| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹46.7 LAccepted-AOC 1000 PUDA MODEL TOWN PHASE 5 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L-1 | Accepted-AOC Being lowest and reasonable. | |
| 2 | L-2₹50.9 L+₹4.2 L (8.99%)Rejected-Finance HOUSE NO 8 589 BEHIND PHC HOSPITAL OLD BUS STAND KORBA KORBA CHHATTISGARH 495678 | 495678 | L-2 | Rejected-Finance Not being lowest bidder. | |
| 3 | L-3₹52.0 L+₹5.3 L (11.5%)Rejected-Finance 4943 OPP JAIN JEWELLERS POST OFFICE BAZAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L-3 | Rejected-Finance Not being lowest bidder. | |
| 4 | L-4₹55.8 L+₹9.1 L (19.5%)Rejected-Finance 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L-4 | Rejected-Finance Not being lowest bidder. | |
| 5 | L-5₹58.3 L+₹11.6 L (24.8%)Rejected-Finance H NO 17036 9 STREET NO 5 A AGGARWAL COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L-5 | Rejected-Finance Not being lowest bidder. |
Tender Value
₹77.5 L
EMD Value
₹1.4 L
Closing Date
23 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bathinda
HQ CWE Bathinda Bathinda Mil Stn
PROVISION OF CERTAIN SANCTIONED WORKS UNDER GE (N) BATHINDA AT BATHINDA MIL STN
2023_MES_632589_2
CWE BTD/TOKEN-47/2023-24
Open Tender
Civil Works
Item Rate
270 days
Bathinda Mil Stn
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (North) Bathinda
₹1.4 L
HQ CWE Bathinda
15 May 2024
24 Jan 2024
26 Feb 2024
24 Jan 2024
23 Feb 2024
16 Feb 2024
10 Feb 2024
Amount
Dismantling brick/PCC terracing tiles single layer in roof laid and pointed in cement mortar and removing/disposal off from the site complete all as specified and as directed by Engineer-in-charge.
Demolition of mud in roofs, any thickness, including plastering and leaping (whether full thickness removed or only a part there of) including removing/cutting uprooting grass, vegetations and roots of small plants etc on roof floor and surrounding/parapit wall etc, including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge.
Material and labour for rendering 15mm thick cement mortar 1:4 mixing with and including Water Proof Compound @ 3% by weight of cement on fair faces of concrete surfaces on roof slab after wire brushing and cleaning top surfaces of cement concrete all as specified and wire brushing and cleaning top surfaces of tile, lime terracing or cement concrete, including flashings and junction of parapets etc. and surface painting, with a layer of blown bitumen of any penetration applied hot @ 1.70 Kg/Sqm and priming surface and applying APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum thick 3mm reinforced with polyster non wove fabric (Weight not less than 150 gm/Sqm ) laid over primed surface by forced application as treatment (for moderate conditions) complete all as specified and as directed by Engineer-in-charge.
Material and labour for lime concrete terracing using brick aggregate and surkhi as specified in clause 11.11 and laying as specified in clause 11.27 of MES Sch Part-I (2009) minimum thickness at edge 40mm and increasing uniformly towards ridges to obtain a chain slope 1:40, the top shall be trowelled with the addition of jaggery solution and finished smooth complete all as specified and as directed by Engineer-in-charge.
Material and labour for 40mm thick brick tiles laid / bedded over and incuding 15mm thick screed bed in cement mortar 1:6, over existing lime concrete surfaces of roof, including joints grouted flush in cement mortar 1:3 mixed with and including liquid WPC @ 200ml per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and as directed by Engineer-in-Charge. Note :- Liquid Water proofing compound shall be measured & paid separately as Supply only under respective item of Schedule'A' BoQ
All as per serial item No. 5 here-in-before but except brick tiles. Note : Old serviceable brick tiles shall be used after cleaning and removing of any mortar retrieved from serial item No 1 here-in-before
Supply only liquid water proofing compound ISI Marked.
Material and labour for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed by the Engineer-in-Charge.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for rendering/plastering 10mm thick in cement mortar (1:3) on any face of ceiling, finished fair and even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for vitrified ceramic coloured tiles (Light shade) 10 mm thick square or rectangular area of each tile not exceeding 0.36 sqm, as in floor, set and jointed in neat cement slurry @ 3.00 Kg/ Per Sqm and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for vitrified ceramic coloured tiles (light shade) 10mm thick square or rectangular area of each tile not exceeding 0.36 sqm, as in skirting, dado etc. set and jointed in neat cement slurry @ 3.00 Kg/ Per Sqm and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor, set and jointed in neat cement slurry @ 3.00 Kg/ Per Sqm and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Glazed ceramic coloured tiles of size 300mmx 200mm / 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry @ 3.00 Kg/ Per Sqm and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete reinforced of any discription and in any position, including reinforcement cut as required to facilitate and including removing rubbish material from site and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-charge
Material and labour for reinforced cement concrete M-25 Design Mix using 20mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for form work to flat sides and soffits of floor or roof beams, beam haunchings , lintels, cantilevers, shelves including supports, overhangs, sides of chajjas etc and similar works rough finished flat surfaces complete all as specified & directed by Engineer-in- charge.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose)
Material and labour for preparing newly plastered or concrete surface of ceiling using by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
Material and labour for Preparation of old decorated surfaces (plastered/unplastered) of ceiling by remove / scraping down all smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc with using broom / steel patti / wire brush / sand papering or by any other mean including applying white cement based putty where required for filling to depressions to make the surface even and smooth upto entire satisfaction of Engineer-in-charge, and after preparing the surface smooth applying one coat of lime white wash with paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) and efflorescence from old decorated surface of walls/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming down and preparing the surfaces smooth and make good by applying average 3mm thick layer (1.5mm thick each in two layer application ) of white cement based wall care putty as approved by Engineer-in-charge) and sanding the surface by using mechanical sander machine to make the even and smooth upto entire satisfaction of Engineer-in-charge and after that applying two coats of oil emulsion distemper (washable), as approved tint/colour by using paint roller brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for newly plastered of walls applying two coats of oil bound distemper (washable) over a coat of alkali resistant priming paint on plastered surfaces complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as per approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls / pillars / cornices by scraping down with using steel patti wire/ brush / sand papering or by any other mean, remove / scraping down all loose particle, smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc brooming all dust and washing down with water including applying white cement based putty where required for filling to depressions/nail holes/light cracks etc and to make surface even and smooth and also using sander machine (with provision of dust sucking) on uneven surface to make the surface even and smooth (before and after applying putty as per site situation) upto entire satisfaction of Engineer-in-charge, and after preparing the surface smooth applying two coats of cement base paint as per approved tint/colour with using paint brush/roller brush, complete all as specified and as directed by Engineer-in-Charge. NOTE : - Complete removal /scraping to old existing treatment as directed by Engineer-in-charge, each stage i.e after complete removal and before applying CBP as specified above, the surface shall be passed in writing by the Enigineer-in-charge in site order book.
Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size fly ash bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour Brickwork with subclas 'B' fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames, wooden /PVC door s/steel ventilator) area not exceeding 1.50 sqm each complete all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each complete all as specified and as directed by Engineer-in- charge.
Taking down wooden shutters only of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm each complete all as specified and as directed by Engineer-in- charge.
Re-fixing in same opening shutters area exceeding 1.0 sqm and not exceeding 2.0 sqm (serviceable shutters) each complete all as specified and as directed by Engineer-in- charge.
Supply and fixing factory made 105mm x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including one shop coat of zinc chromate primer paint including supply and fixing necessary lugs and lock strike plate, etc. , including fixing butt hinges suitable Nos. as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
Supply & fixing factory made plain framed panelled shutters (two panels as approved), 35mm thick of 2nd class hard wood with lock rail and panel inserts of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I), kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401, including 2nd class soft wood kail beading 20mm wide tapering from 10mm to 5mm on one side and also fitted to chowkhat complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ.
Supply and fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, fixed in opening using MS screw 75mm long with PVC fastener including making good disturbed wall surfaces (brick, plastering, tiles and painting work as per existing) complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. complete all as specified and as directed by Engineer-in-Charge.
Supply only 100 mm long Butt hinges, heavy weight, cold rolled mild steel, and fixed complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 125mm long, Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 150mm long, Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engineer-in- charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 200mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 150mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing aluminium anodised sliding door bolts 250mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed by Engineer-in- charge.
Supply & fixing for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-in- charge.
Supply and fixing 4mm thick sheet glass ordinary quality & glazing with oil putty in square not exceeding 0.5sqm in each pane complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of old wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified & directed by Engineer-in- charge.
Material & Labour for Cast iron floor trap 100mm bore, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and as directed by Engineer-in- charge.
Supply & fixing aluminium anodised frame, made out of aluminium section / aluminium chanel, powder coated (minimum thickness of powder coating not less than 50 micron), for doors, windows, ventilators with one or more rebate including jointing cleat for fixing etc. complete all as specified and as directed by Engineer-in-Charge. Note :- Weight of aluminium section/aluminium channel shall be physically ascertained through a board of officers convened by Accepting officer and payment shall be made only after the actual weight at site.
Supply & fixing anodised aluminium door shutter, made out of aluminium section weighing 0.55 Kg/mtr, powder coated (minimum thickness of powder coating not less than 50 micron) including aluminium hardware i.e. necessary joining cleats, glazing clips, rubber neoprene packing, suitable size of aluminium handles 2 Nos and aluminium hinges 04 Nos in each leaf (size of handle and hinge as directed), anodised aluminium snap beading, screws etc including fixing of glass, complete all as specified and directed by Engineer-in-Charge. Note :- (i) Aluminium chowkhat frame shall be measured and paid separately under appropriate item of BOQ as supply and fixing. (ii) Glass and other filling material in panels shall be measured and paid separately under appropriate item of BOQ as supply only.
Supply & fixing anodised aluminium window/ventilator shutter side hung type without sash bars, made out of aluminium section weighing 0.55 Kg/mtr, powder coated (minimum thickness of powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 No. for ventilator and 3 Nos for window each shutter) suitable handle (1 No.), including fixing of glass, complete all as specified and directed by Engineer-in-Charge. Note :- (i) Aluminium chowkhat frame shall be measured and paid separately under appropriate item of BOQ as supply and fixing. (ii) Glass and other filling material in panels shall be measured and paid separately under appropriate item of BOQ as supply only.
Supply and fixing 5mm thick sheet glass ordinary quality & glazing with oil putty in square exceeding 0.5sqm in each pane complete all as specified & directed by Engineer-in- charge.
Supply & fixing aluminium (Die cast) body door closer hydraulically regulated, designation No 3, universal type suitable for door shutter of 851 to 1000mm in width and weight between 61 to 80 Kg, ISI marked complete all as specified & directed by Engineer-in-charge.
Supply and fixing in replacement 10 litres capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handle including brackets and 32mm dia PVC flush pipe complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair 600 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply and fixing 100mm bore cast iron trap, 'P' or 'S', complete all as specified and directed by Engineer-in-Charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and directed by Engineer-in-charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed ) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in replacement bib tap cast copper alloy, chromium plated with crutch or butterfly handle with capstan head, wall flange, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing in replacement stop valve/angle valve cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixed in repair pillar tap cast copper alloy with capstan head, chromium plated, fancy type, high pressure with or without letter 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
Supply and fixed in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Supply & fixing 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing Grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40gms) complete all as specified and as directed by Engineer-in-charge.
Supply & fixing stainless steel sink with drainage board made out of 1.00mm thick sheet , kitchen or laboratory with plugs, washers, waste pipe including bedding in cement mortar to dwarf wall or fixing cast iron cantilever brackets and connecting union to waste pipe; overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm including taking down existing chinaware sink complete all as specified and directed by Engineer-in-Charge.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and fixing ball valve and gate valve including dismantling/taking down of existing unserviceable PVC water storage tanks of any description complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply & fixing in repair vitreous china wash basin, white, table top , fancy type, including 32mm chromium plated waste coupling and PVC waste pipe including bracket and cutting for and pinning in end of bracket or erecting complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement vitreous china urinal, half stall type, white, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling and 32mm dia waste pipe and pointing around urinal back in cement mortar,complete all as specified & directed by Engineer-in-charge.
Dismantling wall and ceiling board (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets fixed in any position with nails fixed with screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing anodised aluminium snap grid frame work of size of grid 605mm x 605mm for false ceiling including necessary notching and prepared holes, the snap grid shall consist of anodised aluminium main tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM, cross and Intermediate tee of size 23.5mm x 26.4mm x 1.4mm weighing 0.191 Kg/RM. The main and cross tee shall be jointed at junction with steel screws or MS bolts, nuts and washers, the snap grid (main / cross tee sections) shall be supported at ends all along the wall with anodised aluminium angle of size 35mm x25mmx 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and duly suspended with 4mm GI wire hangers (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 12mm thick gypsum board in grid fixed in false ceiling grid made of aluminium as per above specifications complete all as specified and as directed by Engineer-in-charge.
Supply & fixing vitreous china wash down water closet pan (pedestal pattern, EWC) white clour (including flushing cistern and flush pipe) including connection to drain and to flushing pipe anti syphonage etc., including plastic water closet seat with cover (white or black colour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in replacement plastic water closet seat with cover (white colour) closed pattern with flat bottom/recessed bottom and mild steel chromium plated or aluminised hinging device complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in replacement stainless steel chromium plated pipe 25mm dia, wall thickness of pipe not less than 20 guage, as curtain rod fixing with and including fancy type brackets and decorated end knobs (finials), stop roller etc, fixed on wall for doors and windows curtains, cuttings as required length and fixing at site including fixing arrangements, rawl plug, screws etc. including taking out old any type rod or pelmet boxes with curtain rod complete all as specified & directed by Engineer-in- charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engineer-in- charge.
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, with one shop coat of zinc chromate primer with glazing bars including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast and making good disturbed area of walls and cills to match the existing surfces by bricks / plastering works and painting work etc complete all as specified & as directed by Engineer-in- charge.
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, with one shop coat of zinc chromate primer without glazing bars including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast and making good disturbed area of walls and cills to match the existing surfces by bricks / plastering works and painting work etc complete all as specified & as directed by Engineer-in- charge.
Supply & fixing, factory made steel ventilators all as per IS 1038/83, with top hung shutters including hinges, suitable steel handle, steel peg stay,with one shop coat of zinc chromate primer fixing lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast and making good disturbed area of walls and cills to match the existing surfces by bricks/plastering works and painting work etc complete all as specified & as directed by Engineer-in- charge.
Material and labour for steel rolling shutters push pull or manual type made out of 1.25 MM thick lath, without ball bearing, as specified including top cover, anchoring rod hasp and staple, guide channel, lock, hold fast, complete all as specified in SSR Part-I (2009) para 10.23 including PCC block, erected in position as directed including two coats of synthetic enamel paint over a coat of red oxide primer both sides on exposed surfaces including taking out old defected/rusted shutter and making good the disturbed wall surfaces (brick, plastering and painting work as per existing) complete all as specified and as directed by Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips, oil putty complete all as specified & directed by Engineer-in- charge.
Supply & fixing and cutting as per size requirement 4mm thick sheet glass ordinary quality in squares/retangular exceeding 0.5sqm in each pane and fixed in any type of doors / windows / ventilators (openable/fixed type) with fixing material complete all as specified & directed by Engineer-in- charge.
Supply & fixing and cutting as per size requirement 3mm thick sheet glass ordinary quality in squares/retangular not exceeding 0.5sqm in each pane and fixed in any type of doors / windows / ventilators (openable/fixed type) with fixing material complete all as specified & directed by Engineer-in- charge.
Supply & fixed in repair galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staples complete all as specified & directed by Engineer-in- charge.
Supply & fixing in repair hand shower (health faucet) ABS body including 1 meter long 8mm dia flexible tube and including wall hook including taking down old any type shower complete all as specified and as directed by Engineer-in-charge.
Material and labour 18-20mm thick machine cut, granite duly factory grinding and polished (table rubbed and polished) of approved colour for counter sunk wash basin, plateform/cooking plateform or as directed, including screed bed 15mm thick in cement mortar (1:4) (grey cement slurry) including pointing in white cement (1:2) using marble dust with admiture of pigment to match with shade of granite stone slab including cutting as required including cleaning and extra polishing if required complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Preparation of old steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified & directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (spun cast pipe ) in any length with or without ears, laid in trenches or in floor jointing with cement mortar, including taking out old unserviceable pipe, complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed to wall with stack clamps (interval of 1m) made out of FI 50x5mm and 16mm dia round iron stay including nut bolt and jointing with cement mortar including taking out old unserviceable pipe, complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 75 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed to wall with stack clamps (interval of 1m) made out of FI 50x5mm and 16mm dia round iron stay including nut bolt and jointing with cement mortar including taking out old unserviceable pipe, complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 100mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 75mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Cast iron floor trap 75mm bore, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in replacement 100 mm cast iron sanitary connection socket to fit out let of WC complete all as specified and directed by Engineer-in-Charge.
Supply & fixing 75mm bore cast iron cowl complete all as specified and as directed by Engineer-in- charge.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil including cutting of grass, roots, bushes if any and filling of lower portion with soil obtained from cutting and dressing complete all as specified and as directed by Engineer-in-charge.
Excavation in post holes in soft/loose soil n. exc 0.50 cum each, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25 cm including removing of surplus spoil to a distance n exc 50 mtr and making good the disturbed surfaces all as specified and directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Material and labour for hard core of broken bricks of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge.
Material and labour for PCC ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:2:4), type B-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete, sub base of sewage tank & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for 40 mm thick damp proof course in cement concrete (1:2:4) type B0 using 12.5mm graded stone aggregate) to horizontal or vertical surfaces including necessary form work and including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, complete all as specified and as directed by Engineer-in- charge. (Note :- WPC shall be measured & paid separately as Supply only)
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for 75mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed by Engineer-in-charge.
Supply only water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for mild steel work tubular poles/post including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to latest relevant IS grade St-240 complete all as specified & directed by Engineer-in- charge.
Supply and fixing Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Material and labour for preparing newly plastered or concrete surface of wall by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying three coats of cement base paint as per approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Supply only ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Supply only gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Material & Labour for machine pressed precast interlocking paver block with grey cement and no pigment, factory made, any shape and size, conforming to IS 15658-2006 of 80 mm thickness, made out of M-40 grade concrete laid over and including 30 mm thick layer of sand complete all as specified and as directed by Engineer-in-charge.
Material & Labour Factory Made Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in kerb stone, quion block, apex stone etc set in cm 1:4 incl formwork weathering slightly rounded or chamfered angles and throating complete all as specified and as directed by Engineer-in-charge.
Material & Labour for 75 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for PCC (1:3:6) type C2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour cutting into existing manholes/septic tank for connecting new drain upto 150mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round to 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished, and reforming benching as required complete all as specified & directed by Engineer-in-charge.
Material and labour for cement concrete (1:4:8), type D2 using 40mm graded stone aggregate as in bed of drain pipe of size upto 150mm bore (internal) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in- charge.
Material and labour for 150mm bore (internal dia) salt glazed stone ware (SGSW) drain pipe, grade ‘A’, laid on concrete bed to required slope in trenches, jointing with packed spun yarn and in cement and sand mortar (1:1) and tested complete all as specified and directed by Engineer-in-Charge. (Note : Excavation, earrh work and concrete bed shall be measured and paid separately under appropriate item of BOQ.)
Supply & fixing vitreous China squatting pan 'Orissa' pattern white of size 580mmx440mm white with integral foot rests, excluding flushing cistern, flush pipe above floor but including PVC (SWR) 'P' trap 100/110mm bore and including setting the trap and pan in lime concrete (1 lime, 2 sand or surkhi and 5 aggretate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing, including PVC flush pipe upto finished floor level, joints of flush pipe and trap make leakproof and testing upto entire satisfaction of Engineer-in-charge before filling concrete complete all as specified and as directed by Engineer-in- charge.
Supply and fixing 10 litres capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handle including brackets and 32mm dia PVC flush pipe complete all as specified and directed by Engineer-in-Charge.
Supply & fixing vitreous china wash basin, white, oval type 550mm x 400mm, including 32mm chromium plated waste coupling and PVC waste pipe including bracket and cutting for and pinning in end of bracket or erecting including fixing only pillar tap (new or serviceable old pillar tap as per site condition ) complete all as specified and as directed by Engineer-in-Charge. (Note :- Pillar tap if required in replacement, shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply and fixing bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing stop valve/angle valve cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply & fixing 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 500 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and fixing ball valve and gate valve complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply & fixing Mild steel work of Fe-290 Gde E -165 as in angle iron fencing posts & flat iron drilled and countersunk for boulders running bars,including embedding in concrete and scruing etc,post and struts in fencing including cutting, tops to shape as directed, bent to shape, drilling holes, notching for wire etc,flat iron fillets (for securing wire mesh etc.) Including all necessary drilling,bolting or riveting etc.complete all as specified and shown on drawings. Note:- The element of Fixing of round bars for chain link fencing is included in this item .Nothing shall extra be paid on this account .
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire. (Line wire shall be measured and paid for separately as supply only rate).
Supply only mild steel galvanised chain link fencing of mesh size 100mm x 100 mm and dia of wire 4 mm etc. including provision of binding wire complete all as specified and as directed by Engineer-in-charge. .Note :- Weight of chain link fencing shall be physically ascertained through a board of officers convened by Accepting officer and payment shall be made only after the actual weight at site.
Supply & fixing galvanised steel , 2 strand barbed wire 2.24mm dia , barbed with 2mm dia barbs at 65mm to 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (each line of wire to be measured), complete all as specified and as directed by Engineer-in-charge.
Supply & fixing Mild steel screw bolts (machine made) with5 to 10 mm dia of neck and 40 mm long, hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolts n.exc 5 cm long complete all as specified and as directed by Engineer-in-charge.
Supply only 10mm dia MS round bar for fixing of chain link fencing with post complete all as specified and directed. Note :-Fixing element of this item is included in serial item no. 138 here-in-before.
Taking down carefully existing unserviceable copper / aluminum point wiring (light, fan, socket) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, light fittings etc except concealed conduit and sunken boxes and removing the retrieved materials from site complete all as specified and as directed by Engineer-in- charge
Material and Labour for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with 1.5 Sqmm nominal cross sectional area single core PVC insulated, unsheathed 'multi stranded' FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) 20mm bore surface on wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) including modular metal flush box concealied with front & modular cover plate with frame suitable matching colour of required module for mounting or housing switches, socket outlets, fan regulators, etc. including blanking plates & all other fixing accessories for one light/fan/call bell/exhaust fan point controlled by one 5/6 Amps switch and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in-charge. NOTE:- The quoted unit rate is deemed to be inclusive of cost of metal flush boxes, modular white cover plates, modular frame plates and flush fixed with cement mortar 1:4 etc.However modular switches,sockets and regulators shall be measured and paid seperately under respective items of Schedule'A' BoQ.
All as per serial item No 144 here in before but for one socket outlet 5 pin 5/6 Amps 250 volts flush type on same board complete all as specified and as directed by Engineer-in-charge.
All as per serial item No 144 here in before but for one socket outlet 5 pin 5/6 Amps 250 volts flush type on Independent board complete all as specified and as directed by Engineer-in-charge.
All as per serial item No 144 here in before but for one bell point controlled by one bell Push on independent board complete all as specified and as directed by Engineer-in-charge.
All as per serial item No 144 here in before but for one socket outlet 6 pin, 6/16 Amps 2 in 1 with cable 2.5 Sqmm multistranded copper conductor FRLSH cable on the independent board but not below the switch board including provision of 2.5 Sqmm PVC insulated copper conductor FRLSH cable continuos as earth wire connected to earth dolly, conductor etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Modular Switch 1 way 6A,1 Module complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Modular Bell push 6A 1 module complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Modular Switch one way 16 Amp 240 Volt, AC ,1 Module complete all as specified and directed by Engineer-in-charge.
Supply and fixing Modular Socket Outlet , Multipurpose,3 Pin, 6 Amp , 2 Module complete all as specified and directed by Engineer-in-charge.
Supply and fixing Modular Socket outlet , multipurpose, 2/3 Pin, 6/ 16 Amp 2 Module complete all as specified and directed by Engineer-in-charge.
Supply and Fixing ceiling rose surface type polycarbonate, isolated body three terinal,, tpline series 20 x 50mm, 6 Amps, three terminal complete all as specified and as directed by Engineer-in-charge.
Supply & fixing Electric / Electronic Bell, ding dong type 230 Volt AC supply complete all as specified and as directed by Engineer-in-charge.
Supply and fixing modular stepped type electronic fan regulators flush socket type complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing Lamp holder PVC/polycarbonate type with back plate suitable for batten fitting with LED bulb 9W complete all as specified and as directed by Engineer-in-charge.
Supply & fixing wall mounted LED fitting 1 x 20 watt,6000k, 4 ft complete with squire profile batten, environment friendly , energy efficient complete with all fittings connections complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing light fitting of 9/10 watt, 6000 K , lineer & compact with decorative grey end caps,polycarbonate body and ribbed opal diffuser complete with lamp and all other accessories fitting arrangement including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector complete all as specified and as directed by Engineer-in-charge.
Supply and fixing recessed LED ceiling lite with wide light window for maximized glare warm white/cool white free output suitable for 600x600mm and ceiling cutout 595x595mm modular grid/POP ceiling complete fitting with separate electronic driver and high brightness SMD LEDs 36 watt, 6000K and one nos extra LED driver along the fittings including connecting electric connection, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing building security light die cast ast aluminium IP 66 roadway luminaire with high power LED of 35 watt with toughened glass complete with suitable GI for security light fitting fixing to wall/column & electrical connection to the light fitting providing 1.5 mtr long twin core round copper conductor cable of suitable size and testing complete all as specified and as directed by Engineer-in-charge.
Material and Labour for Sub main wiring concealed PVC conduit with two single core of size 6 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade drawn in and including non metallic rigid PVC conduit medium quality of size 25 mm dia conforming to 3537 Part-I ISI marked including one single core of size 6 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade as in contineous earth conductor cable connected to earth dolly complete all as specified and as directed by Engineer-in-charge.. (Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified & directed.Notes:-(a) Cost of PVC conduit , conduit accessories and earth wire included in sub main wiring. (b) Three single core 6 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade including non metallic rigid PVC conduit of size 25 mm dia shall be measured as one length.
Material and Labour for Sub main wiring concealed PVC conduit with two single core of size 4 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade drawn in and including non metallic rigid PVC conduit medium quality of size 25 mm dia conforming to 3537 Part-I ISI marked including one single core of size 4 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade as in contineous earth conductor cable connected to earth dolly complete all as directed. (Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and as directed by Engineer-in-charge..Notes:-(a) Cost of PVC conduit , conduit accessories and earth wire included in sub main wiring. (b) Three single core 4 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade including non metallic rigid PVC conduit of size 25 mm dia shall be measured as one length.
Supply and Fixing Sheet metal enclousers made out of CRCA mild steel sheet, IP-43 protection, flush mounted for metal door, powder coated DB V TPN 4 way, 415 V AC with 200 Amps rated bus bar, Double door, dust and vermin proof suitable for incorporation of Incoming MCCB and outgoing MCB SP/TP and earth & neutral bus bar etc incl taking down old unserviceable DB complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing Sheet metal enclousers made out of CRCA mild steel sheet, double door, powder coated DB SPN 8 way 240 Volt, 200 Amps rated bus bar, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete including taking down old unserviceable DB complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing in replacement of MCCB 4 pole of rating 100 Amp, Icu -100% 16 KA, thermal magnetic based complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing in replacement of MCB SPN 63 Amps, 10 KA, B Curve, 230 V AC,50 Hz including necessary attachment complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing in replacement of MCB SP 6 to 40 Amps 240, 10 KA B/C curve complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing in replacement of Exhaust fan 300mm sweep, BEE, 5 star rated and electrical connection providing with twin core round copper conductor cable of suitable size including taking down old unserviceable exhaust fan and deposited to E/M store all as specified and directed by Engr-in- Charge.
Supply and hanging /fixing ceiling fan 1400 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, Min air delivery 240 CFM with service value 6.00 BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, minimum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified and taking down old ceiling fan and deposited to E/M store. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account and taking down old ceiling fan and deposited to E/M store all as specified and directed by Engineer-in-Charge
Material and Labour in replacement of corroded GI Pipe of size 40mm for hanging of Ceiling fan of above approx miniumum length 5 Mtr each suitable for bearing capacity of hanging of a ceiling fan including arrangements of ceiling fan hooks and making holes on existing wall for fixing of pipe and its cement finishing work all as specified and directed by Enge-in- Charge
Supply and Fixing in replacement water heater (Geyser) Auto restrat and safety measures type electrical operated 230/240 Volts 25 ltr capacity, BEE 5 star rated complete with all safety equipment and accessories such as safety valve, thermostat, plug top, etc. required for proper functionality & including electric/earth connections and carrying out grounting & complete installations with mounting bolts,nuts including testing after installation complete including taking down old out dated Geysers to be deposited E/M store yard all as specified & directed by Engr-in- Charge.
Supply and Fixing in replacement sheet metal enclosure with two pin & earth plug and socket (industrial type DB) with and including one MCB SPN ,B curve type capacity 25 Amps ,10 KA complete all as specified and as directed by Engineer-in-charge..
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, 2mm thick galvanised steel pressed sunken terminal boxes of suitable size (Min 60mm deep, suitable length) concealed in wall, 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed by Engineer-in-charge.. (switches, regulator shall be measured and paid separately under appropriate item of BOQ).
All as per serial item No 174 here in before but for one socket outlet 5 pin 5/6 Amps 250 volts on same board complete all as specified and as directed by Engineer-in-charge.
All as per serial item No 174 here in before but for one socket outlet 5 pin 5/6 Amps 250 voltse on Independent board complete all as specified and as directed by Engineer-in-charge.
All as per serial item No 174 here in before but for socket outlet one 6 pin, 6/16 Amps, 2 in 1 with cable 2.5 Sqmm multistranded copper conductor FRLSH cable on the independent board including provision of 2.5 Sqmm PVC insulated copper conductor FRLSH cable continuos as earth wire connected to earth dolly, conductor etc complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing switch piano flush type, single pole, one way, 5/6 Amps ISI mark complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing iswitch piano flush type , single pole, one way, 15/16 Amps ISI mark complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing socket outlet multipurpose, 2 in 1, 5 pin, 5/6 Amps, flush type complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing socket outlet multipurpose , 2 in 1, 5 pin, 15/16 Amps, flush type complete all as specified and as directed by Engineer-in-charge.
Supply & fixing wall mounted LED fitting 1 x 20 watt,6000k, 4 ft complete with squire profile batten, environment friendly , energy efficient complete with all fittings connections complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing LED mirror light fitting 10 watt, 6000 K 2 feet, linear & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete fitting with lamp and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector complete all as specified and as directed by Engineer-in-charge..
Supply and Fixing building security light die cast ast aluminium IP 66 roadway luminaire with high power LED of 35 watt with toughened glass complete with suitable GI for security light fitting fixing to wall/column & electrical connection to the light fitting providing 1.5 mtr long twin core round copper conductor cable of suitable size and testing complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing Sheet metal enclousers made out of CRCA mild steel sheet, double door, powder coated DB SPN 8 way 240 Volt, 200 Amps rated bus bar, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing MCB SPN 63 Amps, 10 KA, B Curve, 230 V AC,50 Hz including necessary attachment complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing MCB SP 6 to 40 Amps 240, 10 KA B/C curve complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing Exhaust fan 300mm sweep, BEE, 5 star rated and electrical connection providing twin core round copper conductor cable of suitable size including making suitable size hole on the wall and its fininishing work all as specified and directed by Engr-in- Charge.
Taking out old unservicable under ground LT XLPE of 35 Sqmm 3.50 from trenches / wall / roof / road / pipe / pole / DB including taking out of brick layer of cable protection complete all as directed.
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 35 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 35 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note :- For measurement purpose puned thickness shall be measured and paid i.e 18cm.)
Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Material and labour in replacement of Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I), including taking down old earthing, complete all as specified and and as directed by Engineer-in-charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I), including taking down old earthing, complete all as specified and and as directed by Engineer-in-charge.
Material and labour for 75mm thick PCC (1:3:6) Type C-2 using 40mm graded stone aggregates as in plinth protection, funishing the surface even and fair complete all as specified and directed by Engr-in-Charge.
Supply & Fixing vitreous china urinal half stall type white with grating in and union for discharge pipe incl providing and fixing plug bedding urinal against wall in Cement Mortar 1:2 securing urinal to plugs with and incl 60mm long brass screws, pointing around urinal back in cement all as specified and directed by Engr-in-Charge.
Supply & Fixing 15mm bore pillar taps, Fancy type, cast copper alloy with capstan heads, Decorative type chromium plated screwed down, high pressure screwed for iron pipe complete all as specified and directed by Engr-in-Charge.
Material and Labour for Preparation of new steel surfaces of any description not exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed by Engr-in-Charge.
Material and Labour for complete removal of existing treatment and applying two coats of plastic emulsion paint (interior emulsion) of approved tint/ colour complete all as specified and directed by Engr-in-Charge.
Dismantling cast iron pipes upto 100mm dia/bore and any description including all fittings complete all as specified and directed by Engr-in-Charge.
Supply & Fixing Anodised aluminium window and ventilator shutters/ glass partition (Powder coating of any colour, thickness of powder coating not less than 50 micron), fixed type without sash bars, aluminium sections weighing 1.10 kg/m including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, etc. complete all as specified and directed by Engr-in-Charge.
Material and Labour 100mm thick PCC 1:4:8 Type D-2 using 40mm graded stone aggregates as in sub base of floor complete all as specified and directed by Engr-in-Charge.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ.
M/S BHAGWATI CONSTRUCTION COMPANY
ANNPOORNA ENGINEERS & BUILDERS
SHARDA ENTERPRIES
M/s MITTAL CONSTRUCTIONS
Ajay Enterprises
M/s Verma Construction Company
M/S VERMA BUILDERS & DEVELOPERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .