Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance AURI MOR ANPARA SONEBHADRA ANPARA SONBHADRA UTTAR PRADESH 231225 | SONBHADRA | UTTAR PRADESH | 231225 | Admitted-Finance |
Tender Value
₹5.9 L
EMD Value
₹4,000
Closing Date
18 May 2020, 4:00 pmClosed
Superintending Engineer O and MC II BTPS Anpara
Office of Superintending Engineer O and MC II BTPS Anpara
Servicing Revisioning of high pressure valves and safety valves of critical piping and other associated works of boiler of unit no. 4 and 5 2x 500 MW BTPS Anpara
2020_RVUNL_458303_1
T-01/BMD-I/BTPS/2020-2021
Open Tender
Miscellaneous Works
Fixed-rate
Anpara Thermal Power Plant Anpara
As per PQC of the tender
3 documents required · 3 mandatory
₹590
Dy CAO CFA and BO BTPS Anpara
₹4,000
20 Jun 2020
13 Apr 2020
22 May 2020
14 Apr 2020
18 May 2020
14 Apr 2020
13 Apr 2020 - 17 May 2020
Amount
Servicing/Revisioning of boiler circulation pump inlet gate valve (manually operated), Nb-500 mm Np- 210 Kg/Cm² .
Servicing/Revisioning of electrically operated boiler circulation pump discharge valve. Type- Elbow down stop valve. Nb-500 mm Np- 210 Kg/Cm² .
Servicing/Revisioning of manually main steam stop valve. Nb-425 mm, Np- 189.5 Kg/Cm².
Servicing/Revisioning of Economizer inlet isolating gate valve. Nb-500 mm, Np- 302 Kg/Cm².
Servicing/Revisioning of Economizer swing check valve. Nb-500 mm, Np- 302 Kg/Cm².
Servicing/Revisioning of Economizer isolating gate valve & check valve of boiler fill pump line. Nb-200 mm, Np- 221 Kg/Cm².
Servicing/Revisioning of hand operated isolating gate valve & check valve of Primary & Secondary super heater atttemparation line & isolating gate valve of Aux. steam line and other similar valves. Nb-150 mm, Np- 224 Kg/Cm².
Servicing/Revisioning of electrically operated isolating gate valve of Primary & Secondary super heater atttemparation line & Aux. steam inlet gate valves and other similar valves. Nb-150 mm, Np- 224 Kg/Cm².
Servicing/Revisioning of Motor operated Control valves of Primary & Secondary super heater atttemparation line & other similar valves. Nb-150 mm, Np- 224 Kg/Cm²
Servicing/Revisioning of Motor operated Control valves of Re-heater atttemparation line & other similar valves. Nb-100 mm, Np- 152 Kg/Cm².
Servicing/Revisioning of Hand operated isolating gate valve of Re-heater atttemparation line & other similar valves. Nb-100 mm, Np- 152 Kg/Cm².
Servicing/Revisioning of Motor operated isolating gate valve of Re-heater atttempration line & other similar valves. Nb-100 mm, Np- 152 Kg/Cm².
Servicing/Revisioning of Hand operated gate valve of Aux. steam header inlet line & other similar valves. Nb-400 mm, Np- 205 Kg/Cm².
Servicing/Revisioning of outlet check valve of Aux. steam line & other similar valves. Nb-400 mm, Np- 205 Kg/Cm².
Servicing/Revisioning of Hand operated High pressure valves and NRVs. Nb-15 to 100 mm.
Servicing/Revisioning of Motor operated High pressure valves. Nb-25 to 100 mm.
Servicing/Revisioning of Motor operated High pressure valves. Nb-150 to 250 mm.
Servicing/Revisioning of Hand operated High pressure valves. Nb-150 to 250 mm.
Servicing/Revisioning of Check valves Re-heater isolating device. Nb-700mm/ 900mm.
Servicing/Revisioning of Motor operated High pressure valves. Nb-250 to 350 mm.
Servicing/Revisioning of Hand operated High pressure valves. Nb-250 to 350 mm.
Servicing/Revisioning of Boiler Drum safety valves. Nb-75mm, Np-205 to 212 Kg/Cm².
Servicing/Revisioning of Super heater outlet safety valves. Nb-75mm, Np-187.5 Kg/Cm².
Servicing/Revisioning of Electromagnetic relief valves. Nb-50mm, Np-184 Kg/Cm². Temp.-548ºC.
Servicing/Revisioning of hot Re-heat & Cold Re-heat safety valves.
Servicing/Revisioning of continuous blow down tank safety valve. Nb-150mm, Np-16Kg/Cm².
Servicing/Revisioning of Auxiliary PRDS line safety valves. Nb-65mm, Np-20Kg/Cm².
Servicing/Revisioning of Soot blowing line safety valve. Nb-150/200mm, Np-25Kg/Cm².
Servicing/Revisioning of pneumatic operated control valve/block valves. Nb-50 to 100mm.
Servicing/Revisioning of pneumatic operated piston valves of primary & secondary super heater attemperation line. Nb-200mm, Np- 205 Kg/Cm².
Servicing/Revisioning of hand operated valves and NRVs of oil control station at firing floor. Nb-25 to 150mm.
Replacement of gaskets of flanges and bonnets of valves.
Replacement of gland packing of high pressure valves.
Attending leakage of pipelines and headers etc. of main boiler.
Cleaning of oil strainer of fuel oil station on firing floor.
Servicing of gear box of hand operated air motor driven valves of main steam line, BCP, ERV etc.
Replacement of safety valve seat of critical piping such as boiler drum, main steam line, Re-heater line etc.
Replacement of high pressure valve (motor operated/hand operated) of critical piping of boiler of size 15 - 25 mm.
Replacement of high pressure valve (motor operated/hand operated) of critical piping of boiler of size 40 - 50 mm.
Replacement of high pressure valve (motor operated/hand operated) of critical piping such as Main steam, Final super heater, Primary super heater, CBD etc. of size 65 - 150 mm.
M/s Varghese Contractor
SHAKSHI ENGINEERING CO.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .