Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAccepted-AOC 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹3.0 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹3.3 Cr+₹31.8 L (10.6%)Rejected-AOC | ₹3.3 Cr+₹31.8 L (10.6%) | L2 | Rejected-AOC HIGHER BIDDER |
| 3 | L3₹3.5 Cr+₹44.3 L (14.7%)Rejected-AOC 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹3.5 Cr+₹44.3 L (14.7%) | L3 | Rejected-AOC HIGHER BIDDER |
| 4 | L4₹3.7 Cr+₹64.4 L (21.4%)Rejected-AOC PI NO 13 S NO 81 82 BEHIND 132 33 KVA MSEB SUBSTATION MIDC AREA AMBAD NASHIK 422 010 | NASHIK | NASHIK | MAHARASHTRA | 422010 | ₹3.7 Cr+₹64.4 L (21.4%) | L4 | Rejected-AOC HIGHER BIDDER |
| 5 | L5₹3.7 Cr+₹73.1 L (24.3%)Rejected-AOC 2ND FLOOR 9 EZRA STREET KOLKATA WEST BENGAL 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹3.7 Cr+₹73.1 L (24.3%) | L5 | Rejected-AOC HIGHER BIDDER |
Tender Value
Refer Docs
EMD Value
₹4.5 L
Closing Date
23 Aug 2021, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
PROVISION OF 33 KV FEEDER MAIN FROM SALIGAON AND AUGMENTATION OF 33 KVA SUBSTATION AT INS MANDOVI GOA UNDER AGE I MANDOVI
2021_MES_449721_1
85368/E8
Open Tender
Civil Works
Lump-sum
364 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹2,000
Yes
AGE I MANDOVI
₹4.5 L
Yes
6 Nov 2021
9 Jun 2021
25 Aug 2021
9 Jun 2021
23 Aug 2021
28 Jul 2021
Amount
Total amount of Sch 'A' Part-I (BUILDINGS & STRUCTURES) brought forward from Serial Page No. 39
Total amount of Sch 'A' Part-II (EXCAVATION, EARTH WORK & SITE CLEARANCE ) brought forward from Serial Page No. 41 ( R )
Total amount of Sch 'A' Part-III (INTERNAL WATER SUPPLY) brought forward from Serial Page No.43(R )
Total amount of Sch 'A' Part-IV (INTERNAL ELECTRIFICATION ) brought forward from Serial Page No.47
Total amount of Sch 'A' Part-V(FOOT PATH) brought forward from Serial Page No.48
Total amount of Sch 'A' Part-VI (SEWAGE DISPOSAL ) brought forward from Serial Page No.51
Total amount of Sch 'A' Part VII (AREA DRAINAGE) brought forward from Serial Page No.53
Total amount of Sch 'A' Part-VIII (CHAIN LINK FENCING) brought forward from Serial Page No.56
Total amount of Sch 'A' Part-IX (GATE) brought forward from Serial Page No.58
Total amount of Sch 'A' Part-X (EXTERNAL ELECTRIFICATION) brought forward from Serial Page No.65 ( R )
Sch 'A' Part- XI - MISCELLANEOUS ITEMS (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.)
Internal Electrification
S&F LED tube light fitting 1 X 20 watt baton T5 CLASSIC integrated LED chanel integral sleek extruded polycarbonate LED channel with white acrylic cover alonwith LED tube ROD 01 No including flexible wire three core from existing ceiling rose to fitting duly mounted on PVC block with steel screw & sleeves complete all as specified and as directed.
S&F LED bulbs 9 Watt, retrofit type, warm white complete all as specified and as directed.
S&F exhaust fan 300 mm sweep with louvers complete with suitable MS Bracket, nuts,bolts and fixing arrangement single phase 230/240 volt AC supply 50 HZ including making holes and PCC work all as specified and as directed.
S&F MCB 6-32 Amp 240 Volt single pole 'B' series all as specified and as directed.
Supply and fixing of MCB DP 32 Amp 230 Volt 50HZ AC supply all as specified and as directed.
Supply , fixing , testing and commissioning of Ceiling Fan 1200mm sweep white/ ivory colour with all accesories complete suitable for single phase 230 Volts AC supply with necessary electrical connection and fixing arrangement complete all as specified and as directed.
Supply and fix EDGE series LED street light fitting 65 Watts as per Bajaj product code no. 169761 luminaries type BRTFG 65 W LED I /Havells /CG complete with bracket made out of 40 mm dia GI light grade tubing not less than 1.5 mtr long bent to shape including pole clamps made out of 50 x 6 mm flat and nut bolts and washers etc all as specified and as directed.
External Electrification
Supply, installation commissioning and testing isolator ( gang operated air break switch 11 KV, 400 Amp outdoor type triple pole suitable for horizontal or vertical mounting moving type consisting of hot dipped galvanized channel having two nos 11 KV post type insulator in staked 3 such stack per phase copper alloy high pressure heavily tinned dual contact plate MS arcing horn complete mounted on MS angle/channel frame consisting of 25 mm dia galvanized medium grade pipe as operating rod of suitable height operating handle with locking arrangement both on off or on position including in earthling arrangement in off position all as specified and as directed.
Supply, installation, testing and commissioning of gang operated air break switch 33 KV, 200 Amp outdoor type triple pole suitable for horizontal mounting type suitable for manual operation from ground level, triple pole, double break suitable for horizontal mounting consisting of hot dipped galvanized steel channel base having 3 nos 33 KV post top insulator per phase complete with copper contact element, MS flat, copper blade, bearing assembly etc and suitable GI pipe of 40mm dia galvanised medium grade pipe as down rod lever between coupling bar and operation handle with locking arrangement at both ON and OFF position suitable for 33kv system having earth link system comprising earth switch indicator and auxiliary switch complete all as as specified and as directed (1). For main incomming -1 (2). Two nos for outgoing feeder -4 (2 for incoming& 2 for outgoing) (3). For 33KV/0.433KV station transformer-1
M & L for drop out fuse assembly for 33 KV, 3 Phase of 200 Amp capacity each pole, Double stack cannel type,consisting of galvanized steel base paper fuse carrying brackets, mounting channel, separating rod complete all as specified all as directed ( for Station transformer)
Supply and install HT 33 KV 3 Phase 50 cycles totally enclosed metal clad SF6 switch gear having rupturing capacity upto 350 MVA , Over load and earth fault protection, Ammeter, voltmeter and of rating up to 630 Amps,. Class of breaker C1-M2,rated voltage 36 Kv, insulation level(Kvp) 1.2/50 micro second pulse with stand voltage of 170v,maximum permissible switching over voltage 112v, operating mechanism spring charged, No of trip coils- two nos common for 3 pole, each having the capacity to trip all three pole sucessfully, trip coil and closing coil voltage 30 V DC. The auxillary supply voltage shall be 85% to 110% of the rated 30V in supply for closing coil and the same shall be 70% to 110% for tripping coil. The operating voltage for motor operated spring charged mechanism shall be 400V AC, 3phase, 50Hz or 230V 1-phase,50Hz. The motor shall operate at a voltage of 85% to 110V of the supply voltage.( for 33 KV incoming line from GSEB - 01. For 33KV/11KV transformer- 2nos )
(a) Two No 30 volts DC tripping coil (b) One No 30 volts DC closing coil (c) One No spring charged motor suitable for 230 volts AC supply (d) Mechanical on/off indicator showing spring charged and spring free position. (e) One set of mechanical trip and close lever (f) One set of cable terminal block located at safe distance inside the box for control cable . (g) one set of cable entry glands for control cables . (h) Crank for manual charging spring (j) One 80 watt 230 volts space strip heater with thermostat and switch. (k) One No local and remote operation switch . (l) One 1.6 mm thick CRCA sheet fabricated factory made, cubical panel, powder coated out door type for the circuit breaker, totally enclosed, floor mounted comprising of:- (i)Auxiliary switch with four No and four NC contracts as recommended by the manufacturer (ii) Operation recording meter mechanical (iii) Manual / auto and local remote arrangement (iv) 02 Nos earthing terminals. (v) Other accessories as provided by the manufacturer.
(d) Auxiliary relay scada competible for Buchholz, WTI, OTI alarm and trip separately -02 nos ( e) Annuiceator complete with showing type of fault , accept/reset button with minimum 12 windows and suitable for auxiliary supply voltage 110 volt.-1NO (f) Under voltage single phase /Over voltage relay– 3 No (h) Trip Circuit Supervision Relay (VAX) – 1 No (j) Digital independent Volt meter and ammeter of suitable ratings- 01 each (k)Auxiliary Supply Voltage for the Relay/Close/Trip coil 30 Volt DC.
Note for item No 11.12 -the above Remote control panel sall be combined together to form one composite panel . All control wiring ,connection internal& external, including up to UPS/ Battary bank panel & any item electrical & machenical not mentioned but technically required & essencially required is deemed tobe included in above item quoted rate .
Supply,erection,testing & commissioning current transformer of 33 KV single phase,outdoor type 3 core CT of ratio 100/50/5-5 Amp with suitable burden 15VA ,Insulation level 70 KVp/170KVp as IS-2705 & class of accuracy complete with associated terminal box connecting link ect as per relevent ISS and as required. ( for Main incoming)
Supply,erection,testing & commissioning current transformer of 33 KV single phase,outdoor type 3 core CT of ratio 50/25/5-5 Amp with suitable burden 15VA ,Insulation level 70 KVp/170KVp as IS-2705 & class of accuracy complete with associated terminal box connecting link etc as per relevent ISS and as required. 01. For 33 KV/11KV transformer -2 Nos
S&F, testing 33 KV/110 volts outdoor type single pole potential transformer oil immersed and self cooled PT ratio 33KV/rt3/110V/rt3/ class 0.5-3, burden 50VA, insulation level 70KVp/170KVp, confirming to IS-3156 . 01. For Main incomer,02. For 33KV bus of 33/11KV Transformers)
Supply, installation, commissioning and testing the following Vacume Circuit breaker 11 KV, 3 phase 50 cycle ( 50 HZ) totally enclosed metal clad switch gear panel factory made, powder coated board with indoor vacuum circuit breaker floor mounted with common copper tinned bus bar complete all as specified
(A) INCOMING VCB PANEL EACH CONSISTING OF THE FOLLOWING EQUIPMENT :-(SUBSTATION NO 1) (a) One No 800 Amps capacity triple pole metal clad HT control panel totally enclosed extendable pattern air insulated metal clad housing, floor mounting vertically isolated, vermin proof, fully interlocked horizontal draw out type having double isolation features & control device with grounded neutral system and equipped with the following equipment. (i) One set of 3 phase 800 Amps air insulated, tinned copper bus bar with insulated colour coating. (ii) One set of side frame for housing for circuit breaker carriage. (iii) 6 Nos 800 amps isolators plugs. (iv) One set of mechanical interlock and automatic shutter system (v) One 800 Amp triple pole 350 MVA rupturing capacity VCB with automatic drop out and manually charged and motor operated spring closed mechanism complete with auxiliary switches, truck mounted draw out, vacume circuit breaker, incorporating mechanical as well as electrical ON/OFF indication, mechanical indication "ON" push button for emergency trip & 30 Volts DC trip coil.
(xiv) One No volt coil to trip the VCB on failure of electric supply. (xv) One set of mechanical interlock and automatic shutter gear. (xvi) 230 volts AC single phase 80 watt rated strip heater with switch and thermostat space heating. (xvii) Provision of 110 volts DC tripping system with suitable power pack including, siren/ horn alarm and accept switch and over voltage protecting relay. (xviii) Provision of motor charging with AC motor (xvix) Inbuild Power pack 30 v dc to be provided with panel at least for 30 minuite Back Up.
(B)OUT GOING VCB PANEL 400 AMPS COMPRISING THE FOLLOWING :-(for outgoing - 5 nos + spare-1 no ) (a) One No 400 Amps capacity triple pole metal clad HT control panel totally enclosed extendable pattern air insulated metal clad housing, floor mounting vertically isolated, vermin proof, fully interlocked horizontal draw out type having double isolation features & control device with grounded neutral system and equipped with the following equipment. (i) One set of 3 phase 400 amps air insulated tinned copper bus bar with color coating. (ii) One set of side frame houring with circuit breaker carriage. (iii) 06 Nos 400 amps isolating plugs. (iv) One set of mechanical interlock and automatic safety shutter gear.
(v) One 400 Amp triple pole 350 MVA rupturing capacity VCB with automatic drop out and manually charged and motor operated spring closed mechanism complete with auxiliary switches, truck mounted draw out, vacume circuit breaker, incarporating mechanical as well as electrical ON/OFF indication, mechanical indication "ON" push button for emergency trip & 30 Volts DC trip coil. (vi) One rear cable box for reception of one 95/185 sqmm HT XLPE 3 core cable 11 KV pressure. (vii) Three nos primary wound current transformer ratio 50/25/ 5-5 amps for the protection and metering having adequate VA burden and averaging. (viii) One set of 4 Nos LED lamps for indicates on/off/trip charging (ix) 144 mm square Type CT operated digital amp meter with 3 way rotary switch. (x) One No microprocessor relay 3 phase over current earth fault relay MC 61-CNX make : L&T (xi) Provision of DC 110 volts tripping system connected to common siren / horn alarm but with separated reception switch ( accept switch). (xii) Provn of motor charging with AC motor. (xvix) Inbuild Power pack 30 v dc to be provided with panel at least for 30 minuite Back Up.
(C)VCB PANEL 800 AMPS CAPACITY AS BUS COUPLER COMPRISING OF THE FOLLOWING :- (i) One set of side frame with housing of circuit breaker carriage. (ii) One set of 3 phase 800 amps air insulated connecting tank to connected bus bar with VCB including bus chamber. (iii) 06 Nos 800 amps isolating plug and sockets. (iv) One set of mechanical and electrical interlock system and automatic safety shutter gear complete with wring of electrical internal locking system. (v) One 800 Amp triple pole 350 MVA rupturing capacity VCB with automatic drop out and manually charged and motor operated spring closed mechanism complete with auxiliary switches, truck mounted draw out, vacume circuit breaker, incarporating mechanical as well as electrical ON/OFF indication, mechanical indication "ON" push button for emergency trip & 30 Volts DC trip coil. (vi) One set of indicating lamps red, green for indicate breaker close and open position. (vii) 230 volts AC single phase 80 watt rated space heater with switch and thermostat for space heating. (viii) Provn of motor charging with AC motor.
Supply, installation, testing and commissioning of out door type power transformer of capacity 2.5 MVA (2500 KVA) step down outdoor floor mounted, strip type Double copper wound 3 phase 50 cycles AC oil immersed natural air cooled type having no load voltage ratio 33000/11000 volts (corresponding to principal tapping) winding delta connected to primary side ( HV side) and star connected to secondary side (LV side). In accordance to appropriate vector group with neutral brought out to separate insulated terminal bush for earthing provision off load tap changer confirming to latest edition of IS- 2026 (part-1) - 2011. The transformer should not less than 6% impedance, voltage and mainly comprising of ECBC norms and following accessories and fittings:- (i) Oil conservator with filling hole and cap drain valve and magnetic oil level gauge,oil level indicator. (ii) Silica gel breather with connecting pipe with first fill of dehydrating agent and oil seal. (iii) Shut of valve between conservator and main tank. (iv) Explosion relief vent mounted on tank with double diapharm and equalizer pipe connected to conservator of space ( pressure relief valve). (v) Air release plug.
(vi) 150 mm dia oil temperature indicator OTI having 0 to 120 C with maximum reading pointer resetting device and electrically operated separate set of contacts for alarms and trip. (vii) Filter valve with threaded adopter at top and bottom. (viii) Sample valve / drain valve. (ix) Hand hole of sufficient size for access to the interior of tank. (x) Inspection cover (xi) Earthing terminals- 2 Nos for body earth & neutral earthing bushing terminal on transformer top cover. (xii) Cover lifting eyes and transformer lifting lugs. (xiii) Jocking pads. (xiv) Skids. (i) By- directional rollers ( 4 Nos). (ii) Rating plate and terminal marking plate. (iii) Extra bushing for neutral on LV side. (iv) Plain window type oil level gauge. (v) Double float buchholzs relay with alarm and trip contacts. (vi) First filling of new transformer oil with dielectric strength 60 KV. (vii) Terminal box for alarm and trip contacts.
(viii) Clamping device for clamping the transformer with foundation channel. (ix) Foundation channel for embedding in foundation. (x) HV bushing with arcing horns on HV side ( 33 KV side). (xi) Cable end box on secondary side for HT cables 11 KV of suitable size. (xii) 150 mm dia winding temperature indicator with alarm and trip contacts. (xiii) Radiator. (xiv) Off load tap changer having range ± 10% in steps of 1.25% in possible fine variation. Note : Earth work PCC in foundation of transformer and control cable of transformer to remote control panel shall be measured and paid separately.
Supply & install Station transformer step down Station Transformer 33 KV/ 433 Volts, 100 KVA outdoor type complete filled with oil ,standard fittings mounted on raised platform,HT 33 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondaryvoltage within limit, all as per IS:2026 (part-1)-2011 of capacity 100 KVA. (i) Oil conservator with filling hole and cap drain valve and magnetic oil level gauge,oil level indicator. (ii) Silica gel breather with connecting pipe with first fill of dehydrating agent and oil seal. (iii) Shut of valve between conservator and main tank. (iv) Explosion relief vent mounted on tank with double diapharm and equalizer pipe connected to conservator of space ( pressure relief valve). (v) Air release plug. (vi) 150 mm dia oil temperature indicator OTI having 0 to 120 C with maximum reading pointer resetting device and electrically operated separate set of contacts for alarms and trip. (vii) Filter valve with threaded adopter at top and bottom. (viii) Sample valve / drain valve. (ix) Hand hole of sufficient size for access to the interior of tank. (x) Inspection cover
(xi) Earthing terminals- 2 Nos for body earth & neutral earthing bushing terminal on transformer top cover. (xii) Cover lifting eyes and transformer lifting lugs. (xiii) Jocking pads. (xiv) Skids. (i) By- directional rollers ( 4 Nos). (ii) Rating plate and terminal marking plate. (iii) Extra bushing for neutral on LV side. (iv) Plain window type oil level gauge. (v) Double float buchholzs relay with alarm and trip contacts. (vi) First filling of new transformer oil with dielectric strength 60 KV. (vii) Terminal box for alarm and trip contacts. (viii) Clamping device for clamping the transformer with foundation channel. (ix) Foundation channel for embedding in foundation. (x) HV bushing with arcing horns on HV side ( 33 KV side). (xi) Cable end box on secondary side for LT cables 1100 V of suitable size. (xii) 150 mm dia winding temperature indicator with alarm and trip contacts. (xiv) Off load tap changer
a) Supply and fixing of MCCB 4 Pole,36KA,160Amp 415 Volt(as incommer) - 1no. b)Supply and fixing of MCCB 4 Pole,30KA,125Amp 415 Volt(as outgoing for Sub stn)- 1no c)Supply and fixing of MCCB 4 Pole,30KA,40Amp 415 Volt(as outgoing spare)-1 no d)Supply and fixing of MCCB 4 Pole,30KA,32Amp 415 Volt(as outgoing street light) e) Supply and fix contactor 3 pole(AC3rating) type MO 16 make L&T - 1no (f) Astronomical, Multifunctional digital time swithces cat no 004767 of legrand or equivalent of L & T cat no- T2 DD T7/MDS/GIC - 1 no
Supply,erection,testing & commissioning of substation busbar& stringing materials for 33KV bus
(a) Supply and stringing ACSR conductor for over head line securing on pole complete including binding wire ,jointing sleeves aluminium tap and PG clamp etc of any size all as specified and as directed. (DOG) 7/1.57-6/4.72mm (DOG) conductor
b) Aluminium SCH pipe for equipment busbar of current carrying capacity 1160 Amp 1.5 inch,outer dia 48.26 mm , Inner dia 40.894 mm , and thickness 3.690 mm
c) MS galvanized stranded size 7/4.00mm complete for substation sheilding
(d) Supply & fix for Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for ACSR DOG conductors, working pressure 11000 volts all as specified.
(e) Supply & fix for Post insulator, porcelain, vitreous suitable for 33 KV Line
(f) Supply and fix pin insulator HT 33KV 10 KA station class with all connecting accessories complete, all as directed.
g) Suspension clamp suitable for ACSR DOG conductor
h)"T" Clamp suitable for ACSR DOG conductor
i)"T" clamp suitable for ACSR DOG conductor in one end & 40mm dia AL tubein other end.
j) Bimetalic Pad clamps suitable suitable for isolator,CT,PT,breaker,transformer & LA etc
(k) M&L for structural rolled section as in main and cross beam,I-section,hip and jack rafters; purlins of any size where connected to common rafter and running rails and guides for sliding doors; fixed with angle cleats or other connected plates confirming toFe-290(Gde E 165)
(l) M&L for mild steel screw bolts ( Machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends,each screwedeach screwed end to be fitted with washers and one hexagonal or squar nut,but length of bolt exc 5 cm but n exc 10cm long of diameter of neck in mm 11to15
Supply fix of stainless stain grid type NGR housed in sheet steel enclosure powder coated with shade RAL-7032 having rated 11/1.72KV,rated resistance 38.26 ohm rated current 166 Amp,time rating 10 sec,temp rise 375 degree,outdoor type all as specified and as directed
Supply, laying & testing PVC sheathed cable galvanised steel strip or wire armoured, electric control cables (Heavy duty)with stranded copper conductor 1100 volts grade of following sizes.
(a)2.5 sqmm 2 core.
(b)2.5 sqmm 4 core.
(c)2.5 sqmm 8 core.
Supply,installation & commissioning of maintenance free (SMF) battery bank comprising of 2 Volts, 17 No.VRLA battaries" Standby Valve Regulated Lead acid (VRLA) cell of 2 volts,100AH each(average Discharge Voltage1.90VPC) including necessary internal connection , wooden racks suitable for kept at powerhouse as specified by Engr-in-Charge.(for trip ON/OFF of VCBs)
Supply,insatllation,testing & commissioning of battery charger with+1% Diditally controlled regulation suitable for above 50 volt DC battery charger suitable for VRLA battery bank with the float and boost(FC&BC) charging arrangement with all stranded protection housedin free standing cabinet of 2.0mm guage as per specifiaction
Supply and errection,testing & commissioning of 30 VDc distribution panel made of sheet steel(14SWG) and suitable for floor mounting. The distribution panel shall incorporate the following a) LED Indicating Double pole Lamps ,for battery incoming supply with red & green for Air break circuit breaker -1 no b) LED indicating lamp for Earth leakage -1no © Ammeter(range(0-50)- 1no d) Volt meter (range 0-50 V)-1no e) 16 Amp 30v double pole minitaure circuit breaker with overload protection of DC outgoing circuit.The unit will be complete with necessary internal wiring input & outgoing terminals earthing point andrating plate.- 4 nos
Supply and fix LED street light 45 watt, IP 65, Die cast aluminium housing heat sink heat toughened glass individual LED 3 stage CCCV driver with min 4 KV surge protection voltage range of 150-270V AC and DC output operating voltage of driver should be complied to SELV norms connecting with 1.5 Sqmm 3 core cable aluminium stranded conductor from OH feeder/junction box to fittings as per site requirement complete all as specified and as directed.
Supply and fix M & L Hot dip galvanised Iron octagonal pole of height 7 mtrs minimum galavnising of 70 microns, top 70 mm , bottom 130 mm and 3 mm sheet thickness in single section without any weld joints with square plate of minimum dimensions 225x225x12 mm foundation bolts, single arm GI bracket of 900x1000 mm for mounting the light fitting at an angle of 120 degree,backelite sheet with one 6 A SP MCB and 16 mm stud type connectors -04 nos inside the pole at the door opening for cable connections,common template s minimum 01 for each 15 poles all fixed and bolted on and including suitable PCC pedestal as per manufacturers recommendations and specifications all as directed ( for street/security lights) Mast and pole shaft shall be be as per BSEN 10025,IS 5986, ASTM A572 ,
Supply and fix M & L Hot dip galvanised Iron octagonal pole of height 12 mtrs minimum galavnising of 70 microns, top 90 mm , bottom 175 mm and 3 mm sheet thickness in single section without any weld joints with square plate of minimum dimensions 320x320x20 mm foundation bolts, all fixed and bolted on and including suitable PCC pedestal as per manufacturers recommendations and specifications all as directed ( for substation sheilding ) Mast and pole shaft shall be be as per BSEN 10025,IS 5986, ASTM A572
Supply and lay PVC insulated PVC sheathed electric control cable with stranded copper conductor of size 1.5 sqmm 2 core 1100 volt grade connections complete
Supply & fix single pointed air termination aluminium rod 12mm dia,300 mm long for substation building for lightening protection fixed on poles including all material the Substation or substation building connected to GI strip for earthing,connected on middle each corner of the 33 KV substation all as specified and as directed.
Supply and erection of fire fighting equipment with complete accessories including a frame of canel, angle iron,cutting,bending and welding with provision hooks for hanging bucket,fire extinguishres. Painting red colour over red oxide two coats.
a) GI bucket capacity 10Ltrs with handle to carry sand along with wooden/iron stand
(b) Fire Extinguisher Carbin Dioxide type of 4.5Kg capacity.Ceasefire 4.5kg CO2 Gas typre fire Extinguisher, Trolly mounted, Easy weight management Used Unused Mechanism Squeeze Grip, Gross weight 9.1kg empty weight 14.6kg, Can height 857MM, Diameter 140MM, Discharge timeless than 10secs controllable discharge mechanism Applicable on class B&C fire, B rating 21B, Can Construction : Hot Spinning/ Forging, Valve Construction : Forging & Machining, Internal coating of Can : Not Applicable, External Coating of Can : Spray painting sheet metal thickness 4.5MM, ISI Approved 1 year warranty. Make Cease Fire CO2-4.5Kg - Squeeze Grip - 1CO11CF
(c) Fire Extinguisher DryChemical powder[ABC] type 5 Kg capacity. Ceasefire 5 kg fire extinguisher mono Ammonium phosphate powder 50, stored pressure type, pressure Guage, Gross weight 8 Kg, empty weight 3 KG, can height 449 MM, Diameter 150 MM, discharge time less than 15 secs, controllable discharge mechanism, Range minimum 4 mtrs, applicable on class A,B,C & electrically started fire A rating 13A, B rating 34B, can construction deep down & CO2 Mig welded, Valve construction : Forging & Machining internal coating of can : Epoxy powder coating external coating of Can : Epoxy polyster powder coating, Sheet metal thickness : 1.80MM, ISI and EN approved, 5 years warranty.Make Cease Fire ABC Powder Map 10 5Kg - 1AB04CF
(d) Fire Extinguisher DryChemical powder[ABC] type 2 Kg capacity. Ceasefire 5 kg fire extinguisher mono Ammonium phosphate powder 50, stored pressure type, pressure Guage, Gross weight 3.6 Kg, empty weight 1.6 KG, can height 341 MM, Diameter 108 MM, discharge time less than 8 secs, controllable discharge mechanism, Range minimum 4 mtrs, applicable on class A,B,C & electrically started fire A rating 8A, B rating 21B, can construction deep down & CO2 Mig welded, Valve construction : Forging & Machining internal coating of can : Epoxy powder coating external coating of Can : Epoxy polyster powder coating, Sheet metal thickness : 1.60MM, ISI and EN approved, 5 years warranty.Make Cease Fire ABC Powder Map 10 5Kg - 1AB03CF
Material and labour for earthing for bore earthing 150 mm dia depth 50 mtr below ground level using earth electrode 50 mm dia GI pipe medium grade duly drilled hole of 12 mm dia, 15 Cm C/C on both side of the pipe including lowering in bore well upto the depth of 49 mtr and one mtr above the ground level, the pipe electrode should be filled around commercial salt chorcoal dust/ Breeze and magnesium phosphate of 30 cm layer each upto the fill length of pipe. the borewell should have 12 mtr of length 150 mm dia MS pipe for protection of borewell. welding of GI strip 50x6 mm on earth electrode GI pipe 50 mm dia upto the 20 mtr below ground level 15 mtr from the bore well to test point. Necessory water connection by GI steel tubing 15 mm dia and gun metal test point complete all as specified. GI strip more than 7.5 mtr shall be measured and paid seperately.For Power Transformer 2x 4 & Station transformer 4 , Lightening arrestor 2x4 , pole for top grid -4 nos) Note - Lightning arrestor Earthing shallbe independent)
UNITED TECHNO PROJECTS PVT LTD
Leo Air and Power Solution pvt Ltd.
NARMARAJ ELECTRICALS
surendra infrastructure pvt ltd
DURGAI ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .