| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-01₹9.2 LAccepted-AOC NEAR PAYAL CINEMA P O SEVOKE ROAD SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L-01 | Accepted-AOC Being lowest bidder | |
| 2 | L-02₹9.4 L+₹15,485 (1.68%)Rejected-Finance A 4 VIVEKANANDA SUPER MARKET 2ND FLOOR HILL CART ROAD SILIGURI 734 001 DIST DARJEELING W B | JALPAIGURI | WEST BENGAL | 734001 | L-02 | Rejected-Finance Being second lowest bidder | |
| 3 | L-03₹9.4 L+₹22,671 (2.46%)Rejected-Finance OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L-03 | Rejected-Finance Being third lowest bidder | |
| 4 | L-04₹9.5 L+₹25,965 (2.82%)Rejected-Finance | L-04 | Rejected-Finance Being fourth lowest bidder | |
| 5 | L-05₹9.5 L+₹30,146 (3.27%)Rejected-Finance | L-05 | Rejected-Finance Being fifth lowest bidder |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
1 Dec 2020, 6:00 pmClosed
AGE I DARJEELING
PO- JALAPAHAR, DIST- DARJEELING, PIN- 734103 (WB)
COMPREHENSIVE MAINT REPAIR OF DG SETS VOLTAGE STABILIZERS APFC PANELS AND LT PANELS AT JALAPAHAR AND LEBONG UNDER AGE I DARJEELING
2020_MES_383474_2
8754/E8
Open Tender
Civil Works
Item Rate
182 days
JALAPAHAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
AGE (I) DARJEELING
₹18,000
Yes
26 Dec 2020
12 Nov 2020
3 Dec 2020
12 Nov 2020
1 Dec 2020
23 Nov 2020
12 Nov 2020 - 17 Nov 2020
Amount
M&L for Inspection & maintenance of serviceable DG Sets as per manufactures instruction and as given below (after running of 250 to 300 hrs ) for 62.5 KVA DG set complete all as specified and as directed. NOTES :-I ) ‘B’ Check maintenance shall include :- a)Changing of oil b)Changing oil filter,fuel filter,bypass filter& gasket c ) Changing Air filter d) Removing water from water separator e)Changing gas cut for piston head ii)Supply only spares components engine oil etc ,for carrying out ‘B’ check maintenance shall be measured and paid separately.
All as per item No 01 here-in-before but 82.5KVA complete all as specified and as directed.
All as per item No 01 here-in-before but 100KVA complete all as specified and as directed.
All as per item No 1.00 here-in-before but 125KVA complete all as specified and as directed.
All as per item No 01 here-in-before but 160KVA complete all as specified and as directed.
Supply only Engine Oil complete all as specified and as directed.
Supply only Coolant complete all as specified and as directed.
Supply only Distil water complete all as specified and as directed.
Supply only Lub oil filter for 62.5KVA DG Set complete all as specified and as directed.
Supply only Lub oil filter for 82.5KVA DG Set complete all as specified and as directed.
Supply only Lub oil filter for 100KVA DG Set complete all as specified and as directed.
Supply only Lub oil filter for 125KVA DG Set complete all as specified and as directed.
Supply only Lub oil filter for 160KVA DG Set complete all as specified and as directed.
Supply only water filter for 160KVA DG Set complete all as specified and as directed.
Supply only fuel filter for 62.5KVA DG Set complete all as specified and as directed.
Supply only fuel filter for 82.5KVA DG Set complete all as specified and as directed.
Supply only fuel filter for 100KVA DG Set complete all as specified and as directed.
Supply only fuel filter for 125KVA DG Set complete all as specified and as directed.
Supply only fuel filter for 160KVA DG Set complete all as specified and as directed.
Supply only Air filter for 62.5KVA DG Set complete all as specified and as directed.
Supply only Air filter for 82.5KVA DG Set complete all as specified and as directed.
Supply only Air filter for 100KVA DG Set complete all as specified and as directed.
Supply only Air filter for 125KVA DG Set complete all as specified and as directed.
Supply only Air filter for 160KVA DG Set complete all as specified and as directed.
Supply only V-Belt set for 82.5KVA DG Set complete all as specified and as directed.
Supply only V-Belt set for 100KVA DG Set complete all as specified and as directed.
Supply only V-Belt set for 125KVA DG Set complete all as specified and as directed.
Supply only V-Belt set for 160KVA DG Set complete all as specified and as directed.
M&L for carrying out repair ,cleaning making leak proof of radiator assembly including filling of coolant replacement of gaskets bolts nuts etc for 160KVA DG set ( Spare parts to be incorporated shall be measured and paid separately under respective items ) complete all as specified and as directed.
All as per item No 29 above but 125KVA complete all as specified and as directed.
All as per item No 29 above but 100 KVA complete all as specified and as directed.
All as per item No 29 above but 82.5 KVA complete all as specified and as directed.
M&L for carrying out repair/overhauling of FIP assembly including replacement of all unserviceable spare parts element and calibration complete of all as directed (Note. The cost of spares /element for overhauling of FIP is deemed to be included in the item ) for 160KVA DG set .
All as per item No 33 above but 125KVA complete all as specified and as directed.
All as per item No 33 above but 100 KVA complete all as specified and as directed.
All as per Ser item No 33 above but 82.5 KVA complete all as specified and as directed.
M&L for carrying out repair /overhauling and calibration of injector assembly including replacement of all worm out spares and proper sealing for 160KVA DG set ( spare parts to be incorporated shall be measured and paid separately complete all as specified and as directed.
All as per item No.37 above but 125KVA complete all as specified and as directed.
All as per item No.37 above but 100 KVA complete all as specified and as directed.
All as per item No 37 above but 82.5 KVA complete all as specified and as directed.
M&L for taking out unserviceable self starter and carrying out repair /overhauling of self starter assembly for 160 KVA set including replacement of all worn out spares including refixing and testing complete.
All as per item No.41 above but 125KVA complete all as specified and as directed.
All as per item No.41 above but 100 KVA complete all as specified and as directed.
All as per item No.41 above but 82.5 KVA complete all as specified and as directed.
S&F repair /replacement of Banjo bolt160/125/100/82.5 KVA complete all as specified and as directed.
S&F in repair/replacement of elbow Hose 160/125/100/82.5 KVA complete all as specified and as directed.
S&F in repair /replacement of clamp 160/125/100/82.5 KVA complete all as specified and as directed.
S&F in repair /replacement of Rectifier kit Dioders & mov Ho6 165/125/100/82.5 KVA complete all as specified and as directed.
S&F in repair/replacement of Carbon Brushes 160/125/100 complete all as specified and as directed.
S&F in repair/replacement Carbon Brushes 82.5 KVA complete all as specified and as directed.
S&F in repair/replacement of Radiator Top & Bottom tank connection Hose 160/125/100/82.5 KVA complete all as specified and as directed.
S&F in repair/replacement of Lube oil Pressure Safety control 160/125/100/82.5 KVA complete all as specified and as directed.
S&F in repair/replacement of high water temp safety control 160/125/100/82.5 KVA complete all as specified and as directed.
S&F in repair/replacement of Gauge Temperature 160/125/82.5KVA complete all as specified and as directed.
S&F in repair/replacement of solenoid switch 160 KVA Make Cummins complete all as specified and as directed.
S&F in repair/replacement of Battery Cable assembly +ve/-ve, complete all as specified and as directed.
M&L for taking out alternator assembly from the base of DG set incl disconnection of cable for carrying out routine maint /major repair at installation in the following phase of work for 160/125/100 KVA DG set make Kirlosker Electric. Dismantling of alternator assembly removing of all dust carbon particle etc from field coil/stator assembly rotor armature assembly exitor unit using carbon Tetra Chloride & blowing of forced air .ii)Carrying out varnishing and heating of field /stater coil and rotor /armature assembly using class ‘’E/H’’ as application insulating varnish (Dr BECK ) including necessary partial replacement of insulting materials viz .insulated cotton type fibre glass tape, empire tubes of different size insulating board /packing/separator materials all as required and as directed by engineer in charge as per existing arrangement iv)Assembling of complete alternator assembly and testing after coupling with phone (Note –i) The requirement of spare parts assessed shall be paid separately under respective items .ii) Cost of Labour for dismantling overhauling & reassembling of alternator including varnishing heating)
All as per item No.57 above but 82.5 KVA complete all as specified and as directed.
M&L for taking out unserviceable battery charging alternator and carrying out repair/overhauling of alternator for 160/125/100 KVA DG set including replacement of following spare parts and refixing ,testing complete .i) Armature -01 ii) Field coil -01 No iii) Carbon Brushes -01 set iv) Carbon Rocker -01 No. complete all as specified and as directed.
All as per item No.59 above but 82.5 KVA complete all as specified and as directed.
Cleaning the internal surfaces of volage stabilizer of size 75 KVA to 120 KVA single/3 phase to free from dust/sediments/rust, removing transformer oil (where ever exists) filtering and refilling, refixing the barrier assembly including connecting all electric/electroni/mechanical components, testing and commissioing complete all as specified and directed by Engr -in- Charge.
All as per item No.61 above but for 400 KVA voltage stabilizer, complete all as specified and as directed.
Disconnecting the input/output electric supply of size From 75 KVA to 120 KVA single/3 phase and Neutral AC 50Hz/single phase conections, removing the cover for taking out defective transformer including disconnecting connected electri/electronic/mechanical components complete all as specified and as directed by Engr -in- Charge.
All as per item No.63 above but for 400 KVA voltage stabilizer, complete all as specified and as directed.
Taking out/removing the defective barrier assembly from the volatage stabilizer of size 75 KVA to 120 KVA manually/using chain pully block, transporting to workshop, removing the burnt windings cleaning and rewinding, with existing size super enamelled copper wire, varnishing, heating and transporting to site for refixing for supply only 05 KVAR capacitorcomplete all as specified and as directed by Engr -in- Charge. Make : Siemens/Epcos/ABB Note : Old burnt copper winding will be measured and issued to contractor under Sch of credit.
All as per item No.65 above but for 400 KVA voltage stabilizer, complete all as specified and as directed.
Repair/Maint of APFC Panel of Capacity 75 KVAR to 100KVAR after disconnecting all connections for fault, finding/trouble shooting and carryout necessary repairing works by replacing the defective spare parts, complete all as specified and as directed.
Supply only 05KVAR capacitor, double metalised (Extra low loss) suitable for APFC panel, complete all as specified and as directed. Make : Siemens/Epcos/ABB/ L&T/ Schnider
Supply only 10KVAR capacitor, double metalised (Extra low loss) suitable for APFC panel, complete all as specified and as directed. Make : Siemens/Epcos/ABB/ L&T/ Schnider
Supply only 20KVAR capacitor, double metalised (Extra low loss) suitable for APFC panel, complete all as specified and as directed. Make :Siemens/Epcos/ABB/ L&T/ Schnider
S&F in-repair of contractor suitable for 20 KVAR capacitor, 415 Volts, complete all as specified and as directed. Make of Contractor - (SIEMENS/LEGRAND/ABB/L&T (MO C20))
S&F in-repair of contractor suitable for 10 KVAR capacitor, 415 Volts, complete all as specified and as directed. Make of Contractor - (SIEMENS/LEGRAND/ABB/L&T (MO C10))
S&F in-repair of contractor suitable for 05 KVAR capacitor, 415 Volts, complete all as specified and as directed. Make of Contractor - (SIEMENS/LEGRAND/ABB/L&T (MO C05))
S&F in-repair of control relay (Auxiliary contractor), 415 Volts, complete all as specified and as directed. Make of Contractor - (SIEMENS/LEGRAND/ABB/L&T (MX-AI 22E))
S&F in-repair of control relay (Auxiliary contractor), 415 Volts, complete all as specified and as directed. Make of Contractor - (SIEMENS/LEGRAND/ABB/L&T (MX0 22E 4P))
Supply installation commission and testing in-replacement of (CPRI Approved) Out door LT Panel board Kiosk type of size1200 x 1000 x 500 mm ,LT415 Volts, 50 Hz , 3-phase,Bus Bar chamber comprising 4 Nos Tin plated copper strip bus bars mounted on DMC (Dough Moulding Compound) insulator and PVC sheathed capacity 500 Amps with colour coding Digital ammeter of 0-500 Amps, voltmeter of 500 Volts and LED type/Neon type Indicating lamps panel mounting type RYB-3 Nos, factory assembled, outdoor type weather and vermin proof (Protection Class IP-54) made out of not less than 60 X 60 X 6 mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet with front & back side hinged opening, rubber lining, locking arrangement, painted externally and internally with powder coating (RAL-7032) after preparation of surfaces in 08 tank sheet process with providing necessary mounting arrangements (P.C.C. block of 1:3:6 of type C-2), complete comprising of following :- (a) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job. (b) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job. INCOMING (c) MCCB 320 Amp , 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 36KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. (Make Legrand,Cat part No-4220 06 , or equivalent in L&T/Havells/ Seimens) OUT GOING (d) MCCB 200 Amp , 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 25KA)Ics=100% of Icu, with spreader terminal of both ends-01 No. (Make Legrand,Cat part No-4202 18 , or equivalent in L&T/Havells/ Siemens) (e) MCCB 100 Amp , 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 25KA)Ics=100% of Icu, with spreader terminal of both ends-03 Nos. (Make Legrand,Cat part No-4200 55 , or equivalent in L&T/ Siemens/Havells) (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication).
KARMIBRINDA
Damdoo Bhutia
HIRA SINGH
Darjeeling Enterprises
R N SAH N CO
M/S TSHERING BHUTIA
MOURICE CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .