Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 0.00₹12.4 LAccepted-AOC | ₹12.4 L | 0.00 | Accepted-AOC Eligible |
| 2 | Rejected-Technical | - | - | Rejected-Technical reject |
| Sl No | Description | Qty | Unit | T. GEORGE STEPHEN H1 |
|---|---|---|---|---|
| 1.00 | Dismantling the Brick Masonry in cement mortor cleaning away at carefully stocking materials usefull for reuse for any thickness at well | 3 | m³ | 302.96 ₹908.88 |
| 2.00 | Earth Work Excavation for foundation in all types of soils and sub soils to full depth (such as Soils in Rock / Silt / Light Black Cotton Soil / Ordinary Soil ) except in rock requiring blasting but inclusive of shoring, shuttering and bailing out water wherever necessary and refilling the sides of foundation with excavated earth other than sand in layers of 150 mm thick well rammed and consolidated, depositing the surplus earth in places shown by the Departmental Officers with initial lead of 10 m and initial lift of 2 m. Complete as per TNSS 23 & 24, V, VI (S2), VII, 9,10 | 9 | m³ | 263.78 ₹2,374.02 |
| 3.00 | Plain Cement Concrete of mix 1 : 4 : 8 (One Cement four sand eight aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. | 1 | m³ | 5,433.4 ₹5,433.40 |
| 4.00Supplying and errecting steel centering including necessary supports for plain surfaces for Reinforced Cement Concrete works such as Column footing, Column pedestals, plinth beams, grade beams, staircase steps, etc which requires only nominal strutting using mild steel sheets of size 90mm x60mm and 10Bg stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm center to center or at suitable intervals etc complete in all floors Complying with standard Specification( TNSS NO or NBC No 30(S) 86 86 A V, VI(S3)VII | ||||
| 5.00 | Footing | 8 | m² | 489 ₹3,912 |
| 6.00 | Beam Rcc Slab | 10 | m² | 1,085.1 ₹10,851 |
| 7.00 | Column 0.60x0.60m | 28 | m² | 1,302.12 ₹36,459.36 |
| 8.00Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - | ||||
| 9.00 | Upto Basement | 3 | m³ | 8,434.19 ₹25,302.57 |
| 10.00 | Ground Floor | 6 | m³ | 8,575.26 ₹51,451.56 |
Tender Value
₹15 L
EMD Value
₹15,000
Closing Date
10 Feb 2026, 3:00 pmClosed
Executive Officer
Thingalnagar Town Panchayat office
Construction of Entrance arch and Maintenance of Thingalnagar Town Panchayat Office Building in Thingalnager Town Panchayat
2026_DTP_649812_1
68/2025/A1
Open Tender
Civil Works
Thingalnagar
IIIrd and above
3 documents required · 3 mandatory
₹0
₹15,000
Thingalnagar Town Panchayat office
24 Feb 2026
1 Feb 2026
10 Feb 2026
1 Feb 2026
10 Feb 2026
1 Feb 2026
2 Feb 2026
Dismantling the Brick Masonry in cement mortor cleaning away at carefully stocking materials usefull for reuse for any thickness at well
Earth Work Excavation for foundation in all types of soils and sub soils to full depth (such as Soils in Rock / Silt / Light Black Cotton Soil / Ordinary Soil ) except in rock requiring blasting but inclusive of shoring, shuttering and bailing out water wherever necessary and refilling the sides of foundation with excavated earth other than sand in layers of 150 mm thick well rammed and consolidated, depositing the surplus earth in places shown by the Departmental Officers with initial lead of 10 m and initial lift of 2 m. Complete as per TNSS 23 & 24, V, VI (S2), VII, 9,10
Plain Cement Concrete of mix 1 : 4 : 8 (One Cement four sand eight aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification.
Supplying and errecting steel centering including necessary supports for plain surfaces for Reinforced Cement Concrete works such as Column footing, Column pedestals, plinth beams, grade beams, staircase steps, etc which requires only nominal strutting using mild steel sheets of size 90mm x60mm and 10Bg stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm center to center or at suitable intervals etc complete in all floors Complying with standard Specification( TNSS NO or NBC No 30(S) 86 86 A V, VI(S3)VII
Footing
Beam Rcc Slab
Column 0.60x0.60m
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers -
Upto Basement
Ground Floor
Supplying and Fabrication of Steel and placing in position MS / Ribbed tor steel grills for RCC works as per design given including cost of steel and GI binding wire in Floors etc., Complete complying with standard specification in force per Kilogram.
Special Plastering in C.M. 1 : 3 ( One cement, three sand) to 10 mm thick including all cost and conveyance of all materials to site including cost of cement which will be purchared locally by the contractor and conveyance of the same to the actual work site and cost form work including watering curing and all leads of good potable water and all other.
Brick Work in Cement Mortor 1:5 Mix (one cement, five sand) using new best Second Class Bricks of size 9 ” x 4 3/8 “x 2 3/4 ” from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications.
Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
Supplying and Painting the walls with Two Coats Weather sealed Exterior emulsion Paint as instructed by the departmrntal officers including Preparation of surface curing, etc complete in all floorscomplying with standard specification. ( The Colour and shade of the paint shall be got approved by the departmental officers.)
Supplying and laying in flooring with fully polished Sinthetic Grey colour Granite stone of 20mm thick (average) of 4' X 2' in size laid over base layer of cementmortar 1:3 (one cement and three Plastering sand) - 20 mm thick and applying cement slurry &pointed with white cement and colour pigments to the colour of stones and polished neatly as directed by the deparmental officers
Supplying, fabricating, erecting and fixing Hilux (or) Equivalent Board False Ceiling upto a ceiling height of 4.5m from floor level Using Perforated Sheets (10mm thick) including the cost all materials etc.,complete, in all floors.
Supply and Installation of Air Conditioner with Copper Coil 2.00 TR Split Type AC Unit - 5 Star Rated including the cost all materials etc.,complete
Supply and Fixing of LED Indoor Fittings (Light Emitting Diode) Higher End 18W LED 3000K Round Type Recessed Fitting with LED including the cost all materials etc.,complete
Supply and Fixing of 4 Feet LED Tube Light Fittings Higher End 20W LED Tube Lights including the cost all materials etc.,complete
Providing Cup-board Shutter with frame using termite /water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work.
Please Enable Macros to View BoQ information
Compatibility Report for BOQ-3.
Run on 10/5/2024 12:20
The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when you save this workbook in an earlier file format.
Significant loss of functionality
Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear clipped.
'BoQ1'!A1:II33
Minor loss of fidelity
Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.38 MB
Tendernotice_2.pdf
PDF • 8.84 MB
BOQ_779073.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid