Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC 35 PATHAK PARA ROAD FLAT NO 32C 3RD FLOOR SHANTINEER APARTMENT BEHALA KOLKATA 700060 | KOLKATA | KOLKATA | WEST BENGAL | 700060 | L1 | Accepted-AOC Being Lowest bidder and reasonable | |
| 2 | L2₹35.3 L+₹2.1 L (6.38%)Rejected-Finance 8 28 BIJOYGARH P O JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹37.1 L+₹3.9 L (11.8%)Rejected-Finance P 45 KHIRODE VIDYA BINOD AVENUE KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹37.1 L+₹3.9 L (11.8%)Rejected-Finance 8 27 BEJOYGARH JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹37.8 L+₹4.6 L (13.9%)Rejected-Finance BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
14 Oct 2022, 6:00 pmClosed
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIRS TO COMPOUND WALL, JAFRI WALL, BOUNDARY WALL, STEEL GATE, FENCING, RCC JALI WALL AND MISC EXTERNAL B/R WORKS INSIDE FORT WILLIAM UNDER GE(FW) KOLKATA
2022_MES_553822_1
8901/FW/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender docuemtns
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹60,000
20 Oct 2022
23 Sept 2022
15 Oct 2022
23 Sept 2022
14 Oct 2022
7 Oct 2022
Amount
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick below or above GL complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for and removal of debris outside MOD land complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for and removal of debris outside MOD land and disposed off complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as a specified and as directed
Dismantling wrought iron or mild steel work of any description in rafters, purlins and wind ties wtc complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting any gauge or any thickness in roof covering including stacking serviceable materials of re-use and removing unserviceable materials complete all as specified and directed.
Dismantling of old chain link wire mesh fencing including flat iron, ms round supporing bars, bracing bar etc complete all as specified and directed.
Dismantling posts or struts (wood, steel or RCC), any section, embedded in natural ground, including taking out embedded portion and making good disturbed ground, complete all as directed.
Dismantling posts or struts (wood, steel or RCC), any section, embedded in concrete, brick work, masonry etc., including taking out embedded portion and making good disturbed ground, complete all as directed.
Demolition of brick work built in cement mortar including all quions arches pillars etc but excluding ashlars facing,dressed stone work and precast concrete articles complete all as directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key and scrubbing down with water complete All as specified and as directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed.
Dismantling stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
Excavating in post hole (or similar hole) each n exc 0.5 cum getting out, returing, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 M and making good surface in soft and loose soil complete all as specified and as directed.
M&L PCC 1:4:8 type D2 (Using 40 mm graded stone aggregate) in Foundation, filling and mass concrete complete all as specified and as directed.
M&L PCC 1:3:6 type C2 (Using 40 mm graded stone aggregate) in Foundation, filling and mass concrete complete all as specified and as directed.
S&F in repair 35 mm thick precast cement concrete Type B-0 (1:2:4) (using 12.5 mm graded crushed stone aggregate) louvers and jallies including all moulding, but excluding frame set in cement mortar 1:4 including dismantling of existing jalli complete all as specified and as directed.
S&F MS angle, flats, etc independently fixed without connecting plates etc but ordinary length conforming to FE-410-W(Gde-E-250)quality A as in fencing posts including drilling holes for nuts and bolts and similar work complete all as specified and as directed.
Re-fixing of RCC post or angle iron post complete all as specified and as directed.
M&L Mild Steel Screw Bolts (machine made) 11mm to 15mm diameter of neck and length of bolt exc 5 Cm and not exc. 10 Cm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, complete all as specified and as directed.
S&F MS 10 mm dia round bar and fixed independently to angle iron for chain link fencing cut to length, bend to shape required, complete all as specified and as directed
S&F in repairs galvanized 2 strand steel barbed wire fencing conforming to IS : 278, with 2.24 mm dia. barb wire conforming to IS : 280 with zinc coating as per IS : 4826, barbed with 2 mm dia. barbs at 75 mm spacing and straining and fixing to any type of standard rails/RCC fencing posts straining bolts, including securing or tying at crossing with and fixing of galvanized mild steel wire, staples or steel pins etc., incl dismantling of existing barbed wires complete all as specified and directed. (Note: - Each line of wire will be measured)
Restraining, resceuring incl making good Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixeing to any type of standered rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staple or steel pins, etc. as directed (each line wire to be measured ) complete all as specified and as directed.
S&F 3mm dia PVC coated galvanised mild steel chain link fencing of mesh size 100x100mm fixed with straining bolts including line wire any mesh size and type to any type of standards, rails, straining bolts etc. including provision of binding wire, complete all as specified and as directed.
Re-fixing of old serviceable chain link fencing (Chain link fencing obtained from item No 15) including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
S&F in repair mild steel Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
S&F in repairs steel rolling shutters not exc 8.0 sqm of laths thickness 1.00 mm, with out ball bearing, as specified including top cover , anchoring rod, hasp and staple erected in position as indicated complete and two coats of synthetic enamel paint over a coat of primer incl taking down existing shutter complete all as specified and directed.
S&F in repairs steel rolling shutters exc 8.0 sqm but not exc 12.00 sqm, of laths thickness 1.25 mm, with ball bearing, as specified including top cover, anchoring rod, hasp and staple erected in position as indicated complete and two coats of synthetic enamel paint over a coat of primer incl taking down existing shutter complete all as specified and directed.
M&L servicing, overhauling, greasing, easing of existing rolling shutters of any area complete all as specified and directed.
Taking down existing rolling shutter incl covering guide, channe etc, of area not exc 8.00 sqm each, replacing damaged parts such as guide channel; shaft, ball bearing, laths, locking system, hood incl necessary welding and greasing complete as required and refixing in position etc complete all as specified and directed. (Note : Spare parts required will be measured and paid separately under respective items)
Taking down existing rolling shutter incl covering guide, channe etc, of area exc 8.00 sqm but not exc 12sqm each, replacing damaged parts such as guide channel; shaft, ball bearing, laths, locking system, hood incl necessary welding and greasing complete as required and refixing in position etc complete all as specified and directed. (NOTE: Spare parts required will be measured and paid separately under respective items)
S&F in repair safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
Supply only springs for rolling shutters complete all as specified and directed.
Supply only ball bearing for rolling shutters complete all as specified and directed.
Supply only guide channel complete all as specified and directed.
Supply only locking system for rolling shutter complete all as specified and directed.
M&L for running welding in repairs , not exceeding 2.5 cm length, thickness of metal to be welded not exceeding 6mm thick, complete all as specified and directed.
M&L for running welding in repairs , exceeding 2.5 cm but not exceeding 5 cm length, thickness of metal to be welded not exceeding 6mm thick, complete all as specified and directed.
M&L rolled mild steel in joist, channel, angle, or tee section fixed independently, without connecting plates, etc (cut to ordinary length i.e.. within 20mm of the length indicated) of FE-410- W(Gde-E-250) quality-B complete all as specified and directed.
M&L rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde-E-250) quality-B complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings Fe 410-W (Gde-E- 250) quality-B (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
M&L Mild steel framed work such as grills of ornamental type, gratings, etc with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works incl portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc confirming to grade Fe-290. Gde-E-165 complete all as specified and directed.
M&L for 18 to 20 mm thick black/coloured granite machine cut laid over 10mm thick screed bed in cement mortar 1:4 and jointed with grey or coloured cement to match with admixture of pigment to match the shade of granite including cutting polishing complete all as specified and directed.
-ditto- but as in vertical surfaces over and including 10 mm thick screed bed in cement mortar 1:3
M&L for 75mm thick PCC (1:3:6) type 'C-2' (using 40mm graded crushed stone aggregate) as in floor, plinth protection etc, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for forming contraction/dummy joints 65 mm deep x 10 mm wide filled with sealing compound Grade 'A' complete all as specified and as directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
-ditto- but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
-ditto- as per item no 47 above but using old serviceable sheets obtained from dismantling of sheets
S&F 0.56 mm thick plain aluminium sheeting alloy 31000 H4 as in ridges, hips, valley gutter, drip and straight flashing etc complete all as specified and directed. .
S&F Galvanised, corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 grams per sqm, fixed with 'L' type or 'J' type hook bolts complete all as specified and directed.
S&F in repair 2mm thick fibre glass reinforced transluent corrugated or plain coloured/printed sheeting with two corugation side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
M&L brick work with sub class'B' fly-ash bricks, straight or curved on plan exc 6m radius buit in cement mortar 1:6 complete all as a specified and as directed.
M&L for brick work with fly ash brick straight or cuved on plan to any radius in half bricks thick walls, built in 1:4 cement mortar complete all as directed.
M&L 15mm thick rendering on brick or concrete walls in cement mortar 1:6 finished evean smooth without using extra cement complete all as a specified and as directed
M&L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound (@ 200 ml per bag of cement or as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. (Note : Water Proofing compound shall be measured and paid separetly as "Supply only"
M&L 10mm thick rendering on ceiling surfaces in cement mortar 1:3 , finishing even and smooth without using extra cement including necessary scaffolding complete all as a specified and as directed
Supply only integral water proofing Compound, conforming to IS and as approved, complete all as specified.
M&L for PCC (1:3:6) type C-2 using 40 mm graded stone aggregates as in surface channels and drains including necessary form work complete all as specified and directed.
Forming fair finished drain or channel any inner girth in cement concrete, using extra cement, including forms, mould, mitred/stopped ends etc.
M&L for Cement Concrete type B-1, (1:2:4) using 20mm graded crushed stone aggregate in copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including use and waste formwork (straight or curved) complete all as specified and as directed.
M & L for precast RCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in cover slabs and the like including providing necessary form work etc, set in cement mortar (1:4) complete all as specified and as directed by the Engineer-in-Charge. (Note : Reinforcement to be measured and paid separately).
M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
-ditto- but 6 to 8 mm dia TMT bars
M&L for TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups , spacers and binders cut to length , bent to shape required as in reinforcement and binding with MS wire ( annealed ) not less than 0.90 mm dia complete all as specified and directed .
M&L for RCC 1:1½:3, type A1 (nominal mix) type A1 using 20 mm graded stone aggregates in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. (NOTE: MS reinforcement shall be measured and paid seperately)
M&L for RCC 1:1½:3, type A1 (nominal mix) (using 20mm graded stone aggregates) as in beams, cantilevers, bressummers, lintels over 1.5 mtr span complete all as specified and directed. (Note : Reinforcement to be measured and paid separately).
M & L for RCC 1:1½:3 (nominal mix) using 20 mm dia graded stone aggregates as in columns, pillars, posts etc complete all as specified and directed.
M&L for use and waste for form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams for rough finished surfaces of concrete flat complete all as specified and directed
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizontal or sloping) for fair finished surfaces complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs and similar work exc 10 cm but n exc 20 cm wide for rough finished surfaces complete all as specified and directed.
M&L for formwork to side of pillars, posts, struts, piers, columns for fair finished surfaces complete all as specified and directed.
M&L for hardcore of gauge not exc 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to true surface with broken stones complete all as specified and directed.
M&L for applying two coats of acrylic distemper on new plastered surfaces of ceilings, finished with rollers over a coat of alkali resistant primer incl preparation of surfaces complete all as specified and directed.
M&L for two coats of acrylic distemper over a coat of alkali resistant primer over 2 mm thick wall putty on new internal plastered wall surfaces after preparation of surfaces complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F cast iron rain water socket pipes, without ears, conforming to IS:1230-1979, 150 mm bore, fixed with cement joints complete all as specified and directed.
S&F 150 mm bore CI bends or elbow square for CI rain water pipes complete all as specified and directed.
S&F 150 mm bore CI double branch (Tee section) for CI rain water pipes complete all as specified and directed.
S&F cast iron rain water socket pipes, without ears, conforming to IS:1230-1979, 100 mm bore, fixed with cement joints complete all as specified and directed.
S&F 100 mm bore CI bends or elbow square for CI rain water pipes complete all as specified and directed.
S&F 100 mm bore CI double branch (Tee section) for CI rain water pipes complete all as specified and directed.
M&L bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required and similar small articles conforming to Fe-290 Gde-E-165 including painting two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) 100 mm set in cement mortar complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 110 mm bore PVC (SWR) junction single (single T) equal or unequal, complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint with brush over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of old decorated wall surfaces and applying one coat of cement base paint with brush complete all as specified and directed.
M&L for preparation of new surfaces of walls and soffit of chajja, roof slab etc., by cleaning, brooming, rubbing and scrapping as required using broom, emery paper, putty blade/scraper as applicable to make the surface free from protrutions, loose particles, dust etc including necessary safety & protective measures such as safety belt, headgear etc, finishing the surface with 2 mm thick exterior wall putty (in two layers) for smooth finish and finishing with two coats of weather proof exterior emulsion paint over a coat of suitable exterior primer of approved make using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for upto 4 storey building height complete all as specified and directed.
M&L for preparation of old treated/painted surfaces of walls and soffit of chajja, roof slab etc., by cleaning, brooming, rubbing and scrapping as required using broom, emery paper, putty blade/scraper as applicable to make the surface free from loose paint, algae formation, dust etc including necessary safety & protective measures such as safety belt, headgear etc including filling cracks upto 5mm with and including suitable elastomeric crackfill paste and applying one coat of weather proof exterior emulsion paint of approved make using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for upto 4 storey building height complete all as specified and directed.
M&L for complete removal of existing treatment on old painted surfaces of walls and soffit of chajja, roof slab etc. by using high pressure jet washer including cleaning the surface by scrapping as required using emery paper, putty blade/scraper as applicable for removing loose paint, corrosion, algae formation etc., to make the surface clean and free from dust, for upto 4 storey height including necessary scaffolding, safety and protective measures complete all as specified and directed.
M&L for complete removal of existing treatment on old painted surfaces of walls and soffit of chajja, roof slab etc. by scrapping and removing treated surfaces with mechanical wall sander (having vacuum mechanism for suction) having minimum 1500 RPM, sanding pad of 80 grit size having 7"- 9" dia (as required) including cleaning, watering to make the surface clean and free from dust, for upto 4 storey building height including necessary scaffolding, safety and protective measures complete all as specified and directed.
M&L for applying 2mm thick wall care putty (in two layers) on old cleaned surfaces of walls, soffits of chajja, roof slab etc, for smooth finish and finishing with two coats of weather proof exterior emulsion paint over a coat of suitable exterior primer of approved make using airless spray technology capable of operating single spray gun with hose of adequate length for upto 4 storey building height including necessary scaffolding, safety and protective measures complete all as specified and directed.
M&L Preparing new Surfaces of ceilings and applying Three coats of white wash complete all as specified and as directed.
M&L Preparing new Surfaces of walls and applying Three coats of white wash complete all as specified and as directed.
M&L for applying one coat of white wash to old decorated surfaces of wall including preparation of surfaces complete all as specified and as directed.
M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed.
M&L for providing 100 mm thick Plain Cement Concrete (1:4:8) type D2 using 40mm graded stone aggregate as in sub base of floors, path etc complete all as specified and directed.
M & L for heavy duty coloured ceramic floor tiles of size 300 x 300 x10mm thick in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete, laid over and including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. (MAKE : JOHNSON, Model : Endura or equivalent item in other makes listed in the tender)
Taking out of interlocking paver block, any shape or size and removing from site complete all as specified and directed.
Supply and laying machine pressed precast concrete interlocking paver block with grey cement and pigmnent of any shape and size as approved by GE conforming to IS 15658-2006 of 60 mm thickness, M-35 grade including taking out existing unserviceable paver blocks complete all as specified and directed. (NOTE: Sand for cushioning level will be measured and paid seperately)
M&L Sand filling under floors under paver block, thickness not exc 50 mm including consolidation complete all as specified and as directed
DEB AND COMPANY
UNIVERSAL TRADING CENTRE
MAZUMDER ENTERPRISE
dutta and dutta
ARJUN DAS VALECHA
BASU AND CO
Somani Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .