Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 863 JOSHI ROAD KAROL BAGH NEW DELHI DELHI 110005 | CENTRAL DELHI | DELHI | 110005 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | Admitted-Finance |
| 4 | Admitted-Finance 638 GROUND FLOOR WEST GURU ANGAD NAGAR LAXMI NAGAR LAXMI NAGAR EAST DELHI DELHI 110092 UDYAM DL 02 0031392 | EAST DELHI | DELHI | 110092 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
24 May 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE SDW V
Ring Road Andrews Ganj New Delhi 110049
N.I.T. No. 03 2022 23 Item No.8
2022_DJB_222441_8
N.I.T. No. 03 2022 23
Open Tender
Miscellaneous Works
Works
30 days
Ring Road Andrews Ganj New Delhi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Indian Bank
₹10,000
28 May 2022
18 May 2022
24 May 2022
18 May 2022
24 May 2022
18 May 2022
120 days
Specification of Battery Charger 30VDC/20 Amp 1 FCBC for 3.3 KV and 11 KV HT Panel : - Type: FCBC ; Make: max Power/Exide or DJB approved; Nominal Input voltage: 1 phase 230 V+ 10%; Frequency of input voltage: 50 Hz+5%; Nominal output voltage: 30 V DC; Output voltage variation: +0.05V/cell at rectifier O/P; Nominal output current: 20 A (10 A Battery + 10 A Load); DC O/P Voltage setting nominal voltage: 30 V (15 cells of 2V each @100 AH SMF VRLA Battery) make of battery: Exide/Amara raja/Amaron/Nuteck/DJB approved; Float@27C temp. (2.25V/Cell+/5%):33V(adjustable); Boost@27C temp:34.5 V adjustable; Ripple: < 5% RMS; Noise level:< 65 DB; Static Stability: INBUILT; Charging method: Auto boost & Float; Operational ambient temperature range: O C-55 C; Boost Charging Automatically & Manually: Both mode provided; Rectifier Block type: Thyristor diode full bridge half controlled with Al heat sink and cooling fan; DC filter type: LC; Earthling: from body; Protection degree IP-30; Cooling method: Natural & by fan; Structure Paint: Power coating; Steel structure: CRC; Steel thickness: 16 SWG as per IS; Paint shade: RAL-7035; AC Voltmeter Type/Size/Range/Accuracy/ class Make: AE/YOKINS/DJB Approved: Digital/0-300 V; O/P Voltmeter Type/Size/Range/Accuracy class Make: AE/YOKINS/DJB Approved: Digital 0-50 V; O/P Ammeter Type/Size/Range/Accuracy class Make: AE/YOKINS/DJB Approved: Digital/0-50 A; I/P Breaker MAKE: C&S/SCHNEIDER/DJB Approved: 16 A DB MCB – 1 No.; Battery breaker MAKE:C&S/SCHNEIDER/DJB Approved: 40 A DP MCB – 2 Nos.; Load breaker : 40 A DP MCB – 2 Nos. MAKE:C&S/SCHNEIDER/DJB Approved; Outgoing feeder MAKE:C&S/SCHNEIDER/DJB Approved: 16 A DP MCB (3 Nos.); Over load protection: Electronic; Short circuit protection: ELECTRONIC & MCB; O/P over voltage protection: Electronic; Rotary switch: 3 way 2 pole; Rectifier transformer VA rating:1200 VA; Rectifier transformer winding: Class F copper wire; Rectifier transformer: Limit of temperature rise over ambient of 50 C: Not more than 90 C; Filter choke rating: 20 A; Filter choke winding: Class F copper wire; Filter choke limit of temperature rise over ambient of 50 C: Not more than 90 C; Control & electronics wiring MAKE: HAVELLS/POLYCAB/DJB Approved: 0.5 sq.mm; AC Power wiring MAKE:HAVELLS/POLLYCAB/DJB Approved : 1.5 sq.mm; DC Power wiring MAKE: HAVELLS/POLYCAB/DJB Approved: 6.0 sq.mm; 10 Sqmm Single Core PVC Insulated Copper Flexible Cable for connection – 50 mtr; Blocking diode provided; Standards applicable: Relevant IS & IEC; Push buttons: PB1-Test PB2- Hooter accept; Indications: Mains on, Mains fail, charger on, charger fail, rectifier fuse fail, dc over load, earth fault control supply fail.
Installation, testing and commissioning of New Battery charger panel of size 1400 x 1100 x 500 mm of MS sheet of size 16SWG mounted on frame of MS angle of size 50 x 50 x 6 mm having height 450 mm at the site. This work includes termination of cable to BCP and HT Panel witjh new thimble and allied accessories as per site requirement and direction of engineer-in-charge.
MITTAL TRADING COMPANY
Gupta Brothers
SAI TRADING CORPORATION
SONI SALES and SERVICE
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .