Loading…
Loading…
Tender Value
₹25.6 Cr
EMD Value
₹51.2 L
Closing Date
19 Aug 2026, 11:30 am
No
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER LKO
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, whereV= Advertised value of the tender in crore of RupeesN= Number of years prescribed for completion of work for which bids have been invited.The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.The tenderer shall submit requisite information as per Annexure-I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. NOTE FOR TECHNICAL ELIGIBILITY CRITERIA Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered atleast 5 years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit alongwith work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Defination of Similar Work :- Any RI or EI or ABS or IBS/IBH work involving indoor & outdoor work (Cable laying & termination). Note 1: Tenderer may be required to submit the schedule of those works, Completion/Performance Certificates of which have been submitted by him/her in support of 30/40/60 % (as the case may be) criteria of similar nature of work. Note 2: a) Submission of 'Undertaking by the tenderer' that the equipment for EI or Axle Counter or AFTC or UFSBI shall be procured from RDSO approved sources and installation, testing and commissioning of EI or Axle Counter or AFTC or UFSBI shall also be got done from the same source including after sales support required during the warranty period. AND b) The successful bidder shall submit an undertaking from RDSO approved EI OEM, before the supply of material, to confirm compliance with extent RDSO guidelines and to meet contract specific requirements.
15 conditions · 12 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Upload filled & signed Annexure-C:Declaration form regarding site etc.(Format attached with Vol-I of tender document)
Upload filled & signed Annexure-D:"Declaration regarding constitution of firm".(Copy attached with Vol-I of tender document)
Upload filled and signed Annexure-E: List of plant and Machinery.(Copy attached with Vol-I of tender document)
Upload filled and signed Annexure-F: List of Engineers/Personnel (Copy attached with Vol-I of tender document).
Upload filled and signed Annexure-M(A). (Copy attached with Vol-I of tender document).
Upload filled & Signed Annexure-G:Statement of Works executed during last 7 years ending last day of the month previous to the one in which tender is invited (Format available in Vol-I of tender document).
Upload filled and signed Annexure-I:Detail of Contractual Payment received in previous three financial years and the current financial year.(Copy of format available in Vol-I of tender document)
Upload filled & signed Annexure-J:Real Time Gross Saving (RTGS)/National Electronic Fund Transfer(NEFT) Model Mandate Form (copy of format available in Vol-I of tender document)
Upload filled & signed Annexure-L: Completion Certificate(copy of format available in Vol-I of tender document)
Upload filled & signed Annexure-AB: STATEMENT OF DEVIATIONS.(copy of format available in Vol-I of tender document)
Upload filled & signed Annexure K-3 & K-4: If tender submitted on behalf of Partnership Firm, relevant Annexures K-3 and K-4 as Declaration to be submitted by the tenderer alongwith tender document.
Annexure-H (Work in Hand) in support of Bid Capacity) (Applicable for tender value more than Rs.10 crore)
Annexure-N (Maximum value of construction works executed and payment received in any one of the previous three financial years or the current financial year (up to date of inviting tender) in support of Bid Capacity (Applicable for tender value more than Rs.10 crore)
Annexure-Q is to be submitted/uploaded at the time of tendering. If Annexure-Q is not submitted/uploaded at the time of tendering, then the same shall be submitted after issue of LOA and before signing of the Contract Agreement.
"Provision of Indoor and Outdoor signaling works with Electronic Interlocking System (Distributed Type:1 Central and 4 EI Huts) at Vyasnagar station, provision of Electronic Interlocking System for automatic block signalling at Vyasnagar station including modifications required in EI based Automatic signalling in KEI-VYN sections and associated Telecom works of KEI-VYN-DDU sections in connection with yard remodelling of Vyasnagar station with 3rd-4th Line work between BSB- DDU section of Lucknow division of Northern Railways".
287-Sig-CII-LKO-T05-26
287-Sig-CII-LKO-T05-26
Open
Works - General
9 Months
Lucknow, Uttar Pradesh
₹0
₹51.2 L
27 Jul 2026
27 Jul 2026
5 Aug 2026
404 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 25,62,27,591.38 | ||
| — | 1.00 | — | — | ||
| Design, Fabricate & supply of Electronic Interlocking system at Vyasnagar station (Distributed Type: 1 Central and 4 EI Huts) complete as per RDSO specification No. RDSO/SPN/192/2019 ver.2 or latest with amendments, as per special condition of contract and technical specifications (including all relevant and latest RDSO Technical Advisory Note (TAN)) and SIP enclosed mainly consisting of following:Central Microprocessor equipment with HOT standby architecture, Interface equipment as per RE requirement, interface suitable one operator main and one operator stand by VDU, interconnecting cables etc. All types of racks for relays & EI equipments, fixture mounting arrangements and accessories necessary to make EI system functional. Video Display unit control terminal (VDU) having industrial grade fanless PC with minimum 85 inches or more LED Monitor and it's furniture (work station & revolving chair) with UPS minimum one hour backup, maintenance terminal having industrial grade fanless PC with 85 inches LED monitor and it's furniture (Workstation and revolving chair) with UPS minimum one hour backup Supply, OFC connectivity (Patch Cords) as per requirement of system, All type of interface relays used in EI system and Supply, installation, wiring, testing, validation and commissioning of data logger system along with all interface equipment like a protocol converter and Failure Analysis System etc. (required to connect data logger with EI system have to be supplied by contractor as per of this item) DC-DC converter required for EI (110VDC from the battery set of IPS will be provided by railways), Supply & installation of Earthing system with EI, lightening and surge protection device (class A,B,C and D) suitable for EI as per latest RDSO spec. and TAN and their connection with earthing arrangement and accessories necessary to make EI system functional. NOTE-1. Tenderer may quote any RDSO approved EI system with complete details of all module, cards and accessories etc. Along with necessary spares (refer special condition of contract) as per RDSO spec. no. RDSO/SPN/192 of 2019 with latest amendments. Please give full details of quantities for the station and unit base rates item wise, the total amount of which must be equal to the given LAR of this item in separate annexure in a indicative format given in Annexure IV-A of vol.II of tender document. The rate quoted in percentage above/at par/below for entire tender shall be applicable for the rates quoted in the annexure IV -A of vol.II also2. System design should cater to accommodate 15% additional I/Os in future as per para 6.6 of RDSO spec.3. Other details are included in special conditions of contract.(SIP/TSIP of stations are enclosed along with tender document. Inspection: RDSO- Any sub item which is not inspected by RDSO will be inspected by Consignee). | — | — | — | 8,80,38,764.55 | |
| — | 1.00 | — | — | ||
| Automatic Block signalling at Vyasnagar Station as per RDSO specification No.RDSO/SPN/192/2019 ver.2 or latest with amendments, as per special condition of contract and technical specifications (including all relevant and latest RDSO Technical Advisory Note (TAN)), SIP enclosed mainly consisting of following: Central Microprocessor equipment with HOT standby architecture, Interface equipment as per RE requirement, interface suitable one operator main and one operator stand by VDU, interconnecting cables etc. All types of racks for relays & EI equipment's, fixture mounting arrangements and accessories necessary to make EI system functional. OFC connectivity (Patch Cords) as per requirement of system, All type of interface relays used in EI system. DC-DC converter required for EI (110VDC from the battery set of IPS will be used), Supply & installation of surge protection device (class B,C and D) suitable for EI as per latest RDSO spec. and TAN and their connection with earthing arrangement and accessories necessary to make EI system functional. Note: 1. For controlling of Automatic signals in the section, Auto Huts provided shall be connected to CIU at Station detailed plan is to be read from SCC of Tender Document. 2. MSDAC will be deployed for monitoring clearance of Auto section as latest scheme approved by Northern Railway. 3. This includes supply of 15 % spares as per the technical specification of Electronic interlocking. Inspection by RDSO for supply part as per specification. In case of item not being inspected by RDSO will be inspected by Consignee. | — | — | — | 91,74,287.06 | |
| — | 1.00 | — | — | ||
| Supply of "As built" Documents. (i) Completion Documents as per condition of Contract. (6 Sets for each EI) (ii) Supply of documents as per Technical specification Para - 10.2 of RDSO Specification no. RDSO/SPN/192/2019. (6 Sets for each EI). | — | — | — | 87,125.74 | |
| — | 1.00 | — | — | ||
| Supply of Instruments / Tool Kits suitable for EI commissioned:* Tool kit & Measuring Instruments for technicians / Jr. Engineers for Testing, Maintenance, Trouble Shooting and repair at site.Note: Details of tool kit item is enclosed as Annexure -V of Vol.II of Tender Document. Inspection: Consignee. | — | — | — | 1,42,978.34 | |
| — | 6.00 | — | — | ||
| Installation, testing & commissioning of SSI equipments supplied as per item no.1, including transportation from consignee depot to site at stations listed above. Installation is to be done as per RDSO speci. & practice circulated vide TAN no. STS/E/TAN/3012, Ver. 2.0, Dt.10.08.2016, TAN no. STS/E/TAN/3007, Ver. 1.0, Dt.02.11.2012 for industrial grade PC and TAN no. STS/E/TAN/3006, Ver. 1.0, dt. 02.11.2012 for earthing and bonding scheme for Electronic Interlocking.(1 Job=1 Station/Relay Hut) | — | — | — | 25,27,201.8 | |
| — | 10.00 | — | — | ||
| Training for Rly. Tech./JE/SE/SSE by OEM in installation, testing & commissioning, maintenance & trouble shooting of EI system complete including supply of hard/soft copies of course module for each trainee. Competency certificate to trainee to be issued by OEM. All arrangements including classroom, lab, equipment, measuring instruments etc. required for the training should be satisfactorily arranged by the contractor at their own cost. | — | — | — | 8,122.6 | |
| — | 5.00 | — | — | ||
| Training for Rly. Officers by OEM in installation, testing & commissioning of EI system complete including supply of hard/soft copies of course module for each trainee. All arrangements including classroom, lab, equipment, measuring instruments etc. required for the training should be satisfactorily arranged by the contractor at their own cost. | — | — | — | 5,229.8 | |
| — | 70.00 | — | — | ||
| Supply of Relay, Non AC immune, plug in type, style QN1, DC neutral line relay, 24 V DC 8F/8B contacts, front & back contacts metal to carbon with plug board retaining clip & connectors confirming to BRS:931A,IRS:S-45/47/44, IRS:S-45/47/68 & IRS:S-23/88 as applicable.The interlocking code for this unit shall be ABCDF or latest. Inspection: RDSO. | — | — | — | 3,07,391 | |
| — | 140.00 | — | — | ||
| Supply of Relay AC immune, plug in type, style QNA1, DC neutral line relay, 24 V DC 8F/8B contacts, front & back contacts metal to carbon with plug board retaining clip & connectors confirming to BRS:931A,IRS:S-45/47/44, IRS:S-45/47/68 & IRS:S-23/88 as applicable.The interlocking code for this unit shall be ABDGH or latest. Inspection: RDSO. | — | — | — | 6,51,247.8 | |
| — | 5.00 | — | — | ||
| Fabrication, supply and fixing of relay racks of size 2200mmx690mm (as per approved Drg. No. NR/S&T/CON/4.3/97A) made of angle iron size 45mmx45mmx6mm alongwith outer frame made of angle iron size 65mmx65mmx8mm, fitted with M.S. squares bars duly galvanized, descriptions strips to accommodate Plug-in-type relays/groups/Point contractor units/ECRs/HMUs. All fixing material like antilting device, hylam sheets if required, bolts & nuts, washers, insulators, shoe, angle irons, flats, L-bolts, Catenary wires and cement concrete etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting & description etc. with ISI mark paints. | — | — | — | 97,166.25 | |
| — | 20.00 | — | — | ||
| Fabrication, supply and fixing of cable termination board of size 2200mmx900mm as per Drg. No. NR/S&T/CON/4.1/97A made of angel iron size 40mmx40mmx5mm alongwith outer frame made of angle iron size 65mmx65mmx8mm duly fitted with Bakelite sheet (HYLAM MAKE or similar) of size 6mm thick. This also includes fixing of ARA terminals/strips/Wago connectors & fuse bases etc. Supply and fixing of hard wood of size 70cmx25cmx4cm in the back at bottom for jamming of armour of cables, each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. All the fixing materials like bolts, nuts, washers, Insulators, shoe, angle irons, flats, L- bolts, Catenary wires & cement concretes etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting & description etc. with ISI mark paints. | — | — | — | 4,37,143.6 | |
| — | 450.00 | — | — | ||
| Fabrication, supply and fixing of scaffolding /cable carrier made of angle ironof Size 35mmX35mmX5mm and flat of size 25mmX3mm as per instructions of engineer at site.The space between two flats will be 25cm or less as per site requirements allthe fixing materials i.e nut, bolt washer, insulators, cement concrete etc will be supplied by the contractyor . This includes insulating flat strips, cleaning priming by Red oxide, painting by ISI mark paint. | — | — | — | 2,36,929.5 | |
| — | 12.00 | — | — | ||
| Supply of Flexible, PVC sheathed, PVC insulated Copper wire 16/.20 sq.mm. (wiring materials) as per IRS spec. No. IRS-76/89 with amendment no.3 or latest. (From RDSO Approved Source only). Inspection: RDSO. | — | — | — | 1,10,117.64 | |
| — | 5.00 | — | — | ||
| Supply of Indoor cable 60x1mm indoor copper conductor 60 core plain annealed high conductivity PVC insulated unamoured as per Spec. no. IRS-S/76/89 (Amd 3) or latest amendment. (From RDSO Approved Source only). Inspection: RDSO. | — | — | — | 24,20,648.3 | |
| — | 120.00 | — | — | ||
| Wiring of relays in relay room/relay huts as per appd wiring diagrams. All wiring material including resistances and condensers etc. except cables/wires to be supplied by contractor (Supply of cables & wires covered separately). It also includes dressing, bunching, lacing and fixing of relay bases. | — | — | — | 60,190.8 | |
| — | 600.00 | — | — | ||
| Supply of electric fuse complete with fuse block(base) for Railway signalling non- detoriorating type low voltage fuse assembly 2Amp/4Amp/16Amp. to suit Specn. No.IRS: S-78/2006 and fuse block made of PBT/Polycarbonate as per IRS: S-75/2006 (Rev.2 & Amd.2) and drg no. 23748 (IRS), Alt-4 or latest. Fuse block shall be suitable for round head type fuses. Inspection: RDSO. | — | — | — | 1,25,142 | |
| — | 5.00 | — | — | ||
| Supply, installation & wiring of Earth leakage detector (12 Channel) for monitoring different AC and DC, supplies including all accessories as per RDSO specfication no.RDSO/SPN/256/2002 or latest and stipulations of tender docment. Inspection: RDSO for supply portion. | — | — | — | 8,36,660.9 | |
| — | 2.00 | — | — | ||
| Supply of Portable digital auto range multi-meter clamp type Philips, Motwani, Fluke or Rishabh make capable to measure from (0.1mv/0.01ma) AC/DC upto 50Amp(AC/DC), 600V(AC/DC) and 0.1 ohms- 40M ohms suitable for measurement of Freq., capacitance complete with Manual, leads, battery and holster etc. Inspection: Consignee. | — | — | — | 16,849.16 | |
| — | 1.00 | — | — | ||
| Supply of tool kit for JE/SE/SSE for Maintenance as per tech spec. given below: (1) Digital Multi Meter suitable for axle counter ranges 20 Amp AC/DC make protek 506 or similar- 1 no. (2) Digital clamp Multi Meter range up to 100 Amps for AC/DC current make SEW or similar - 1 no. (3) Leather Tool Bag for keeping tool kit -1 no. (4) Plier Sealing with sealing code bit -1 no. (5) Plier Wire Cutting 8" make Taparia or similar -1 no. (6) Nose Plier 4" make Taparia or similar -1 no. (7) Wire Stripper - 1 no. (8) Screw Driver set mutli port type -1 set. (9) Track shunt resistance .5 ohm -1 no. (10) Soldering Iron 230V AC/65 watt -1 no. (11) Soldering Iron 230V AC/35 watt with diffrerent type replacement soldering head - 1 no. (12) Soldering Iron 110V AC/35 watt -1 no. (13) Mesuring Tape steel 30 meters - 1 no. (14) Mesuring Tape steel 3 meters - 1 no. (15) Rechargable Torch Superior quality -1 no. (16) File Flat 8" long - 2 nos. (17) File Round smooth 8" long - 2 nos. (18) File Flat Bsterred 8" long - 2 nos. (19) Electric Drill Machine Portable 6mm make wolf or similar -1 no. (Inspection: Consignee) | — | — | — | 54,121.79 | |
| — | 22.00 | — | — | ||
| Supply fixing and wiring of Fuse Auto Changeover System (FACS main system) as per RDSO/SPN/209/2012 Rev. 2.0 with latest amendments. One automatic changeover unit comprise 32 nos of external Non Deteriorating Type or 'G' type fuses of various Ampere Rating, working voltage- 24 VDC which are in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. Installation , wiring, Testing and commissioning of Fuse Alarm System,it consists of fixing of modules of fuse alarm system on existing relay rack, wiring from existing fuses to modules, soldering, lacing etc. working to be executed without affecting the functioning of the existing Circuits/Gears and the work shall be supplied by the contractor. Inspection: RDSO for supply portion. | — | — | — | 9,43,768.98 | |
| — | 40000.00 | — | — | ||
| Supply of 4 conductor dis-connect terminal block for test and measurement 0.8 sq.mm-2.5 sq.mm centre marking with test slot for test plug 2mm/0.079IN and 2.3mm/0.091IN carreir rail DIN 35 front entry cage clamp connection Grey wago or similar as RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection: RDSO. | — | — | — | 48,29,600 | |
| — | 800.00 | — | — | ||
| Supply of Steel carrier Rail 35x7.5mm/0.039 in thick unslotted, yellow with Chrome Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection: Consignee. | — | — | — | 1,24,120 | |
| — | 8000.00 | — | — | ||
| Supply of End and Intermediate Plate 2.5mm/0.098 in Thick Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection: Consignee. | — | — | — | 1,54,640 | |
| — | 8000.00 | — | — | ||
| Supply of screw less end stop 10mm/0.394 in wide carrier rail DIN 35 Grey Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. Inspection: Consignee. | — | — | — | 1,35,680 | |
| — | 5.00 | — | — | ||
| Fabrication, wiring and supply of simulation panel as per drawing no. SSTE/PS/1562 dt.05.09.2001. This includes wiring from Relay room to the simulation panel. ARA terminals and fuse bases shall be supplied by Railway. All materials such as on/off/2way switches, wires, strips & tag blocks etc. to be supplied by the contractor. (Only indoor cables for wiring between relay room and simulation panel shall be supplied by Railways). | — | — | — | 31,362.7 | |
| — | 5.00 | — | — | ||
| Fabrication, wiring and supply of lamp board as per drawing no. SSTE/PS/1563 dt.05.09.2001. This includes wiring from Relay room to the lamp board. All materials such as wires, strips, tag blocks, lamps & holders etc. including sufficient lamps for testing to be supplied by the contractor. (Only cables for wiring between relay room and lamp board shall be supplied by Railways). | — | — | — | 52,862.35 | |
| — | 5.00 | — | — | ||
| Installation, wiring and testing of Integrated Power Supply System. This includes power distribution connection to bus bar and relay racks in the room and fabrication and fixing of AC/DC power distribution board made on 10mm thick Phenolic laminated sheets or any standard make with connections suitable for 32 Amp. as per site requirement. Wiring to be done with flexible cable, single core multi strand 6 sq. mm as per spec-IRS-76/89 with latest amendment from AC distribution board to Integrated Power Supply system. Wiring to be done with Flexible Cable, Single core, multi strand 10sq mm. as per spec IRS 76/89 with latest amendment from integrated power supply system to D.C. bus bar. All connections as per site requirement to be arranged by contractor as per RDSO guidelines and instruction of railway engineer at site. This item includes fixing of ladder along the wall for carrying of power supply wires/cables from IPS room to relay room/ power room / Battery room etc. | — | — | — | 3,00,974.45 | |
| — | 6.00 | — | — | ||
| Supply of power wires 1x6sq.mm. (Red & black), IS 694/2010 or latest. Inspection: RDSO | — | — | — | 3,74,434.92 | |
| — | 4.00 | — | — | ||
| Supply of power wires 1x16sq.mm. (Red & black), IS 694/2010 or latest. Inspection: RDSO. | — | — | — | 6,81,512.88 | |
| — | 2.00 | — | — | ||
| Supply of power wires 1x25sq.mm. (Red & black), IS 694/2010 or latest. Inspection: RDSO. | — | — | — | 5,63,298.7 | |
| — | 10.00 | — | — | ||
| Supply of 3 phase Manual changeover switch 63Amps/100Amps. Siemens/ Havells or similar Iron Clad switch. Inspection: Consignee. | — | — | — | 59,716.1 | |
| — | 1.00 | — | — | ||
| Preparation of cable route plan, Cable core chart, Power supply arrangement plan for indoor and out door, Cable termination chart in relay room and location boxes, Location wiring plan, Cable insulation chart and register, Track circuit history card, Fuse analysis plan, Equipment disposition plan, Track circuit jumpering plan, Terminal and Contact analysis chart, Outdoor circuits, pull sheets, gomettie plans,diagrams. temp. plans required for execution of PNI/NI and other outdoor diagram and obtaining approval of the Engineer as per following :- (i) Supply of 6 copies of completion set of superior quality paper, laminated, properly bound in steel clip jaw file with cushioned cover. (ii) Software back up of complete set in the form of CDs. (iii) One complete set of tracings. (iv) Design through CAD. (v) Drawings in A3 & plans in bigger size. (six sets). | — | — | — | 49,635.87 | |
| — | 52000.00 | — | — | ||
| Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No.NR/S&T/CON./1.1/97A so as not to form a drain 0.3 mtrs. wide & 1 mtr. deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable plan. It also includes clearance of roots of trees & bushes. | — | — | — | 44,23,640 | |
| — | 416000.00 | — | — | ||
| Supply and laying of 2nd class bricks in the trench and laying as per Drg. No. (NR/S&T/Con./1.1/97A) and as per instruction of the site Engineer. | — | — | — | 37,39,840 | |
| — | 1040.00 | — | — | ||
| Fabrication, supply and fixing of concrete cable marker as per RDSO drg. No. SDO/Cable Laying/020, dt.31.10.11. The marker shall be fixed at various places of cable route as per instruction of Eng. at site. | — | — | — | 15,33,937.6 | |
| — | 1040.00 | — | — | ||
| Supply and installation of RFID Electronic Marker for S&T underground cable with programmable memory chip, later recordable by electronic marker locator during locating (10 cm diameter with floating coil to keep detection circuit always Horizontal for better detection) which can be buried to depth of 5 ft. Placing in trench. Inspection by RITES for supply portion. | — | — | — | 31,50,430.4 | |
| — | 1.00 | — | — | ||
| Supply of 3M/ or similar make integrated Dynatel Electronic Cable/Pipe/Route Tracer /Locator (with inbuilt marker locator) high power 12 w transmitter for effective long distance locating, 6 active locating frequencies (577 Hz, 1 KHz, 8kHz, 33 kHz, 82 kHz, 200 kHz), depth range upto 9 meter, passive power frequency, Current and resistance measurement in both transmitter and receiver, super induction mode, with capability of Electronic marker locating (both passive and RFID) and cable route locating in a inghel equipment, receiver with Bluetooth wireless technology, GPS interface (internal, 3m) allows software to be downloaded from website, weight less than 2.5 Kgs for Transmitter as well as receiver, Signal current measurement in cable, (Model No. 2550XID). Inspection by RITES for supply portion. | — | — | — | 5,45,603.55 | |
| — | 200.00 | — | — | ||
| Excavation and refilling of trench 0.3 mtrs wide and 0.8 mtrs deep on pitched/stone/bricks paved surface, road/crossing/platform etc and restoring the surface to its original condition. | — | — | — | 24,028 | |
| — | 900.00 | — | — | ||
| Supply & installation of HDPE double Wall Corrugated (DWC) Pipe as per as per RDSO Specification No. RDSO/SPN/204/2011 Ver. 1.1 With Amndt-1 (outer dia 120mm in 6m st. length with one coupler for every 6m length). This include brick work and other arrangements required to secure the pipe as per specifications, drawings and stipulations of tender documents and as per approved cable route plan including road crossing/platform/track crossing and for bridges and culverts etc. Inspection: Consignee for supply portion. | — | — | — | 4,69,359 | |
| — | 900.00 | — | — | ||
| Supply and fixing of G.I. pipe 75mm dia, 3mm thick as per spec no IS-1239, perforated at a distance of 20 CM or less of required length at culverts/ bridges/along the cuttings, suitably concreted at both ends as per approved drg. No.Drg. No.NR/S&T/CON/1-4/97.or at ASM office/other buildings suitably fixing it to the wall and at both ends. G.I. clamps of M.S. flats bolts and nut, to be supplied by the contractor. Inspection: RITES for supply portion. | — | — | — | 8,12,943 | |
| — | 3000.00 | — | — | ||
| HDD Boring & Trenchless of 120mm dia without HDPE pipe for laying of signalling / telecom /power cable under track/road/culvet etc cable laying is covered seperately. | — | — | — | 30,64,440 | |
| — | 4500.00 | — | — | ||
| All work of horizontal boring and trenchless cabling along with supply,transpotation and insertion of double wall corrugated pipe -(ISI marked ) conforming to RDSO Spec no. RDSO/SPN/204/2011 or latest, and the laying of cable in the boring under the track / road etc as per instruction of site engg. by using pipe of size 120 mm outer dia, 103.5 mm inner dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 mtr. from rail flange/road level. Inspection: RITES for supply portion. | — | — | — | 95,63,760 | |
| — | 400000.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per approved Drg. No. NR/S&T/CON/1-1/97C and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables. | — | — | — | 38,68,000 | |
| — | 40000.00 | — | — | ||
| Testing & meggering of all types of outdoor cables after its laying and termination on both ends under supervision of Railway representative. This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately after termination of cable. This also includes dressing & lacing of cable on both ends. Performa for testing & material for lacing to be supplied by the contractor. | — | — | — | 6,34,400 | |
| — | 210.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of apparatus case single as per Drg. No.NR/S&T/Con./2.7/97. A layer of 3mm of Bitumin compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement, sand, aggregate & anchor bolts shall be supplied by the contractor. Contractor is required to execute all type of repair work of foundation if required during inserting the cable for termination. | — | — | — | 14,14,660.8 | |
| — | 210.00 | — | — | ||
| Supply of single apparatus case steel RE with 'E' type locks and key ward No 42 & handle as per Drg No. RE/S&T/ALD/SK/219/82 & 221/82 with Alt.B . Inspection:RITES. | — | — | — | 53,53,740 | |
| — | 70.00 | — | — | ||
| Preparation of App. Case single involving wiring of relays: Preparation & fixing of bakelite hylum sheet 910x800x6mm and bakelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, Q series relays and other type relays on square bars fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Bakelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). Relays, ARA terminals only shall be supplied by the Railways. | — | — | — | 4,88,105.8 | |
| — | 100.00 | — | — | ||
| Preparation of App. Case single not involving wiring of relays: Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). ARA terminals only shall be supplied by the Railways. | — | — | — | 5,73,003 | |
| — | 40.00 | — | — | ||
| Preparation of App. Case to be used as battery box (not requiring shelf and hylum of size 910x150x6mm only is reqd.): This includes fixing of fuses, ARA terminal and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including hylum board, salwood plank, wire and wiring material, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). ARA terminals only shall be supplied by the Railways. | — | — | — | 1,30,522.4 | |
| — | 130.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of half apparatus cases of size (670mmx760mm) and 650mm deep as per Drg.No.NR/S&T/CON/2.8/97. A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement,coarse sand,aggregate and anchor bolt shall be supplied by contractor. App. Case half will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. | — | — | — | 7,74,788.3 | |
| — | 130.00 | — | — | ||
| Supply of apparatus case steel RE half with 'E' type locks and key ward No 42 & handle as per Drg No. RE/S&T/ALD/SK/220/82 & 221/82 with Alt.B . Inspection:RITES. | — | — | — | 24,34,194.1 | |
| — | 80.00 | — | — | ||
| Preparation of App. Case half involving wiring of relays: Preparation & fixing of bakelite hylum sheet 450x800x6mm and bakelite shelf 450x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, Q series relays and other type relays on square bars fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Bakelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires , nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). Relays, ARA terminals only shall be supplied by the Railways. | — | — | — | 3,67,499.2 | |
| — | 50.00 | — | — | ||
| Preparation of App. Case half not involving wiring of relays: Preparation & fixing of bakelite hylum sheet 450x800x6mm and Backelite shelf 450x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). ARA terminals only shall be supplied by the Railways. | — | — | — | 1,92,634 | |
| — | 40000.00 | — | — | ||
| Supply of terminal block 25mm center M-6 (ARA terminals) as per IRS spec. No.IRS-S- 75/2006 (Rev.2) & IRS drawing No. SA-23741A(Alt.4), SA-23745(Alt.5), SA-23746 & SA-23756(Alt.3). Inspection:RDSO. | — | — | — | 32,56,400 | |
| — | 57.00 | — | — | ||
| Casting, concreting and curing of foundation for main signal of size (1,041mm X 1,041mm) at bottom and (711mm X 711mm) at top and 1,750mm deep as per Drg. no. NR/S&T/CON./2.1/97 all material such as anchor bolts, cement, sand aggregate to be supplied by contractor. | — | — | — | 7,13,018.7 | |
| — | 50.00 | — | — | ||
| Supply of color light signal post 3.6m and ladder 3.5M with bases as per IRS specification No. IRS-S-6-81, Rev-3 or latest. Inspection: RITES. | — | — | — | 9,59,689.5 | |
| — | 13.00 | — | — | ||
| Supply of colour light signal post 4.6m and ladder 4.5M with bases as per IRS specification No. IRS-S-6-81, Rev-3 or latest. Inspection: Consignee. | — | — | — | 2,84,665.68 | |
| — | 36.00 | — | — | ||
| Supply of 2 Aspect color light signal unit complete without holders, lamps, lenses and signals transformers, as per RDSO Drg. No. SA-23003 A/M (Adv), Alt-9 or latest, spec. IRS-S-26/64, Rev.1 or latest. Inspection: RITES. | — | — | — | 6,67,372.68 | |
| — | 5.00 | — | — | ||
| Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the commissioning, fixing of LED aspect, current regulator and hoods of CLS unit, terminating cables, wiring the CLS unit and focusing the signal. Elevation & distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways and as per NR practice. All items for the above works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets, ii) Wooden cross arm 1 mtr. x 1 mtr., iii) MS angle and MS sheet for blanking of ladder, iv) Supply and fixing of signal number plate (Retro reflective) with complete fittings as per standerd railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc for the following: (a) Installation, erection, wiring of 2 aspect color light signal. | — | — | — | 16,396.25 | |
| — | 17.00 | — | — | ||
| Supply of 3/4 Aspect colour light signal unit complete without holders, lamps, lenses and signals transformers, as per RDSO Drg. No. SA-23002 A/M (Adv), Alt.-9 or latest,SA-23001 A/M (Adv), Alt.-9 or latest respectively, spec. IRS-S-26/64 or latest. Inspection: Consignee. | — | — | — | 3,92,196.97 | |
| — | 10.00 | — | — | ||
| Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the commissioning, fixing of LED aspect, current regulator and hoods of CLS unit, terminating cables, wiring the CLS unit and focusing the signal. Elevation & distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways and as per NR practice. All items for the above works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets, ii) Wooden cross arm 1 mtr. x 1 mtr., iii) MS angle and MS sheet for blanking of ladder, iv) Supply and fixing of signal number plate (Retro reflective) with complete fittings as per standerd railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc for the following: (a) Installation, erection, wiring of 3/4 aspect color light signal. | — | — | — | 46,247.9 | |
| — | 15.00 | — | — | ||
| Supply of 1-way route indicator junction type as per drg. No. SA-23401 (adv.) or latest complete with hoods & offset bracket 5 1/2" as per specn.no.IRS-S-66/84 (Amd-1) or latest, drg.no. SA23402(Adv), Alt.-2 or latest. Inspection: Consignee. | — | — | — | 4,24,398.15 | |
| — | 24.00 | — | — | ||
| Supply of 2-way route indicator junction type complete with hoods & offset bracket 5 1/2" without holders, lamps, lenses and signal transformer as per RDSO specn.no.IRS-S-66/84, Amd.1 or latest drg.no. SA 23402(Adv), Alt.-2 or latest.Inspection:RITES | — | — | — | 7,73,671.92 | |
| — | 6.00 | — | — | ||
| Supply of 3/4/5/6-way route indicator junction type as per drg. No. SA-23403 (adv.) or latest complete with hoods & offset bracket 5 1/2" as per specn.no.IRS-S-66/84 (Amd-1) or latest, drg.no. SA23402(Adv), Alt.-2 or latest. Inspection: Consignee. | — | — | — | 2,15,509.5 | |
| — | 14.00 | — | — | ||
| Supply, fixing & wiring of Multi Lamp Route Indicator (LED Single Digit) from 1 to 9 & G route with metal housing as per specification: 1. Single digit LED route indicator capable of displaying 1 to 9 & route 'G'. 2. Visibility of 300 mtr. in clear day light. 3.Option for white color, chromaticity as per BS:1376 standard. 4. Built with robust AlInGaP (Aluminum-Indium-Gallium- Phosphide), InGaN (Indium-Gallium-Nitrate) LED's with junction temperature >100. 5. Lamp proving compatible with AC LED ECR. 6. Input operating voltage: 110V AC +/- 20%. 7. Uniform intensity over entire operating range. 8.Operating temperature -10 to + 60. 9. Operating current: 105mA to 168mA. Inspection: RITES for supply portion. | — | — | — | 10,90,453 | |
| — | 40.00 | — | — | ||
| Installation, erection and wirng of 2/3/4 aspect LED lit colour light signal including 1/2/3/4/5/6 way Jn. type/Stencil/Theatre type route indicator which also includes fixing of route indicator on the top of the signal post or on offset bracket including fixing of offset bracket, wiring the whole unit, focussing of signal & route indicators. All items for installation and erection (excluding unit junction type route indicator and offset bracket covered separately) to be supplied by the contractor. Wiring & other fixing material, 'U' bolts will also be supplied by the contractor. | — | — | — | 1,88,852.4 | |
| — | 20.00 | — | — | ||
| Fabrication, Supply and fixing of retroreflective P/G/C/A-markers with complete fittings as per approved Drg. No. NR/S&T/CON/6.2/97. All material required for the job such as MS sheet, MS angle. Nut and bolts, paint and painting materials will be supplied by the Contractor. The P and G markers shall be as per Drg. No.S 23456(Adv) & SA 23477(Adv) respectively. | — | — | — | 17,153.8 | |
| — | 14.00 | — | — | ||
| Casting, concreting, curing of foundations of size (400mmx300mm) at surface and 1000mm deep and erection of retroreflective SLB/BSLB/SB/ calling on boards/Goods Warning Board/Passanger Warning Board as per drg. No. NR/S&T/CON/7.4/97 & provisions of SEM. It includes supply of retroreflective SLB/BSLB/SB/ calling on boards/Goods Warning Board/Passanger Warning Board. The SLB/BSLB shall be as per approved Drg. No.SA-2373 or latest. | — | — | — | 1,45,083.54 | |
| — | 5.00 | — | — | ||
| Supply of calling-on with offset bracket 3.5" dia. Type as per drg.no.SA 24351- 52(Adv) or latest and spec.no.IRS-S-23/88. or latest. Inspection: Consignee. | — | — | — | 26,715.3 | |
| — | 43.00 | — | — | ||
| Installation, erection & wiring of LED lit C/ON signal /dependent shunt signal /illuminated 'A' marker/ 'AG' marker/ 'F' markers on the same post below the mainn signal on offset bracket. The wiring material to be supplied by contractor. It includes fixing of LED signal unit and hoods, wiring and focussing of the signal. Supply of offset bracket, calling-on signal/Shunt signal complete is covered as seperate item of schedule. 'U' bolt for offset bracket wire and wiring material will be supplied by contractor. | — | — | — | 47,831.48 | |
| — | 96.00 | — | — | ||
| Supply and installation signal number Drg.No.11393. Inspection: Consignee or Site Incharge. | — | — | — | 68,501.76 | |
| — | — | — | type | ||
| — | 38.00 | — | — | ||
| Supply of shunt signal position light complete with unit offset bracket 3.5" dia as per drg.no SA 23840(adv) to SA 23848 (adv), specs.no.IRS-S-23/88(Dependent type). Inspection: Consignee. | — | — | — | 3,99,285.76 | |
| — | 29.00 | — | — | ||
| Supply of shunt signal position light complete with unit post and surface base as per drg.no SA 23840(adv) to SA 23848 (adv) & specs.no.IRS-S-23/88 (Independent post type). Inspection: Consignee. | — | — | — | 3,04,791.45 | |
| — | 29.00 | — | — | ||
| Casting, concreting and curing of foundation of Shunt signal/ 'F' marker of size 855mm x 855mm at bottom and 711mm x 711mm at top and 750mm deep as per Drg No.NR/S&T/Con /2.1/97A. All material such as Anchor bolts, cement, sand, sand stone aggregate to be supplied by the contractor. | — | — | — | 1,24,578.78 | |
| — | 29.00 | — | — | ||
| Installation, erection & wiring of independent position light shunt signal/F marker, this includes fixing of shunt signal, surface base signal post, LED unit, hood and all wiring & fixing material such as U' bolt, nuts, washer, wire,wire mesh etc. will be supplied by contractor. | — | — | — | 39,089.68 | |
| — | 41.00 | — | — | ||
| Supply of Electric Point Operating Machine: IRS Type with AC Immunity of 160 VAC, Non Trailable to operate on 110 VDC, 143 mm throw with interlocking complete with lock, detector, cable terminal box and slides for lock and detector, Rotary locking as per specification No.IRS-S- 24/2002 with amendment -1 or latest with latest amendments. Tools and Accessories to be supplied as per Clause 20 (With Latest Amendments) of IRS: S 24-2002 or latest with latest amendments. with every 08 Sets rounded off to next higher number. Inspection: RDSO. | — | — | — | 28,62,483.06 | |
| — | 60.00 | — | — | ||
| Supply of Electrical Point Machine: Non-trailable type, Conforming to RDSO Spec no.IRS.S.24/2002, amendment no.1 or latest with latest amendments with the following parts: (a) 220 mm Throw with interlocking for Operation of the point as per RDSO Drg. no.S11000 with AC immunity of 160 Volt (RMS), 50HZ. (b) Clamp point lock 60KG for BG as per RDSO Drg no.S-3395A, (c) Switch extension Bracket (P-Bracket) and insulation Plates as per RDSO drg. no.S-3591, 3592 & 3593, (d) Detectorrods (Long & Short) as per RDSO drg. no S-3594-95, Lock rods (Long & Short) as per RDSO drg. no.S-3596-97, (e) Drop lug as per RDSO drg. no.S-3598 including all insulations, accessories and Tools and Accessories to be supplied as per Clause 20 (With Latest Amendments) of IRS: S 24-2002 or latest with latest amendments with every 04 Sets rounded off to next higher number. Inspection: RDSO. | — | — | — | 58,26,840 | |
| — | 101.00 | — | — | ||
| Fixing, wiring, Testing, adjustment of Point Machine as per standard practice. Its also includes: i) Fixing of switch extension 'P' bracket, providing insulation for switch extension bracket, fixing ground connections, adjusting the correct opening of switches and adjusting the point machine with crank handle.ii) Wiring inside the point machine, erection & wiring of JB with lock & key as per drawing, provided with terminal strips (if required). iii) Supply & fixing of GI pipes with flange for taking cable in to point machine and jn. Box through gland/GI pipe. iv) Complete material for installation viz. point insulation material, Jn. box, GI pipe, gland pipe, wiring material, nut & bolts of various sizes, angle iron of size 75mmx75mmx10mm, channels for fixing the machine, lugs for point rodding and insulation materials for stretcher bar 90R/52kg/60kg as per . drg.no.SA-23171 (adv.) Alt.1 will be supplied by the contractor. v) Smithy and fitting work required at site for complete installation of Gauge tie plate and insulation of GTP as per approved Drg.no.NR/S&T/CON/7-6/97 and william stretcher bar (if reqd.) will be done by the contractor. Machine shall be overhauled by contractor if required. vi) This includes removal of existing gears and fixing the machine at raised level on channel as per standard practice to avoid flooding wherever required. vii) Supply of ground connections of electric point machine, non insulated GTP & CTP extension plate,Jn. box and stretcher bar shall be made available by the Rlys. in which the supply of ground connections, Jn box is covered separately. | — | — | — | 9,75,064.1 | |
| — | 41.00 | — | — | ||
| Fabrication & Supply of complete set of point rodding for point machines of IRS type or its equivalent type as per . drg. No.SA 8800-01 (Adv) or latest along with 'P' brackets and 'L' bracket required (Coal for smithy work, all type of nuts & bolts and Lugs as reqd also to be supplied by contractor with each set). Inspection: Consignee. | — | — | — | 4,54,876.55 | |
| — | 41.00 | — | — | ||
| Supply of Insulation for 'L' type bracket for point fitting IRS type complete consisting of instulation Plate - 01No. Ferrule-02nos., Washers-04Nos. (Material Nylon 66). Inspection: by consignee. | — | — | — | 18,968.24 | |
| — | 82.00 | — | — | ||
| Supply of Insulation for 'P' bracket for point fitting IRS type complete, insulation Plate - 01No. Ferrule-02nos., Washers-04Nos. (Material Nylon 66). Inspection: Consignee. | — | — | — | 97,534.08 | |
| — | 101.00 | — | — | ||
| Supply and fixing of spigot for point machines (Job = Per Pt. Machine). | — | — | — | 25,674.2 | |
| — | 60.00 | — | — | ||
| Supply, installation and wiring complete KLCR and its box in location boxes, supply, installation, wiring of heavy-duty push button, LED indicator on MS sheet as per N.R. practice for crank handle locking. This work includes fixing & wiring of magneto telephones as per instructions of the site Engr. This includes all materials such as heavy-duty push button, LED indicator (10mm), MS sheet of 4.5mm thick, nuts and bolts, fixing materials for the magneto telephone, and wiring materials to be supplied by contractor. Inspection: RDSO for supply portion. | — | — | — | 11,66,298.6 | |
| — | 100.00 | — | — | ||
| Installation of Berthing and straight DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement: (a) Drilling of holes 7.2 mm diameter or size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastened with fish plates and bolts at each joints including transverse bonding with rope wire. 8 SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes continuity of joint on rail web for TLJB/BOOTLEG bonding method, terminating the jumpers in the TL JB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to be done by contractor. Supply of insulation materials for insulated block joints is not included. (d) Fixing of TL JBs as per drawing No.(NR/S&T/CON/3.2/97A) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TLJBs will provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 15 Ohms, track relays, choke B type (at Feed End & Relay End) & batteries as per the standard practice using fuses and terminals. This includes supply of all material by contractor as per RDSO specifications (as applicable) except supply of TF battery charger, batteries, relays which are covered separately. (f) Commissioning of track circuits as per provisions of Paras under IRS spec. S-36/87, Amd.2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Track history card should be supplied by the contractor. | — | — | — | 16,10,377 | |
| — | 53.00 | — | — | ||
| Installation of Point track circuit having single point (excluding traps) DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement: (a) Drilling of holes 7.2 mm diameter or size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastened with fish plates and bolts at each joints including transverse bonding with rope wire. 8 SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes continuity of joint on rail web for TLJB/BOOTLEG bonding method, terminating the jumpers in the TL JB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to be done by contractor. Supply of insulation materials for insulated block joints is not included. (d) Fixing of TL JBs as per drg. No. (NR/S&T/CON/3.2/97A) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TL JBs will provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 12 Ohms, track relays, choke B type (at Feed End & Relay End) & batteries as per the standard practice using fuses and terminals. This includes supply of all material by contractor as per RDSO specifications (as applicable) except supply of TF battery charger, batteries, relays which are covered separately. (f) Commissioning of track circuits as per provisions of Paras under IRS spec. S-36/87, Amd.2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Track history card should be supplied by the contractor. | — | — | — | 12,99,293.94 | |
| — | 168.00 | — | — | ||
| Supply of QTA2 relays AC immunized plug in type DC 9 Ohm neutral track relay miniature tractive armature with 2F/1B contacts as per BRS: 939A or latest amendments, BRS:966- Append.F2, IRS-S@45"44@ IRS-S-23 & IRS:S-60 (as applicable). Inspection: RDSO. | — | — | — | 10,12,912.32 | |
| — | 160.00 | — | — | ||
| Supply of Track Feed Charger 110AC/2-4-6 VDC/10Amp. As per RDSO Spec. No.89/2013 (Amd.1) or latest from RDSO approved firm. Inspection: RDSO. | — | — | — | 7,74,188.8 | |
| — | 490.00 | — | — | ||
| Supply of sec. cell low maintenance 2 V/ 80 AH conforming to IRS S-88/2004, Rev.1 or latest with micro porous vent plugs cum floats with inter cell connectors, nuts, bolts, washers etc. Inspection: RDSO | — | — | — | 16,33,047.5 | |
| — | 15.00 | — | — | ||
| Relay, AC Immune, Plug-in type, Style 'QBAT', DC biased track, 9 ohm, 2F/2B contacts, front and back contacts metal to carbon complete with plug board, retaining clip & connectors conforming to RDSO/SPN/84, Ver 2.0 Along with IRS:S-23, S-34 & IRS:S-60 (as applicable). The interlocking code for this unit shall be ABEJX. Inspection: RDSO. | — | — | — | 94,210.65 | |
| — | 6.00 | — | — | ||
| Supply of Hydrometer Exide make for measuring specific gravity of battery, graded acid with mounting stand in location boxes. | — | — | — | 1,704.78 | |
| — | 650.00 | — | — | ||
| Supply, fixing and wiring of PPTC Fuses 2/6A make tyco/Raychem/Bourn/Fuzetech/ Little Fuse or similar. Inspection: Consignee for supply portion. | — | — | — | 5,310.5 | |
| — | 470.00 | — | — | ||
| Charging of 80AH secondary batteries (with contractor's charging equipment) as per standard procedure. All the charging materials i.e. sulphuric acid confirming to latest IRS specifications and distilled water confirming to latest specifications will be supplied by the contractor. This also includes installation of secondary batteries, their inter-connections & writing work as per directions of site Engineer. | — | — | — | 1,14,806.9 | |
| — | 254.00 | — | — | ||
| Supply of field IoT device or Mini logger with basic function of capturing the parameters from the Point Machine, DC Track circuit. Inspection: RITES. | — | — | — | 2,01,49,687.92 | |
| — | 141.00 | — | — | ||
| Supply of field IoT device or Mini loggers for signal aspect. Inspection: RITES. | — | — | — | 1,11,85,456.68 | |
| — | 5.00 | — | — | ||
| Supply of IoT device or BHMU for sensing 110 V DC IPS Battery Bank (Minimum 1No for Each IPS battery bank). Inspection: RITES. | — | — | — | 9,77,867.3 | |
| — | 17.00 | — | — | ||
| Supply of Microprocessor based interface for SSDAC/HASDAC/MSDAC to monitor up to 8 ports of DAC reset boxes in SM Room. Inspection: RITES. | — | — | — | 28,86,066.71 | |
| — | 1.00 | — | — | ||
| Supply of LC HMU. Inspection: Consignee. | — | — | — | 79,329.48 | |
| — | 101.00 | — | — | ||
| Supply of Point machine Vibration sensor. Inspection: RITES. | — | — | — | 11,43,107.9 | |
| — | 1.00 | — | — | ||
| Supply of station Gateway equipment. Note: Necessary Public IP and its recurring charges should be borne by the railway. Inspection: Consignee. | — | — | — | 2,05,352.14 | |
| — | 1.00 | — | — | ||
| Supply of Edge Computing device. Inspection: Consignee. | — | — | — | 1,89,561.03 | |
| — | 1.00 | — | — | ||
| Supply of networking interface (E1 Converter / Ethernet Converter) for Station gateway to network with Division HQ. Inspection: Consignee. | — | — | — | 43,270.63 | |
| — | 1.00 | — | — | ||
| Supply of voice modem at station gateway to connect field IoT device to the station gateway via copper cable. Inspection: Consignee. | — | — | — | 29,336.02 | |
| — | 340.00 | — | — | ||
| Supply of voice modem in location box to connect field IoT device to the station gateway via copper cable. Inspection RITES. | — | — | — | 62,33,903.4 | |
| — | 254.00 | — | — | ||
| Testing & commissioning of field IoT Devices or Mini loggers for point, Track. | — | — | — | 15,52,361.64 | |
| — | 142.00 | — | — | ||
| Testing & commissioning of field IoT Devices or Mini loggers for signal aspects & LC HMU. | — | — | — | 8,67,855.72 | |
| — | 5.00 | — | — | ||
| Testing & commissioning of IoT Devices or BHMU for IPS Battery Bank. | — | — | — | 1,52,791.75 | |
| — | 1.00 | — | — | ||
| Testing & Commissioning of station Gateway equipment system and Edge Computing Device at the station. | — | — | — | 30,558.35 | |
| — | 17.00 | — | — | ||
| — | — | — | 2,30,885.33 | ||
| & Commissioning monitor up to 8 pots of | : - Testing to | — | — | ||
| — | — | — | interface | ||
| — | 101.00 | — | — | ||
| Testing & Commissioning of Point machine Vibration sensor. | — | — | — | 2,28,621.58 | |
| — | 1.00 | — | — | ||
| Supply of maintenance monitoring system. Inspection Consignee. | — | — | — | 1,65,015.06 | |
| — | 400.00 | — | — | ||
| Supply of RDPM Software and it includes Configuration and mapping of gear wise signaling information in remote diagnostic software, testing and commissioning. Inspection: RITES. | — | — | — | 48,89,336 | |
| — | 5.00 | — | — | ||
| Supply of OFC integrated access device 1U height or 1.5 U height /19" rack mountable for LVCD /Digital axle counter purpose; optical module integrated in the unit supporting dual core OFC and one 100Mbps Ethernet port for surveillance/ smoke detector; optical distance support to be 20 kms; unit to support one E&M module supporting four 2W/4W (each port configurable) to support axle counter / UFSBI/Control phone/ EC/RTU/ and one TELNET/SNMP port; unit to support DC/AC power supply ; unit to support change over mechanism between quad and optical fiber for E&M option; one number cable to be provided along with unit for E&M ; FABIO/2CX/OFC/DC & Module 2W/4W four port : Make :TEAM ENGG/FABIO/WAVES or similar /TANSY. Inspection: RITES. | — | — | — | 12,98,863.95 | |
| — | 2.00 | — | — | ||
| Supply of portable Management Console for onsite programming. Model: DELL Inspiron 14 Laptop or similar (12th Generation Intel Core i7 or better, processor 4.4 Ghz or higher, RAM 8GB or higher, SSD 1TB, with inbuilt dual Graphic Card) or better as per specification. Inspection: Consignee. | — | — | — | 1,52,498.46 | |
| — | 42.00 | — | — | ||
| Supply, installation & commissioning of maintenance free earth suitable kit as per RDSO specification RDSO/SPN/197/2008 and Drg No. SDO/RDSO/E&B/002 dated 19.09.2008 or latest with latest amendments. Earthing kit consist of: 1. Earthing electrode of 17mm dia and 3 meter long-01 no. 2. MEEB (300mmX25mmX6MM) -01 no. 3. SEEB (150mmX25mmX6mm)-01 no. 4. Earth enhancing compound-30 Kg (minimum). This include provision of earth connection from MEEB to S&T equipment i.e. cable sheath, apparatus case, IPS, data logger, MSDAC, SSDAC etc. with PVC earth wire of size 16/25Sq.mm through copper lugs of suitable size. PVC wire shall be supplied by Railways. Note: At certain locations it may not be possible to achieve earth resistance of less than 1.0 ohm with one earth electrode/pit due to soil resistivity. In such case provision of loop earth consisting of more than one earth pit shall be done. For inter-connection of two earth pits copper tape of size 25x2 sq. mm shall be provided by contractor. The number of pits required shall be decided based upon the resistance achieved for the earth pit already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Inspection: RDSO for supply portion. | — | — | — | 11,57,346.54 | |
| — | 270.00 | — | — | ||
| Supply and installation of earth electrodes as per std. practice. The item includes digging of pit in earth, 3 Meter deep and fixing earth electrode pipe. Casting of cement concrete enclosures as per drawing No. (NR/S&T/CON/6.4/97). The soil treatment shall be done as per std. practice. The item includes provision of mild steel flat of size 35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument, cable sheath of power equipment, signal base, apparatus case, CT rack / relay racks, other equipment as per the instruction of Engr. at site & IRSEM. Earthing connection location to location shall be done through cable which shall be provided by Railway. Complete materials such as earth electrodes as per drawing No. (NR/S&T/CON/6.3/97), cement, wiring material, nut bolt for connection & mild steel flat of size 35mm x 6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection: RITES for supply portion. | — | — | — | 10,40,283 | |
| — | 12.00 | — | — | ||
| Hiring and operating multi utility vehicle (Maximum 3 vehicle in a month) of loading capacity one MT with sitting capacity of 4 to 6 persons, 4-stroke, 4-cylinder engine, factory-built metal body, cargo box type passenger cabin type or both (with 24 hours availability) including cost of fuel, lubricants, operating and maintenance including on kutcha/pucca road along the track. The contractor shall arrange road permit for vehicles for all the states of operation as per instructions of engineer incharge. Vehicle shall not be older than 3 years. The max KM utilization per month is 1200KM per vehicle. | — | — | — | 3,93,434.76 | |
| Vehicle Km | 12000.00 | — | — | ||
| Extra over item no.116 above for every additional KM or part thereof over 1200 KM per month. | — | — | — | 2,78,640 | |
| — | 10.00 | — | — | ||
| Supply, installation, commissioning of fault locator for short circuit detection in the fire alarm loop required as per UL listed solution & RDSO/SPN/217/2021 Ver 3.0 or latest. Spare cost also included & to be supplied as per RDSO para no.4.15. Inspection: RDSO for supply portion. | — | — | — | 57,631.5 | |
| — | 5.00 | — | — | ||
| Supply, installation, testing and commissioning of single channel laser or high-power LED based Aspiration detection unit (for AC room) with area covering 5000 sq.ft. with programmable 4 stage alarm generation and with 4 addressable modules along with required module and power supply, interfacing module etc. It should have auto cleaning facility in optical chamber, electronic discrimination of particle size, ultrasonic air flow sensing auto learn feature with TCP/IP network capability, the aspiration system shall also include external power supply unit with battery back-up. Approval-UL/LPCB/VDS listed and shall comply to specification No.RDSO/SPN/217/2021 ver-3 or latest. Spare cost also included & to be supplied as per RDSO para no.4.15. | — | — | — | 13,87,248.15 | |
| — | 94.00 | — | — | ||
| Supply, installation, commissioning Heat and Smoke Multi sensor detector with automatically adjusts sensitivity levels without the need for operator intervention or programming sensitivity increase with heat varying and floating sensitivity from 0.5 to 4% Ft and shall be plug in type facility and address through switch. The base should also be supplied as per RDSO/SPN/217/2017 Ver 3.0 or latest. Spare cost also included & to be supplied as per RDSO para no.4.15. Inspection: RDSO for supply portion. | — | — | — | 5,59,528.42 | |
| — | 5.00 | — | — | ||
| Supply, installation, commissioning of microprocessor based networkable analogue addressable UL listed and modular type of Fire alarm Control Panel with 2-loop expandable up to 4- loop with 80 character display with battery charger and battery, backup for 24 Hour normal operation and 15 Min alarm operation addressable power supply and alpha-numeric keypad for installation for the FAS panel and 1,000 event recording facility as per RDSO/SPN/217/2021, Ver 3.0 or latest with GSM module-01 no. for sending SMS to configured mobile number and relay module-02 no. for connecting to datalogger for remote monitoring. The panel should support sufficient devices of both detectors and modules in a single line. Spare cost also included & to be supplied as per RDSO para no.4.15. Inspection: RDSO for supply portion. | — | — | — | 28,28,078.15 | |
| — | 150.00 | — | — | ||
| Supply, installation, testing and commissioning of UL/LPCB/VDS listed CPVC pipe with suitable diameter as per requirements & pipe accessories for the Aspiration detection shall comply to RDSO/SPN/217/2021 Ver.3.0 or latest. Spare costs are also included & to be supplied as per RDSO Para no.4.15. Inspection: RDSO for supply portion. | — | — | — | 1,16,100 | |
| — | 80.00 | — | — | ||
| Supply, installation, commissioning of analogue type Linear Heat Sensing (LHS) cable which is self-restorable after the fire event as long as its temperature does not exceed specified resettable temperature limit of 120 degree Celsius it shall have an activation temperature of 70 degree Celsius as per RDSO/SPN/217/2021, Ver 3.0 or latest. Spare cost also included & to be supplied as per RDSO para no.4.15. Inspection: RDSO for supply portion. | — | — | — | 1,40,684 | |
| — | 1.00 | — | — | ||
| Supply, installation, commissioning of GUI software to monitor health of detector and other devices along with control panel. The software shall be accessible over TCP/IP. It shall also be able to indicate in the device whenever the detector or the device would require to be serviced as per RDSO/SPN/217/2021 Ver 3.0 or latest. Spare cost also included & to be supplied as per RDSO para no.4.15. Inspection: RDSO for supply portion. | — | — | — | 1,83,683.29 | |
| — | 5.00 | — | — | ||
| Supply, installation, commissioning of GSM interface module suitable to interface with the control panel as per RDSO/SPN/217/2021, Ver 3.0 or latest. Spare cost also included & to be supplied as per RDSO para no.4.15. Inspection: RDSO for supply portion. | — | — | — | 1,30,231.1 | |
| — | 10.00 | — | — | ||
| Supply, installation, commissioning of UL listed glass break manual call point as per RDSO/SPN/217/2021 Ver. 3.0 or latest. Spare cost also included & to be supplied as per RDSO para no.4.15. Inspection: RDSO for supply portion. | — | — | — | 57,115.3 | |
| — | 10.00 | — | — | ||
| Supply, installation, commissioning of audio-visual alarm unit as per RDSO/SPN/217/2021, Ver 3.0 or latest. Spare cost also included & to be supplied as per RDSO para no.4.15. Inspection: RDSO for supply portion. | — | — | — | 1,12,954.5 | |
| — | 10.00 | — | — | ||
| Supply, installation, commissioning of Linear Heat Sensing interface module as per RDSO/SPN/217/2021, Ver 3.0 or latest. Spare cost also included & to be supplied as per RDSO para no.4.15. Inspection: RDSO for supply portion. | — | — | — | 14,64,021.3 | |
| — | 10.00 | — | — | ||
| Supply, installation, commissioning of end of Line box for linear Heat Sensing cable as per RDSO/SPN/217/2021, Ver 3.0 or latest. Spare cost also included & to be supplied as per RDSO para no.4.15. Inspection: RDSO for supply portion. | — | — | — | 51,761.8 | |
| — | 600.00 | — | — | ||
| Supply, installation, commissioning of circuit integrity cable 2 core 1.5 Sq.mm as per RDSO/SPN/217/2021, Ver 3.0 or latest. Spare cost also included & to be supplied as per RDSO para no.4.15. Inspection: RDSO for supply portion. | — | — | — | 1,71,612 | |
| — | 15.00 | — | — | ||
| Supply of ISI marked Carbon di Oxide type (BC) fire extinguisher of 4.5 Kg capacity confirming to IS: 2878 from seamless cylinder confirming to IS: 7285 with IS marked control value conforming to IS: 3224 high pressure long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket etc. as required by site Engineer. Inspection: Consignee | — | — | — | 1,55,960.1 | |
| — | 30.00 | — | — | ||
| Dismantling and releasing single signal post which includes dismantling of signal fittings electrical and mechanical both wheel of sorts, GI pipe pullies, pully stakes wire run from cabin to signal posts etc. All dismantled material to be transported and stacked in the store of SSE/Sig/C/Store/LKO or DYCMM/SSB/LKO or any other stores of northern railway. | — | — | — | 46,629 | |
| — | 30.00 | — | — | ||
| Dismantling and releasing of Point equipment which includes all S&T fittings of electrical and mechanical, facing point lock/ hand plunger lock/ lock bar / holding bar/ EPD/ mechanical detector/ Pt. machine with all attachments. All dismantled material to be transported and stack in the store of DY.CMM/AMV/LKO store depot or SSE/Sig/C/Store/UTR/LKO or any other store of N.Rly as per consignee. Note:- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr. (1 Job= 1 Point) | — | — | — | 46,736.7 | |
| — | 140.00 | — | — | ||
| Dismantling and release of location boxes/apparatus case Jn boxes including of terminal board relay terminal, batteries, track feed chargers& other associated fitting installed therein complete with fittings all materials transported and deposited in the store of SSE/Sig/C/Store/UTR/LKO or DYCMM/SSB/LKO or any other stores of northern railway. | — | — | — | 1,24,374.6 | |
| — | 5.00 | — | — | ||
| Dismantling and releasing of S&T gears in ASM room, Battery room, relay room, equipment room, DG room (including DG sets). This includes all equipment and relays, relay rack, terminal board, SM Slide frame, panel batteries, battery chargers, angle iron, etc. All dismantled material to be transported and stack in the store of DY.CMM/AMV/LKO store depot or SSE/Sig/Store/TKJ or any other store of N.Rly as per consignee. Note:- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr. (1 Job= 1 Room). | — | — | — | 62,434.15 | |
| — | 8000.00 | — | — | ||
| Loading, leading and unloading of released/other materials from site to DyCMM/AMV store or SSE/Sig/C/UTR store. Transportation of signalling /Telecom material such as cable drum or other Railway Material etc., using Truck/MUV from Railway Store/any designated place to work site. Labour required for loading/unloading and transportation vehicle will be arranged by contractor. | — | — | — | 53,920 | |
| — | 50.00 | — | — | ||
| Earth work for excavation and refilling around location boxes and signals etc. where necessary including 50M lead and 1.5M lift. The lead is to be measured from center of gravity of location to the center of filling and lift from main ground level. The earth work should be well rammed including breaking of clods, leveling and dressing etc. as per instruction of Engineer at site. | — | — | — | 7,794 | |
| — | 35.00 | — | — | ||
| Concreting unscheduled items in concrete of 1:3:6 ratio in cement, coarse sand and aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement sand ratio. It also includes the excavation of earth as required at site and as per instruction of site in charge. The volume in cubic meters shall include the volume occupied by any CI foundation, trestle, MS angle or flat or GI pipe required to be embedded in the casting. Cement coarse sand and aggregate 25mm are to be supplied by the contractor. | — | — | — | 5,46,836.5 | |
| — | 1.00 | — | — | ||
| Cleaning, scrapping, painting & lettering of all newly installed & existing gears such as signals, point equipment, track circuit equipment with TC No. on rail, apparatus cases, JB, TLJB, point Roding, cranks, compensators etc. including gate equipment if existing in station section as per the provision of IRSEM. All paints (ISI marked) shall be approved by Railway Engineer and painting materials to be supplied by the contractor. This includes writing, and painting requirement of all indoor and outdoor gears along with marking of all circuit Nos. near terminal and terminal boards/rack in apparatus cases, Junction boxes, relay room, SMs room, writing of relay nomenclature, fuse Nos. and equipment nomenclature as per the approved plans and as per provision of IRSEM. (1 JOB = 1 Station). | — | — | — | 26,169.04 | |
| — | 1.00 | — | — | ||
| Supply and Installation of Demineralizer plant of capacity 65 Liters per hour approx. This includes all the pipe connections from water source to unit and also to collection unit as per instruction of site engineer. Inspection: Consignee for supply portion. | — | — | — | 40,325.7 | |
| — | 30.00 | — | — | ||
| Engaging mechanical excavators like JCB or other machineries for regarding and leveling the formation, dismantling any infringing structures, clearing and removing debris etc., with all lead and lifts etc., complete and as per the instruction of railway representative at site. | — | — | — | 33,493.2 | |
| — | 5.00 | — | — | ||
| Supply of ESM furniture of Godrej or similar make consisting of the following: 1. Executive revolving bearing series low back floating chair with normal arms cushioned Chair: 1No. 2. Executive Table size 72x36x30" with 3 drawers one side, lockers cabinet on other side: 1No. 3. Visitor chair seat & back cushion with high density Foam with plastic PVC handle capsule type Flat pipe duly Painted black: 3Nos. 4. One Steel Almirah of size 48"x30"x17" with lock and handle arrangement for record keeping at station. Inspection: Consignee. | — | — | — | 2,31,228.15 | |
| — | 12.00 | — | — | ||
| Supply of desk type magneto telephone suit IRS TC:36-97(Amndt.1) or latest with latest amendments. Inspection: Consignee | — | — | — | 67,177.08 | |
| — | 70.00 | — | — | ||
| Supply, Fixing & wiring of magneto telephones with all accessories including Standard battery box and 3 nos. of RR cells in the ASM office with crank handle locations/ K-points and interlocked L-xing gates as per instructions of the site Engr. All fixing materials including Standard battery box and 3 nos. Of RR cells to be supplied by the contractor. Inspection: Consignee for supply portion. | — | — | — | 4,01,262.4 | |
| — | 6.00 | — | — | ||
| Supply of 4-wire way DTMF base way station equipment as per spec. no. IRS-TC 60/207 or latest with power supply equipment as per spec. no. IRS-TC 72/97 with latest amendment with 12V/7AH battery and 4-wire control telephone as per spec. IRS:TC 38/97 with latest amendment. Inspection: Consignee | — | — | — | 53,219.16 | |
| — | 6.00 | — | — | ||
| Installation wiring & commissioning of 4 - wire way station eqpt. Item required for installation such as wires, wiring materials, connectors, battery rack runway, hardware etc. to be supplied by contractor. (Job = Per way stn. eqpt.). | — | — | — | 24,643.98 | |
| — | 10.00 | — | — | ||
| Supply and Installation of 20 pair DP box made of cast Aluminum within built locking system and waterproof should have double outlet with leading in brass nozzle. The main tag block plate is mounted on the inner aluminum chamber with brass terminal studded in back lite sheet. DP boxes & termination of cables as per specifications, drawing and stipulations of tender documents. This includes fixing of the same on 1" thick board of size as per directions of site engineer with ground nuts and bolts of suitable size and pipe fixed with clamps on pole /wall. All materials required for fixing & termination including salwood/hylum board and the hardware required for fixing will be supplied by contractor. Inspection: Consignee for supply portion. | — | — | — | 16,368.3 | |
| — | 1.00 | — | — | ||
| Supply of 25 Watt VHF synthesized trans receiver set, synthesized in frequency band 136 MHz to 174 MHz (full band), with DTMF microphone and cords, with GP antenna, 30 m of feeder cable and suitable BNC connectors, with 3m of power cord and 12V/13.5V 10Amp/15Amp power supply suitable for 25W VHF set, as per RDSO spec. RDSO/SPN/TC/107/2018, Rev. 0.0 Amendment 1 or latest. Make: Motorola /HYT/Kenwood or similar. Inspection: Consignee. | — | — | — | 23,843.08 | |
| — | 1.00 | — | — | ||
| Supply installation of Exide make 12 Volt, 120 AH single unit MF battery. Make Exide, Amaron or similar. Inspection: Consignee. | — | — | — | 14,902.56 | |
| — | 1.00 | — | — | ||
| Supply, fixing and wiring of surge protection device in attachment plug module with replaceable surge protection for coaxial signal, interfaces N-connector plug/socket installed as surge protection between antenna and 25 W VHF sets, make Phoenix Contact model CN-UB-280DC-SB- 2818148 or similar as per specifications. this includes mounting plate and reserve gas filled surge arrestor (one no.) with all required connectors/clamp for commissioning of SPD at site. Inspection: Consignee. | — | — | — | 7,057.24 | |
| — | 1.00 | — | — | ||
| Installation, testing and mounting of G.P. antenna on a GI pipe which is to be fitted on the roof of equipment room and lightning arrestors also to be mounted on a GI pipe. All fixing materials to be supplied by the tenderer and left over material to be returned to the railway store. N.B. G.P. Antenna, GI pipe (50 mm diameter) and lightning arrestor will be supplied by the railway. | — | — | — | 6,254.02 | |
| — | 150.00 | — | — | ||
| Supply of Medium class GI pipes 50 mm diameter (3.6 mm thickness) as per IS 1239 (Part 1): 2004 for use in ASM room and at any other location as decided by Site Engineer. It includes supply of all material required for fixing arrangement. At the ends of GI pipe, flexible/corrugated HDPE pipe will be provided by contractor to protect cables from sharp edges and sudden bends. Inspection: Consignee | — | — | — | 61,225.5 | |
| — | 1.00 | — | — | ||
| Installation of master VHF set 25 W on ASM table and wiring of the same with power supply wiring with 120AHVRLA battery. The 230V AC from the IPS to be extended to the power supply of the VHF and provision of power socket. This includes foundation (500x500x1000mm) and erection of 50mm GI pipe on roof top and fixing of Antenna with GI pipe (min 6 mtr.) and wiring from antenna to the VHF set with provision of guy wires for support of the GI pipe. All the materials cement, sand, GI pipe, guy wires, power wire with socket etc., (VHF set, antenna and 120AH VRLA battery to be supplied by Railway). | — | — | — | 7,403.02 | |
| — | 5.00 | — | — | ||
| Supply and installation of Digital Platform double side clock with GPS Synchronization as per RDSO specification no. RDSO/SPN/TC@47>47@2008 Rev.3.0 or latest (all fixing material shall be supplied by the contractor). Inspection-Consignee. | — | — | — | 1,85,164.45 | |
| — | 2.00 | — | — | ||
| Supply, installation and commissioning of Router [02 x 10/100/1000 LAN +08 x 02 Mbps [V.35] WAN +08 x 02 Mbps [G.703] Ports; 300 kbps] as per RDSO specification no.RDSO/ SPN/ TC/ 84/2008, Rev. 0.0 or latest. Inspection: Consignee for supply portion. | — | — | — | 4,41,454.72 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing, wiring & commissioning of Layer-2 managed Switch (24 ports 10/100/1000 BASET-ports, 4x 1G SFP+ ports) as per RDSO Specification No.RDSO/SPN/TC/65/2021 Version 6.0 or latest. Inspection: Consignee for supply portion. | — | — | — | 28,274.7 | |
| — | 2.00 | — | — | ||
| Supply & installation of pure Sine wave online 1KVA UPS with 2hr backup having SMF battery 4680 to be operated in input voltage of 160-260 V 50Hz AC input over voltage protection 155 AC, with manual bypass provision overload capacity of 125% of rated load under test for 60sec. Warranty of 2yrs for UPS and battery. Indications shall be mains ON, Battery charger ON, Battery on load, Battery low, Inverter ON, Inverter Trip, Overload, DC-ON. Minimum VAH:4680. Preferable make: Hykon, Hitachi, Numeric, Techser, Amararaja, V-Guard, APC, Emerson or similar/superior. Inspection: Consignee for Supply portion. | — | — | — | 46,071.48 | |
| — | 5.00 | — | — | ||
| Supply & installation of Annunciator (Multiway telephone exchange) 10 lines as per RDSO Drawing no. TCA-3352 (Adv.) or latest. Inspection: Consignee for supply portion. | — | — | — | 48,830.05 | |
| — | 20.00 | — | — | ||
| Final location survey of cable route, preparation of cable route plan, terminating plan, jointing schedule and tapping chart etc. as detailed in tender documents with particular reference to RDSO's code of practice "For installation and commissioning of OFC / 6 quad cable system" Approved drawings and documents shall be supplied in 6 hard copies in original of A4/A3 size along with 2 CD in AutoCAD of latest version. | — | — | — | 32,869.4 | |
| — | 30.00 | — | — | ||
| Supply & provision of straight through joints thermo-shrink jointing kit with the help of thermo-shrink jointing kit as per specifications, drawings and stipulations of tender documents and as per approved cable route plan at various locations for 06 Quad/04 Quad cable. Jointing kits to be supplied as per RDSO specification IRS:TC 77-2012 (Rev.-3) or latest amendments. Inspection: RDSO for supply portion. | — | — | — | 2,30,118.9 | |
| — | 8.00 | — | — | ||
| Supply of thermo-shrink jointing kit as per IRS TC 77/2012 Rev.3 with Amendment 1 & 2 latest amendments & provision of derivation isolation joint in quad cable & PIJF cable at LC gate, pump, houses, station cabins etc., using thermo-shrink jointing kit as per specifications, drawings and stipulations of tender documents. This includes all material required for making joints. Inspection: RDSO for supply portion. | — | — | — | 68,733.44 | |
| — | 25.00 | — | — | ||
| Supply of VF Tapping & Termination Transformers 2T/1120:470 Ohm as per IRS-TC- 22/76 with Amd-1 or latest amendments (round type). Inspection: Consignee | — | — | — | 60,629 | |
| — | 100.00 | — | — | ||
| Fixing of 1"/2" PVC channel/conduit pipe 1"/2" diameter on proper clamps and screws and indoor cable laying. | — | — | — | 1,321 | |
| — | 100.00 | — | — | ||
| Switch board cables per IRS Specification No IRS-TC-24/91 Make delton. (a) 5 pair/0.6 mm. (Inspection: Consignee). | — | — | — | 5,271 | |
| — | 100.00 | — | — | ||
| Switch board cables per IRS Specification No IRS-TC-24/91 Make delton. (b) 10 Pair/0.6mm. (Inspection: Consignee). | — | — | — | 9,940 | |
| — | 100.00 | — | — | ||
| Switch board cables per IRS Specification No IRS-TC-24/91 Make delton. (c) 20 pair/0.6 mm. (Inspection: Consignee). | — | — | — | 9,484 | |
| — | 14.00 | — | — | ||
| Supply and Provision of Emergency socket joints within 6 quad cable and PIJF cable with the help of Thermo-shrink jointing kit and 2T VF Transformer at locations decided by engineer at site. This includes all material required for jointing including Thermo-shrink jointing kit will be supplied by contractor except 2T VF Transformer (2T VF Transformer will be supplied by the Railway) as per IRS: RDSO/SPN/TC/56/2015 (Rev.1) with latest amendments. Inspection: RDSO for supply portion. | — | — | — | 65,445.94 | |
| — | 14.00 | — | — | ||
| Supply of 6 pin emergency socket as per IRS/TC/42/87(Amendment 1) or latest. (Inspection: Consignee). | — | — | — | 5,343.52 | |
| — | 14.00 | — | — | ||
| Supply of "Emergency socket Box of FRP material" as per RDSO specification no. RDSO / SPN / TC / 44/ 02 Ver.2.0, Amendment No.3 or latest. (Inspection: Consignee). | — | — | — | 16,386.86 | |
| — | 14.00 | — | — | ||
| Fabrication and fixing of E.C. socket assembly complete and erection of fabricated assembly at location indicated in the route chart and as directed by engineer in charge. E/Socket assembly box with socket to be wielded on the metal body of apparatus case track side as per instruction of site engineer. Termination of derivation cable inside emergency socket box. (Inspection: Consignee for supply portion). | — | — | — | 13,357.68 | |
| — | 5.00 | — | — | ||
| Supply and installation of Fiber management system 19" with all installation materials, splicing, termination and testing of 2*24 fiber of the cable i.e. 48 fibers with all connectors material as per the instruction of the site engineer. (Inspection: Consignee for supply portion). | — | — | — | 1,88,392.35 | |
| — | 1.00 | — | — | ||
| Supply of cable fault locator for underground cable as per model no. Telscout TS-90 (Test signal output1/2 Sine, Pulse width 5nsec to 2500nsec, Max Range:1500m, Filter cut-off Frequency:150kHz (High Pass Filter), Gain:0 to 63dB), Stanlay or similar branded make as per specification. Inspection: Consignee. | — | — | — | 3,52,571.17 | |
| — | 2.00 | — | — | ||
| Supply of Digital insulation Tester (Megger) 100 V, Motwani, Philips or equal to make. Inspection: Consignee | — | — | — | 13,935.72 | |
| — | 30.00 | — | — | ||
| Laying of HDPE duct in the trenches, including in HDD/Manual Boring and supply pulling of Nylon rope through is at different places as per direction of Engineer incharge/ site Engineer. It includes Supply of HDPE duct outer diameter 40mm & inner diameter 33mm as per TEC Gr No. G/CDS-08/02 Nov /2004 with latest amendment with end cap to be provided along with the drum at both ends. (RDSO specs No. RDSO/SPN/TC/45/2013 Rev.2.0). Inspection: RITES for supply portion. | — | — | — | 22,16,265.3 | |
| — | 60.00 | — | — | ||
| End plug for item no.174 above. Inspection: Consignee for supply portion. | — | — | — | 2,007.6 | |
| — | 60.00 | — | — | ||
| Cable sealing plug for item no.174 above. Inspection: Consignee for supply portion. | — | — | — | 2,537.4 | |
| — | 60.00 | — | — | ||
| Plastic Coupler-Slip Fit/Push fit type for item no.174 above. Inspection: Consignee for supply portion. | — | — | — | 5,176.2 | |
| — | 30.00 | — | — | ||
| Blowing/Drawing of OFC cable in the HDPE duct by mechanical system. | — | — | — | 3,49,106.4 | |
| — | 20.00 | — | — | ||
| Supply and installation of optical fiber cable joint enclosure as per TEC spec no. GR/OJC-02/01/ March 99 with latest amendment and splicing of optical fiber cables (24 fibers & testing). This includes provision of jointing kit (RCC/Prefabricated) as detailed in the technical specification and as advised by engineer at site. Inspection: Consignee for supply portion. | — | — | — | 3,80,805 | |
| — | 60.00 | — | — | ||
| Supply of OFC jumper (Patch card) 10mtr. long with FC/PC & SC or suitable connector at both end as per IRS:TC-81/2000 with latest amendment. Inspection: Consignee | — | — | — | 39,016.8 | |
| — | 60.00 | — | — | ||
| Supply of OFC jumper (Pigtail) 10mtr. long with FC/PC & SC or suitable connector at both end as per IRS:TC-81/2000 with latest amendment. Inspection: Consignee | — | — | — | 29,203.2 | |
| — | 5.00 | — | — | ||
| Installation & commissioning of OFC equipment for SCADA/axle counter per location. | — | — | — | 1,27,423.2 | |
| — | 1.00 | — | — | ||
| Supply & installation of managed SDH (STM-1 Add/Drop MUX and upgradable to STM- 4) fully wired for 2 x 63 MB and equipped for 21E1s and a virtual container (VC)-12 with STM-1 (L1.1) aggregate interface including power supply, order wire, ethernet card, sub-rack, in-built DDF, installation material and all other accessories, manuals and all other accessories, manuals etc. as per TEC specification GR SDH 04/02, March 02 or with latest amendment. The contractor will supply all other accessories as mentioned in the above said TEC specifications and system will have provision of different redundancy cards as per the TEC specifications. Note: It shall be possible to increase capacity from 21E1 to 63 E1s by adding/inserting tributary cards. This includes connecting all pig tails, optical patch cords etc. to the SDH equipment. This also includes connecting the SDH with all cards to the 48V bus including supply of wires and connectors. Termination of all E1s on DDF taking PVC cable over runway or a wall. At the terminal station, one port may be disabled if required as per instructions given by site engineer incharge. Inspection: (i) RDSO if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee subject to procurement from RDSO approved vendors id value of whole item in work less than 5 lakhs or as per extant policy. Inspection: Consignee for supply portion. | — | — | — | 2,17,397.14 | |
| — | 1.00 | — | — | ||
| Supply of 2MB programmable primary digital drop-insert multiplexer with conference facility as per technical specifications IRS:TC-68-2012 with latest amendments, with other stipulations of tender document, and with all common cards like processor card, power supply unit, remote control supervision etc. fitted in sub-rack fully wired for 30 channels complete & all other accessories, installation material manuals etc. The MUX shall be equipped for 16 E&M VF circuits, 4 data circuits of 64kbps, 6 hotline/subscriber interface circuits and one V.24 low data interface card for SCADA. The equipment shall be RDSO approved. Inspection: Consignee. | — | — | — | 1,28,200.94 | |
| — | 4.00 | — | — | ||
| Supply & testing of 2W/4W E&M VF Interface Cards (4ckts per card) for Puncom V Mux 100 shelf as per RDSO Spen no.IRS-TC-68/2012 compatible with above mentioned Mux. Inspection: Consignee. | — | — | — | 49,588.24 | |
| — | 2.00 | — | — | ||
| Supply & testing of Subscriber loop Interface Cards (minimum 4-circuit per card). (Inspection: Consignee). | — | — | — | 23,718.3 | |
| — | 1.00 | — | — | ||
| Supply & testing of Exchange loop interface cards (minimum 4-circuit per card). (Inspection: Consignee). | — | — | — | 12,416.32 | |
| — | 1.00 | — | — | ||
| Supply & testing of 2W hotline Interface Cards (minimum 4-circuit per card). (Inspection: Consignee). | — | — | — | 12,081.58 | |
| — | 1.00 | — | — | ||
| Supply & installation of 48VDC (2VDC, 200AH x 24) VRLA maintenance free battery complete with all fittings as per RDSO spec no.IRS-S-88/2004 or latest with wooden (sal) rack. Inspection: Consignee for supply portion. | — | — | — | 90,840.8 | |
| — | 1.00 | — | — | ||
| Supply & installation of SMPS based FCBC charger for telecom system rating 25Amp 230VAC/48VDC capacities with (N+1) configuration i.e. using 3 modules of 25Amp with automatic switching between the modules as per RDSO/SPN/TL/23/99 (Ver.III) or latest amendment. (Inspection: Consignee for supply portion). | — | — | — | 80,350.78 | |
| — | 1.00 | — | — | ||
| Supply. Installation and wiring of Lighting and surge protection device class B and class C for single phase as per TT network housed in a polycarbonate transparent box with IP 65 protection as per RDSO/SPN/144/2004. Inspection: Consignee for supply portion. | — | — | — | 48,093.24 | |
| — | 1.00 | — | — | ||
| Installation, wiring and commissioning of 2 MB programmable primary Drop/Insert mux with conference facility fully wired for 30 channels along with power supply and equipped for various types of interface cards as per site requirement. This includes shifting and installation of existing MUX. All materials required for work will be supplied by the contractor. | — | — | — | 13,305.24 | |
| — | 1.00 | — | — | ||
| Supply & Installation of 42U Rack, 42U*500W*450D, Front Glass Door with lock, 2 pairs of 19" Mounting Rails. Standard Accessories: - 1Ucable manager, Roof Mounted Fan Unit/90 CFM/230V AC, 6-way 5 Amp Power Distribution Unit, Mounting Hardware. Make: D-Link. Model: NWR- 42U- 5045-GR. (Inspection: Consignee for supply portion). | — | — | — | 34,994.62 | |
| — | 50.00 | — | — | ||
| Supply & laying of PVC conduit pipe 25mm dia with bend, clamps, fixtures and other required accessories. Inspection: Consignee for supply portion. | — | — | — | 1,310.5 | |
| — | 1.00 | — | — | ||
| Optical Power meter with Laser Source (1550/1310) as per G/OPM-02/02 Nov.1998 with latest amendments. Inspection: Consignee. | — | — | — | 1,94,726.37 | |
| — | 48.00 | — | — | ||
| Splicing of fibers OFC Cable and making Splice joint with contractor's own splicing machine and tools and consumables. | — | — | — | 16,608 | |
| — | 3.00 | — | — | ||
| Supply & Installation of 9U Rack, 9U*500W*450D, Front Glass Door with lock, 2 pairs of 19" Mounting Rails: Standard Accessories: -1Ucable manager, Roof Mounted Fan Unit/90 CFM/230V AC, 6-way 5 Amp Power Distribution Unit, Mounting Hardware. Make: D-Link. Model: NWR- 9U- 5045-GR. Inspection: Consignee for supply portion. | — | — | — | 36,118.02 | |
| — | 710.00 | — | — | ||
| Supply of CAT - 6 UTP Cable, CAT6 UTP 23/AWG Solid: 305Mt. Box. Make: D-Link, TP Link or Tenda. Inspection: Consignee. | — | — | — | 15,499.3 | |
| — | 8.00 | — | — | ||
| Supply and Installation of RJ-45 patch cord, seven feet long, of reputed make like Molex or similar, with 02 no. of RJ-45 connectors for every patch cord. Inspection by- Consignee 2mtr-10 5mtr:10 (Inspection: Consignee for supply portion). | — | — | — | 1,507.36 | |
| — | 2.00 | — | — | ||
| Supply of Power distribution & alarm panel (BTP) for V Mux 100 which is compatible with existing puncom mux. (This includes of 4U frame fitted with (a) Alarm processing card. (b) EMI filter & 04 no.MCB's, 6A, display alarms- major & minor & 01 Audio Alarm) Inspection: Consignee. | — | — | — | 20,409.66 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender Document
ATTACHMENT
TenderNotice.pdf
ATTACHMENT
VYNYard.pdf
ATTACHMENT
TenderDocument05-26final.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].