with conduit & Network switch from field panels shall be considered.
LIGHTNING PROTECTION SYSTEM
8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination and down conductor system . Cross sectional area of conductor should be 50 mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.034 µm, c.Tensile strength - 178 MPa or N/mm² d. Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2.
Nylon Conductor Holder for Parapet wall for holding 8 mm dia Aluminium alloy round Conductor.
Nylon roof conductor holder for flat roof with concrete block for fixing 8 mm dia Aluminium alloy Solid Round Conductor in the terrace flat surface at every 1 mtr.
Stainless steel 304 Grade Cross Connector for 8 mm dia Aluminium alloy round conductor & 10 mm Copper bonded conductor at cross/Tee junction. Test Parameter a) Mechanical Load b) Electrical Test c) ENvironmental Test Tested for IEC 62561-1
Expansion Joint with connector to compensate the expansion and contraction of 8mm dia Solid Round Al. Conductor during temperature variations. Expansion Joint should be consider at every 20 mtr length of straight horizontal air termination and connected at both the end with use of straight connector conductor.
Supply Installation of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305. Test Parametres: a) Mechanical Load b) Electrical Resistivity c) Environmental Test Tested as per IEC 62561-1
VAT 2mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends (Tappered Type). The rod shall be mounted with stainless steel clamp and fixing accessories . Test Parameter for 2 mtr vertical air terminal a)ELectrical Resistivity b) Tensile Strength c) Condition of Salt Mist Tested as per IEC 62561-2. Test Parametrer for Wall clamp a) Mechanical load as per IEC 62561-1
VAT 2 mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends(Tappered Type). The rod shall be mounted with stone and fixing accessories . Test Parameter for 2 mtr vertical air terminal a)ELectrical Resistivity b) Tensile Strength c) Condition of Salt Mist
VAT 6mtr length of material AlMgSi of diametre ø 40/22/16/10 mm crimped on both the ends(Tappered Type). The rod shall be mounted with stainless steel stand and fixing accessories . Test Parameter: Mechanical Load Test for individual aluminium alloy rods - 120 to 280 N/mm² Salt Spray Test-No sign of corrosion Tested as per IEC 62561-1&2
Stainless steel SS 304 Grade Folding Clamp as per sheet profile for 8 mm dia Aluminium alloy Solid Round Conductor for horizontal Air terminal above metal sheet to meet the requirements for IS/IEC 62305. Test Parameter: a) Mechanical Load b) Environmental Test Tested as per IEC 62561-4
DOWN CONDUCTOR SYSTEM
8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination and down conductor system . Cross sectional area of conductor should be 50 mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.034 µm, c.Tensile strength - 178 MPa or N/mm² d. Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2.
Nylon Conductor Holder for Parapet wall for holding 8 mm dia Aluminium alloy round Conductor.
Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305. Test Parametres: a) Mechanical Load b) Electrical Resistivity c) Environmental Test Tested as per IEC 62561-1 CAPE Type : CJ 8
Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6.
Stainless Steel 304 grade Test Joint with enclosure to interconnect between 8 mm Al. round conductor to 10 mm copper bonded round conductor. Test Parameter: Salt Spray Test for test joint plate -No sign of Corrosion Tested as per IEC 62561-1 CAPE Type : TJRRE-G1
EARTHING SYSTEM
10 mm copper bonded Solid Steel Round Conductor with minimum coating thickness 70µm as integrated down conductor. Material should be tested Tensile strength, Electrical Resistance, salt mist, Bend & Adhesion to meet the requirements of IS/ IEC 62305 and IEC 62561-1&2.
Stainless steel SS 304 Grade Conductor Holder for fixing the 8 -10 mm dia round conductor on the wall . Test Parameter: a) Mechanical Load b) Environmental Test Tested as per IEC 62561-4
Supply Installation of CAPE make UL Listed Maintenance Free Copper bonded Earth rod of 3048mm length having the dia of 14.2 mm with copper coating thickness of 254 microns. The rod has been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2 & UL 467. Supply Installation of Earth enchancing mineral compound tested for leaching and TCLP with NABL accredited Lab as per IEC 62561-7 Supply Installation of Supply of CAPE make Earth rod clamp made for terminating cable. Supply Installation of Connecting point made of stainless steel for terminating 10mm dia copper conductor. Supply Installation of Earth Chamber Inspection Pit made up of Plastic withstand load of 60kN
LIFT Supply, Installation, Testing, Commissioning of Goods lift, 4 stops, encompassing with Capacity: 4 tons Speed: 0.5 meters per second Power Supply: 415 volts, 3 phase AC, 50 Hz Drive System: Single-speed motor with AC Variable Voltage and Variable Frequency Drive (VVVF drive) Compliance: Conforms to IS-14665 standards and amendments, components, safety features, installation process. centre opening stainless steel doors with electric motor-driven mechanism, Sliding stainless steel doors for enhanced durability and safety, Automatic rescue device (ARD) system for emergency situations, 3D infrared sensor integrated into the full height of the door for safety. Simplex automatic and manual dual-controlled operation, Optional attendant mode for manual operation, Built-in announcing system without a handset in the lift car, machine room, and ground floor landing door, Overload protection to prevent exceeding the lift's capacity, Emergency stop button for immediate halting of operation, Fire-resistant construction materials and components, Battery backup system to ensure operation during power outages, Emergency lighting and alarm system for evacuation procedures. (Lift door height should be 2.4 M)
EOT Design, Supply, Installation, Testing and Commissionoing OF double girder EOT crane,20 ton with Long Travel 37210mm with long travel rail size 60 * 40 MS Bright Bar. Of span 17080mm, Height of hook lift 8500 mm, for Indoor location, with class of duty M5, Hoist Speed : 3.8/ 1.3 m/ Min(VDF), Cross Travel Speed: 20/ 5 m/ Min(VDF), Long Travel Speed: 20/ 5 m/ Min(VDF), Hoist Motor: 18.5 KW, Cross travel motor: 0.75 KW * 2Nos, Long travel motor: 1.15 KW * 2Nos, End carraige wheel base 4000mm, Supply voltage 415v, Control Voltage 110v, Crane Weight: 16300kg(apprx weight), Max wheel Load without impact : 14375 kg (Apprx) including Pendants, Push bottom, Copper DSL, Power cable for Panel to DSL, and suitable MCCB and panel complete all as spcified an directed.
WATER COOLER Supply and installation of 2KVA Air Cooled Servo Controlled Voltage Stabilizer(SCVS) with Input: (170-270) V , Output: 230 V , Type of Colling: Air Cooled, Indoor Type: IP 20.
AC PLANT
Supply, Installation, Testing and commissioning of water coolled VFD SCREW Chiller of the capacity net 175 TR at operating conditions as specified with refrigerant R 134a packaged type Water cooled variable frequency drive (VFD) screw chillers ( Part load details as per IPLV & NPLV FOR AHRI CONDITIONS AND ACTUAL CONDITIONS AT CONSTANT CONDENSER WATER TEMPERATURE WITH AHRI RELIF to be provided along with the tender documents) including its drive motors , water cooled Shell & Tube condensors, expansion device shell and tube type evaporator with enhances surface seamless copper tubes and removable water heads, suitable capacity squirrel cage induction motor, sensing elements for HP/LP/Anti- freeze etc. complete all as required at site, refrigerant piping fitting, all valveas and acesssores to required interconnected pressure, condenser, chiller and expansion valves, intial/first carge of refrigerant gas and compressor oil, chiller sound level should be less than 70 dBA @ 1m of else suitable sound reduction treatment, Mounting frame with RCC/Cement concrete foundation and accessories all as per site requirment, Refrigerant piping shall be fatory assembled as per specifications/OEM,(Make : Carrier /Blue star/ Voltas/Trane /Diakin) , micro processor control with RS-485 port,nessary operational and safety devices, flow switches, victaulic couplings at the following conditions. chilled water inlet temp is 52.8˚ F and outlet temp is 42.8˚ F ,Fouling Factor 0.0005 ft2/h/°F/BTU for Chiller & Condenser water inlet temp 87.44˚F and outlet temp 97.52˚F,Fouling Factor 0.001 ft2/h/°F/BTUas per specification. (2W+1S)- Qty-03
Coordination with Chiller Supplier / Installer for installation, testing and commissioning of WATER AND AIR COOLED CHILLERS CO-ORDINATION - 3 also ensure that interconnections, piping and cabling are carried out as per BOQ and specifications to enable seamless integration between Chillers & low side work- Qty 03 (lot)
CHILLED WATER & CONDENSOR PUMPS
Design, Supply, installation, testing and commissioning of centrifugal End Suction Long Coupled Top Discharge Chilled Water Primary Pumps with high efficency (EFF#1) electric drive motor, as per technical specifications (impellers and wearing rings made of bronze, priming funnel and air purging provision with valves and with necessary grouting, foundation bolts, etc.) including customs clearance and transportation to site. Inertia base Foundation for pumps shall be carried out by hvac contractor until or unless stipulated else where otherwise. All pumps shall be mounted with necessary vibration isolators. Each Pump capacity shall be 420 USGPM @ 15 mt. head as per specifications and approved drawings (2working + 1 stand by) - QTY -3
Design, Supply, installation, testing and commissioning of centrifugal End Suction Long Coupled Top Discharge Chilled Water Secondary Pumps( VARIABLE SPEED) with high efficency (EFF#1) electric drive motor, as per technical specifications (impellers and wearing rings made of bronze, priming funnel and air purging provision with valves and with necessary grouting, foundation bolts, etc.) including customs clearance and transportation to site. Inertia base Foundation for pumps shall be carried out by hvac contractor until or unless stipulated else where otherwise. All pumps shall be mounted with necessary vibration isolators. Each Pump capacity shall be 420 USGPM @ 25 mt. head as per specifications and approved drawings (2 working + 1 standby ) -QTY -3
Design, Supply, installation and testing and commissioning of centrifugal End Suction Long Coupled Top Discharge Condenser water Pumps with high efficency (EFF#1) electric drive motor, as per technical specifications impellers and wearing rings made of bronze, priming funnel and air purging provision with valves and with necessary grouting, foundation bolts, etc. including customs clearance and transportation to site. Inertia base Foundation for pumps shall be carried out by hvac contractor until or unless stipulated else where otherwise. All pumps shall be mounted with necessary vibration isolators. Each Pump capacity shall be 700 USGPM @ 15mt. head as per specifications and approved drawings (2working + 1 stand by)-QTY -3
VARIABLE FREQUENCY DRIVES & LOGIC CONTROL PANEL:
Supply, Installation, Testing & Commissioning fo variable speed pumping system comprising of following accessories. The system shall be complete in all respects including electrical components for motor of primary chilled water pumps. Each pump shall have an independent adjustable frequency drive. Common Panel with suitable controller to control 4 Nos. Pumps separately. as per specs and drawing. Including sensor, transmiter, control wiring etc complete in all respect. It shall be also BMS compatible. Panel should be IP 55 Rated. For Secondary chilled water pumps. Variable frequency drive (VFD) : 3Nos Micro processor based pump controller : 1 No Software down loaded in pump controller : Job Control wiring : Lot Variable speed pumping system described above-QTY -1
QTY -1 Supply Installation Testing and Commissioning Dirt separator , it shall be of a solid and robust construction (Mild Steel). It shall be able to remove solid particles upto 5 microns from water at Velocity between 2-3m/s. All connections, fittings and heads shall be of carbon steel. The medium used to de-aerate and remove dirt shall be manufactured of Steel Tube & a mesh made of copper wire. This medium should be non clogging in nature. The flow should not be obstructed by the dirt collected. A Drain valve should be present at the bottom to remove the accumulated dirt without the need of shutting down the operation of the system. The Dirt Separator shall be insulated depending upon its location (outdoor or indoor). The pressure drop on account of the dirt separator shall not exceed 21 kPa at maximum flow of the chilled water system.and also as per the tender Specifications.
PRESSURIZATION SET
Supply, Installation, Testing and Commissioning of Insulated Pressurisation Unit (1000 L)of requisite capacity with necessary makeup, quick fill, drain and over flow connection, valves, fittings, suitable rating pump,expansion vessel (1000 L), necessary pump connection along with valves,stariner and compleate panel etc. The closed expansion tank will be of M.S. construction with interchangeable EPDM-BUTYL rubber membrane. The expansion tank shall be complete with safety relief valve, pressure reducing valve and pressure gauge. The tank will be of pressure rating to suit the system pressure and will be sized to adequately compensate for water expansion due to operating temperature variations. The tank shall be fabricated as per IS 2825-1969 for “non-fired pressure vessels” and the flanges shall be as per IS 6392-1971. For chilled water application, it will be insulated with 50mm thick insulation to the specifications and cladded with 26G-aluminium cladding. The expansion tank shall be supplied along with pressurization unit. Pressurization unit shall be with 2 nos. (1 working + 1 stand by) horizontal/vertical multi-stage pumps of suitable rating & capacity, as indicated hereunder, factory mounted on a steel frame along with interconnected piping, valves, strainer, pressure gauge, pressure transmitter, flow meter to measure the make-up water quantity, control panel with duty cycling and dry-run protection, electrical relays/contactors and interconnecting wiring: Protection - IP55 ,Insulation class - F ,Liquid temperature range - 0°C - 50°C The unit shall be capable of Pressurising the system to the required pressure with suction from a break-tank located at least 1m above pump level. The control unit shall be housed in a metal box, IP 54 protection with BMS compatibility via an RS485 cable interface. All pump's shall be mounted with necessary vibration isolators, etc. as per the specifications and approved drawings -QTY -1
Supply of the chiller plant manager system shall have the capability to monitor and control chillers, primary,Secondary ,condenser water pumps, cooling towers and motorized valves to provide the chiller plant operator with control, monitoring, and management information as per the IO summary and tender spec. Water cooled Chiller's to be controlled - 3 No's No. of primary pumps: 3 No’s No. of Secondary pumps: 3 No’s No. of Condensor pumps : 3 No’s No. of Cooling towers: 3 No’s Management of hydronic units : Yes Regulation on two water circuits : Yes User interface with display and commands : Yes- QTY -1
Automatic Tube Cleaning system :- Supply Installation Testing and Commissioning of Automatic Tube Cleaning system (Ball Type) having common controller for monitoring and operating 80CS for 3 Nos chillers with ancillary components and touch screen controller plc Panel for automatic operation.It shall consist of Ball trap,Ball collector,Ball injection,Collection skid consisting of seperate injection pumpsp with motors,seperate collection pump with motors,necessary electrical operated motorised control valves,control panel with PLC and HMI on the control panel- multicolor seventh touch screen type long end manual ball valves ,pressure gugaes,Cleaning sponge balls etc. qty : 3Sets Chillers ,Supply , Supply Installation Testing and Commissioning HDPE Water tank of suitable capacity not less than 5000Liters ISI Marked( 3 layers,Cylindrical,Vertical with closed top) complete with inlet,Outlet and overflow connection and float valves etc.including GI pIPE medium grade complete with fitting valves etc.for connecting cooling tower sump and storage tank as required and specified.l. Note Necessary Platform for make up water tank and connected pipes and piping shall be dwmed to be included in the rate quoted in above items -QTY -2
AIR HANDLING UNIT
QTY -4(NOS) 7100CFM / 30TR(ASRS ROOM) @ 80mm TSP
QTY -3 (NOS)8350CFM / 30TR(PROVIDER ROOM) @ 80mm TSP
CEILING SUSPENDED UNITS:
QTY -1(NOS)16.0 TR / 2400 CFM@ 50mm TSP .
QTY -4(NOS) 8.0 TR / 3200 CFM@ 50mm TSP .
QTY -1 (NOS) 10.0 TR / 4000 CFM@ 50mm TSP .
QTY -1 (NOS) 12.0 TR / 4800 CFM@ 50mm TSP .
QTY -6 (NOS) 15.0 TR / 6400 CFM@ 50mm TSP .
CASSETTE UNITS:
Design,Supply, installation and testing and commissioning of Chilled water Cassette Units with 3.0TR (4WAY), 3 speed having coil section, blower section, filter section, condesate drain pump, insulated and extended drain tray, supports, copper piping connections&Unions, Incoming cable from MCB/ Isolator to unit , 12-24V Step down transformer for PIBC Valve Actuators, etc. Extended tray should accommodate ball valves, PIBC motorised valves, etc. . Digital Thermostat with remote sensing element with Cassette unit switch on/off control , compatable to the PIBC valve to control the room temperature to be included.Noise level of fan coil unit shall be less than 35 dBA as per the specifications and approved drawings-QTY -1
CALORIFIERS (HOT WATER GENERATOR)
Design, Supply installation testing and commissioning of 30KW capacity galvanised steel shell with removable electric water element of min 30KW, designed for inlet temp of 60deg C and 70 deg C water out let with nessary fittings, valves, mounting brakets with minimum 15 minutes storage as per specification-QTY -6
HOT WATER PUMPS
Design, Supply, installation and testing and commissioning of Horizontal Multistage monoblock Centrifugal pump with necessary grouting, foundation bolts, etc. including customs clearance and transportation to site, testing and commissioning of constant speed hot water pumps. Each Pump capacity shall be 30 USGPM @ 15 mt. head, mounted on frame with factory fitted nessary fittings, valves, pressure guages, header, control panel and expansion tank (100 L) as per specification (1 working + 1 stand by)-QTY -6
HOT WATER PIPES
Supply, Installation, Testing and Commissioning of MS 'C' Class hot water pipe with Ø 50 mm, fittings, flanges, valves,reducers ,sockets for probe meter, support hangers with vibration isolation hanger etc with Supply, Installation, Testing and Commissioning of chilled water pipe insulation with 44mm thick closed cell elastrometric nitrile rubber of density 43 Kg/m3, Thermal conductivity not exceeding 0.035 W/M°K Class 1, fire performance to pass class 1 as per BS 476 part 6& class O as per BS 476 part 7 & use recommended adhesive. the insulation finished with treated woven glass fiber reinforced covering & further finished with 24G Aluminium cladding as per the specifications and approved drawings-QTY -1 Lot
AIR DISTRIBUTION SYSTEM:
Supply, Installation, Testing and Commissioning of factory fabricated Box type GSS Ducting ( with minimum 120 Gms /Sqm zinc coating) as per SMACNA/DW standards with splitters,bends, elbows, vanes, supports,neoprene of minimum 6mm thick gasket, duct sealant (to be applied in all corners & joints), nuts, bolts, angle iron flanges, ect. GI full threaded rods hung to minimum 12 mm dia HILTI make anchor fastner as required and Pre painted slotted rail supports, as per the specifications and approved drawings.
QTY -01 Lot 24G (0.6 mm thick)
QTY -01 Lot 22G (0.8 mm thick)
QTY -01 Lot 20G (1.0 mm thick)
QTY -01 Lot 18G (1.2 mm thick)
INSULATION:
Supply, Installation, Testing and Commissioning Thermal Insulation of Supply air ducting /Return for Indoor with 19mm thick closed cell elastrometric Nitrile rubber with of density minimum 43Kg/m3, FM approved and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and covered with 7 mil thick chemically treated woven glass cloth having density 205+/- 10 g/sqm and affixed using synthetic contact adhesive of approved make and protective coating of starbond 30-36 all as per the specifications and approved drawings -QTY -01 Lot
Supply, Installation, Testing and Commissioning of Under deck insulation type of a 25mm thick non fibrous ,closed cell , Elastometric Nitrile Rubber with factory laminated aluminium foil of density minimum 43 kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7& class O as per BS 476 part 6 and fixed to roof slab using recommended adhesive / SR Fevicol 505 grade and fastened using 26g chicken wire mesh and 2"x2" GI washers and joints sealed with tape as per the specifications and approved drawings - QTY -01 Lot
Supply & Installation of Duct Accoustic Insulation (for initial 5 meters )applied inside of the duct work with 10mm thick Open cell Nitrile Rubber fixed using sticker pins and GI washers. Material density minimum of 150 kg/m3 & The material should conform to Class 1 rating for surface spread of Flame as per BS 476 Part 7, as per the specifications and approved drawings-QTY -01 Lot
DAMPERS, GRILLES & DIFFUSERS:
Supply, Installation, Testing and Commissioning of Opposed type GI Zero leakage Volume Control dampers with matching flanges of sizes as per specification and approved drawings-QTY -01 Lot
Supply, Installation, Testing and Commissioning of Fire dampers with fusible links with frame etc for supply. Rated for 2 hours (Dampers should be of wall / duct mounted) as per specification and approved drawings.
QTY -01 Lot Up to 0.5 Sqmt
QTY -01 Lot 0.51 to 1 Sqmt
Supply, Installation, Testing and Commissioning of Extruded Al. Powder coated Continous grill / Discrete grills for supply/ Return air as per the specifications and approved drawings. (Colour to match the false ceiling as per the Client/ Consultant approval)
QTY -01 Lot 250MM Ht
QTY -01 Lot 150MM Ht
Supply, Installation, Testing and Commissioning of Extruded Al. Powder coated Diffusers for Supply/ Return air, as per the specifications and approved drawings.(Colour to match the false ceiling as per the Client/ Consultant approval) -QTY -01 Lot
)Supply, Installation, Testing and Commissioning of Al. Collar dampers, as per the specifications and approved drawings.(Colour to match the false ceiling as per the Client/ Consultant approval) -QTY -01 Lot
Supply, Installation, Testing and Commissioning of weather proof extruded aluminium powder coated fresh air louver of non vision type of Perforated Al net, VCD etc as per the specifications and approved drawings-QTY -01 Lot
Supply, Installation, Testing and Commissioning of Extruded Al. Powder coated Toilet Exhaust Grills , as per the specifications and approved drawings.(Colour to match the false ceiling as per the Client/ Consultant approval) -QTY -01 Lot
CHILLED WATER PIPING WITH INSULATION, VALVES AND ACCESSORIES:
INSIDE CHILLED WATER PIPE INSULATION of 32mm thick for inside piping with closed cell elastrometric nitrile rubber of density 43 Kg/m3, Thermal conductivity not exceeding 0.035 W/M°K Class 1, fire performance to pass class 1 as per BS 476 part 6& class O as per BS 476 part 7 & use recommended adhesive / SR Fevicol 505 grade and Insulation covered with 7 mil thick chemically treated woven glass cloth having density 205+/- 10 g/sqm and affixed using synthetic contact adhesive of approved make and protective coating of starbond 30-36 ,as per the specifications and approved drawings.
QTY -01 Lot Ø 300 mm
QTY -01 Lot Ø 250 mm
QTY -01 Lot Ø 200 mm
QTY -01 Lot Ø 150 mm
QTY -01 Lot Ø 125 mm
QTY -01 Lot Ø 100 mm
QTY -01 Lot Ø 80 mm
QTY -01 Lot Ø 65 mm
QTY -01 Lot Ø 50 mm
QTY -01 Lot Ø 32 mm
QTY -01 Lot Ø 25 mm
Supply, Installation, Testing and Commissioning of balancing (Manual) with Ø 150 mm, matching flanges , bolt, nuts, Nitrile rubber insulation with GC cloth and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with (24G Aluminium cladding for Exposed), all etc., complete as per specifications and approved drawings -QTY -01 Lot
Supply, Installation, Testing and Commissioning of butterfly / isolation valve'swith matching flanges , bolt, nuts,Nitrile Rubber insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with 24G Aluminium cladding for Exposed , all etc., complete as per specifications and approved drawings.
QTY -01 Lot Ø 200 mm
QTY -01 Lot 150 mm
QTY -01 Lot Ø 125 mm
QTY -01 Lot Ø 80 mm
QTY -01 Lot Ø 50 mm
QTY -01 Lot Ø 40 mm
Supply, Installation, Testing and Commissioning of Motorised butterfly valve's (IP55)with Ø 150 mm (chiller), actuator ,mating flanges, bolt, nuts, insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with 24G Aluminium cladding, all etc., complete as per specifications and approved drawings-01 lot
Supply, installation, testing & commissioning of PRESSURE INDEPENDENT BALANCING CUM CONTROL VALVE with spring return , matching flanges,necessary digital thermostat And control wiring bolt, nuts, insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering etc., complete as per specifications and approved drawings.
QTY -01 Lot Ø 80 mm (for AHU )
QTY -01 Lot Ø 50 mm
QTY -01 Lot Ø 40 mm
Supply, Installation, Testing and Commissioning of Y Strainers consisting of magnetic screen , bolt, nuts, insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with 24G Aluminium cladding, all etc., complete as per specifications and approved drawings.
QTY -01 Lot Ø 150 mm
QTY -01 Lot Ø 80 mm (for AHU )
QTY -01 Lot Ø 50 mm
QTY -01 Lot Ø40 mm
Supply, Installation, Testing and Commissioning of flexible connections (Bellows)suitable for working pressure of PN16. as per the specifications and approved drawings.
QTY --01 Lot Ø 150 mm (for pumps & CHILLER )
QTY --01 Lot Ø 80 mm (for AHU )
QTY --01 Lot ) Ø 50 mm (for CSU )
QTY --01 Lot Ø 40 mm (for CSU )
CONDENSER WATER PIPING WITH VALVES AND ACCESSORIES:
Supply, Installation, Testing and Commissioning of MS 'C' Class conforming to IS -1239(pt-1) Equvavalent to BS-1387, Condenser water pipe with fittings, flanges, valves, reducers, sockets for probe meter, support hangers with vibration isolation hanger, including painting, etc for condenser water piping without insulation as per the specifications.
QTY -01 Lot Ø 350 mm
QTY -01 Lot Ø 300 mm
QTY -01 Lot Ø 250 mm
QTY -01 Lot Ø 200 mm
QTY-01 Lot Ø 150 mm
QTY-01 Lot Ø 125 mm
QTY- 01 Lot Ø 100 mm
QTY-01 Lot Ø 80 mm
QTY-01 Lot Ø 65 mm
QTY-01 Lot Ø 50 mm
QTY-01 Lot Ø 32 mm
QTY-01 Lot Ø 25 mm
Supply, Installation, Testing and Commissioning of balancing (Manual) with QTY-6(NOS) 250 mm dia (chiller), matching flanges , bolt, nuts, insulation and suitable for working pressure of PN16. as per the specifications and approved drawings.
Supply, Installation, Testing and Commissioning of Motorised butterfly valve's QTY-3(NOS) (IP55)with actuator ,mating flanges, bolt, nuts, insulation and suitable for working pressure of PN16. , all etc., complete as per specifications and approved drawings.
Supply, Installation, Testing and Commissioning of butterfly / isolation valve's with matching flanges , bolt, nuts, insulation and suitable for working pressure of PN16 as per the specifications and approved drawings.
QTY-01 Lot 250 mm dia ( cooling tower & condenser pumps)
QTY-01 Lot 200 mm dia ( cooling tower & condenser pumps)
QTY-01 Lot150 mm dia ( cooling tower & condenser pumps)
QTY-01 Lot100 mm dia ( Condenser Equiliser Line)
QTY-01 Lot 80 mm dia ( For Flush/Circulation)
QTY-01 Lot 65 mm dia ( For Flush/Circulation)
QTY-01 Lot 50 mm dia ( Make up water & Drain)
QTY-01 Lot 40 mm dia (Cooling Tower Quick Fill /Make Up)
Supply, Installation, Testing and Commissioning of Y Strainers consisting of magnetic screen ,insulation & matching flanges and suitable for working pressure of PN16 ,as per the specifications and approved drawings.
QTY-3(NOS)250mm dia ( Condenser Pumps)
Supply, Installation, Testing and Commissioning of Non return valves with matching flanges , bolt, nuts, insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with 24G Aluminium cladding, all etc., complete as per specifications and approved drawings. .
QTY-3(NOS)250 mm ( Condenser Pumps)
Supply, Installation, Testing and Commissioning of flexible connections (Bellows) and suitable for working pressure of PN16 as per the specifications and approved drawings.
QTY-6(NOS)250 mm ( Condenser Pumps )
QTY-4(NOS)200 mm (Condensor unit)
Supply & Installation of other accessories:
QTY-80(NOS)6 inch dia dial type thermometers with thermowell and mounting box. as per the specifications and approved drawings.
QTY-92(NOS) 6 inch dia dial type pressure gauge with isolating gate valve / cock with insulation (Chillers, Pumps , CSU's ) as per the specifications and approved drawings.
Gate valve for drain with insulation as per the specifications and approved drawings.
QTY-10(NOS)Ø 25 mm
QTY-14(NOS)Ø 32 mm
Double float Automatic air vents with QTY-32(NOS) Ø 25 mm as per the specifications and approved drawings.
DRAIN PIPE:
Supply, Installation, Testing and Commissioning of CPVC (Chlorinated Poly Vinyl Chloride) pipes condensate drain piping insulated using 9 mm thick nitrile rubber tubes including fitting and supports as per the specifications and approved drawings.
QTY-01 Lot Ø 25 mm
QTY-01 Lot (Ø 32 mm
QTY-01 Lot Ø 40 mm
HOT WATER SYSTEM WITH VALVES AND ACCESSORIES:
Supply, Installation, Testing and Commissioning of butterfly / isolation valve'swith QTY-30(NOS) Ø 50 mm, matching flanges , bolt, nuts,Nitrile Rubber insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with 24G Aluminium cladding for Exposed , all etc., complete as per specifications and approved drawings.
Supply, Installation, Testing and Commissioning of Y Strainers consisting of QTY-12(NOS)Ø 50 mm, magnetic screen , bolt, nuts, insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with 24G Aluminium cladding, all etc., complete as per specifications and approved drawings.
Supply, Installation, Testing and Commissioning of Non return valves with QTY-12(NOS) Ø 50 mm, matching flanges , bolt, nuts, insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with 24G Aluminium cladding, all etc., complete as per specifications and approved drawings. .
Supply, Installation, Testing and Commissioning of balancing (Manual) with QTY-12(NOS) Ø 50 mm, matching flanges , bolt, nuts, Nitrile rubber insulation with GC cloth and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with (24G Aluminium cladding for Exposed), all etc., complete as per specifications and approved drawings.
Supply, installation, testing & commissioning of 3 - WAY MOTORISED VALVE with QTY-6(NOS) Ø 50 mm, spring return , matching flanges,necessary digital thermostat And control wiring bolt, nuts, insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering etc., complete as per specifications and approved drawings.
Supply, Installation, Testing and Commissioning of flexible connections (Bellows) ,QTY-12(NOS) Ø 50 mm suitable for working pressure of PN16. as per the specifications and approved drawings.
Supply, Installation, Testing and Commissioning of Cabinet type/ Circular Inline Ducted Exhaust Fan complete with TEFC Motor with suitable supports and other accessories complete of following capacities .
QTY-8(NOS)700cfm @ 20 mm TSP
QTY-2(NOS)650cfm @ 20 mm TSP
ELECTRICAL WORKS:
Main Panel for Chillers , Pumps & Ahu's:
Supply, Installation, Testing and Commissioning of following size 1.1 KV Grade Aluminum / Copper conductor XLPE insulated PVC sheathed armoured cable and shall be laid on cable tray with all installation materials. the cable shall conform to IS 7098 / part-I.
QTY-01 Lot 3.5C x 240 sq.mm. - (Aluminum) (for Chillers)
QTY-01 Lot 3C x 10 Sq.mm. - (Copper) (for Cooling tower ,chilled water Primary , Secondary Pumps & Condensor Pump)
QTY-01 Lot 3C x 6 Sq.mm. - (Copper) (for pressurisation unit).
Supply, Installation, Testing and Commissioning of POWER CABLING of QTY-120(RM)3C x 2.5 sq.mm copper cable, for each IDU to be suitably laid in PVC conduit as per site requirement.
ELECTRICAL TERMINATIONS WITH DOUBLE COMPRESSION GLANDS / LUGS:
Supply, Installation, Testing and Commissioning of QTY-3(SET) 3.5C x 240 sq.mm. Al armoured (For CHILLERS)
Supply, Installation, Testing and Commissioning of QTY-9(SET) 3C x 10 sq.mm. Al armoured (Copper) (For PUMPS )
Supply, Installation, Testing and Commissioning of QTY-1(SET)3C x 6 sq.mm. Al armoured (Copper) (For PRESSURISATION UNIT ).
Supply, Installation, Testing and Commissioning of REMOTE CABLING QTY-01 Lot of 4C x 1 Sq.mm. copper cable between each IDU & its wired remote to be suitably laid in PVC conduit as per site requirement.
EARTHING SYSTEM:
Supply, Installation, Testing and Commissioning of GI flat QTY-01 Lot 50 mm x 6 mm.
Supply, Installation, Testing and Commissioning of single core Green PVC insulated QTY-01 Lot 2.5 sq.mm. wire.
CABLE TRAY:
Supply, Installation, Testing and Commissioning of powder coated GI Cable tray of perforated type QTY-01 Lot 150mm wide with GI cover (both 2mm thick) including suitable powder coated MS supports as per the specifications and approved drawings.
Supply, Installation, Testing and Commissioning of powder coated GI Cable tray of perforated type QTY-01 Lot 300mm wide with GI cover (both 2mm thick) including suitable powder coated MS supports as per the specifications and approved drawings.
ENGINEERING CHARGES:
QTY-1(LOT)Engineering, documentation, shop drawings, technical writeup, logic development, graphics development, installation, testing and commissioning
QTY-13(NOS)Supply,Installation,Testing and Commissioning of Duct Heaters to control the RH,with DP air flow Switch and safety Thermostats, Digital RH Control panel Wall mounted Control Panel Supplied along with Duct Mountable RH sensor,Flange In type DUCT Cross section /Duct Heater for Ceiling Suspended Units. (Note :- (i) Foundation and MS structures/ supports to equipment's such as chillers, AHU's, HWG, Lt Panel board,Pump sets, cooling towers, Pipe line,common headers dtc. Including other masonry work connected with the installation of equipmen's. (ii) Excavation and earth work for pipe work, cable work, foundation suppports etc. (iii) Opening in walls for duct work grills, diffusers, blanking plates, finishing of opening including painting etc. (iv) separate Earthing to AC installations as per direction. (v) Routine and perventive maintenance shall be covered under defect liablity preiods also i.e. for period of 24 months from the satisfactory completion of Phase II test, Any other items/equipment's to complete the AC plant instalation to achieve the desire temp. the cost ot the same deemed to be inclusive in the tare quored by the firm. (v) Overall COP of plant as per IS standards. (vi) Reqiured data for AC plant - Relative Himidity (RH) : 55 +/-5% DB deg C : 22+/2-% (vii) Painting to all MS structures/supports and pipe line as directed.
DG SET
All the DG set shall be provided as per following specifications mentioned below: A. Alternator : The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 or latest version with regulation of +5% from no load to full load. degree of protections shall be IP23. B.Diesel Engine : Cummins /Perkins/volvo Catterpiller Diesel Engine start, developing suitable BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 320 KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc. 01. Exhaust pipe of required size and length with insulation or clading. 02. Diesel tank suitable for 8 to 12 Hours running capacity. 03. Residential Silencer. 04. SMF Batteries with leads as per the Manufacturer standards Generating set application with following accessories: 1) Radiator with coolant 2) Fuel pump 3) Governor - class A 4) Lube Oil filter 5) Diesel Filter 6) Air cleaner 7) Flywheel Housing and flywheel to suit Single bearing Alternator 8) Electrical Starter Motor 9) Battery Charging Alternator 10) First fill of Lube oil 11) Shut Off Coils for: 12) Low Lube Oil Pressure 13) High Water Temperature
14) AMF panel with acoustic enclosure.:- 320KVA DG SET WITH INBUILT AMF PANEL/ISOLATOR PANEL (WITH ACOUSTIC ENCLOSURE ) Supply, Transportation, erection and commissioning (Excluding Foundation) of 3Phase, 415, 50Hz, water cooled multicylinder diesel generator set with alternator of 320KVA contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete having IP-52 protection, Acoustic Enclosure as per CPCB norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB norms etc. and Supply ,Installation ,testing & commissioning of Smoke Exaust Pipe of 250mm dia size of 40Meter
15) Lead acid storage maintenance free battery 12 volts of rating 180AH (01 Nos) with charging alternator, ammeter, as recommended by manufacturer make- Exide along with copper battery lead and connector. 16) Battery rack made out of MS angle iron 40mm x 40mm x 5mm & 150mm height. 17) Standard safety device. 18) In built fuel tank of suitable capacity for minimum 08 Hrs run with mechanical level indicator, detachable strainer, drain cock, fuel outlet, air vent and locking arrangement etc. Including fuel pipe connections. 19) Exhaust silencer (Residential silencer) with exhaust piping of suitable size brought out side on top of size 76.5 mm dia and complete length of silencer and exhaust piping continuously wrapped with 12mm dia asbestos rope and suitable anti vibration arrangement around pipe passing through wall. 20) LCD display type control panel as per manufacturer’s instruction indicating KWH, KVA, PF, Volts, Amps, Hz, RPM hrs, Oil pressure, Oil temperature, coolant temperature fuel level battery charging lamp and indicator lamp (PYB), panel duly pre wired and displaying protection and safety as under:- (a) Protection: - (i) Short circuit, over load, over speed, earth fault as standard and reverse power as optional. (ii) Safety: - Auto shut down, visual and audio alarm for low lubricant, oil pressure, high coolant temperature, low fuel level, canopy, temperature and radiator water level. (iii) Alternator 320 KVA brush less type at 0.8 power factor, self-regulated, self-excited, screen protected 3 phase with neutral 415 volts 50 Hz 150,0, RPM, as per IS: 13364/ IS: 2613/ IS: 4722 complete with automatic voltage regulator, having voltage regulation +/- 1% SPDP enclose including making cable connections, insulation Class-H and alternator control panel as supplied by manufacturer.
(iv) Base frame sturdy, MS Fabricated, channel iron base frame for mounting the engine and alternator with anti-vibration pads. (v) Acoustic enclose of suitable size to accommodate DG Set 320 KVA, modular construction, fabricated out of 3mm thick, cold, annealed CRCA sheet duly epoxy painted doors to be provided with high quality EDPN gasket, duly epoxy painted, the canopy to be equipped with heavy duty fans of reputed manufacturer for air circulation and cooling the canopy, rock wool of requisite density Kg per Cum to be used for insulation, Enclosure to be provided with one light point controlled with one witch for internal lighting, Noise level at one metre to be 75 decibels @ one mtr in line as per latest CPCB norms.
Notes:- (i) The engine of DG set suitable conditioned to suit the climatic condition of Mumbai Station, so as to give desired outputs including and testing up to 10% over load. (ii) Foundation of DG set (PCC/RCC) will be provided by the contractor and will be made as per the manufacturers instruction. Cost of foundation is deemed to be included in the rate of this item. (iii) The items required for testing of DG set e.g fuel, tripod, tools, water tank etc and panel as below shall be provided by the contractor and the rate of which is deemed to be included in the rate of this item. Testing of DG set will be carried out as specified. (iv) The DG set shall only be procured after completion of work upto 75% in case earlier procurement by contractor “No payment” shall be made for this item. (v) Diesel and lubrication, testing equipment etc. required for testing and commissioning of DG set as per department procedure shall be arranged by contractor at his own cost and expenses. (vi) The rate shall be deemed to be inclusive of 04 Nos earthing. Supply and fixing GI tubing 80mm bore light grade with 20 mm dia asbestos rope wound on GI tubing and cladding with 2mm thick aluminium sheet including socketed/flanges for extending exhaust pipe of DG set complete all as specified and as directed.
Subtotal
MAHINDER PAL CONSTRUCTIONS PVT LTD (BID ID -3193765)
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED (BID ID -3193973)
Precision Infraprojects (BID ID -3193939)
Mukund Enterprises (BID ID -3173250)
TALWADEKARS INDIA BUILDCON (BID ID -3202214)
B D Raizada Projects Pvt Ltd (BID ID -3194001)
MUKUL BUILDERS LLP (BID ID -3194047)
MC Gandhi and Sons (BID ID -3183475)
SOOD ASSOCIATES PVT LTD (BID ID -3194149)
Hariom Projects Pvt Ltd (BID ID -3176016)
Brahma Infra (BID ID -3194005)
NSC Projects Pvt. Ltd. (BID ID -3201757)
SHRI GURMUKHDAS CONTRACTORS PVT. LTD. (BID ID -3194083)
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid