D.G. (E)
15n Nellie Sengupta Sarani Kolkata-700 087 West Bengal
RESTORATION OF THE DAMAGED ELECTRIC FURNACE NO. 3 WITH ALLIED WORKS AT COSSIPORE MAHASMASHAN.
2026_KMC_1002883_1
KMC/LTG/CRM/53/CRR/25-26
Open Tender
Electrical Work/ Equipment
8 days
COSSIPORE MAHASMASHAN
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹4,000
13 Mar 2026
10 Feb 2026
20 Feb 2026
10 Feb 2026
18 Feb 2026
10 Feb 2026
CLEANING AND REPAIRING OF FUEL DUCT PASSAGE: Removing the complete damaged R.S bricks and R.S slab of the (U.G) duct passage of the furnace chamber and thorough cleaning of the duct passage upto the start of brick build chimney by removing ash/carbon particles and relining the same with R.S Slabs & R.S bricks after mending good damages in the duct passages with insulation brick and red brick (1:4) with all necessary cementing masonry work
HEATING ELEMENT: Supply and fixing the Heating element (Heatco make) of capacity 4.5 K.W to be working in supply voltage of 240 V 50 Hz made from 80/20 Nicrome wire of 8 SWG in coiled coil from welded S.S stud on both ends. The coil should be inserted into the groove of existing coil brick after proper cleaning and the S.S Studs housed into the ceramic caller tube wrapped. With asbestos rope for tight fitting and sealing as heat proof extended S.S stud to be connected brass/ copper connector with complete connection in all respect of existing system.
DISMANTLING: Dismantling of all damage fire bricks from the furnace chamber such As 9 nos Roast Bricks. Ash collection bricks (M.K-16 to M.K-24) 9 Sets angle or shaped bricks M.K-88-18 nos. M.K-100-4nos., M.K-101-4 nos refractory / side bricks M.K-27-18nos. M.K-29-18 nos through clearing of as collection chamber, air ducts by removing the ash inside the furnished chamber for patch repairing purpose.
REMOVING OF STACK: Removing the broken bricks & all rubbishes to outside crematory/ dumping ground incl. loading, unloading, stacking & cost for transportation during patch repairing purpose .
PATCH WORK (RELINING): Relining the refractory shaped bricks, tiles, Angles bricks etc with good quality fire clay mortar by skilled labor (specially for cremation furnace) neat finishing and fitting for easy movement of the charging trolley over the roast bricks as per the direction of E.I.C of the dept. washing of the of the entire chamber with Sodium Siliminate clay should be necessary.Roast bricks-9 nos, Ash bricks-(M.K-24)-9nos Angle bricks-M.K-88-18nos, M.K-100-4 nos, M.K-101-4 nos.Side bricks-M.K-27-18nos, M.K-29nos.
PATCH WORK WITH BRICKS: Roast bricks
PATCH WORK WITH BRICKS: Ash bricks (M.K.-16 to M.K.-24)
PATCH WORK WITH BRICKS:Angle bricks M.K-88
PATCH WORK WITH BRICKS: Angle bricks M.K-100-4nos
PATCH WORK WITH BRICKS: Angle bricks M.K...101-4nos
PATCH WORK WITH BRICKS: Side bricks M.K-27
PATCH WORK WITH BRICKS: Side bricks M.K-29
PATCH WORK WITH BRICKS: Good quality fire clay mortar Washing of the entire chamber with Sodium Siliminate clay should be necessary.
ALTER(WITH BRICKS M.K.95) : Re-lining charges with M.K-95 bricks.
CLEANING AND REPAIRING OF FUEL DUCT PASSAGE: Supply & Fixing of R.S. slab after removing the same with necessary fire clay mortar.
HEATING ELEMENT: Supplying and fixing the terminal connector having drill holes for inserting S.S stud of 8.5 mm dia and connection point of existing copper wires of overall dimension 80mm long x25mm square shape.
Supply and fixing the tough ...V... belts of sizes(ECODRIVE make)-B98
POWER CONTACTORS: Supply and fixing the power contactor T.P 70A, L & T make (ML-4) having 240V, 50Hz, coil incl. 2 NO + 2 NC Aux contact block.
Sub Total
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.42 MB
form.pdf
Tender Documents • 0.86 MB
BOQ_2458156.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid