| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.6 LAccepted-Finance | 1 | Accepted-Finance Accept | |
| 2 | 2₹23.8 L+₹7.3 L (43.8%)Accepted-Finance | 2 | Accepted-Finance Accept | |
| 3 | 3₹26.4 L+₹9.9 L (59.4%)Accepted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | 3 | Accepted-Finance Accept | |
| 4 | Not Admitted-Fee/PreQual/Technical 01 KATYANI CONSTRUCTION COMPANY H NO 1 SHOP NO 1 RATAN LAL NAGAR KANPUR NAGAR UTTAR PRADESH 208022 | KANPUR NAGAR | UTTAR PRADESH | 208022 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
5 Dec 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE ETD FATEHGARH
ETD FATEHGARH, 132 KV S/S BEWAR ROAD FATEHGARH FARRUKHABAD-209602
WORK
2022_UPTCL_750583_1
T-25/ETD(F)/2022-23
Open Tender
Electrical Works
Fixed-rate
90 days
FATEHGARH
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,832
UPPTCL ETD FATEHGARH
₹48,000
3 Feb 2023
19 Nov 2022
5 Dec 2022
19 Nov 2022
5 Dec 2022
19 Nov 2022
Amount
ERECTION OF FOLLOWING AT 132 KV SUB-STATION FATEHGARH FOR CONSTRUCTION OF 132 KV BUS COUPLER BAY,132 KV AND 33 KV BAY FOR ADDITIONAL 40 MVA, 132/33 KV TRANSFORMER 3rd AGAINST INCREASING CAPACITY OF SUB-STATION ,MODIFICATION OF EXISTING BUS COUPLER BAY TO LINE BAY AND SHFTING OF 132 KV CHIBBRAMAU LINE BAY
Erection of Main & Auxiliary Sub-Station Structure
Proper stacking and shifting of Main & auxiliary structure in open switchyard at erecting place as per shop bill norms.
Erection of Main & Auxiliary structure lattice type ATM,AXM,XPM,YMM,BBL,BCT,ALP,ABL etc. consisting of column, beam, peak, mast etc. and auxiliary structure for installation of isolator, CTs, PTs, LA etc. erection of structure as per drawing with the help of GI nuts & Bolts flat spring washer matching the hole, cutting and matching the member if required include cost of all men and T & P excluding GI structure nut and bolts to complete the work erection of main & auxiliary structure lattice type upon foundation and its proper tightening.
Making hole in part of GI Main/auxiliary structure / cutting of GI angle drilling of hole existing/ defective structure /plate/Angle and grinding machine with all cost of men, T & P etc.
Erection of following equipment as per instruction manual of various equipment’s and technical specification including shifting of material / equipment from store to erection site including all other associated works to complete the job satisfactorily.
Erection of 145 KV SF6 Circuit Breaker
Erection of 36 KV Vacuum Circuit Breaker
Erection of 145 KV Current Transformer/Potential Transformer
Erection of 36 KV Current Transformer/PT
Erection and mounting of 145/36 KV CT/PT junction box.
Erection of 145 KV bus Isolator without earth switch
Erection of 36 KV Bus Isolator.
Erection of 120 KV Lighting Arrestors
Erection of 30 KV Lighting Arrestors
Erection of following control and relay Panels as per instruction manual and technical specification including shifting of panel from store to erection site including all other associated works to complete the job satisfactorily.
Erection of 132 KV control relay panel for 40 MVA Transformer.
Erection of 40 MVA RTCC Panel.
Stringing of 132 KV Main/Transfer/Jack bus of ACSR Moose/Zebra/ panther conductor of various sizes length span as mentioned below .the work includes cutting &bending of conductor fixing of single /double bolted type tension fitting /suspension hoisting of disc Insulator and shifting of material from store .site to erection site and all other associated work to complete work satisfactorily as per drawing and technical specification.
132 KV Main Bus extension approx 12 mtrs of Moose conductor including interconnection with existing bus
132 KV Transfer Bus extension approx 12 mtrs of Zebra conductor including interconnection with existing bus
132 KV Jack Bus approx 36 Mtrs of ACSRpanther conductor
Bay wise interconnection of equipment with specified conductor of various 132 KV & 33 KV Equipment with Main /Transfer / jack Bus bar of ACSR Zebra /Panther conductor. The work Includes cutting of conductor. Bending in proper shape .clamping with the help of clamp and all other associated work to complete job.
132 KV Bus coupler bay
Modification of existing bus coupler bay to line bay
132/33 KV,40 MVA Transformer Bay 132 KV side Bus
33 KV side Transformer bay Twin Moose
Laying and Termination of following size control cable in trench/cable trays from different control room equipment to 132/33 KV Isolator, circuit breakers CT/PT & their junction boxes. Transformer marshaling box. Isolator box & other outdoor equipment’s installed in 132/33 KV switch yard as per cable schedule. Including carriage of cable drum from store and all other associated work.
Control cable of size 2 core x 2.5 mm2
Control cable of size 4 core x 2.5 mm2
Control cable of size 6 core x 2.5 mm2
Control cable of size 10 core x 2.5 mm2
Termination of control cable
Installation work of 40 MVA Transformer
Shifting of main tank of 40 MVA Transformer from unloading point to the plinth up to 40 Mtr. distance including turning of tank if required including all T&P and labor required to complete the job satisfactorily.
Complete erection of 40 MVA 132/33 KV Transformer by erection of radiator, conservator and all bushing oil pipe lines, cooling fans etc. to complete the job satisfactorily.
Circulation of complete Transformer oil in Transformer tank through centrifuging machine, centrifuging machine shall be provided by the contractor ,oil capacity (Approx20 KL )
Fabrication of 3 meter long electrode with 40 mm dia. M S round bar having 150 mm long conical shape by digging cutting, straightening etc. and then placing it vertical. inside the ground with Top 700mm below the ground level including shifting of MS round bar from storage place at the Sub-Station to switchyard.
Delta earthing of 120KV /33 KV LA's and132/33 KV 40 MVA Transformers neutral by consisting of 6/4/3Nos. 3.0 Mtr long electrode of 40mm dia. having 150mm long conical shape, its placing inside the ground in rectangular/triangular shape and connection all 6/4/3 Nos. electrodes with 75x10/50x6mm MS flat laid on its edge and then this rectangle/triangle shape be connected to main earth mat at two place in opposite direction strictly as per drawing.
120 KV Lighting Arrestors (Rectangle shape 6 electrode )
30 KV Lighting Arrestors (Rectangle shape 4 electrode )
132/33 KV 40 MVA Transformer (Triangular shape 3 electrode)
Shifting of 132 KV Chibbramau line conductor from dead tower to its existing line bay gentry to newly modified line bay gentry at 132 KV S/S Fatehgarh the work includes dismantling all phase conductor with insulator strings n fitting from dead end tower to its gentry by opening its all jumpers and taking its conductor down after releasing its tension from both ends .Restringing of fresh ACSR panther with disc insulator string and fittings of suitable seize after compressing tension fitting from dead end tower to newly modified bay gentry and its jumpering with jumper cone.
Earthing of equipment’s by cutting straightening, bending, laying 700mm below ground and above ground of following size of MS flat for earthing of main and auxiliary structure, equipment’s structure. Transformer body and its neutral point including welding with main earthmat and with object to be earthed excavation of trenches its back filling. All other associated work as required to complete the work. MS Flat shall be provided by the contractor
Laying of MS Flat of size 75x10 mm
Laying of MS Flat of size 50x6 mm
Laying of MS Flat of size 25x6 mm
Painting of MS flat of different size after cleaning of rusted surface 1st coat of Red Oxide and 2 coat of Bus Green Paint to complete the work.
MS Flat of size 75x10 mm
MS Flat of size 50x6 mm
MS Flat of size 25x6 mm
Shifting of High mast light from existing position lying in proposed position of 132 KV bay for 40 MVA 3rd T/F bay to outside from it work includes dismantling of high mast assembly including its pole safely. Recasting its foundation as per drawing of suitable strength with anchor bolt at different place. Re installation of it with electrical wiring as per drawing.
STRENTHENING OF 33 KV MAIN BUS FROM SINGLE TARANTULLA/ZEBRA TO TWIN MOOSE CONDUCTOR WORK SHALL BE CARRIED OUT AS DETAILED HERE UNDER
Dismantling of 33 KV Old/ Damaged Main bus bar Sections (R, Y, & B) of Single Tarantulla/Zebra conductor and lowering down of conductor from sub-station gantry to complete dismantling work including dismantling of all associated Tension clamps, fittings & Disc insulators etc.
Dismantling of single Moose /Panther conductor Jumpers of T/Fs LV side/33 KV feeders bay from main bus to BSI to switchgear to CT to LSI.
Dismantling Jumpering of 33 KV PT/LA, jumper from Section Isolator 33 KV Main bus, Moose/Zebra conductor.
Stringing and proper sagging of new 33 KV Main bus bar Sections (R, Y & B) by Twin Moose conductor the work includes fitting of tension clamps, Hoisting of 70 KN Disc, tension fittings, Spacers PG Clamps etc. and cutting of conductor as required.
Jumpering of 63 MVA T/Fs LV side bays and 33 KV feeders bays from main bus to BSI to C.T. to C.B.to LSI., byTwin Moose/Panther conductor.
Jumpering of 33 KV Equipment, jumper from Section Isolator of Twin Moose Conductor.
Supply
Supply of following material for construction of 132 KV Bus coupler bay, 132/33 KV Bay for additional 40 MVA t/F 3rd bay, Modification of existing bus coupler bay to line bay and strengthening of 33 KV main bus from single Tarantullah/Zebra conductor to twin Moose :-
PG Clamp Moose to Moose
PG Clamp Moose to Panther
PG Clamp Panther to Panther
Spacer for 250mm spacing for Twin Moose Conductor 02 bolted complete with hot dip galvanized nut, bolts & washer as per technical specification.
Spacer for 100mm spacing for Twin Moose Conductor 02 bolted complete with hot dip galvanized nut, bolts & washer as per technical specification.
33 KV Circuit Breaker clamp suitable for Twin Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
33 KV Isolator clamp suitable for Twin Moose conductor one side connecting the Twin Moose conductor and another side a plate with 04 Nos. 12mm dia. hole as per technical specification with HDG nut & Bolt.
33 KV CT clamp suitable for Twin Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification with HDG nut & Bolt.
Bolted type single gun, Tension fitting for Panther Conductor suitable for 1x10 No Disc insulators complete with hardware set as per technical specification.
Bolted type single gun, Tension fitting for Moose Conductor suitable for 1x10 No Disc insulators complete with hardware set as per technical specification.
Bolted type single gun, Tension fitting for Zebra Conductor suitable for 1x10 No Disc insulators complete with hardware set as per technical specification.
Supply of 33 KV bolted type tension fitting for Twin Moose conductor 1x4 No. disc insulator with turn buckle complete with hardware fitting d-sackle, d-socket, ball hook, yoke plate, d-clip it tension clamp etc. as per technical specification.
Supply of 33 KV bolted type tension fitting for Twin Moose conductor 1x4 No. disc insulator without turn buckle complete with hardware fitting d-sackle, d-socket, ball hook, yoke plate, d-clip it tension clamp etc. as per technical specification.
33 KV Isolator clamp suitable for Twin Panther conductor one side connecting the Panther conductor and another side a plate with 04 Nos. 12mm dia. hole as per technical specification with HDG nut & Bolt.
33 KV Section Isolator clamp suitable for Twin Moose conductor one side connecting the Moose conductor and another side a plate with 04 Nos. 12mm dia. hole as per technical specification with HDG nut & Bolt.
Spacer for 60mm spacing suitable for Twin Panther conductor 01 bolted made of aluminum alloy LM-06 complete with hot dip galvanized nut bolt and washer as per technical specification.
M/s S.S. Refregeration
P&H Engineering
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .