| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹41.9 L+₹30,946 (0.74%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹42.3 L+₹68,636.40 (1.65%)Rejected-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹45.8 L+₹4.2 L (10.1%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹46.1 L+₹4.5 L (10.8%)Rejected-AOC 02 NERLE NERLE YEWALEWADI ROAD NERLE SANGLI MAHARASHTRA 415406 | SANGLI | MAHARASHTRA | 415406 | L5 | Rejected-AOC Rejected |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
17 May 2022, 6:00 pmClosed
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Repair / Replacement and maintenance of street lights / security lights / LT Electrical over headline / cables and LT panel / transformer / earthing / UPS system at ACCS KLP area and Airforce Station at KK Ranges under GE (N) Ahmednagar
2022_MES_517287_1
8618 / E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Ahmednagar
Class D Cat b(i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹90,000
Yes
8 Jun 2022
8 Apr 2022
19 May 2022
8 Apr 2022
17 May 2022
22 Apr 2022
Amount
Supply and Lay HDPE pipe 63 mm dia for laying of LT cables with all accessores etc complete all as specified and directed by Engineer-in-Charge.
Dismantling carefully the existing unserviceable LT overhead line ACSR any size from its position by necessary disconnecting of conductor and removing etc complete all as specified and directed by Engineer-in-Charge
Taking out existing unserviceable UG Cable by disconnecting of connections and LT UG Cable etc complete all as specified and directed by Engineer-in-Charge
(a) 10 Sqmm 2 Core
(b) 10 Sqmm 4 Core
(c ) 16 sqmm 4 Core
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size etc complete all as specified and directed by Engineer-in-Charge. :-
(a) 10 Sqmm 2 Core
(b) 10 Sqmm 4 Core
(c ) 16 sqmm 4 Core
Supply and replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension GI wire, twin core cable flat or circular with size 4 sqmm etc complete all as specified and directed by Engineer-in-Charge
All as per Item No 11 (here-in-before) but 10 sqmm 2 Core
All as per Item No 11 (here-in-before) but 16 sqmm 2 Core
Material and labour in replacement of 40mm dia GI Pipe light grade ISI Marked with all fittings laid in trenches , fixed to walls / poles with FI Clamps of size 40x5 mm etc complete all as specified and directed by Engineer-in-Charge
Material and labour in replacement of 50 mm dia GI Pipe light grade ISI Marked with all fittings laid in trenches , fixed to walls / poles with FI Clamps of size 40x5 mm etc complete all as specified and directed by Engineer-in-Charge
M&L for steel tubular poles, complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 Mtrs Long) including taking down existing pole etc complete all as specified and directed by Engineer-in-Charge
M & L for PCC(1:3:6) type C-2 using 40mm grade stone aggregates as foundation of pole and similar work etc complete all as specified and directed by Engineer-in-Charge
M & L for PCC(1:2:4) type C-2 using 40mm grade stone aggregates for coping and similar work etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing FRLS PVC insulated cables aluminium conductor, standard 4 Sqmm 2 Core etc complete all as specified and directed by Engineer-in-Charge
Dismantling and taking down carefully the defective Highmast light fittings from high mast pole by mechanically/ manually and removing the unseviceable light fitting from pole and supply and fixing led flood light 200 watt,lumen 20000 with 10 KV surge protection in built and reassembling the same pole , and refixing at its original location , including reconnections with suitable length and size of capper/Aluminium wire as per existing and testing / commissioning etc complete all as specified and directed by Engineer-in-Charge.
Lifting the Highmast pole 16 mtr height by crane from its own location with opening the nut boltt and washers , greasing the steel wire rope and fixing with pulley and reassembling and refixing at its orginal location, including reconnections and testing commissioning etc complete all as specified and directed by Engineer-in-Charge Note: (i) Rate for hire charges of Crane and labours is included in Quoted rates. (ii) Rate of sundry items like grease, cotton waste, nut , bolt and washers is included in quoted rates.
Supply only three pole contactor coil suitable for L&T contactor, 240V, 50 Hz cat part No CS94980/CS94105 or as per existing on site etc complete all as specified and directed by Engineer-in-Charge Make: L&T or equivlent makes mentioned in list of makes in Appendix `C'
Supply only three pole contactor L&T contactor,32/40 Amps,240V,50 Hz or as per existing on site etc complete all as specified and directed by Engineer-in-Charge. Make: L&T or equivlent makes mentioned in list of makes in Appendix `C'
Supply and fixing isolater 32/40 Amps,240 volt, three pole etc complete all as specified and directed by Engineer-in-Charge
M & L for painting of Street light poles (SWAN NECK) in two coats of aluminium paint and one coat of red oxide as primer including writing of pole nos etc complete all as specified and directed by Engineer-in-Charge
M & L for painting of Street light poles tubular type 9 mtr long in two coats of aluminium paint over one coat of red oxide as primer after preparing the surface including writing of pole nos etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of MCB TPN, 63 Amps 10 KA breaking / rupturing capacity capacity 415 volt , 50 HZ conforming to IS 60898-1 including necessary connection with suitable size of copper cable etc complete all as specified and directed by Engineer-in-Charge MAKE: CAT No DSMSCTNFO63 OF Standard or equvalent makes mentioned in list of makes in Appendix `C'
Supply and fix in replacement of LED post top lantern 40 Watt, with spun aluminium canopy & die cast aluminium spigot with opal PMMA acrylic diffuser pre wired with all accessories including making necessary connections and make it functional etc complete all as specified and directed by Engineer-in-Charge. Make : Crompton cat Part No- LPTO-40-CDL or equvalent makes mentioned in list of makes in Appendix `C'
Supply and fix in replacement of timer switch analog FM/1 quartz, 240volt, 50/60 Hz 16 amp/250VAC resistive of etc complete all as specified and directed by Engineer-in-Charge Make L&T of cat part No-J648B or equivalent makes mentioned list of makes in Appendix `C'
Supply, fix in replacement of Contactor 3 pole AC -1 40 Amps Main Pole Confugration 2 No 2 NC 415 volt fixing with Existing Box by suitable size of copper cable with suitable size of lugs etc complete all as specified and directed by Engineer-in-Charge. make L&T Cat Part No-SS90701 or equivlent makes mentioned in list of makes in Appendix `C'
S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of size 200 x 175 x100 mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size Mild Steel Bolts, Nuts & Washers, etc. including Taking down Unserviceable Pole Box of any description from any Height, etc complete all as specified and directed by Engineer-in-Charge
S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of size 310x210x120mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size Mild Steel Bolts, Nuts & Washers, etc. including Taking down Unserviceable Pole Box of any description from any Height, etc complete all as specified and directed by Engineer-in-Charge
M & L for replcement of Chain sprocket in Highmast Light etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of brass batten holder for fixing of gate light etc complete all as specified and directed by Engineer-in-Charge. Make Anchor or equivlent makes mentioned in list of makes in Appendix `C'
Supply and fixing in replacement of Triple pole and Neutral HRC type rewireable Swich fuse unit 63 Amp 415 volt AC 23 A 50 HZ conforming to IS 60947 1 & 3 fixing on Street light Pole with 32x4mm of MS Clamp and suitable size of nut, bolt and washers etc complete all as specified and directed by Engineer-in-Charge. Cat Part No-#DTPN063 of Indoasian or equivlent makes mentioned in list of makes in Appendix `C'
Supply and fixing with replacement of MCB SP 6 to 32 Amps with PVC Enclouser fixing with pole or wall for individual street light/ security light control with suitable size of clamp nut , bolt and washers etc complete all as specified and directed by Engineer-in-Charge Make : stanard, cat part No-DSMSCSPF006-032 or equivalent makes mentioned in list of makes in Appendix `C' Note: Rate of MS Clamp is included in Quoted Rates.
M&L for bracket for street light fitting made out from GI Pipe 50 mm Bore (dia), Light Grade, not exc. 1.20 Metre long, bend to required shape and fixing to Poles, etc. with and including Mild Steel Flat Iron Clamps 40x5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc. including Painting with One coat of Red Oxide Zinc Chrome Primer and Two coats of Aluminium Paint to all Mild Steel Works incuding taking down existing etc complete all as specified and directed by Engineer-in-Charge
Material and labour for street light control board / box of size 0.50 X 0.50 X 0.20 m made out of 1.60 mm thick MS sheet fixed / mounted on pole by means of 2 Nos of FT clamps of size 25 X 3 mm comprising the following enclousers and connecting with suitable size of copper cable etc complete all as specified and directed by Engineer-in-Charge:- a) MCB, TPN, 40 Amps, - 01 No MAKE: CAT No DSMSCTNF040 OF STANDARD OR equivalent in makes mentioned in list of makes in Appendix `C' b) Timer switch, eletronic, ET 100 operating on 110 / 240 / 415 Volts, 50 Hz MAKE: CAT No SE92006 OF L&T OR equivalent in makes mentioned in list of makes in Appendix `C' c) Contactor ML 2, 32 Amps,415 Volt - 01 No MAKE: CAT No SS90701 OF L&T OR equivalent in makes mentioned in list of makes in Appendix `C' d) All MCB,Contactor should be connected through HRC fuse
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply and fix in replacement of LED Street light Luminaries 70 watt, with inbuilt surge protection 10 KV, Lumans output 6000 with pressure die-cast aluminium housing with toughtened glass & IP 66 protection and impact resistance IK07 fixed with suitable size of GI Bracket of length 1.2 Mtr,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box to streeght light and 4 sqmm 2 core aluminium service cable pvc insulated 2.5 RM per fitting where over head line existing for connection of street light to over head conductor etc complete all as specified and directed by Engineer-in-Charge
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply and fix in replacement of LED Street light Luminaries 60 watt, with inbuilt surge protection 10 KV, Lumans output 6000 with pressure die-cast aluminium housing with toughtened glass & IP 66 protection and impact resistance IK07 fixed with suitable size of GI Bracket of length 1.2 Mtr,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box to streeght light and 4 sqmm 2 core aluminium service cable pvc insulated 2.5 RM per fitting where over head line existing for connection of street light to over head conductor etc complete all as specified and directed by Engineer-in-Charge
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply and fix in replacement of LED Street light Luminaries 45 watt, with inbuilt surge protection 10 KV, Lumans output 4500 with pressure die-cast aluminium housing with toughtened glass & IP 66 protection and impact resistance IK07 fixed with suitable size of GI Bracket of length 1.2 Mtr,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box to streeght light and 4 sqmm 2 core aluminium service cable pvc insulated 2.5 RM per fitting where over head line existing for connection of street light to over head conductor etc complete all as specified and directed by Engineer-in-Charge
Taking out Old existing security leight (HPSV/Tube light fitting) and Supply and fix in replacement of LED Street light Luminaries 36 watt, with inbuilt surge protection 10 KV, Lumans output 3500 with pressure die-cast aluminium housing with toughtened glass & IP 66 protection and impact resistance IK07 fixed with suitable size of GI Bracket of length 1.2 Mtr,Clamp,Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box to streeght light and 4 sqmm 2 core aluminium service cable pvc insulated 2.5 RM per fitting where over head line existing for connection of street light to over head conductor etc complete all as specified and directed by Engineer-in-Charge
Supply only in replacemet LED Drivers for 25 watt LED Fittings any type etc complete all as specified and directed by Engineer-in-Charge make as approved by GE
Supply only in replacemet LED surg protectors for 25 watt LED Fittings any type etc complete all as specified and directed by Engineer-in-Charge make as approved by GE
Supply only in replacemet LED Drivers for 30 watt LED Fittings any type etc complete all as specified and directed by Engineer-in-Charge make as approved by GE
Supply only in replacemet LED surg protectors for 30 watt LED Fittings any type etc complete all as specified and directed by Engineer-in-Charge make as approved by GE
Supply only in replacemet LED Drivers for 60/65 watt LED Fittings any type etc complete all as specified and directed by Engineer-in-Charge make as approved by GE
Supply only in replacemet LED surg protectors for 45/60 watt LED Fittings any type etc complete all as specified and directed by Engineer-in-Charge make as approved by GE
Supply only in replacemet LED Drivers for 70/75 watt LED Fittings any type etc complete all as specified and directed by Engineer-in-Charge make as approved by GE
Supply only in replacemet LED Drivers for 120 watt LED flood light Fittings any type etc complete all as specified and directed by Engineer-in-Charge make as approved by GE
Supply only in replacemet LED surg protectors for 120 watt LED Fittings any type etc complete all as specified and directed by Engineer-in-Charge make as approved by GE
Supply only in replacemet LED surg protectors for 200 watt LED Fittings any type etc complete all as specified and directed by Engineer-in-Charge make as approved by GE
Supply only in replacemet LED Drivers for 200 watt LED flood light Fittings any type etc complete all as specified and directed by Engineer-in-Charge make as approved by GE
Supply , fixing and testing Solar LED street light fitting complete having solar photo voltaic module 100 x 2 Wp system where 45 Watts LED lamp operates for stipulated time everyday without any human intervention work on auto electronic controller, including providing Battery 24 V, 120 Ah (Tubular plate Lead Acid battery) and electronic system with tamper proof MS box with corrosion resistance paint suitable for battery , bend pipe and camps suitable for mounting lamps fixtures complete including providing tubulor GI pole 20 feet designed to specifycally for Solar light fitting including PCC work , foundation, earth work including suitable size of cable etc complete all as specified and directed by Engineer-in-Charge Make-Havells, Modal No 45W Solar SLS,HSN Code.8541 or equivalent makes metioned in list of makes in appendix `C'
M & L for repairing of Highmast panel box by replacing of MCB TPN, Timer switch, Contactor and also repairing the Panel box by welding of hinges, replacement of Lock etc complete all as specified and directed by Engineer-in-Charge Note: (i) MCB TPN, Timer switch and Contactor shall be measured and paid separately. (ii) Rate for welding,Lock and keys , Painting in two coats of synthetic enamail and one coat of primer red oxide,
Supply and fix in replacement of MS Clamp 25x3mm with nut bolts and washers duely painted in two coats of aluminium paint and one coat of red oxide etc complete all as specified and directed by Engineer-in-Charge
Boring of holes under road/railway crossing, pavement, hardstanding by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4mpa working pressure without any damage to existing structure and making it good to match with the adjoining surfaces/structure etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of copper conductor XLPE insulated stranded , unarmoured ,extructed PVC type ST2 sheathed , 650/1100 volt graded as per IS 7098.of size 6 Sqmm 4 Core etc complete all as specified and directed by Engineer-in-Charge. Make Polycab cat part No- SISLV4X610693 or equivalent makes mentioned in list of makes in Appendix `C'
Supply and fix in replacement of steel wire rope Grade AISI 316, 7/19 with 6mm dia etc complete all as specified and directed by Engineer-in-Charge makes as approved by GE
Supply and fix in replacement of copper conductor PVC insulated stranded , unarmoured , 650/1100 volt graded as per IS 7098.of size 4 Sqmm 5 Core etc complete all as specified and directed by Engineer-in-Charge
Dismantling carefully the existing LT overhead line ACSR of any size from its position by necessary disconnecting of conductor and removing etc complete all as specified and directed by Engineer-in-Charge
Dismantling of unserviceable insulator of any type complete from its position and removing etc complete all as specified and directed by Engineer-in-Charge
Dismantling of unserviceable existing cross arms made from channels, angles and unserviceable FI clamps, nuts, bolts etc from OH line and removing etc complete all as specified and directed by Engineer-in-Charge
Dismantling of existing LT poles carefully of any size and type from its position carefully and removing from the site and necessary excavation and earth work in any type of strata, demolition of concrete, disconnecting of conductor etc complete all as specified and directed by Engineer-in-Charge
S&F stay assembly complete with accessories as shown in Electrical Plate No 1 of SSR 2009 (Part I) using stay rod 20mm dia, including clamps made out of 50 x 6mm MS flat, MS galvansied stay plate 300mmx 300mm x 6mm and galvanised thimble including insulator 90x140mm etc complete all as specified and directed by Engineer-in-Charge. (loop type insulator, stay clamps, excavation and concrete shall be measured and paid separately
M&L for prunning and removing of tree branches touching to electric over head lines wild growth around LT /HT over head lines and around pole and stay complete to make clear span of 2 Mtr of tree both side of the OH line with JCB, Cutter and all tools, plants etc complete all as specified and directed by Engineer-in-Charge Note : (i) Distance between pole to pole will be measured and paid. (ii) Contractor has to take upmost care to avoid damage to existing lines/structures if Any breakdown of line caused during punning shall be made good without any extra cost. (ii) Prunning of tree to be done twice a year (before & after rainy season) (iii) The contractor has to ensure the proper safety of the tradesmans to avoid any mishappening. If any mishappening occures the contractor will be solely responsible for it.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers etc welding bending cold or hot, drilling holes for bolts , in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one inishing coat of aluminium paint etc complete all as specified and directed by Engineer-in-Charge
M & L for replacement of Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade etc complete all as specified and directed by Engineer-in-Charge
M & L for replacement of shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers,insulator bolts, washers and nuts, 100mm height and 115mm dia including two nos of galvanised steel strap of size 31x5mm fitted with 14mm dia bolts and nuts etc complete all as specified and directed by Engineer-in-Charge
Labour for restringing of LT over head line consisting of 4/5/6 conductors retrive from ser item no-01 by dismantling taking down,unserviceable , damged ACSR conductor, repairing wherever required including cutting, re-joining and restringing in, with proper sag, binding to insulator with and including aluminium binding wire etc complete all as specified and directed by Engineer-in-Charge Note : (i) Only good and serviceable conductors are used, unserviceable conductors will be credited to contractor under schedule of credit. (ii) Rate of Transporting of conductor from one site to another site is included in quoted rate.
Supply, fixing and stringing ACSR (Weasel/ Ferret) for over head line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc complete all as specified and directed by Engineer-in-Charge (Note :- (a)jumper on cutout point/2 pole structer/4 pole structure shall be provided with PVC insulated sleeve. (b) Rate is inclusive of jumpers materials & tree branch cutting to make a safe distance from over head line.)
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil and added additional 1.5 m or part thereof in depth beyond the first 1.5 mtr etc complete all as specified and directed by Engineer-in-Charge
All as per ser item No 72 (here-in-before) but hard/ dense soil
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil etc complete all as specified and directed by Engineer-in-Charge
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point etc complete all as specified and directed by Engineer-in-Charge
Supply & lay HDPE pipe 75mm bore for laying of LT cables etc complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Supply & lay HDPE pipe 90 mm bore for laying of LT cables etc complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Supply & lay HDPE pipe 120 mm bore for laying of LT cables etc complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size etc complete all as specified and directed by Engineer-in-Charge:-
(a) 25 Sqmm 4 core,
(b) 35 Sqmm 31/2 core,
(c) 50 Sqmm 31/2 core,
(d) 70 Sqmm 31/2 core,
(e) 95 Sqmm 31/2 core,
(f) 120 Sqmm 31/2 core,
(g) 150 Sqmm 31/2 core,
(h) 240 Sqmm 31/2 core,
M/L for GI pipe light grade 100 mm dia Tubes, with all fitting and fixed complete to walls and ceilings or laid in floors complete for protection of cables etc complete all as specified and directed by Engineer-in-Charge
All as per Item No 88 (here-in-before) but 80 mm dia tubes
M & L for making good the damaged Tar Road by using additional stone metal, PCC etc complete all as specified and directed by Engineer-in-Charge
Demolition of u/s cement concrete in coppings etc complete all as specified and directed by Engineer-in-Charge
M & L for repair of LT Panel board of any size with replacing the unserviceable MCCB,MCB,switch fuse unit , change over ,Busbar,etc jointig cable with proper lugs ,nut , bolt and washers, cleaning the panel by using of CRC Soluation and repairing thhe panel door by using hinges and repairing the lock system, welding etc painting the LT Panel wit one coat of primer & two coat of synthetic enamel paint as approved or as per direction of Engr-in-Charge. Note:(i) MCCB,MCB,Switch fuse unit and change over switch measured and paid separately. (ii) Labour for MCCB, MCB, Switch fuse unit and change over switch measured and paid separately. (iii)Rate of new Busbar, lugs,CRC Solution,nut,bolt, painting etc and washers is included in quoted rate.
Supply and fixing in replacement of MCB TPN 63 Amps with breaking cap 16 KA and connecting etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of MCB DP, 40 Amps with 10 KA breaking / rupturing capacity including neccssary connection etc complete all as specified and directed by Engineer-in-Charge
All as per item No 94 here in above but 20 Amps
Supply and fix in for replacement rewirable switch fuse unit,of sheet metal , triple pole and neutral, 415 Volts grade, 63 Amps capcity including neccssary connection with suitable size of copper cable etc complete all as specified and directed by Engineer-in-Charge
All as Per item No 96 above but 100 Amps capacity.
Supply and fix in existing panel board for replacement of Switch Disconnector fuse (Cubical with HRC Fuse) Tripple pole and neutral 100 Amps ,415Volt,50HZ,AC 23A, conforms to IS:13947-3, fixed in existing Panel and connecting etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in in existing panel board for replacement of Switch Disconnector fuse (Cubical with HRC Fuse) Tripple pole and neutral 200 Amps ,415Volt,50HZ,AC 23A, conforming to IS:13947-3, fixed in existing Panel and connecting etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 400 Amps , with breaking capacity 36 KA , fixed type(HBC Series),adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt ,50 HZ conforming to IEC:60947-II/IS:13947-II and connecting etc complete all as specified and directed by Engineer-in-Charge
All as per item No 100 (here-in-before) but 200 Amps 25 KA breaking capacity. Make : CAT No Legrand Cat Part No DPX3 250, 420218 or equivalent makes mentioned in list of makes in Appendix `C'
All as per item No 100 (here-in-before) but 100 Amps 25 KA breaking capacity. Make : CAT No Legrand Cat Part No DPX3 250, 420215 or equivalent makes mentioned in list of makes in Appendix `C'
All as per item No 100 here in before but 63 Amps 25 KA breaking capacity. MAKE: CAT No Legrand Cat Part No DPX3 160, 420053 or equivalent makes mentioned in list of makes in Appendix `C'
Supply and fix in repairs/replacement of GI continous earth wire 4mm dia on cross arms of poles for guarding including binding and dismentling of old broken guarding etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs change over switch existing panel, wall or LT pole of any size and any type on load type, triple pole and neutral, 63 Amps, 415 V, 50 Hz front handle operated, including connecting and testing etc complete all as specified and directed by Engineer-in-Charge MAKE: CAT No CO10630OOOD of L&T or equivalent makes mentioned in list of makes in Appendix `C'
All as per Item No 105 (here-in-before) but off load type and side handle operated,Conforms IS/IEC 60947 including connecting and testing etc complete all as specified and directed by Engineer-in-Charge MAKE: CAT No OFFPOO63 of Indoasian or equivalent makes mentioned in list of makes in Appendix `C'
All per item No 105 (here-in-before) but , off load type, 100 Amps, front handle operated, MAKE: CAT No OFFPO100 of Indoasian or equivalent makes mentioned in list of makes in Appendix `C'
All as per item No 105 (here-in-before) but off load type, 200A side handle operated,
M & L for replacement of existing Amp meter (0-300Amp) along with CTs from existing LT Panel of any size etc complete all as specified and directed by Engineer-in-Charge
M & L for replacement of existing Volt meter 0 to 600 volt , digital type from existing LT Panel of any size etc complete all as specified and directed by Engineer-in-Charge, Make" L&T, CG
Material and labour for spray painting the LT Steel tubular pole,11/9 mtr long with two coats of synthetic enamel paint including prepartion of surfaces,Scraping the old paint and writing pole No in Black letter under yellow circle etc complete all as specified and directed by Engineer-in-Charge
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
Supply,installation,testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification,double door floor mounted outdoor type,as per IP-65 grade,made out of CRCA sheet 3.15 mm thick of outer body of suitable size with aluminium bus bar 1000 Amps,4 strip,(3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc with RYB indicater,internal wiring with suitable size of copper wire,panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger notice for 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs and glands Nuts & Bolts complete all as specifid and directed.(Eletronic wing line)
Incoming : - (i) MCCB 630 Amp, Adjustable Thermal & Adjustable Magnetic setting type with , 4 Pole,50KA - 01 No. (Ics=100% Icu) (ii) Volt meter 0 to 500 Volts, Square flush pattern, digital type – 01 No (iii) Amp meter square flush pattern 0 to 400 Amps digital type -01 No. (iv) Indicating lamp LED type one set in incoming phases. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (vi) Connection from MCCB to Busbar shall be of solid Aluminium conductor (vii) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable (viii) KWH meter CT operated as per suitable capacity of LT Panel Outgoing ways :- (i) MCCB 200 Amps ,Adjustable Thermal & Adjustable Magnetic setting type ,4 pole,36 KA-06 Nos(Ics = 100% of Icu) (ii) MCCB 100 Amps 02 Adjustable Thermal & Adjustable Magnetic setting type ,4 pole,36 KA-02 Nos(Ics = 100% of Icu)
Supply and spreading in electrical outdoor installation yard, stone aggregate of size 20 mm at 11KV substations / Near DP structures after through cleaning anti grass treatment etc complete all as specified and directed by Engineer-in-Charge
Supply and spreading in electrical outdoor installation yard, stone aggregate of size 40 mm at 11KV substations / Near DP structures after through cleaning, anti grass treatment etc complete all as specified and directed by Engineer-in-Charge
S&F in replacement of drop out fuse unit, explusion type for out door air break gang oprated switch, single pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts and washer etc synthetic bounded fuse tube complete with line capcity suitable for current carrying capacity upto 100 Amps all as directed including taking down old one etc complete all as specified and directed by Engineer-in-Charge
Repair / Overhauling of air break switch by replacing stationary and moving contacts, flexible copper chord, GI nuts, bolts etc including alingment for smooth functioning from ground level all as required at site and etc complete all as specified and directed by Engineer-in-Charge
Supply & fix LT line seperator 3/4 lines made of high quantity PVC material to provide 300 mm distance between phase to phase and neutal or as per sit reuirement etc complete all as specified and directed by Engineer-in-Charge Make: Supreme & Co Pvt Ltd Sanjay casting and Engineers, Mahalaxmi cable & Conductor or equivalent makes in list of makes in Appedix `C'
M & L for replacement of Galvanised iron strip 32 x6mm buried in ground
An amount of Rs 1,23,428.00 shall be deducted from BOQ on account of schedule of credit
Ms. S.K. ASSOCIATES
metro electrical services
AZAD SERVICES
RELIABLE ENTERPRISES
Mahindra Electric Stores
Maruti Abhiyantriki
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .