Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
24 Oct 2024, 4:00 pmClosed
Executive Engineer, ED DODA
ED DODA
Erection of HT line for 63 KV substation at jai valley under the jurisdiction of JPDCL ED Doda under PRI Grant ON FULL TURNKEY BASIS
2024_PDD_259088_1
ED Doda/JPDCL/22 of 2024-25
Open Tender
Electrical Works
Turn-key
90 days
ED DODA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer, ED DODA
₹44,000
25 Oct 2024
10 Oct 2024
25 Oct 2024
10 Oct 2024
24 Oct 2024
11 Oct 2024
Amount
Erection of HT line for 63 KV substation at jai valley Part I ( All items are SITC)
9 Mtr. Long ST Pole (ST-410 SP15)
GI Channel X-arm 5 FEET Long 75x45x6mm including clamps and angle braces 60x40x6 mm braces
30 mm² ACSR Conductor weasal
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turnbuckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
11kV Link Set Heavy Duty with Bace Channel 75x40x40x6 mm
Anti-Climbing Device with Clamps
Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Strip.
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Nuts and Bolts
Aluminium Paint
Erection of HT line for 63 KV substation at jai valley Part II ( All items are SITC)
9 Mtr. Long ST Pole (ST-410 SP15)
GI Channel X-arm 5 FEET Long 75x45x6mm including clamps and angle braces 60x40x6 mm braces
30 mm² ACSR Conductor weasal
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turnbuckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
11kV Link Set Heavy Duty with Bace Channel 75x40x40x6 mm
Anti-Climbing Device with Clamps
Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Strip.
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Nuts and Bolts
Aluminium Paint
Erection of HT line for 63 KV substation at jai valley Part III ( All items are SITC)
9 Mtr. Long ST Pole (ST-410 SP15)
GI Channel X-arm 5 FEET Long 75x45x6mm including clamps and angle braces 60x40x6 mm braces
30 mm² ACSR Conductor weasal
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turnbuckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
11kV Link Set Heavy Duty with Bace Channel 75x40x40x6 mm
Anti-Climbing Device with Clamps
Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Strip.
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Nuts and Bolts
Aluminium Paint
Erection of HT line for 63 KV substation at jai valley Part IV ( All items are SITC)
9 Mtr. Long ST Pole (ST-410 SP15)
GI Channel X-arm 5 FEET Long 75x45x6mm including clamps and angle braces 60x40x6 mm braces
30 mm² ACSR Conductor weasal
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turnbuckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
11kV Link Set Heavy Duty with Bace Channel 75x40x40x6 mm
Anti-Climbing Device with Clamps
Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Strip.
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Nuts and Bolts
Aluminium Paint
Erection of HT line for 63 KV substation at jai valley Part V ( All items are SITC)
9 Mtr. Long ST Pole (ST-410 SP15)
GI Channel X-arm 5 FEET Long 75x45x6mm including clamps and angle braces 60x40x6 mm braces
30 mm² ACSR Conductor weasal
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turnbuckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
11kV Link Set Heavy Duty with Bace Channel 75x40x40x6 mm
Anti-Climbing Device with Clamps
Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Strip.
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Nuts and Bolts
Aluminium Paint
MALIK ELECTRICAL CONSTRUCTION AND SUPPLIERS
Daya Krishan Raina
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .