| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹19.2 L+₹1.3 L (7.07%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹26.1 L+₹8.2 L (45.8%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹27.0 L+₹9.1 L (51.1%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹27.2 L+₹9.3 L (51.8%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
| Sl No | Description | Qty | Unit | ANUSHKA BUILDERS L2 | M/S JAYCONSTRUCTION CO L9 | SKS Electricals L7 | Mahindra Electric Stores L4 | PURVA ELECTRICALS AND ENGINEERS L6 | SHREE VAIBHAV ELECTRICALS L8 | M/S kirpan Enterprises L1 | AMAN ENGINEERING AND ELECTIRICALS WORKS L3 | D H L ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down copper/aluminium point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking into credit (credit for above items shall be made as per condition laid down under schedule of credit seprately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed. | 762 | Point | 19.5 ₹14,859 | 50 ₹38,100 | 10 ₹7,620 Lowest | 40 ₹30,480 | 20 ₹15,240 | 25 ₹19,050 | 10 ₹7,620 Lowest | 12 ₹9,144 | 12 ₹9,144 |
| 2.00Material & Labour for point wiring using approved colour coding as per IS (Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area, single core, PVC insulated and sheathed FRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in and including medium grade,PVC casing & capping of suitable size on walls/roof/floor etc, ISI marked with suitable accessories, mild steel/ pressed steel sunken box of 1.2 mm thick and 60 mm deep ( with earth dolly ) duly painted with two coat of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide externally, covered with 3 mm thick plasticlaminated sheet cover for fixing of switches, sockets and fan regulator etc, including PVC insulated multistranded copper conductor 1.5 SQ mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer in charge for the following :- Make: Polycab /Finolex/ RR | ||||||||||||
| 2.01 | One fan/light /bell point controlled by one switch/bell push | 172 | Point | 390 ₹67,080 Lowest | 450 ₹77,400 | 750 ₹1,29,000 | 750 ₹1,29,000 | 720 ₹1,23,840 | 425 ₹73,100 | 450 ₹77,400 | 700 ₹1,20,400 | 620 ₹1,06,640 |
| 2.02 | One switch socket outlet 5 Amps on independent board | 80 | Point | 390 ₹31,200 Lowest | 450 ₹36,000 | 750 ₹60,000 | 750 ₹60,000 | 720 ₹57,600 | 450 ₹36,000 | 450 ₹36,000 | 710 ₹56,800 | 620 ₹49,600 |
| 2.03 | One socket outlet 5 Amps on the same board | 70 | Point | 250 ₹17,500 | 450 ₹31,500 | 210 ₹14,700 | 100 ₹7,000 Lowest | 200 ₹14,000 | 120 ₹8,400 | 145 ₹10,150 | 145 ₹10,150 | 410 ₹28,700 |
| 3.00 | All as per item No 2 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated but sheathed copper conductor FRLS cable 1100Volts grade and 2.5 sqmm as earth continuity conductor for one switch socket outlet 15 Amps on independent board complete all as specified and directed by Engineer in charge. | 60 | Point | 650 ₹39,000 | 750 ₹45,000 | 750 ₹45,000 | 950 ₹57,000 | 1,000 ₹60,000 | 550 ₹33,000 Lowest | 650 ₹39,000 | 850 ₹51,000 | 840 ₹50,400 |
| 4.00 | All as per item No 2 here-in-before but with 4.0 Sqmm PVC insulated multistranded copper conductor cable including 4.0 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 4 sqmm as earth continuity conductor for power socket on independent board complete all as specified and directed by Engineer in charge. | 35 | Point | 750 ₹26,250 | 950 ₹33,250 | 950 ₹33,250 | 1,150 ₹40,250 | 1,500 ₹52,500 | 650 ₹22,750 Lowest | 750 ₹26,250 | 1,540 ₹53,900 | 900 ₹31,500 |
| 5.00Material & Labour for point wiring using approved colour coding as per IS ( Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and unsheathed FRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in and including medium grade, PVC Conduit of suitable size on walls/roof/floor etc, ISI marked with suitable accessories , mild steel/ pressed steel sunken box of 1.2 mm thick and 60 mm deep ( with earth dolly ) duly painted with two coat of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide externally, covered with 3 mm thick plasticlaminated sheet cover for fixing of switches, sockets and fan regulator etc, including PVC insulated multistranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer in charge for the following :- Make - Polycab /Finolex/ RR | ||||||||||||
| 5.01 | One fan/light /bell point controlled by one switch/bell push | 90 | Point | 410 ₹36,900 | 450 ₹40,500 | 650 ₹58,500 | 850 ₹76,500 | 750 ₹67,500 | 400 ₹36,000 Lowest | 500 ₹45,000 | 940 ₹84,600 | 620 ₹55,800 |
| 5.02 | One switch socket outlet 5 Amps on independent board | 85 | Point | 410 ₹34,850 Lowest | 450 ₹38,250 | 650 ₹55,250 | 850 ₹72,250 | 750 ₹63,750 | 425 ₹36,125 | 500 ₹42,500 | 950 ₹80,750 | 620 ₹52,700 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
18 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
REPAIR MAINTENANCE OF INTERNAL ELECTRIC FIXTURE AND FITTINGS OF VARIOUS MD ACCN AND OTM ACCN OF UNITS AT AUNDH MIL STN UNDER GE MH AND RH KHADKI
2025_MES_720282_1
8703/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹60,000
10 Oct 2025
14 Jul 2025
20 Aug 2025
14 Jul 2025
18 Aug 2025
28 Jul 2025
14 Jul 2025 - 4 Aug 2025
Amount
Taking down copper/aluminium point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking into credit (credit for above items shall be made as per condition laid down under schedule of credit seprately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
Material & Labour for point wiring using approved colour coding as per IS (Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area, single core, PVC insulated and sheathed FRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in and including medium grade,PVC casing & capping of suitable size on walls/roof/floor etc, ISI marked with suitable accessories, mild steel/ pressed steel sunken box of 1.2 mm thick and 60 mm deep ( with earth dolly ) duly painted with two coat of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide externally, covered with 3 mm thick plasticlaminated sheet cover for fixing of switches, sockets and fan regulator etc, including PVC insulated multistranded copper conductor 1.5 SQ mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer in charge for the following :- Make: Polycab /Finolex/ RR
One fan/light /bell point controlled by one switch/bell push
One switch socket outlet 5 Amps on independent board
One socket outlet 5 Amps on the same board
All as per item No 2 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated but sheathed copper conductor FRLS cable 1100Volts grade and 2.5 sqmm as earth continuity conductor for one switch socket outlet 15 Amps on independent board complete all as specified and directed by Engineer in charge.
All as per item No 2 here-in-before but with 4.0 Sqmm PVC insulated multistranded copper conductor cable including 4.0 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 4 sqmm as earth continuity conductor for power socket on independent board complete all as specified and directed by Engineer in charge.
Material & Labour for point wiring using approved colour coding as per IS ( Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and unsheathed FRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in and including medium grade, PVC Conduit of suitable size on walls/roof/floor etc, ISI marked with suitable accessories , mild steel/ pressed steel sunken box of 1.2 mm thick and 60 mm deep ( with earth dolly ) duly painted with two coat of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide externally, covered with 3 mm thick plasticlaminated sheet cover for fixing of switches, sockets and fan regulator etc, including PVC insulated multistranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer in charge for the following :- Make - Polycab /Finolex/ RR
One fan/light /bell point controlled by one switch/bell push
One switch socket outlet 5 Amps on independent board
One socket outlet 5 Amps on the same board
All as per item No 5 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 2.5 sqmm as earth continuity conductor for one switch socket outlet 15 Amps on independent board through medium PVC conduit complete all as specified and directed by Engineer in charge.
All as per item No 5 here-in-before but with 4.0 Sqmm PVC insulated multistranded copper conductor cable including 4.0 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 4.0 sqmm as earth continuity conductor for power socket on independent board through medium PVC conduit complete all as specified and directed by Engineer in charge.
Material & Labour in repair sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into and including PVC cassing capping of suitable size including 4.0 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size complete all as specified and directed by Engineer in charge. Note: Two single core cable, earth wire and PVC conduit shall be measured as one length.
All as per item no 08 above but of 6 Sqmm.
Supply and fix in repair ceiling rose surface bakelite with three terminals type in complete all as specified and directed.
Supply and fix in repairs switch piano type one way 6 Amps flush type , 240volt AC complete all as specified and directed.
Supply and fix in repairs socket outlet 2 in1,3 pin 5 Amps complete all as specified and directed.
Supply and fix in repairs switch socket combination(SSC) 2 in 1, 3 pin, 5 Amps flush type ,240volt AC complete all as specified and directed.
Supply and fix in repairs switch piano type 16 Amps flush type ,240volt AC complete all as specified and directed.
Supply and fix in repairs socket outlet 2 in 1, 3/ 5 pin 16 Amps flush type complete all as specified and directed.
Supply and fix in repairs switch socket combination(SSC) 2 in 1, 3/5 pin, 16 Amps flush type , 240volt AC complete all as specified and directed.
Supply and fix in repairs Bell push, flush type, 6 Amp flush type ,240volt AC complete all as specified and directed.
Supply and fix in repairs switch piano type two way 6 Amps flush type , 240volt AC complete all as specified and directed.
Supply and fix in repairs Bell push, Modular type, 6 Amp flush type , 240volt AC complete all as specified and directed.
Supply and fix in repair modular switch 1 way 6A 1 module complete all as specified and directed.
Supply and fix in repair modular switch 2 way 6A 1 module complete all as specified and directed.
Supply and fix in repair modular socket 6A 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repair modular socket 6A /16A 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repair modular fan regulator, 120 watt - 2 module complete all as specified and directed.
Supply & fix in repair stepped type electronic fan regulator 120 watt, 240 olt flush type on the existing phenolic laminated sheet complete all as specified and directed
Supply and fix in repair electric bell Ding Dong, AC 230 volts complete all as specified and directed.
Supply and fix in repair Modular white cover plate with frame of following size complete all as specified and directed.
1 module
2 module
3 module
4 module
6 module
8 module
Supply and fixing in repair RCCB 63 A, four pole, 30 mA complete all as specified and directed. Make : Hager/L & T/Standard
Supply and fix industrial wall mounted plug socket suitable for IP 44 degree of protection of 32Amps rating 2P+E complete all as specified and directed. Make: L&T/Indoasian/Legrand/C&S
Supply & fix sheet metal enclosures for double door distribution board factory made duly painted of following capacity with 200 amps rated bus bar, suitable for fixing MCB /Isolators complete all as specified and directed Make : L & T/legrand/Havells
12 way SPN , 240V
8 way SPN 240V
4 way TPN DB Vertical type, MCCB as incomer 415 Volt
8 way TPN DB Vertical type, MCCB as incomer 415 Volt
Supply & fix MCCB 125 Amps, 4 pole, breaking capacity 16 KA, 415 V adjustable type complete all as specified and directed of capacity. Make: L &T /Legrand/Indoasian/standard.
All as per item no 31 above but of capacity 100 Amps.
Supply and fixing miniature circuit breaker (MCB) of following current carrying capacity, in the MCB DB complete with connection testing and commissioning. Make - L &T /Legrand/Havells
SP 5/6 to 32 AMP, 240V, 10 KA 'B' curve
SP 40 AMP, 240V, 10 KA 'B' curve
SPN 32 Amps, 240V, 10 KA 'C' curve
SPN 40 Amps , 240V, 10 KA 'C' curve
TPN 63Amps, 240V, 10 KA 'B' curve
Taking down old unserviceable fitting and Supply & fix wall mounted extruded aluminium housing high quality indoor batten of following capacity colour temperature 6500 K (4' long) lumen 2000 -3000, PF> 0.9, THD less 15% diffused connecting with three core flexible copper wire from connector to ceiling rose/angle holder as per existing site requirement complete all as specified and directed by Engineer in charge. Make : Havells/wipro/Halonix Note :- The rates are inclusive of cost of square box-02 nos including suitable size of clamps and screws etc.
LED tubelight fitting of 20 watt/22 watt, 4 Ft long
LED tubelight fitting of 10watt, 2 Ft long
Taking down old unserviceable Tube light fitting of any type and supply & fix wall/ceiling mounted Inverter LED tube light fitting 4' feets long with opal diffuser and having aluminium body. Energy efficient high quality invertor batten should have Lithium ion battery of 3.7V, 19 WH having inbuilt battery backup upto 2Hrs with high power brightness having BIS certification, LED fitting should be LM 80 certified with system efficacy greater than 100 lumens/watt, including LED tube 20/22 watt having colour temperature 6500 K , PF> 0.95, THD less 10%, with IP20 protection having open and short circuit protection, having input voltage range 90V to 300V connecting with three core flexible copper wire from connector to ceiling rose/angle holder as per existing site requirement complete all as specified and directed by Engineer in charge. Make : Havells/Jaquar/Halonix/Crompton . Note :- The rates are inclusive of cost of square box-02 nos including suitable size of clamps and screws etc.
Taking down old unserviceable fitting and Supply & fix Recess mounting LED flat panel light fitting of following wattage and size with efficient LEDs lumen 2000 to 3000, PF> 0.9, THD less 15% complete all as specified and directed. Make : Havells/wipro/Halonix
36 watt, 600mm x 600 mm size
18/20 watt, (1x1 )ft
Circular in size 18/20 watt not less then 6 '' dia
Taking down old unserviceable fitting and Supply & fix wall mounted high quality indoor wall bracket light cylinderical/oval shape aesthetically designed fitting with B22D lamp holder and 12 Watt bulb temp range 4000k to 6500 K as per site requirement connecting with three core flexible copper wire as directed by Engineer in charge. Make : Halonix /Havells/wipro/Benlo
Taking down old unserviceable MH bay light and supply & fix high effiicient suspended type 150 watt,230v, lumen 2000 to 3000, PF> 0.9, THD less 10% LED bay light of die cast aluminium housing with lens embedded PC cover IP 66 with efficancy not less then 120 lm/W, as per IS -10322 , high voltage cut off,open and short circuit protection including constant voltage and current LED driver complete all as specified and directed Note: Making arrangement for T & P to fixing of bay light is incluidng quoted rate. Make : Havells/wipro/Halonix
Taking down old unserviceable Bldg security light and supply & fix high efficent LED building security light 30 watt, 230 V, lumen 2000 to 3000, PF> 0.9, THD less 10%, made of pressutre cast aluminuim housing with high power LEDs, lens and toughned glass IP 66 protection connecting with three core flexible copper wire from connector to ceiling rose complete all as specified and directed Make :- Halonix/Bajaj/Havells.
Material & Labour in repair for unserviceable LED driver suitable for 36/40 watt LED panel light fitting (2 x 2) feets size on site complete all as specified and directed by Engineer in charge.
Supply & fix in repair bracket for mounting building security light made out of 40 mm dia Light Grade GI pipe bend in angle with holding MS clamps two nos each bracket of size 25x3 mm including screw etc for fixing complete all as specified and directed by Engineer in charge
Material & Labour in repair for earthing with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to 4.0 mm dia galvanized earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 (20 mm graded stone aggregate) RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution board complete all as specified and directed. Note: Rate for achieving required depth by compressor machine if required is deemed to be included in item unit rate.
Material & Labour in repairs / re-fixing on exiting or new location storage type electric water heater (geyser) of storage capacity 25/35/50 ltrs of any make comprising of the following works mentioned here under againt Ser Nos (a) to (f) at different locations:- (a) Inspection, taking down, opening ( dismantling ) descaling, brushing, cleaning of storage tank (b) Examine water tightness of storage tank after cleaning. (c) Carry out operation of all stop cocks, pressure reducing valves etc. to ensures free movement of the working parts. (d) Supply & fix Replacement of the rubber / PVC gasket to ensure water tightness. (e) Checking of safety valve (f) Testing of geysers after repairs.
Supply & fix in repairs thermal cutout ISI marked temp range 50 to 80/90 degree as required at site for geyser of capacity 25/35/50 Ltr of any make complete all as specified and directed by Engineer in charge
Supply & fix in repairs safety valve/high pressure valve ISI marked as per site requirement complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repairs heating element of following rating as required at site including rubber washers complete all as specified and directed by Engineer in charge.
1/1.5 KW, 240 volt
02 KW , 240 volt
Supply & fix in repairs PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 cm long for cold water connection complete all as specified and directed by Engineer in charge
Supply & fixing in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 CM long for hot water connection complete all as specified and directed by Engineer-in-charge.
Supply & fixing in repairs, non return valve 15 mm dia of brass, ISI marked complete all as specified and directed by Engineer-in-charge.
Supply & fix stop valve, cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm bore complete all as specified and directed by Engineer in charge
Material & Labour for repairing and replacement of following sizes unserviceable copper container of capacity 25/50 Ltrs of solar water heater of any type after completion of work testing the heater complete all as specified and directed by Engineer in charge
Copper container 50/100 ltr
Copper container capacity 25 Ltrs of water heater (geyser)
Taking down old unserviceable Ceiling /Exhaust/Air circulator fans of any type from any height and Material & Labour for rewinding of Ceiling Fan, Exhaust Fan and Air circulator of any type/make by split opening the fan carrying cutting the burnt winding and cleaning the slots and rewinding with super enamelled copper winding wire appropriate gauge including connection, capacitor base and testing complete all as specified and directed by Engineer in charge for following:-. Note: Bearing, fan canopy, capacitor, down rod etc will be measured and paid separately under relevant item of schedule.
Ceiling fan of 1200/1400 mm sweep
Exhaust Fan of sweep 275 to 300 mm
Exhaust Fan of sweep 350 to 450 mm
Air circulator of sweep 350 to 450 mm
Supply only ball bearing (DE/NDE) to match the existing make suitable for 1200/1400 mm sweep ceiling fan including greasing complete all as specified and directed by Engineer in charge. Make: SKF/NBC
Supply only ball bearing suitable for 275 to 450 mm exhaust fan complete all as specified and directed Make : SKF/NBC
Supply only fan capacitor of following capacity complete all as specified and directed
capacitor 2.5 mfd
capacitor 4 mfd
Supply only, rubber yoke, MS clamps, bolts nuts with split pin suitable for ceiling fan 1200 /1400 mm sweep complete all as specified and directed by Engineer in charge.
Supply only gunmetal bush of suitable size for ceiling fan 1200 /1400 mm sweep complete all as specifed and directed by Engineer in charge.
Supply only fan down rod of following length with white enamel painted with both side hole for hanging fan of sweep 1200/1400mm complete all as specified and directed by Engineer in charge
1 ft long
2 ft long
Supply only stator for ceiling fan of 1200/1400 mm sweep with silicon coating, anti rust coating, size and slot as per sample, feasible to fix in exisiting rotor size complete all as specified and directed
Supply only rotor for ceiling fan of 1200/1400 mm sweep with silicon coating, anti rust coating, size and slot as per sample, feasible to fix in exisiting stator size complete all as specified and directed
Supply only fan canopy set off white /white coloured as per colour of ceiling fan of sweep1200/1400mm complete all as specified and directed
Supply and replace hylum sheet 3 mm thick for Junction boxes, circuit boxes for various size and refixing the existing switches, sockets, regulators cut in to requied sizes including fixing with new cadmium plated screws and cup washers complete all as specified and directed.
Material & Labour for replacement of PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of following size make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engineer in charge.
100 x 100 mm and 50 mm deep
200 x 150 x 50 mm deep
250 x 200 x 50 mm deep
150 x 150x 50 mm deep
Decarbonizing of indoor MCB DB's / Meter box panel and distribution panel of bldgs by dismantling the old MCCB's, old Bus bars , cable connections, old Amps meter and old voltmeter and cleaning the panel with ctc solvent, and removing the old/burnt control wiring, replacing the old/burnt bus bar of any size if any and fixing properly the hanging/loose front and rear opening doors of the panels, by welding of hinges including welding of broken MS sheet using extra sheets of required size also replacing burnt thimbles with new existing size thimbles, indicator lamps, including powder coating painting of panel with suitable 'U' type gasket to make it dust and vermin proof, providing fancy locks incluidng dismantling the existing connected cables and re-connecting the same cables complete all as specified and directed by Engr -in- charge.
ANUSHKA BUILDERS (BID ID -3379877)
AMAN ENGINEERING AND ELECTIRICALS WORKS (BID ID -3390018)
Mahindra Electric Stores (BID ID -3390161)
D H L ENTERPRISES (BID ID -3389843)
PURVA ELECTRICALS AND ENGINEERS (BID ID -3390177)
SKS Electricals (BID ID -3387907)
SHREE VAIBHAV ELECTRICALS (BID ID -3397876)
M/S JAYCONSTRUCTION CO (BID ID -3382669)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .