Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹41.3 L+₹2.9 L (7.48%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹42.1 L+₹3.7 L (9.51%)Rejected-Finance NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹42.2 L+₹3.7 L (9.67%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹42.4 L+₹3.9 L (10.2%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
24 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Chabua
Office of GE (AF) Chabua Pin-786102
As per BOQ details
2024_MES_669487_1
612/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Balijan
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Chabua
₹76,000
Yes
21 Oct 2024
2 Sept 2024
26 Sept 2024
2 Sept 2024
24 Sept 2024
17 Sept 2024
Amount
Taking down old unsv corroded / rusted GI pipe ofs size upto 20 mm bore complete all as specified and directed at site.
All as per ser item no 01 here in before but size of GI pipe 25 mm bore
All as per ser item no 01 here in before but size of GI pipe 32 mm bore
All as per ser item no 01 here in before but size of GI pipe 40 mm bore
All as per ser item no 01 here in before but size of GI pipe 50/63 mm bore
All as per ser item no 01 here in before but size of GI pipe 80 mm bore
All as per ser item no 01 here in before but size of GI pipe 100 mm bore
S& laying 25 mm bore 3 layer PP-R (Polypropylene Random Copolymer)pipes, SDR-7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded poly propylene fittings fixed complete to walls ceiling or in floors complete all as specified and as directed. (Note : - Exc & earth work if required will be measured and paid seperately)
All as per ser item No 08 here in before but size of PP-R pipe 32 mm bore
All as per ser item No 08 here in before but size of PP-R pipe 40 mm bore
All as per ser item No 08 here in before but size of PP-R pipe 50 mm bore
All as per ser item No 08 here in before but size of PP-R pipe 63 mm bore
All as per ser item No 08 here in before but size of PP-R pipe 90 mm bore
All as per ser item No 08 here in before but size of PP-R pipe 110 mm bore
S&F GI pipe medium grade galvanised, with all fittings laid in trenches of size 20 mm bore complete all as specified and as directed at site. (Note : - Exc & earth work if required will be measured and paid seperately)
All as per ser item No 15 here in before but size of pipe 25 mm bore
All as per ser item No 15 here in before but size of pipe 32 mm bore
All as per ser item No 15 here in before but size of pipe 40 mm bore
All as per ser item No 15 here in before but size of pipe 50 mm bore
All as per ser item No 15 here in before but size of pipe 80 mm bore
All as per ser item No 15 here in before but size of pipe 100 mm bore
Supply and fixing in repairs 25 mm bore PP-R gate valves (brass insert) as per site requirement of the site complete all as specified and directed at site.
All as per ser item No 22 here in before but size of PP-R gate valve 32 mm
All as per ser item No 22 here in before but size of PP-R gate valve 40 mm
All as per ser item No 22 here in before but size of PP-R gate valve 50 mm
All as per ser item No 22 here in before but size of PP-R gate valve 63 mm
All as per ser item No 22 here in before but size of PP-R gate valve 90 mm
All as per ser item No 22 here in before but size of PP-R gate valve 110 mm
Supply and fixing in repairs 25 mm bore PP-R Ball Valves (brass insert) as per site requirement of the site complete all as specified and directed at site.
Supply and fixing in repairs 32 mm bore PP-R Ball Valves (brass insert) as per site requirement of the site complete all as specified and directed at site.
Supply and fixing in repairs 40 mm bore PP-R Ball Valves (brass insert) as per site requirement of the site complete all as specified and directed at site.
Supply and fixing in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 20 mm bore pipe.
All as per ser item No 32 here in before but size of gate valve 25 mm
All as per ser item No 32 here in before but size of gate valve 32 mm
All as per ser item No 32 here in before but size of gate valve 40 mm
All as per ser item No 32 here in before but size of gate valve 50 mm
Supply and fixing in replacement, sluice valve with cast iron body and gun metal/steel spindle and hand operated iron wheel, both ends flanged and drilled including nuts,bolts,washers and gaskets,PN 1.6 ISI Marked of 80 mm bore size all as specified and directed by Engr-in-Charge.
All as per ser item 37 here in before but of size 100 mm bore.
Testing of water sample as per IS-10500, water sample collection from distribution point and getting tested at approved district testing laboratory once in every 03 months or as directed by Engr-in-Charge complete all as specified and directed at site.
Supply, fiixing, testing and commissioning pressed steel plates of size 1.25 m x 1.25 m x 6 mm thick on existing PS OH Tank installed on 40' to 50' height staging with required number of holes on the plates according to existing plate of PS tank incluiding all necessary joining materials i.e. lead wire, tape, lead wool, gasket, putty/jointing compound, new machine made bolts, nuts, washers, MS cleat etc of required size to make the joining portion absolutly leak proof complete including painting of two coats of lead free black bituminous paint suitable for storage of drinking water internally and two coats of Alluminium paint over one coat of red oxide zink chrome primer externally including preparation of surface and refixing/reconnecting of existing pipe line connection, complete all as specified and as directed. (Note : cost of staging/working platform involved shall be deemed to be included in the unit rate quoted.)
Opening of top and bottom cover of pressure feed type filteration plants 5000 to 10000 gallons capacity per hours, taking out old filter media including old strainer etc and removing and disposing at nearest dump all as directed by Engineer-in-Charge.
Scraping and cleaning the surface bed, inner and outer surfaces of the IR plant shell for complete removal of scales, rust, old paint etc and painting with two coats of anti corrosive bituminous lead free paint suitable for storage of potable water (for internal surfaces) and two coats of aluminium paint for external surfaces and two coats of synthetic enamel paint with connected valves,frontel pipes as per colour code and write (size of lettering 65 mm height) on indicated space ie. DATE OF CHANGING FILTER MEDIA............., CAPACITY OF TANK ...........,MES NO ............,SM NO ........etc.) in white synthetic enamel paint over black back ground synthetic enamel paint of 10000 gallons capacity filtration plant complete all as directed.
Supply and fixing in repairs of strainer, PP/LDPE double deck type PP(3/8" or 1/2") suitable for filtration plant, complete all as specified and as directed.
Supplying and charging in layers special coarse sand( Barakar sand) suitable for use in filtration plant of size 1/8'' x 1/16'' mesh, complete all as specified and as directed at site.
All as per ser item No 44 here in before but 1/16'' x 1/24'' mesh complete all as specified and directed at site.
Supplying and charging in layers new washed, cleaned, dust free graded gravels filter media suitable for use in filtration plant of size above 20 mm to 40 mm complete all as specified and directed at site.
All as per ser item No 46 here in before but size above 12 mm to 20 mm complete all as specified and directed at site.
All as per ser item No 46 here in before but size above 6 mm to 12 mm complete all as specified and directed at site.
All as per ser item No 46 here in before but size above 3 mm to 6 mm complete all as specified and directed at site.
Note for item no. 46 to 49 : (i) Before charging of filter media contractor shall carry out raw water testing for all parameters. (ii) After complition of the change of filter midia the treated water is to be send for water testing for all parameters with in 10 days. (iii) All testing connected with water should be done from Govt/Govt approved laboratory . (iv) The water testing cost is demed to be included in quoted rates.
Supply and charging in layers Manganese dioxide(MnO2) of approximate sizes 20 mm to 25 mm containing at least 65% of manganese, suitable for use in filtration plant complete all as specified and as directed by Engineer-in-Charge. Make : RMCO/Blue stone / Global Absorbent, NOTE : Samples of raw material (MNO2) should be got tested in Govt approved laboratory before using in the oxidation chamber for determining the MNO2 purity, which shall not be less than 65% ((MNO2 contents minimum 65% purity), testing charge for the same is deemed to be included in the cost quoted by the controctor.
Supply and fixing in repair butterfly valve 80 mm bore including taking out old valve complete all as specified and as directed.Make-RMCO
Supply and fixing in repair butterfly valve 100 mm bore including taking out old valve complete all as specified and as directed.Make-RMCO
Material and labour for Cleaning, desludging and removing of all scales and dirt from external surface of OH Pressed Steel Tank of capacity 9600 gallons installed at height of 40' staging by complete removal of old paint/ rust by applying detergent and scrapping / wire brushing/sand papering and washing with clear water and painting of external/internnal surface of PS OH tank complete with two coats of aluminium paint over a coat of red oxide primer including painting of structure and connected all pipe lines (rising mains and delivery lines) from tank as per colour coading and write (Size of lettering 75 mm height) on indicated space at a height 3.5 mtr from ground level (ie. DATE OF CLEANING................, CAPACITY OF TANK ..................etc.) in black synthetic paint over white synthetic enamel paint all as directed and specified. NOTE : (a) Cost of staging/working platform involved shall be deemed to be included in the unit rate quoted. (b) consumption of bleaching powder for cleaning of each tank shall not be less than 12 Kg (c)Maximum two times cleaning of each tank in entire C.A. period.(Measured separately each time) (d) Work shall be carried out in safety norms and all safety shall be provided by the contractor and no extra claim shall be admissable at later stage.
Construction of brick masonry valve pit / chember of internal dimension 90 cm x 90 cm x 90 cm depth with sub class 'B' old size bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 6 mm angle iron 3 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary breaking of the existing old chember, excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m, complete all as specified and as directed by Engr-in-Charge.
All as per item No. 55 here-in-before above but valve pit chamber of internal dimension size 60 x 60 x 60 cm, complete all as specified and as directed by Engr-in-Charge..
Attending emergency breakdown of water supply installation where directed, taking out defective submersible pump set of capacity 15HP/ 20 HP incl column pipes from bore well, transporting pump set from site to work shop for repairs and back and lowering the pump set incl column pipes and making water and electric connection as per existing for running of pump motors complete all as directed by Engr-in-Charge.(Note:- Spare Parts shall be measured & paid under relevant items).
Rewinding of stator of submersible motor for 20 HP capacity with water proof insulated copper wire of existing guage to achieve the specified/required RPM including taking out old unserviceable winding ,complete all as specified and as directed
Repairing of joints of plates in position by loosing the jointing bolts, unscrewing jointing materials such as lead wire/tapes, lead wool gasket, bituminous compound and replacing with new matching made bolts, nuts, washers bituminous compound suitable for potable water and MS cleats wherever required complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Taking up GI water mains from trenches for repair/rectification of leakage of GI water line of sizes 20 to 25 mm dia including bailing out water, mud etc and relaying the same after repair in position and testing of leakage complete all as specified and directed by Engineer-in-Charge. Note: Excavation & earthwork will be measured and paid for separately but GI fitting and jointing material deemed to be included in the quoted rate.
Taking up GI water mains from trenches/wall for repair/rectification of leakage of GI water line of sizes 40 to 50 mm dia including bailing out water, mud etc and relaying the same after repair in position and testing of leakage complete all as specified and directed by Engineer-in-Charge. Note: Excavation & earthwork will be measured and paid for separately but GI fitting and jointing material deemed to be included in the quoted rate.
Taking up GI water mains from trenches/wall for repair/rectification of leakage of GI water line of sizes 80 to 100 mm dia including bailing out water, mud etc and relaying the same after repair in position and testing of leakage complete all as specified and directed by Engineer-in-Charge. Note: Excavation & earthwork will be measured and paid for separately but GI fitting and jointing material deemed to be included in the quoted rate.
S&F in repairs Fully Automatic Star Delta Starter in sheet steel Enclosure with contactor & Pneumatic timers, 3 phase 415 volts, Relay range (15-22 Amps) suitable of 20 HP pump , and connection , testing ,complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair heavy duty PVC coated wire rope of size 10 mm dia suitable for 3 phase 15/20 HP Sumersible pump set complete all as specified and directed at site.
Supply and fix in replacement of flat 3 core 4 sqmm PVC insulated & PVC sheathed cable suitable for 3 phase 15/20 HP sumersible pump set complete all as specified and directed at site
M&L for repair to electromagnetic sodium/chlorine dosing pump of cap 2 Ltr/hr by replacement of unsv parts for smooth functioning of dozing pumps at directed and testing upto entire satisfaction of Engr-in-Charge .Note (i)The rate of spare parts such as stroke knob,inlet outlet PVC nozzle,PVC block,taflon washer,Circuit board PLC,valve ,strainer, foot valve ,high density polythene pipe,injection check valve,adopter with connected nut,NRV etc included in quotated rate (ii) Any repairs involved to make the dosing pump motor completly functional,even if not notified by the EIC ,shall be carried out by the contractor without any extra cost to the department.
Supply and chlorination of calcium hypochiarite Granules (65-70%) as per IS complete all as specified and directed at site. Make : Purichlor or equivalent of approved make
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc . Removing materials to store for keeping in safe custody or for taking credit ( credit a for above items should be made as per condition seperately ) and making good distrubed surfaces of walls, floors etc.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface all as specified and directed at site.
M&L for point wiring with 2.5 Sq mm single core PVC insulated FRLSH unsheathed copper multi stranded conductor in and including PVC casing capping of size 20/25mm ISI marked inclusive of tees ,bend ,elbows etc including sunk Anodized pressed steel box 1.6 mm thick concealed in wall with white laminated colour 3 mm thick sheet cover of suitable size complete including PVC insulated multi stranded copper conductor 2.5 Sq mm as earth wire to common earth dolly for connection to ceiling rose to earth terminal incl cutting, chasses and making good disturbed surface to match with existing finish with plaster for One light /Fan/bell point controlled by one one way switch complete all as specified and directed at site.
All as per ser item No.74 here-in-before but one 3 pin socket out let 5 Amps on the same board
All as per ser item No.74 here-in-before but point wiring with 2.5 sqmm for one 3 pin socket out let 5 Amps on the Independent board
All as per Srl items No.74 here-in-before but point wiring with 2.5 Sqmm for 15 Amp socket out let with 2.5 sqmm earth continuity wire.
All as per Srl items No.74 here-in-before but point wiring with 4 Sqmm for Heater or lectric equipment/ AC 1.5 / 2 Ton / more than or equal to 3 KW load with 4.0 sqmm earth continuity wire.
All as per item No.74 above but for one bell/ buzzer point with 1.5 sqmm copper wire controlled by one push button on the independent board
M&L for point wiring with 2.5 Sq mm single core PVC insulated unsheathed copper multi stranded conductor including MMS Concealed PVC Conduit of size 20/25 mm ISI marked as per site requirement inclusive of tees ,bend ,elbows etc including modular sunken steel box as per IS specification concealed in wall for housing for modular switch socket etc with modular plate with frame of suitable size complete including PVC insulated multi stranded copper conductor 2.5 Sq mm as earth wire to common earth dolly for connection to ceiling rose to earth terminal incl cutting, chasses and making good disturbed surface to match with existing finish with plaster for One light /Fan point controlled by one one way switch complete all as specified and directed at site.
All as per ser item No.80 here-in-before but one 3pin socket out let 5 Amps on the same board
All as per ser item No. 80 here-in-before but one 3pin socket out let 5 Amps on the Independent board
All as per ser item No.80 here-in-before but one bell/buzzer point controlled by one push botton on the Independent board
All as per ser item No.80 here-in-before but One light point controlled by two way switches with cables 1.5 Sqmm size
All as per Srl items No.80 here-in-before but point wiring with 2.5 Sqmm for 15 Amps Socket out let with 2.5 sqmm earth continuity.
All as per Srl items No.80 here-in-before but point wiring with 4 Sqmm for AC Point Socket out let with 4 sqmm earth continuity.
S&F switch Piano type two way 5 amp 230 volts complete all as specified and as directed.
S&F switch bell push piano type 5 amp 230 volts complete all as specified and as directed.
S&F Switch Piano type single pole 5 amp 230 v complete all as specified and directed at site.
S&F socket outlet 2 in 1 , 5 pin, 5 amp complete all as specified and directed at site.
S&F Switch Piano type single pole 15 amp 230 v complete all as specified and directed at site.
S&F socket outlet 2 in 1 , 6 pin,5 and 15 amp complete all as specified and directed at site.
S&F ceiling rose surface type Bakelite 65x50 mm three terminals complete all as specified and directed at site.
S&Fixing stepped type electronic fan regulator flushType complete all as specified and directed at site.
S&F in repair Capacitor 2.5 mfd epoxy filled type copper wound complete all as specified and directed at site. Make : Havells/Epsco or equivalent make in MES
S&F in repair Capacitor 3.15 mfd epoxy filled type copper wound complete all as specified and directed at site. Make : Havells/Epsco or equivalent make in MES
S&F in repair Capacitor 4 mfd epoxy filled type copper wound complete all as specified and directed at site. Make : Havells/Epsco or equivalent make in MES
M&L for fancy angle holder , PVC /Polycarbonate type suitabl for B22 base LED lamp . Make : Anchor Cat Part No 39672 or equivalnet in approved make
S&F in repair switch modular type, one way, 10 ams, 1 module 230 v complete all as specified and directed at site.
S&F in repair switch modular type, one way, 20 ams, 1 module 230 v complete all as specified and directed at site.
S&F in repair socket outlet,modular type ,multipurpose,multipin, 6 amps,1 module, 230 v complete all as specified and directed at site.
S&F in repair socket outlet,modular type ,multipurpose,multipin, 6 amps/16 amps ,I module, 230 v complete all as specified and directed at site.
S&F in repair modular type fan regulator,two module, 230 v complete all as specified and directed at site.
S&F call bell Ding-Dong AC, 230 volts single pole complete all as specified and as directed.
Supply and Fixing in replacement LED light fittings 36 watt Recess Mounting type , with mounting arrangement (Recess suitable for, 2x2 Grid, Hanging) Sheet aluminium housing with high quality LGP and PMMA diffuser. Separate HPF driver suitable for Armstrong and grid ceilling LED 240 volt along with fixing arrangements all as directed
Supply and fixing in replacement surface and wall mounted LED batten fitting energy efficient fittings 20 watt complete , inluding provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of size 1.5 sqmm 2/3 core 1100Volts grade all as specified and directed.
Supply and fixing in replacement surface and wall mounted LED batten fitting energy efficient fittings 10 watt complete , inluding provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of size 1.5 sqmm 2/3 core 1100Volts grade all as specified and directed.
Supply and fix MCB DB TPN 4 way with metal door suitable for Provision of MCCB and MCB's complete all as specified and as directed.
S&F in repair MCB DB TPN 4 way with metal door suitable for Provision of incomer MCB and outgoing MCB's complete all as specified and as directed.
Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site.
Supply and fix MCB DB SPN 6 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site.
Supply and fix MCB DB SPN 4 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site.
S&F in repair MCCB 63 Amps, 415 V, 16KA 4 pole with thimbles/lugs and nut,bolts complete all as specified and as directed.
S&F in repair MCB SP 240 volt 32 Amps 'C' series 10 KA complete all as specified and directed at site.
S&F in repair MCB SP 240 volt 25 Amps 'C' series 10 KA complete all as specified and directed at site.
S&F in repair MCB SP 240 volt 20 Amps 'C' series 10 KA complete all as specified and directed at site.
S&F in repair MCB SP 240 volt 16 Amps 'C' series 10 KA complete all as specified and directed at site.
S&F in repair MCB SP 240 volt 10 Amps 'C' series 10 KA complete all as specified and directed at site.
S&F in repair MCB SP 240 volt 6 Amps 'C' series 10 KA complete all as specified and directed at site.
S&F in repair MCB DP 240 volt 63 Amps 'C' Series 10 KA complete all as specified and directed at site.
S&F in repair MCB DP 240 volt 40 Amps 'C' Series 10 KA complete all as specified and directed at site.
S&F in repair MCB DP 240 volt 32 Amps 'C' Series 10 KA complete all as specified and directed at site.
S&F in repair MCB 4P 415 volt 63 Amps 'C' Series 10 KA complete all as specified and directed at site.
S&F in repair MCB 4P 415 volt 40 Amps 'C' Series 10 KA complete all as specified and directed at site.
M&L for concealed sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in PVC Conduit of size 20/25 mm as required with 2 x 6.0 sq mm + 1x 6 sqmm earth wire.
M&L for concealed sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in PVC Conduit of size 20/25 mm as required with 2 x 4.0 sq mm + 1x 4 sqmm earth wire.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed at site.Make : Havells Ambrose /USHA Energia/CROMPTON ENERGION HS Note : Old unsv ceiling fan will be deposited to MES store yard
Supply and fix exhaust fan, steel body AC Single Phase, 230 V of size 300 mm sweep with blades and frame and louvers complete all as specified and directed at site. Note : Old unsv exhaust fan will be deposited to MES store yard. Make : Havells Terbo Force/Crompton EXHD /Usha Terbo HD
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed at site. Make/Model : Havells ( Model 250 mm Fan ventil Air DX White)/Crompton ( Brisk Air_White)/Usha ( Crisp Air VX )
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed at site.Make : Havells (Model Fabia)/Jaquar ( Model Elena prime) / V-Guard (Model Pebble) Note : Old unsv exhaust fan will be deposited to MES store yard.
Supply and fixing in replacement surface wall mounted energy efficient LED batten 20 watt, surge protection 2.5 Kv, inluding provision of PVC insulated sheathed round flexible wire complete all as specified and directed. Make : Havells model No.LHEXACP7FN1W02/Wipro Model No.DE12065/ Bajaj Model No.830414
M&L for sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface with PVC casing capping/PVC Conduit as per site requirement with 2 x 6.0 sq mm + 1x 6 sqmm earth wire.
M&L for sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface with PVC Casing caping/PVC conduit as per site requirement with 2 x 4.0 sq mm+1 x 4 sqmm earth wire.
M&L for sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface with PVC conduit Conduit as per site requirement with 2 x 1.5 sq mm+1 x 1.5 sqmm earth wire.
M &L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x 6 mm buried directly in ground verticvally to depth not less than 2.25 mtr below ground level and with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth wire of size 4.00 mm dia 7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers ,testing of completion (drawn in earth lead protection pipe light gade GI of size 15 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I connected to earthing lead with Main switch/main control board,filling with charcoal dust , and common salt , including necessary excavation and earth work in any type of soil ,perforated watering pipe,funnel with wire mesh,earth lead protection pipe light grade of size 15 mm ,PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc including taking out old unsv earthing all as specified and directed by EIC
S&F Blanking Plates for covering of MCCB DB open space complete all as specified and directed at site.
Supply and fix LED Lamps 9 w B 22 base 3 star rating suitable for batten holder
Supply and fix LED Lamps 15 w B 22 base 3 star rating suitable for batten holder
S&F in replacement steel terminal box/PVC box of size 250 mm 200 mm x 50 mm with suitable size of 3 mm thick laminated sheet cover for mounting of existing serviceable switches, sockets, fan regulator etc including making good distiurbed surface as per existing complete all as specified and directed at site. Note : Taking down & refixing of existing serviceable switch,socket,fan regulator ete included in quotated rate.
All as per Srl items No.139 here-in-before but steel terminal box of size 175 mm x 100 mm x 50 mm
All as per Srl items No.139 here-in-before but steel terminal box of size 100 mm x 100 mm x 50 mm
Material and labour for servicing of 30/35/40 KVA DG Set by carrying out the following maintenance including testing on completion at connected laod for entire satisfaction of Engr-in-Charge and complete all as specified and directed at site. (i) Draining out engine oil feom the sump by removing drain plug,cleaning the sump throughly and refilling the sump with new engine oil to required level (Note : Engine oil will be measured and paid separately as Supply only) (ii) Supply and replace complete set of fuel filters, oil filters and air filter element. (iii) Draining out complete coolant water mixture from the radiator and refilling the radiator with new coolent and water mixture with proportionate ratio (Note : coolent will be measured and paid separately as Supply only) (iv) Draining out diesel from disel tank and storing in cleaned containers,cleaning the tank throughly by removing sediments settled at the bottom and refilling the drained out diesel duly filtered. (v) Check and top up the electrolyte/distilled water in starting batterie cells to maintain the required specific gravity.Cleaning of battery terminals & applying petroleum jelly to battery poles & brass connectors. (vi) Tightening all the fasteners of complete DG set to the required torque. (vii)Tightening of all gaskets, connection of battery terminals, cable connections, foundation bolts, coupling bolts etc including test running and tappet setting of alternator by checking and setting of voltage and frequencies complete.
All as per ser item No 142 here-in-before but Cap of DG Set 100 KVA
All as per ser item No 142 here-in-before but Cap of DG Set 160 KVA
Supply only disel filter suitable for 30/35/40 KVA DG set complete all as specified and directed at site.
Supply only disel filter suitable for 100 kVA DG set complete all as specified and directed at site.
Supply only disel filter suitable for 160 kVA DG set complete all as specified and directed at site.
Supply only oil filter suitable for 30/35/40 KVA DG set complete all as specified and directed at site.
Supply only oil filter suitable for 100 kVA DG set complete all as specified and directed at site.
Supply only oil filter suitable for 160 kVA DG set complete all as specified and directed at site.
Supply only air filter suitable for 30/35/40 KVA DG set complete all as specified and directed at site.
Supply only air filter suitable for 100 kVA DG set complete all as specified and directed at site.
Supply only air filter suitable for 160 kVA DG set complete all as specified and directed at site.
Supply and fixing battery lead with stranded copper conductor of size 95/70 sqmm single core PVC insulated flexible 0.6 M long along with battery terminal for positive and stator terminal duly soldered all as directed.
M&L for drain out the old unsv engine oil from sump of DG sets & cleaning &n refilling with new engine oil 15 W 40 up to required level including top up complete all as specified and directed at site.
M&L for drain out old coolant from radiator and topup of best quality pre mixed coolants in radiator of any capacity DG set complete all as specified and directed at site.
M&L for top up of distilled water in DG set battery as per required level complete all as specified and directed at site.
De-scaling of radiator assembly by carefully from the engine,transporting to civil workshop and removing the sediments,scales and rust etc by means of chemical cleaning,high pressure water washing and air cleaning, arresting the leakages by gas welding/soldering with suitable material, and re-assembling the same with new gaskets including replacement of radiator cap(whereever required) and transporting to the site, fixing to the engine for DG set of capcity 30/35/40 KV and testing for satisfactory performance complete all as specified and directecd at site.
All as per ser item No 158 here-in-before but Cap of DG Set 100 KVA
All as per ser item No 158 here-in-before but Cap of DG Set 160 KVA
Dismantling the defective water pump assembly and supply and fix new water pump assembly suitable for existing DG set of capacity 30/35/40 KV complete all as specified and directed at site.
All as per ser item No161 here-in-before but Cap of DG Set 160 KVA
Dismantling the defective fuel injectors & FIP from the engine and material and labour for repair/calibration of fuel injectors , nozzle repair with pressure check including replacement of barrel plunger,Nozzels,)element,dilevery valve, Injector,cups,'O' rings etc as per site requirement of 30/35/40 KVA DG set complete all as specified and directed at site.
All as per ser item No 163 here-in-before but Cap of DG Set 160 KVA
Supply and fixing oil temp sensor suitable for DG set of cap 160 KVA Make : Kirloskar/CG/Graves complete all as specified and directed at site.
Supply and fixing in repair solenoid coil suitable for DG set of capacity 100 to 160 KVA complete all as specified and directed at site.
M&L in replacement diesel pipe metal mesh types both side connecting arrangement of length as required on site suitable for 30 to 40 KVA Dg Set complete all as specified and directed.
M&L in replacement diesel pipe metal mesh types both side connecting arrangement of length as required on site suitable for 160 KVA Dg Set complete all as specified and directed.
M&L in replacement AC Pump/PT Pump suitable for 160 KVA any type DG Set complete all as specified and directed.
M& Labour in repair of self starter 12 volt ,dismantling from DG set of Cap 100 KVA and shifting to workshop and back for and including replacement of spare parts such as armature,housing bush,solonoid switch,pinion,pinion lock,rocker, rocker cap bush, frog, frog adjustment bolt,field coil,carbon brush,,armatur shat/comutator shaft ,adjusting bolt, centre plate bush,comutator fiber/steel washer carrying out following repair works. Note: Spares to be included quotated rate please.
Supply and fix in replacement AVR suitable for 100 KVA DG Set complete complete all as specified and directed.
All as per ser item No 171 here-in-before but Cap of DG Set 160 KVA
Supply and fix in replacement of RRA suitable for 100 to 160 KVA DG Set complete complete all as specified and directed.
Supply and fixing in repair actuator suitable for DG set of capacity 100 to 160 KVA complete all as specified and directed at site.
M&L for complete painting of 30/35/40 KVA DG set of make:- Kirloskar with alternator ,base plate by using heat resistant paint with spray gun over existing surface as per existing colour code after taking out old paint ,dirt and dust from the DG set body, alternator and engine complete all as specified and directed by Engr-in-Charge.
All as per ser item No 175 here-in-before but Cap of DG Set 100 KVA
All as per ser item No 175 here-in-before but Cap of DG Set 160 KVA
Dismantling the complete cylinder head assembly/Engine block of 100 to 160 KVA DG Set as per site requirement and shifting to auth workshop for any type of lath work,any type of addn/ alteration,Cylinder head polish and transport to back for carrying out following under mention repair /replacement of spares :- Note : Spare parts to be measured and paid and separately.
Engine Gasket complete
Head Gasket complete
Rocker Gasket complete
Oil sump gasket complete
Supply and fix in replacement of Turbo charger suitable for 160 KVA Generator set of any ,make and type complete all as per specified and directed at site.
Supply and fix in replacement of radiator Cooling Fan pulley suitable for DG Set of cap 160 KVA complete all as specified and directed at site.
Supply and fix in replacement of radiator fan suitable for DG Set of cap 160 KVA complete all as specified and directed at site.
Supply and fix in replacement of engine mounting vibrating pad suitable for 160 KVA DG Set complete all as specified and directed at site.
Servicing of AMF panel of DG Set 100KVA to 160 KVA by OEM i.e auth dealer of installed at AF Stn Chabua by cleaning the complete panel with suitable cleaning agennt,removing dust particles by using high speed blower and checking the controller relays,timer, contactors for proper functioning,replacing defective spare parts,replacement of defective wires of exixting size up to 2 mtr,tightening of all connections and applying jelly on contractors complete all as specified and directed by Engr-in-Charge Note : Spare parts required will be measured and paid separately as supply only but cost of small wire s shall be included in the quotated rates.
Supply only logic controller relay complete assembly
Supply only control relay
Supply only timer
Supply only battery charging unit 12/24 volts.
Auto/manual switch complete assembly
Start/stop push button
M & L for repair/rewinding of Battery charging Alternator Heavy duty 24 volt with super enamelled/ paper coated copper wire of existing gauge incluiding all connected insulating material such as separator etc, varnishing, replacement of carbon bushes including disconnection/dismantling of electrical connections, foundation bolts, pulling out and reinsulation of burnt out winding after rewinding work including re-assembling and testing complete all as directed.
S & F in repair hinges of doors of DG set of any capacity including welding of defective portion and provision of fixing of new MS hinges of suitable size for hanging of door complete all as directed by Engr-in -charge.
Supply and fix in replacement of radiator hose pipe set with hose clip suitable for 30/35/40 kVA DG set all as specified and directed at site.
Supply and fix in replacement of radiator hose pipe set with hose clip suitable for 160 kVA DG set all as specified and directed at site.
Supply and fix in replacement of Fan belts suitable for 30/35/40 KVA DG Set
Supply and fix in replacement of Fan belts suitable for 160 KVA DG Set
Supply and fix in replacement of thermostate valve suitable for 30/35/40 KVA DG Set complete all as specified and directed at site.
Supply and fix in replacement of thermostate valve suitable for 160 KVA DG Set complete all as specified and directed at site.
Supply and fix in replacement self starte assembly 24 volt suitable for 160 KVA DG Set complete all as specified and as directed.
Supply and fix in replacement of battery 12 volt, 150 AH, of Make : Exide or equivalent model of Make : Amron/Sukom.
Supply and fix in replacement of battery 12 volt, 90/100 AH, of Make : Exide or equivalent model of Make : Amron/Sukom.
M & L for rewinding of Stator/Rotor coil of alternator/Rectifier Coil Unit of DG set with super enamelled/ paper coated copper wire of existing gauge incluiding all connected insulating material such as separator etc, varnishing, replacement of carbon bushes including disconnection/dismantling of electrical connections, foundation bolts, pulling out of rotor with proper care and reinsulation of burnt out rotor/stator after rewinding work including re-assembling and testing complete all as directed.
M & L for maintenance free chemical earthing system complete with 03 (three) nos copper bonded rods, 17.2 mm dia 3000 mm long electrode buried at suitable distance apart directly in ground, to bore holes of 120 mm dia vertically to a depth not less than 3.60 mtr deep below ground level with top edge of earth electrode at a depth not less than 100 mm below normal ground level, provision of clamps or brazed or both for each copper bonded rods made of copper and copper strip of size 25 x 3 mm & strip connection on the top of the electrode and copper strip of size 25 x 3 mm for inter connection of 03 nos copper bonded rods and laying at least 500 mm below in the ground and further connected to test point terminal block (copper strip and test terminal block shall be measured separately), including back filling of bore holes with advanched earth enhancing compound 96 kilogram (minimum) of Make : Erico or equivalent of Macmet/True Power/Ennov for artificial treatment to soil so as to achieve earth resistance below 01 Ohms as specified in para 19.140 of SSR Part-1 (2009), including provision of earthing pit in PCC(1:3:6) type C1 pre-cast cover RCC slab of size 400 x 400 x 50 mm with one handle made out of 8 mm dia round bar, including necessary earth work and three coats of white wash on plastered surface (exposed surfaces) and testing complete all as directed and including necessary earth work and testing complete all as specified and directed. Note:-Taking down old unservicible dipilated chemical earthing are included in quated rate.
M/s HALDER ENTERPRISE (BID ID -3103623)
MAA COMMUNICATION (BID ID -3105408)
M/s PRABIR ENTERPRISE (BID ID -3101761)
STANDARD ELECTRIC WINDERS (BID ID -3105699)
J D construction (BID ID -3105402)
FREEZCON (BID ID -3103160)
NChetia and Sons Trading (BID ID -3105610)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .