Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹14.7 L
EMD Value
₹29,346
Closing Date
26 Nov 2026, 3:00 pm4d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
EE Mechanical Jalandhar
Executive Engineer Mechanical Division Jalandhar
Providing of Traffic Signal System at Tanda Road Dosarka Distt. Hoshiarpur
2026_CEPW_179101_1
27
Open Tender
Electrical Works
Percentage
30 days
Hoshiarpur
Please refer Tender documents.
20 documents required · 20 mandatory
₹5,000
Yes
₹29,346
Yes
13 Nov 2026
13 Nov 2026
26 Nov 2026
13 Nov 2026
26 Nov 2026
13 Nov 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Design, Supply, testing & commissioning of 4G Modem & SIM Card based Data Receiving & Sending Communication Devices working on Serial/12C/Modbus TCP/ Ethernet TCP/IP protocols to be connected with separate City Signal Dashboard & Cloud Server System having following features and compatible for receving & sending data of Traffic Signal Controllers Systems at various junctions. The device should allow for the following tasks: i. Register & Login for the Application to communicate with the existing Controller Systems ii. Location of Traffic Signal Systems iii. Sending Programs and Data to the Controller Stations iv. Live display of Power Supply/Connectivity/Signal System UP or failure statusv. v. Live Display of Traffic Signal Lights working with 4g time lag vi. App notification trigger to various Officials for Signal Failures vii. Traffic Synchronisation Status, if any viii. Back-end admin panel for Maintenance Officials to pull out historical data of Signal Working | |||||
| 1.1 | ix. Fully customized Reporting module
x. Switching ON/OFF Traffic Signals
xi. Report for Special events at Traffic Signal System
xi. Notification to concerned Officers and Contractors for failure of Traffic Signal Supply. Multiple alerts shall be configurable The device should be compatible with existing Traffic Signal Controllers complete in all respects as approved by Engineer-in-charge at site. | 1 | Each | 47,700 | ₹47,700 |
| 2S/E of Intelligent Motherboard Controller compatible with GSM Model and facility for connectivity to control room, Vehicle Actuation Cameras and ATCS mode for Vehicle Management with Live SKIP Timer and Camera Integration. The detailed specifications of the controller are as below: -HARDWARE Memory: NOVRAM with built in battery battery backup System clock: Calendar clock (RTC) with minimum 5 years Battery back-up clock Programming Facility Through external Engineering Application WITH BLUETOOTH operation FEATURES Number of signals Minimum 16 signals group should be programmable as either vehicular or Pedestrian groups. Additional Programmable dummy groups as desirable. Number of stage: 16 stages Outputs The Motherboard should have Connector to connect further to the Sub Control Unit Vehicle Actuation: RS232/RS485/DI ports should be provided for communication with sensors and inbuilt software should be provided for Vehicle Actuation Facility so as to run the Traffic Signal in Vehicle Actuation Mode. The control system should have facility for working in Vehicle Actuation Mode. It should sense the inputs from various existing Traffic Sensors and adjust the Traffic Signals according to the intensity of traffic on all four/six roads of the Traffic Junction. | |||||
| 2.1 | The controller should be programmable so as to work in Vehicle Actuation with Cameras/Sensors etc at a particular time of the day/whole day/particular date etc. The controller should be integrated with Vehicle Detector cards, Vehicle Sensors cards etc. complete in all respects.
Area Traffic control compatibility Controller should have live Ethernet/internet port for connecting to the area traffic control centre. Live port should be provided and testing / demo should be done /displayed before commissioning of controller No hardware/software should be required to be provided up to controller at later stage when connection is required for area
controller.
ENVIRONMENTAL FEATURES
Operating voltage: 24VDC Temperature 0C to 70 C Relative Humidity Max 95% The controller shall be installed in the pedestal and also making connections to it with all the incoming and outgoing cables as per site requirement. complete in all respects as approved by Engineer-in-charge at site | 1 | Each | 1,23,550 | ₹1,23,550 |
| 3 | Design, Manufacture, Supply, Wiring & Commissioning of Traffic Light sub control unit with facility of Output Isolation Through solid state devices with zero cross output solid state switching isolated from control circuit by optical isolation in male female plug type single module. The solid state device should not be used for switching ON/OFF of more than 2 Nos. LED Lamps including shall be installed in the pedestal and also making connections to it with all the incoming and outgoing cables as per site requirement. The Sub Control unit shall be provided with Overload/over voltage protection and modular plug-in type system shall be provided for easy maintenance. The Unit shall also be provided with Indicators for Operator use complete in all respects with continuous input voltage current control & overload. complete in all respects as approved by Engineer-in-charge at site. | 1 | Each | 38,160 | ₹38,160 |
| 4 | Supply and erection of IP-65 Approved One Aspect signal Head LED Light Assembly of 300mm dia fabricated from polycarbonate materials die moulded Complete in all respects of nominal size 380 x 350mm complete in all respect with LED type traffic signals glasses. The visor shall be fabricated from UV Stabilised HDPE Materials of length min 254 mm depth and tilted 50 along the geometrix axis from the back side to front end as per IS 7537-1974 and the assemblies shall have provision for mounting of pole to permit directional adjustments. The lenses of red, amber or green colour shall be fabricated from 5mm dia LED's of light intensity of minimum 5000 mcd and the electronic switching circuit wired on printed circuit board of epoxy material with transparent covering glass of polycarbonate materials. LED Viewing Angle should be 23 degree with max. Forward Current as 20 mA & lamp shall be visible from 400m under normal atmospheric conditions (Conforming to IEC60529) a) Glass with a minimum of 190 LED's of Red/Amber colour, or b). Glass with a minimum of 66 LED's of Green colour in Arrow/Walking Man shape. complete in all respects as approved by Engineer-in-charge at site. | 60 | Each | 6,595 | ₹3,95,700 |
| 5 | Supply and erection of steel tubular pole 8.70mtr long and in two steps-bottom portion MS Pipe B class ISI mark 6mtr long 150mm dia and top portion MS pipe B class ISI mark gauge 3mtr long of 125mm dia with provision for the erection of bracket fabricated from 50mm dia M.S. pipe of A class upto 4mtr long, P type arm suitable for fixing of traffic lights and a 200mm dia round M.S. plate of 6mm thickness to be provided at the bottom of the pole. The pole will be erected 1.5mtr below ground level with 1:3:6 cement concrete mixture. The joining of the pole will be done so as to provide maximum supports to the joints including the cost of the all labour and material required for the job. The pole will also be provided with suitable reinforced plastic pole top for the safety of cables etc. The mounting arrangement of the lanterns should be made in such a way that signal heads can be adjusted as per required direction of the site complete in all respects as approved by Engineer-in-charge at site. | 4 | Each | 29,525 | ₹1,18,100 |
| 6 | Design & Supply of Smart Android based App for Traffic Signals to control all important parameters such as Programs, Timings, Vehicle Actuation parameters, Live Signal Working, Manual Control, Smart Icon etc shall be transferred and configurable from Smart Android APP The following parameters shall be programmable from anywhere in Jalandhar city:
Live Simulation of Traffic Signal actual working at site
Add, edit or delete data of Programs and sets in the Controller
Check working of Cameras
Check working of Downcounters
Mains Power Status
Battery Status - 24v
battery ststaus-12v
Logs of all important traffic data
complete in all respects as approved by Engineer-in-charge at site. | 1 | Each | 37,200 | ₹37,200 |
| 7 | Supply and erection of PVC under ground copper conductor 1.55q mm size armoured cable 14 core (loose in pipe) suitable for A.T.C. signals 660/1100 volts conforming to ISS 1554-1998 laid in existing pipe or in trench including cost of labour material required for the job. complete in all respects as approved by Engineer-in-charge at site. | 550 | Mtr | 495 | ₹2,72,250 |
| 8 | Supply and erection of PVC under ground copper conductor 1.55q mm size armoured cable 8 core (loose in pipe) sultable for A.T.C. signals 660/1100 volts conforming to ISS 1554-1998 laid in existing pipe or in trench including cost of labour material required for the job. complete in all respects as approved by Engineer-in-charge at site. | 175 | Mtr | 305 | ₹53,375 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.37 MB
Notice.pdf
Tender Documents • 1.35 MB
conditions.pdf
Additional Documents • 6.04 MB
DNIT_compressed.pdf
Additional Documents • 17.83 MB
BOQ_366242.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .