Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹30.2 L+₹3.4 L (12.7%)Rejected-Finance ALPHA HOUSE PLOT NO 29 AGP P10 ASHWIN SECTOR NEW CIDCO NASIK 422 009 | NASHIK | MAHARASHTRA | 422009 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹31.0 L+₹4.2 L (15.7%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹32.6 L+₹5.8 L (21.6%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹35.2 L+₹8.4 L (31.4%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹38.2 L
EMD Value
₹76,500
Closing Date
7 Feb 2024, 6:00 pmClosed
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH)
AS PER TENDER DOCUMENTS
2024_MES_637224_1
86941/E8
Open Tender
Civil Works
Item Rate
180 days
DEOLALI
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE DEOLALI
₹76,500
Yes
16 Apr 2024
12 Jan 2024
9 Feb 2024
12 Jan 2024
7 Feb 2024
26 Jan 2024
13 Jan 2024 - 19 Jan 2024
Amount
Dismantling of Single layer Mangalore pattern or similar tiles in roofing including ridge complete all as specified.
Dismantling of battens for tiles, singles etc, of any size including tiling fillets exc 15 cm complete all as specified.
Dismantling unframed work of timber scantlings 40 sq.m and over in any section, in any position complete all as specified.
S & F for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt weided tubes conforming ti I.S 1161-1998 grade St 240 complete all as specified.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of anY colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified.
M & L Two coats of synthetic enamel paint over priming with red oxide over preparation of new surfaces of any description over 10 cm width or girth complete all as specified and as directed.
Demolition of concrete in ground floors & paving not exc 15cm thickness (below or above ground level) complete all as specified.
M & L for Machine cut kota stone slab flooring 20-25mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab inclunding rubbing and polishing complete complete all as specified.
All as per item no -9 but as a skirting complete all as specified.
M & L for screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes Complete all as specified.
M & L for Cement concrete as PCC 1:5:10 type E-2 using (40mm graded stone aggregate) as foundations,filling and mass concrete complete all as specified.
Demolition of brick work or stone/boulder masonary, laid in cement mortar or cement lime mortar complete all as specified.
M&L Brickwork with sub class 'B' brick straight or curved on plan n.exc 6m mean radius in cm 1:6 using old size brick complete all as specified.
M & L for rendering 10 mm thick with ready mix plaster of stone masonarysurface or concrete surfaces complete all as specified and as directed.
M & L for rendering 15 mm thick with ready mix plaster of stone masonarysurface or concrete surfaces complete all as specified and as directed.
M&L for two coats of cement base paint over chalk whitening newly plastered surfaces of walls including preparation of surfaces all as specified.
M & L for Two coat of white wash over prepation new surface complete all as specified.
M&L for 75 mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection complete all as specified and directed.
M&L for RCC M-25 (using 20mm graded stone aggregate) as in beams, cantilevers, bressumers, lintels,plinth beam etc.including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified.
S&F 10mm dia and above TMT bars cut to length, bent to shape as required including cranking, hooking ends & binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and doirected.
-Ditto- all as item No 21 here in before but 5,, dia and over upto & including 10mm dia in stirrups, spaces and binders.
Excavating in trenches n exc 1.50m in width and n exc 1.50m in depth for foundation, manholes etc as well as n exc 10 sqmm on plan area and getting out in soft/hard and dense soil all as specified and directed.
Returning, filling in including spreading, watering & well ramming in layers n. exc 25 cm thick complete all as specified and directed.
Removal of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified & directed by Engr-in-Charge.
Taking down chowkats or frames exc.1.5 sq.m but not exc. 4 sq.m each but with shutters ( without taking off shutters from the frame ) and removing to or from store complete all as specified and as directed.
Dismantling of plain or corrugated, steel sheets in wall coverings including ridges etc complete all as specified and directed.
M&L framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
M&L for precast cement concrete interlocking tiles 80 mm thick with strength M- 40 N/sqmm as in floor/pavement with grey cement and pigment laid on 50 mm thick stone dust cushioning laid dry to the profile complete all as specified and as directed.
M&L for sand filling under floor or in foundation including watering and consolidation.
S&F 1.25 mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer;erected in position as indicated,complete: push pull or manual type complete all as specified and directed by engr-in-charge.
Mild steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5 cm long but not exceeding 10 cm long , 16 to 20mm dia of neck as specified and directed.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified.
Taking down unserviceable copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, socket outlets, ceiling roses, pendent brackets, holders etc.removing marerialso storeforeeping in safe custody or for taking credt and making good disturbed surfaces of walls, floor etc.complete all as directed.
M&L point point wiring with PVC insulated 1.5 sq mm multistranded copper conductor cable ,FRLS,1100 volt grade drawn in and incl surface mounted ERW stove enamelled , black steel conduit not less than less 20 mm dia with and including flame proof bends and elbows, couplers, bell mouth reducer except junction box all as per relevent IS and type tested/approved by CMRI Dhanbad fixed with solid baked distance saddles ,and elevated MS spacer plate fixed with nettle fold GI screws along with 1.5 sq mm PVC insulated solid strand copper conductor FRLS 1100 Volt grade as ECC connected to common earth dolly .
a) One light/fan point controlled by one rotory switch.
b) One 3 pin socket outlet, 5 amps, independent, with cables 1.5 sq. mm size
S&F of switch flame proof rotary type with termination box in LM-6, 16 Amp, single pole 250 V. MAKE-Flexpro / FEPL/SUDHIR/SHYAAM/BAJAJ
S&F flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth
S&F flame proof ceiling fan regulator in LM6 cable termination box in LM6,
Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 15W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size
S&F flame proof exchaust fan of size 380 mm sweep, 1440 RPM, single phase suitable for 230 Volts, 50 HZ suppy inclulding louvres of suitable size with necessary flame proof metallic hose conduit and connecting nipple including cutting chases/ wall for making hole of fan size, including plastering and making distrubed surface match with the existing surface all as specified. Make:- "SHYAAM SWITCHGEARS PVT. LTD" or equivalent in Havells/ Bajaj/ Crompton Greaves/ Philips.
S&F Flameproof, weatherproof ceiling fan 1200 mm sweep single phase in cast aluminium LM6 all specified and dircted.
S&F Supply and fix flame proof MCB DB SPN 6 way complete with MCB SPN 16A- 01 No SP – 10A – 4 Nos all as specified and directed Make :- Sudhir, Cat No, MCB DB/186
S&F single pointed air termination, aluminium rod 12 mm dia and 300 mm long incl suport block incl taking down u/s complete all as specified and directed.
Supply & fix aluminium strip 25 x 3 mm complete duly fixed on porcelain/epoxy insulator with the help of nut, bolt, and washers etc for roof and down conductor above ground (all the joint shall be properly riveted and brazed welded), incl taking down any type strip complete all as specified and directed.
Supply and installation of earth continuity conductor or main earthing lead fixed to wall on batten or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32 x 6mm GI strip any type complete.
S&F earth test point terminal block made of gun metal or phosphorous bronze size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long hex. Head screw, including factory made test point terminal box, complete with suitable polycaronate box with lacking arrangement all as specified and directed by Engr-in-charge.
Supply and lay 40 mm bore GI tubing light grade, ISI marked, for cable protection at road crossing/floor/wall/ on poles or at any indicated situation etc duly sealed at both end after drawing cable including necessary clamps,saddels etc complete all as specified and as directed.
M&L earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI strip 32x6mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia Med grade GI pipe for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- GI strip and protecton light grade GI pipe upto 7.5 mtr shall be deemed to be in the rates.
M&L for Providing PCC 1:2:4 type B-1 20 mm graded aggregate for GI tubing post for lightening protection complete all as specified and directed.
Earthing complete with galvanized mild steel earth plate electrode size 600x600x6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 part-I, connected to test point complete, all as specified and testing on completion.
Alpha Construction
Jay Kusalkar Enterprises
M/S B R BHALERAO
M/S R.K.S. CONSTRUCTION
sunway associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .