| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.6 CrAccepted-AOC MITTAL FARM LOHARU ROAD CHARKHI DADRI 127306 | CHARKI DADRI | HARYANA | 127306 | ₹7.6 Cr | 1 | Accepted-AOC Lowest |
| 2 | 2₹8.5 Cr+₹93.2 L (12.3%)Rejected-AOC | ₹8.5 Cr+₹93.2 L (12.3%) | 2 | Rejected-AOC Higher |
| 3 | Not Admitted-Fee/PreQual/Technical H NO 1100 SECTOR 3 124001 | ROHTAK | HARYANA | 124001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical BEHIND ANAJ MANDI SHASTRI NAGAR GALI NO 4 BHIWANI 127021 | BHIWANI | BHIWANI | HARYANA | 127021 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹7.0 Cr
EMD Value
₹13.9 L
Closing Date
25 Oct 2023, 10:00 amClosed
SHASHIKANT
EE PHE Division Charkhi Dadri
RENOVATION OF EXISTING STRUCTURES, CONSTRUCTION OF 1 B/STATIONS, LAYING THE DI PIPE LINES, PROVIDING FHTC
2023_HRY_321957_1
20234AA39FDA 3A60 43FD A9DC 1B42D5CC96BE555PUH
Open Tender
Civil Works
Works
360 days
CHARKHI
2 documents required · 2 mandatory
₹20,000
Yes
₹13.9 L
Yes
5 Dec 2023
19 Oct 2023
25 Oct 2023
19 Oct 2023
25 Oct 2023
19 Oct 2023
Amount
NS Item
Provision for light fitting at Pumping station complete in all respect
`RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked ` 4400 LPM x 25.00 m x 42.50 BHP
COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd. 35mm2 3core
HT. ALLUMINIUM CABLE: Supply erection testing of standard make XLPE 3 core HT / 11 KV grade ISI marked Stranded compact circular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, innersheath of PVC, galvanised steel flat strip armoured, and overall PVC sheathed cable conforming to is 7098 (part-2) 2011 with up to date amendments for making following connection a) from G.O switch to metering equipment . b) from metering equipment to transformer complete in all respect. Make: Indian Cables Ltd./ Polycab / RR Cables / CAPP / Finolex / Havells / Gloster / Universal / Fort Gloster Industries Ltd./ Indian Cable Co. / Asian Cables Corporation Ltd. 35 Sqmm size
LT CABLE ALLUMINIUM: Supply, erection, testing and commissioning of IS marked 3.5 core Cables, Solid Aluminum conductor up to 10sqmm and balance stranded conductor, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Aluminium wire for single core up to 70sqmm and balance Aluminium strip, Glavanised wire for cables up to2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip) extruded PVC type ST2 Outer sheathed, 650/1100V grade as per IS7098 (Part-1) 1988 with up to date amendments along with all accessories complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd. 70 Sqmm size
Dismantling old D.I. pipe rising main including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking joints, including stacking of pipes and lead at site within 50 metre lead as per direction of Engineer in-charge: Existing150 mm i/d DI pipe R/W pumping station to W/W
Panel Boards for Motors Supply, erection, testing and commissioning of wall mounted electrical L.T panel Board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm having following items complete in all respect as per approved NIT. For raw water pump sets for 4400 LPM x 25 Mtr. Head = 2 No. a) Main switch 100 Amp 1 No. (LandT, Siemens, ABB) b) Volt Mtr. 100x100mm range 0 to 500 volt 1 No. (AE/KAPPA?LandT) c) Amp.mtr. 100x100mm range 0 to 100 Amp. 1 No. (AE/KAPPA/LandT) d) CT 100/1 No. (AE/KAPPA/LandT) e) VSS 1 No. and ASS 1 No. each of approved make f) SPP 1 No. approved make g) Motor starter , star delta 1 No. for 4400 LPM x 25 Mtr. head motor (LandT, Siemens, ABB) h) Capacity of suitable capacity i) Indicating Lamp- j) Change over switch Amp
Operation and Maintenance for complete scope of work mentioned in the DNIT including existing Boosting Station (Disinfection material supplied by PHED) as per schedule-IV for a period of 5 year after 12 month during defect liability period and 03 Months trial run will be charged to the A/Mtc. estimate complete in all respect as per approved NIT. (i) Operation and Maintenance during defect liability period (Operation only) after 3 month trial run.
(ii) Operation and Maintenance during 1st year after defect liability period.
Operation and maintenance during 2nd year
Operation and maintenance during 3rd year
Operation and maintenance during 4th year
Operation and maintenance during 5th year
Bidder Name
Amount
RAM PHAL SINGH CONT(GSTN-NA)
ANAND KUMAR CONT(GSTN-NA)
RAM PHAL SINGH CONT
RAM PHAL SINGH CONT
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .