| 1 | L1₹35.8 LAccepted-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹43.2 L+₹6.3 L (17.0%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹44.6 L+₹7.7 L (20.8%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 |
| Sl No | Description | Qty | Unit | metro electrical services L1 | United Enterprises L3 | SONA LAKSHMI ASSOCIATE L2 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down old unserviceable street light fittings /high way light /flood light/Watch tower light ) of any type and capacity up to 15 mtr heights and deposited to MES store yard for further disposal. | 230 | Each job | 5 ₹1,150 Lowest | 60 ₹13,800 | 50 ₹11,500 |
| 2.00 | Fixing only of street light , flood light, high bay light, high mast light, Focus light or any type of light to be fix on wall /pole/ hanger etc with the help of suitable size of nut bolt washer etc including all electrical connection connection as required at site ( Note - Material /store will be issued under schedule be ) | 100 | Each | 80 ₹8,000 | 110 ₹11,000 | 50 ₹5,000 Lowest |
| 3.00 | Supply, Installation, Testing and commissioning LED street light fittings 70 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No CRP-421-70-57-SL-LM-NSG with 5 years of warranty or equivalent in Havells/Phillips.complete all as specified and directed by Engineer- in-charge.. | 30 | Each | 1,650 ₹49,500 Lowest | 4,200 ₹1,26,000 | 3,000 ₹90,000 |
| 4.00 | Supply, Installation, Testing and commissioning LED street light fittings 60 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No CRP-421-60-57-SL-LM-NSG with 5 years of warranty or equivalent in Havells/Phillips. complete all as specified and directed by Engineer- in-charge.. | 50 | Each | 2,200 ₹1,10,000 Lowest | 3,900 ₹1,95,000 | 2,900 ₹1,45,000 |
| 5.00 | Supply, Installation, Testing and commissioning LED street light fittings 25 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No TRP-415-25-57-SL-LM-NBK with 2 years of warranty or equivalent in Havells/Phillips. complete all as specified and directed by Engineer- in-charge. | 50 | Each | 1,300 ₹65,000 Lowest | 1,850 ₹92,500 | 1,500 ₹75,000 |
| 6.00 | Supply & Fix in repair PVC perplex cover glove type with Base plate /holder not less than 8 inch dia suitable for Post top lantern including one nos 7/9 watt LED lamp complete all as specified and directed by Engineer- in-charge.Make - Bajaj / Surya/*havells. | 25 | Each | 500 ₹12,500 | 450 ₹11,250 Lowest | 600 ₹15,000 |
| 7.00 | Repairs to High mast light 15/30 Mtr high, by taking down the luminaires mounting frame mechanically and replacing the unserviceable items (paid separately) including lifting the superstructure after repairs and testing complete all as specified and as directed by Engr-in- Charge.. | 5 | Each Job | 1,500 ₹7,500 | 1,400 ₹7,000 Lowest | 2,500 ₹12,500 |
| 8.00 | Takingdown old /unserviceable street light fiting from LT pole Opening the fittings and checking all connection and repair the same by replacement of LED driver of 70 watt complete all as specified and as directed by engr-in -charge. | 30 | Each | 600 ₹18,000 | 600 ₹18,000 | 450 ₹13,500 Lowest |
| 9.00 | Taking down old /unserviceable street light fiting from LT pole Opening the fittings and checking all connection and repair the same by replacement of LED driver of 45/30 watt complete all as specified and as directed by engr-in -charge. | 20 | Each | 300 ₹6,000 Lowest | 500 ₹10,000 | 400 ₹8,000 |
| 10.00 | Supply & Fix in repair LED Post top lantern weather proof indirect lighting solution Make Cormpton Cat Pt No LPTC-40-CDL or equivalent in Havells/Bajaj.complete all as specified and directed by Engineer- in-charge. | 4 | Each | 6,000 ₹24,000 Lowest | 8,400 ₹33,600 | 7,000 ₹28,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
28 Apr 2025, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
REPAIR/ REPLACE. OF STREET LIGHT, INT. ELECTRIC. , SOLAR WATER HEATER, METER PANEL, EARTHING, LIGHTNING PROTECTION, U/S PIPES, PUMP HOUSES AND COMP. MAINT OF W/S INSTALLATION IN DOMESTIC , TECHNICAL AND RAKSHA NAGER AREA AT AF STN OJHAR.
2025_MES_702836_1
8287/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹90,000
Yes
13 Oct 2025
28 Mar 2025
30 Apr 2025
29 Mar 2025
28 Apr 2025
14 Apr 2025
Amount
Taking down old unserviceable street light fittings /high way light /flood light/Watch tower light ) of any type and capacity up to 15 mtr heights and deposited to MES store yard for further disposal.
Fixing only of street light , flood light, high bay light, high mast light, Focus light or any type of light to be fix on wall /pole/ hanger etc with the help of suitable size of nut bolt washer etc including all electrical connection connection as required at site ( Note - Material /store will be issued under schedule be )
Supply, Installation, Testing and commissioning LED street light fittings 70 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No CRP-421-70-57-SL-LM-NSG with 5 years of warranty or equivalent in Havells/Phillips.complete all as specified and directed by Engineer- in-charge..
Supply, Installation, Testing and commissioning LED street light fittings 60 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No CRP-421-60-57-SL-LM-NSG with 5 years of warranty or equivalent in Havells/Phillips. complete all as specified and directed by Engineer- in-charge..
Supply, Installation, Testing and commissioning LED street light fittings 25 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No TRP-415-25-57-SL-LM-NBK with 2 years of warranty or equivalent in Havells/Phillips. complete all as specified and directed by Engineer- in-charge.
Supply & Fix in repair PVC perplex cover glove type with Base plate /holder not less than 8 inch dia suitable for Post top lantern including one nos 7/9 watt LED lamp complete all as specified and directed by Engineer- in-charge.Make - Bajaj / Surya/*havells.
Repairs to High mast light 15/30 Mtr high, by taking down the luminaires mounting frame mechanically and replacing the unserviceable items (paid separately) including lifting the superstructure after repairs and testing complete all as specified and as directed by Engr-in- Charge..
Takingdown old /unserviceable street light fiting from LT pole Opening the fittings and checking all connection and repair the same by replacement of LED driver of 70 watt complete all as specified and as directed by engr-in -charge.
Taking down old /unserviceable street light fiting from LT pole Opening the fittings and checking all connection and repair the same by replacement of LED driver of 45/30 watt complete all as specified and as directed by engr-in -charge.
Supply & Fix in repair LED Post top lantern weather proof indirect lighting solution Make Cormpton Cat Pt No LPTC-40-CDL or equivalent in Havells/Bajaj.complete all as specified and directed by Engineer- in-charge.
Supply & Fix in repair Post top lantern decorative HERITAGE LED suitable 1X20 Watt retro LED with opel deffuser including LED 20 Watt of Make Crompton Cat Part No LPTH-20-CDL or equivalent in Havells/ Wipro.complete all as specified and directed by Engineer- in-charge.
Material and labour for cable joint termination box PVC body housing (200X140X95 mm)suitable for housing and including 100 amps rated, 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tublar pole with 25x3 mm FI clamps with nut, bolts and washers and including one 6 amps MCB, SP, 240 volt for street light supply complete all as as directed by Engr-in-charge.
Material and labour for cable joint termination box PVC body housing (140X140X95 mm)suitable for housing and including 100 amps rated, 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tublar pole with 25x3 mm FI clamps with nut, bolts and washers and including one 6 amps MCB, SP, 240 volt for street light supply complete all as as directed by Engr-in-charge.
S&F PVC insulated and weather proof three core copper multi stranded conductor cable 1.5 Sqmm size as required length for replacing unserviceable cable for street light where ever found unserviceable and required from junction box to street light connector of Street Light fittings all as specified & as directed by Engr-in-Charge.
Taking down existing copper/aluminum existing point wiring (light/fan/socket or power points) complete (fittings such as switches,ceiling roses,pendents, regulators, sockets etc to be measured saperatly) incl wooden battens and conduct etc & removing material as directed complete all as specified and as directed by Engr-in-Charge.
M&L for Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in and including surface in wall/celling/floor PVC casing caping as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including PVC boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr-in-Charge.
All as per item no 16 but for One 5 Amps socket point on same/below board with other switches.
All as per item no 16 but for One 5amps switch socket point independent.
All as per item no 16 but for One 15amps switch socket power point
Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge.
All as per item no 20 but for One 5 Amps socket point on same/below board with other switches.
All as per item no20 but for One 5amps switch socket point independent.
M&L for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in wall/floor PVC medium grade conduit not less than 20 mm as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
Supplying and fixing in repairs Modular white cover plate with frame, 3 Module, Make Legrand /Anchor Roma/Crabetree.
Supplying and fixing in repairs Modular white cover plate with frame, 6 Module, Make Legrand /Anchor Roma/Crabetree.
Supply & fix metal fiush mounting box 3 module.
Supply & fix metal fiush mounting box 6 module.
Supply & fix rigid non metelic PVC conduit not less then 20mm/Casing caping exclusive of boxes (junction/terminal) but inclusive of all tee,bends, elbow, reducer bell mount tube ends and fixing accessories such as coupler, lock nuts saddles, pipe hooks etc in surface in wall/celling/floor etc. complete all as specified & directed.
M&L wiring for circuit/ sub main wiring of 2x1.5 Sqmm + 1x1.5 Sqmm earth wire, alongwith eart wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in surface/ recessed as required in PVC casing caping complete all as directed by Engr -in- Charge.
M&L wiring for circuit/ sub main wiring of 2x2.5 Sqmm + 1x2.5 Sqmm earth wire, alongwith earth wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in surface/concealed as required in PVC cassing N capping complete all as directed by Engr -in- Charge.
M&L wiring for circuit/ sub main wiring of 2x4 Sqmm + 1x4 Sqmm earth wire, alongwith eart wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in surface/ recessed as required in PVC casing caping complete all as directed by Engr -in- Charge.
M&L wiring for circuit/ sub main wiring of 2x6 Sqmm + 1x6 Sqmm earth wire, alongwith eart wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in surface/ recessed as required in PVC casing caping complete all as directed by Engr -in- Charge.
Fixing only of tube light , POP light, ceiling light, Focus light or any type of light to be fix on wall /ceilling with the help of suitable size of nut bolt washer etc including all electrical connection connection as required at site ( Note - Material /store will be issued under schedule be )
Supply and fix in repair Modular switch one way 6 Amp,1 Module , Make Anchor/Roma/Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular switch one way 16 Amp, 1 Module , Make Anchor/ Roma,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular bell push 6 Amp,1 Module , Make Anchor/ Roma/Legrand,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular Fan regulator electronic step type 230 V 2 Module. Make : Anchor/Roma Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular Socket outlet 6A/16 Amps 2/3 pin combined 2 module Make : Anchor/Roma. ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular Socket outlet 6 Amps 2/3 pin combined 2 module Make : Anchor/Roma ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Ding Dong AC 230 Volts single pole. Make : Anchor/Press Fit,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Switch socket combination outlet 5 pin 6 Amps 16 Amps 2 in 1 flush type.Make: Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Switch socket combination outlet 5 pin 5 Amps 2 in 1 flush type Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Lamp holder PVC/polycarbonate insulated body with back plate suitable for angle fittings. Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Ceiling rose surface type, PVC/Polycarbonate isolated body size 50x28 mm three terminals. Make : AnchorHavells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCB SP 6 to 32 Amps 240 volts 10 KA C series. Cat part No-408595 Make : Legrand/ L & T./Standard ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCB SPN 32 to 40 Amps 240 volts 10 KA. Cat Part No-408617 Make : Legrand /Standard/L & T,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCB TPN 40 to 63 Amps 240 volts 10 KA. Cat Part No-408617 Make : Legrand /Standard/L & T,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s SPN, with 200 amps rated bus bar ,8 way ,240 volts double door. Make : Standard/HPL/Legrand.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s TPN, with 200 amps rated bus bar , 4 way ,415 volts double door. Make :Standard/Legrand/L&T.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fixing LED bed side reading light fitting 3 watt powder coated housing with noveable string, metalic base complete with driver to operate 240V AC 50 Hz suitable for indoor appilcation.Make shakti cat No-SZWRFPX003 OR EQUIVALENT.
Supply and fixing LED PICTURE light 10 watt aesthetically designed with multiple body colour options, high efficiency LED, inbuilt driver for indoor appilcation.Make shakti cat No-SZWRFPX010 OR EQUIVALENT.
Supply and fixing LED under water fountain light 6 watt outdoor , IP 68 , 3000K.Make shakti cat No-SZLFUM006W OR EQUIVALENT.
M&L High brightness LED strip rope 144 D strip 3000K IP65 with uniformity of light required for perfect outdoor application ( 50 Mtr roll) complete with clamp, saddle or locking strip as required at site all as specified and as directed by Engr-in-Charge.Make Havells - cat No LHEHBQP5TN6F325 equivalent in Cromptom and phillips.
M&L for LED strip 24 W 3000K with uniformity of light distribution and long lasting adhesive for perfect cove lighting solution (5 mtr roll ) complete with clamp, saddle or locking strip as required at site all as specified and as directed by Engr-In-Charge. Make Havells – cat No LHEDLP5UN1W024 equivalent in Crompton and Phillips.
Supply & Fix in repair Inverted pyramid tripod type LED Bollard with soft 360% light distribution light distribution , IP 66, LED 10 Watt warm white of Make Crompton Cat Part NoLBLSN-10-WW or equivalent in Havells/ Wipro.complete all as specified and directed by Engineer- in-charge.
Supply,install,testing and commissioning of indoor type cbical metering panel board outer shell made out of 2.0 mm thich MS sheet with transparent glass window of size not less than 600X600XX250 mm and fixed on MS angle of suitable size on Wall/Floor withsuitable size of nut, bolt and washer , frame factory fabricated withfront openable 3 phase , 4wire 415 volt, 50 Hz, including taking down old existing electric meter and refixing the same in new metering panel incl all electrical connections complete all as specified and directed by Engr-in-charge and compriseing with following (a)TPN aluminium bus bar 200 Amp insulated with colour coded heat shhrikable sleeve and shall be mounted on suitable size 'F' class insulators (b) Incoming MCCB 63 Amps 16 KA ,415 Volts, 50 Hz, FP-01 No (c) Out going MCB SP 40 Amp-05No (d) Space for installation of electric meter-05 No (e) LED Indicating lamp -01 set of three
S&F ceilling fan 1200 mm sweep operated on 230/240V AC Single phase electric supply complete including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector complete all as per specified and directed by Engr-in- Charge .
S&F Exhaust fan 300 mm sweep, 4 blade ( Mettallic type ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connectorcomplete all as per specified and directed by Engr-in- Charge . Make Crompton, havells , Usha
S&F Exhaust fan 300 mm sweep, 4 blade ( PVC ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector complete all as per specified and directed by Engr-in- Charge . Make Crompton, havells , Usha
S&F Exhaust fan 250 mm sweep, 4 blade ( PVC ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector complete all as per specified and directed by Engr-in- Charge . Make Crompton, havells , Usha
S&F Exhaust fan 200 mm sweep, 4 blade ( PVC ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector complete all as per specified and directed by Engr-in- Charge . Make Crompton, havells , Usha
M&L for periodical maintenance / break down maint of solar water Heater 300 TO 500 LPD ( Flat plate collector type) on G+3 stories bldgs. by checking & Testing all connected part and repair/ maintenance of leakage in pipe , tank panels or any plumbing issues, cleaning the panels , repair the crack in the insulation, painting the rusted surface, drain the collector and pipe , cleaning the vegetation growth and dust accumulated on the collectors, descaling the collectors and water storage tank) with the help of acid. complete maintenance for fully operation of solar water heater all as specified and as directed by Engr-in-charge
M&L for Taking down old damage Solar water tank from site (G+3 storeybldgs) and supply and fixing new solar water storage tank as per existing make and size and type duly fixed on original position for fully operation of solar water heater all as specified and as directed by Engr-in-charge
M&L for Taking down old damage Solar water heater flate plate collector (FPC) from site repair/ weilding the same at site (on G+3) storey building ) for weilding of leakaga portion and refixing the same on its original position for fully operation of solar water heater all as specified and as directed by Engr-in-charge
M&L for earthing in repair including taking out GI plate with pipes earthing lead fasteners etc and earthing complete with galvanised steel earth plate electrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level,connected to 4 mm dia GI earth wire as earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, protected by and including GI pipe 40 mm bore (light grade) and connected to main switch / MCB DBs box point / LP test point as directed and including cement concret pit in 1:2:4 type B1 using 12.5mm graded aggregate, with cast iron miled steel frame embedded in the concrete enclouser fineshed flushed & CI cover 10 mm thick of size (300mmx300mm CI) having locking arrengment hinged to CI frame all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel 20 mm bore GI pipe medium grade for watering adequate quantity of black soil and charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) Filling the pit with black cottan soil brought at site. ii) The excavated soil will be removed & paid separtely.
M&L for carrying out physical inspection and measurement of individual earth pit resistance of each earth pit, every month located at MES Installations and maintain the record of its reading month wise and submit to this office duly signed by user,s with satisfactory working remarks as a token of acknowledgement to office monthly for measuring the resistance of individual electrode of LV distribution system and other non-DG/ Transformer by fall of potential test in case fall of potential method is not possible at certain locations then measurement of earth pit resistance shall be carried out in stake less method using current and voltage clamps.(Total earthing not less than 100 ) Nos earth pit located in different area of this station shall be measured in each month or all as directed. Pit for measurement of pit resistance including necessary excavation in any type of soil, or braking of hardstanding for inserting of spikes complete all as directed by Engineer-in-Charge. The rate also include to inspect and measure resistance of any type of earth( like conventional or chemical, strip or wire any size) complete. Note-(i) Minimum 22 Earthings per working day and 100 % within a month to be cheked and testing will be carried out, testing equipment should be calibrated and certified from appropriate Govt Authority. Testing of earth resistance should be carried out in presense of the users and record should be furnished to the AGE E/M Office on daily basis, Failing which a recovery @ Rs 500 per eathing per day will be recovered as penalty.
Repair of old earthing for improvement of earth resistance by removing of old pit Chemeber from existing site , disconnecting all earth electrode of any type and size excavated the pit and removing old existing earth plate any type (BY ECAVATION OF 3.25mete deep ), cleaning the same and burried directly in ground with new bolts,nuts ,washer and check nut of galvanized steel,filling adequate quantity of charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode and including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) The material as salt, charcoal, Magnesium sulphate,GI Plate, wire mesh funnel will be measured and paid seprately.
Supply only Salt
Supply only Char coal
Supply only Magnesium sulphate
Supply only Back fill compound (SGI Engineer or equvalent )
Supply only Wire mesh funnel
S&F in replacement of microprocessor based single phase, AC electronic tamper proof static energy meter LCD display Electronic KWH meter of capacity 5-30 Amp, 240 Volts, 50 HZ, accuracy class 1 , KWh compact meter with pilfer proof meter bo with sealing screw provision base mounting, projection mounted Cat no- SPPB1310000002OC00 of Make:- HPL / L&T
Supply & fix earth continuty conductor or main earthing lead of 4 mm dia galvanised iron or steel wire. (roof conductor or down conductor ) above ground level fixed to wall/ roof duly insulated on batten or fixed on new porcelain insulators with clamping device or recessed or chases or burried in groung/ floor or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as directed by Engg. in charge. Note :- i) the distance between porcelain insulator will not be included with cost of T & P and labour required to work on roof top at lateral faces of existing hangers upto height of 25 mtrs.
All as per item no-74 but 25 x 4 mm galvanised iron strip.
All as per item no-74 but 32 x 6 mm galvanised iron strip.
All as per item no-74 but 32 x 6 mm copper strip.
All as per item no-74 but 25 x 3 mm copper strip.
Taking down existing Copper strip/GI strip any size with its accessories and refixing the same complete all as directed.
Dismantling and taking down dislocated/de-shaped/loose earth contunity conductor down or roof conductor in any position for re-fixing properly or for replacement complete including UNSV insulators/clamps/ saddles ets Aluminum strip of any size. Note :- The quoted rates shall be deemed to be included with cost of T&P and labour required to work on roof top and at lateral faces of existing hangers upto height of 25 Mtrs.
Supply & Fix 25 x 3 mm aluminium strip ( Roof conductor or down conductor) above ground level fixed to wall/ roof duly insulated fixed on and including new porcelain insulators with clamping device or recessed or chases or burried in ground/ floor or drawn in conduit / pipe or fixed to poles or any other indicated situation or for loop earthing etc. Note :- i) The consecutive distance between porcelain insulator will not be more than 40 cm. ii) The quoted rates shall be deemed to be included with cost of T&P and labour required to work on roof top and at lateral faces of existing hangers upto height of 25 Mtrs.
Re-fixing the taken down aluminium strip on roof top/on wall/lateral faces fixed on new porcelain insulator including new GI bolt, nut, washer provide at a distance not more than 40 Cm consecutively. Note :- i) The quoted rates shall be deemed to be included with cost of T&P and labour required to work on roof top at lateral faces of existing hangers upto height of 25 Mtrs. i) The consecutive distance between porcelain insulator will not be more than 40 iii) The cost of porcelain insulators will be paid under relivant item here in under but cost of GI bolt nut, washer etc is deemed to be included under quoted rates.
M&L for Air termination, single pointed aluminium rod 12 mm dia and 300 mm long, includind dismantling and taking out old unservicable termination complete all as specified and as directed.
M&L in repairs for PCC block on roof top comprising 1:3:6 of required size at places where directed & laying,clamping the strip any size secured on the block with suitable size GI bolt duly grouted, nut bolt washer etc.
M&L for test point terminal block insulated from wall or external surface made of gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screws complete fixed on ebonite sheet 6mm thick fitted on MS flat 50x5mm bent to shape etc complete all as specified and as directed.
M&L in repairs to earthing pit chamber including replacement of PCC chamber, cement concret pit with cast iron miled steel frame embedded in the massonery enclouser finished flushed & PCC cover 10 mm thick (300mmx300mm having locking arrengment hinged to PCC frame all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, complete all as directed.
Supply only PVC insulator for GI/Aluminium strip supporter adequate to accomadate strip of 32 mm with fasteners complete all as specified and directed.
M&L for earthing in repair including taking out GI plate with pipes earthing lead fasteners etc and earthing complete with galvanised steel earth plate electrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the pl;ate not less than 1.5 Mtr below normal ground level,connected to galvanised iron strip 32x6 mm as earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, protected by and including GI pipe 50 mm bore (light grade) and connected to main switch / MCB DBs box point / LP test point as directed and including cement concret pit in 1:2:4 type B1 using 12.5mm graded aggregate, with cast iron miled steel frame embedded in the concrete enclouser fineshed flushed & CI cover 10 mm thick of size (300mmx300mm CI) having locking arrengment hinged to CI frame all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel 20 mm bore GI pipe medium grade for watering adequate quantity of charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) Filling the pit with black cottan soil brought at site. ii) The excavated soil will be removed & paid separtely.
Supply, install, testing and commissioning maintence free earthing comprising of high tensile pure copper (99.99%) earth electrode. 76 mm dia and 3 mtr long copper pipe intallation of earthing electrode boring 165mm dia X4 mtr long with ground enhancing compound ( Make- Earthcon or equvalent ) and back-fll compound ( Make- Terec+ or equvalent ) (not less than 50 Kg ) strictly be a carbon based conductive concreate type which has resistively of less than 0.12 ohm mtr as per clause 14.5 D of IEEE:80 Standard back-fll compound should be electronically conductive (like in metals) and should not depend on moisture for condition.Commissioning, testing & report submission ( result as per requirernent jof user ìn hard rock, mountain) etc Note :-(1). Contractor will executed the work as per soil resistivity reports given by same OEM. However to achieve the result less than 1 Ohm gridding of earth pit should not exceed 4 Nos of earth pits. (2). To achieve results less than 1 ohm contractor wil provide gridding of earth pits as per soil resistivity test report ( but not more than 4 earth pit). Artificial treatment of 12.5 Kg earthon compound per 2 meter as per dwawing attached and excutation and chemical required in area of gridding shall be included in rates quoted by contractor. (3) copper strip required for inter connection of gridding of earth pit shall be paid separtely. (4). Total 30 nos of earth pits of above specification to be executed at site. However gridding wilbe decided as per requirement of earth result and as soil resistivity report. (5) Copper strip of gridding shall be placed under groun level with the depth of 400 to 600 mm with the treatrent of earthcon complound and alluvial soil as drawing.(6). removal of grabbles and stone and add some quantity of earth enhancement material in the soil using a black fill compound and make layer of blach siol / garden soil/ alluvial soil, terrace, compound and earthcon compound repeat tye same procedure around the 76 mm electrode pipe as per drawing. (7).Compound shall be suplied in sealed bags. The earth electrode should finally be housed in heavy duty chamber with cover of suitable size as per OEM recommendation Ground Enhancing compound and Back-fill compound should be enviroment freindly, , ionic property to create ions for easy conduction , the compound should expand so much to remove entrapped air ( bad conductor electricity ) and to creat strong conduction between electrode and soil, the compound should have a property to assist in absorbing humidity from the neightboringsoil to keep the earth pit moisture . The product should be tested and certified at CPRI for long term stability of earth pits. (8) Testing on completion & achiving resistance less than desire result & submitting report to Engineer-in Charge duly signed by user after seccessfull completion of earthing whytime after euevution up to end of defect liabulility perioed. (9) Earth strip copper of size 32x6mm from eath pit to testing point up to 7.5 mtr included in the quoted rates Make:SGI Engineer PVT Ltd or equivalent.
Note :-Compound shall be suplied in sealed bags. The earth electrode should finally be housed in heavy duty chamber with cover of suitable size as per OEM recommendation . Ground Enhancing compound and Back-fill compound should be enviroment freindly, , ionic property to create ions for easy conduction , the compound shoul expand so much to remove entrapped air ( bad conductor electricity ) and to creat strong conduction between electrode and soil , the compound should have a property to assist in absorbing humidity from the neightboringsoil to keep the earth pit moisture . The product should be tested and certified at CPRI for long term stability of earth pits. The testing has to be carried out for minimum duration of two years continously. (f) Testing on completion & achiving resistance less than 01 ohm & submitting report to Engineer-in Charge duly signed by user after seccessfull completion of earthing whytime after euevution up to end of defect liabuility perioed. (g) If resistance value is found more than 1 ohm, contractor has to do additional earthing with in 07 days without any extra cost (h) Earth strip copper of size 32x6mm from earth pit to testing point up to 7.5 mtr included in the quoted rates Make:- SGI Engineers PVT Ltd,
M&L for brazing of existing copper earthing including all brazing materials as required at site complete all as specified and as directed.( Note :- The rate of T&P , Gas cylinder , weilding machine etc are included in the quoted rates quoted by the contractor
M&L for Serivicing & calibration to check 513A Insulation terster , suggested frequency of calibration check: 1 year Note: Charge do not includeany components that may need to be replaced . Pricesare based on return to desk basis. Freight for shipping to testing centre B28 Okhla Industrial area phase 1, new delhi - 110020 and freight from testing location to MES office will be borne by contracto.
M&L for carrying out repairs to existing electric panels/ star delta starter in open execution, identifying the fault/ trouble in wiring, rectifying the wiring fault using suitable flexible copper cable replacement of timer delay (timer), single phasing preventer & suitable relay with new one (as required as per its specification or as specified by Engineer-In-Charge) , rewiring of complete starter using suitable size flexible copper cleaning the panel with blower , removing rust with chemical/ emryi paper cheking copper winding of motor upto 100 HP electric motor and testing of electrical circuit/Pumpset to complete satisfaction of Eng-In-Charge.
S& Fix in replacement DOL starter suitable upto 7.5 HP water pump with timer & contactor to operate pump within specific time limit as per existing make and model complete all as specified and as directed by Engineer-In-Charge.Make: L&T/Siemens/Legrand
Supply & Fix in replacement of Bronze gate valve (Hex type) ISI marked screwed both ends of 50 mm diameter Art No 1006 of Make: Zoloto or Equivalent in Leader/L&T complete all as specified and as directed by Engineer-In-Charge.
All as per item no 94 above but of bore 40 mm dia
All as per item no 94 above but of bore 25 mm dia
All as per item no 94 above but of bore 20 mm dia
All as per item no 94 above but of bore 15 mm dia
Supply, install, testing and commissioning in replacement cubical type LT panel board, indoor type manufactured by CPRI approved factory made floor mounted totally enclosed, dust and vermin proof (front and rear opening)powder coated with RAL 7035 color code, with locking arrangement &backelite plate made of CRCA sheet of 2mm thick IP 55 protected as per IS-5039 duly powder coated of approved shade. The panel shall be suitable for 415 volts, 50 Hz, 3 phase, 4 wire system with suitable size of PVC insulated cop-per conductor cables, thimbles, glands and shall be suitable for housing with rotary handel & spreader mechanism . Note :-1. The cost of the PCC plinth /foundation deemed to be included in the quoted rate of the above said item. 2. ALL MCCB should be operated by veri depth rotary handle. 3.Bus bar directly connected to incomer of outgoing MCCB,s ,not by PVC flexible wires. 4.IP55 class cabinet, the operating access shall be provided through the viewing glass of the acrylic glazed cover 5.Every MCCB and star delta starter shall has separate compartment, hence 2 Nos of compartments 6.V curve ( upper portion)50 mm outside from both side
7.All devices shall be properly grouped and conveniently placed for easy accessibility to the electrician for carrying out replacement or adjustments. 8. All electrical components shall be usually DIN rail mounted. All DIN rails, cable ducts, and other equipment shall be mounted using fixing screws into threaded holes. 9. No more than two wires shall be connected in each terminal. 10. Terminals for power and control voltages shall be individually grouped and properly identified with the help of legend plates. 11. All terminals shall be marked and terminal plans shall be stick inside the panels. 12. Each component should be provided with a legend plate for proper identification as per detailed drawing. 13. Panel wiring shall be done in raceways and it should be ensured that spare capacity in the raceway is provided to take care of future alteration or addition when required. 14. No components shall be provided on the door except operating, signaling, or measuring devices. 15. Mounting and wiring of terminals blocks should be such that internal and external wiring does not cross above the terminals. 16. All conductors should be identified by a tag bearing the number corresponding with the circuit diagram. The tags used shall be of sleeve type. 17. All the mounting plates, doors, etc. should be earthed on a common earthing strip/wire. 18. Only copper flexible wires shall be used for panel wiring
The PMU shall have onboard Digital input terminal Feedback from motor contactor and auto reset alarm. The PMU shall have onboard Digital output terminal for Alarm high stator temperature, Alarm moisture in the motor, Alarm insulation fault and General warning output. The PMU shall have 250VAC potential free contact terminal for alarm. Voltage of the system shall be 24VAC+- 10% 50 to 60Hz or 24VDC+-10% The PMU is IP20 and shall be used indoor installation The PMU shall have a communication option of Modbus RS485 for communicating with BMS/SCADA systems for enhanced operating and monitoring purposes. The PMU shall have indicator lights for sensor status measurement, stator insulation resistance, leakage, vibration in pump, motor temperature, motor running, service of moisture etc. The PMU shall be configure through Potentionmeter and DIP Switch, where Pot can be used to adjust the warning limit of insulation resistance and DIP Switch can be used to configure for the connected pumps All cables (incoming and outgoing) should pass through bottom gland plate with proper size of gland for protection of lizard,snakeetc 12.Cable connection by MCCB's should be by proper lugs and lugs pressed by proper tools . Bimetallic lugs use in case of copper bus bar.
Supply & fix in replacement electromagnetic water flow meter ,remote mounting made up of SS-316L electrode having accuracy +-0.5% of actual flow, earthing SS electrode, operating temperature -10°C to 100°C & for pressure rating of 15 kg/Sq.cm, with FIT flow indicator totalizer and 4-20mA and RS485 Modbus output for SCADA with 4 x 4 digit Red LED Display ,SCADA based IP-65 operating on 230V AC ,single phase with 6 meter cable length cable connection size ANSI150# with PTFE lining and meter size DN 250 mm , of Make :Utkarsh Scietific instrumentation Ltd or Equivalent in Capstan /Kranti complete all as specified and as directed by Eng- In Charge
Supply & Fix in replacement Ball brass valves, high pressure, with polythene float and fly-nut complete,screwed for iron pipe or brass ferrule and fixed screwed both ends of 20 mm diameter Art No 1006 of Make: Zoloto or Equivalent in Leader/L&T complete all as specified and as directed by Engineer-In-Charge.
Supply & Fix in replacement Ball brass valves, high pressure, with polythene float and fly-nut complete,screwed for iron pipe or brass ferrule and fixed screwed both ends of 15 mm diameter Art No 1006 of Make: Zoloto or Equivalent in Leader/L&T complete all as specified and as directed by Engineer-In-Charge.
S & F pressure gauge of dial size 100 mm, bottom connection: 3/8'' bsp MOC: MS casing brass internals( glycerin filled ), Accuracy: +/-2 % FSD, Range: 0-150 psi with 0-10.6 kg/cm2 Make: FIEBIG, complete all as specified and as directed by Engr-In-Charge
supply and fix electrically operated motorized butterfly valve of size 50 mm, Cast Iron body, CF 8 Disc, Seat EPDM, of make Stolzel, along with electric actuator of make Stolzel Model EE 30 Torque 30 Nm, operating time 20 sec, current 0.22 A, voltage 220 VAC/ 24 VDC, Power 24 VDC/220/415 VAC, indicator continous positioning, protection IP 67 Weatherproof, turn: Quarter turn , Feedback 2 NO NC, insulation Class F, Complete all with required fitting and electrical connection, complete all as specified and as directed by engineer-In-Charge.
Supply & Fix PVC BIB COCK STANDARD of size 15 mm (white) , Make - PRAYAG or Equivalent complete all as specified and as directed by Engineer-In-Charge.
Supply, install, testing and commissioning cubical type LT panel board, indoor type manufactured by CPRI approved factory made floor mounted totally enclosed, dust and vermin proof (front and rear opening) with locking arrangement &backelite plate made of CRCA sheet of 2mm thick IP 43 protected as per IS-5039 duly powder coated of approved shade. The panel shall be suitable for 415 volts, 50 Hz, 3 phase, 4 wire system with suitable size of PVC insulated cop-per conductor cables, thimbles, glands and shall be suitable for housing with rotary handel& spreader mechanism . Note :-1. The cost of the PCC plinth /foundation deemed to be included in the quoted rate of the above said item. 2. ALL MCCB should be operated by veri depth rotary handle. 3.Bus bar directly connected to incomer of outgoing MCCB,s ,not by PVC flexible wires. 4.Proper air ventilation in case of IP43 Protection. 5.Every MCCB and star delta starter shall has separate compartment 6.V curve ( upper portion)50 mm outside from both side
7.Panel should be operated from front side only(dead Rear side) 8.Neoprene gasket at doors 9.Outdoor panel sheet thickness 3.15 mm and indoor panel sheet thickness 2 mm unless otherwise specified. 10.Panel handle should be rubber grip insulated or polycarbo-nate handle( panel should Not opened by Nude steel handle ) 11. All cables (incoming and outgoing) should pass through bottom gland plate with proper size of gland for protection of lizard,snakeetc 12.Cable connection by MCCB's should be by proper lugs and lugs pressed by proper tools . Bimetallic lugs use in case of copper bus bar. 13.Line diagram stick on inner side of door ( coloured paper sheet and laminated) 14.Every compartment has permanent nomeclaturep-late,made of steel,riveted joint( not sticker) like( Example-MCCB,160Amps,4P,36KA) 15.Danger notice plate ,made of steel,riveted joint (not sticker) 16.Name plate,made of steel ( Manufacturer name,Year of manufacturing,IP -54/43)
Supply only LED Flood light fittings 50 watt with 110 lm/ watt system lumen output . The luminaire should have cool white coloure temperature with minimum 5700K . The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, lumen efficiency of 120 lumen /W, isolated electronic LED driver ( SMPS based constant current supply), IK-07, life class of 50,000 hrs @ L 70, surge voltage protection not less than 10 KV Make Crompton CAT No TFS-504-50-57-NL-SL-GL-NBK or equivalent in Havells/ Philips.complete all as specified and directed by Engineer- in-charge.
Supply & fix in repair/replacement of decorative LIARA LED Bollard IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360º light distribution Crompton Cat pt LBLSN-10-CDL or as require site ,complete all as specified & as directed by Eng-In-Charge.
S& F Green coloured fencing net non stiched sun shade suitble for SUMP cover trapping leaves, tree branches, twigs etc. Complete all as specified and as directed by Engineer- In-Charge.
S& F Twin LED Aviation Light with polycarbonate diffuser & Cast aluminium housing IP 65, Cat No- SZPALMX-2 Make Shakti . Complete all as specified and as directed by Engineer- In-Charge.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in soft loose soil all as specified and directed
Returning, filling in including spreading, levelling watering and well ramming in layer not exce 25 cm, all as specified and directed
Removing excavated soil to a distance not exce 50 mtr and deposited where directed at a level not exceding 1.5 mtr abvoe the starting point all as specified and directed.
M&L for Cutting existing CI/DI/MS pipe in position for insertion of new pipe/tees, branches etc. of size 300 mm dia
All as per Item No.114 above but 150 mm dia
Supply & fix mechanical joint ISI marked for spigot end pipe of size : 300 mm Note : Rate for excavation and earth work incl T&P as reqd at site for each joint are deemed to be included in quoted rates.
All as per Item No.116 above but 150 mm
S&F Sluice valve 300 mm ( 12 " ) ISI marked PN-1.6 confirming to IS14846 both ends flanged with brass stem /spindle and check nut with solid wedge of trim copper alloy gland packing lubricated hemp jule flange as per IS-1538, iron wheel head check nuts etc including jointing with rubber gaskets, nuts, bolts and washer of sizes 300 mm dia Art No 1079A of Make:Zoloto or Equivalent in Leader/Kirloskar with operating wheel ,complete all as spectified and directed by Engr-In-Charge.
All as per Sl. Item No.118 here in before but of sizes 150 mm dia Art No 1079A of Make:Zoloto or Equivalent in BIR/SIR ,complete all as specified and as directed by Engineer-In-Charge.
Dismantling old unserviceable valve chamber & Material & Labour for construction of valve chamber of size 1.20x1.20x1.20 mtrs internal dimension complete of brick masonary of 23 cm thick in cement mortar 1:6 on PCC 1:4:8 foundation 75 mm thick using 40 mm graded stone aggregates & coping in PCC having wall thickness of 0.26 mtrs 1 :3:6 10 mm thick at the top of brick wall using 20 mm graded stone aggregates and 10 mm thick plastering in cement mortar 1:4 on exposed brick or concrete surfaces & MS cover of 3.15 mm thickness including 40 mm×40mm× 6 mm angle iron frame fixed with the same size of angle iron hold fast,handle with locking arrangement & two coats of synthetic enamel paint over one coat of red oxide primer on steel surface and two coats of white wash on plastered concrete surface ,complete all as specified and as directed by Engineer-In-Charge.
S&F all type of fitting for MS pipes -Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc,) Tee pieces single branch. "Y" juction, double branch, cross (all sockets or socket and spigot) collars, flanges caps and plugs upto 300 mm bore including welding the same at desired location all as specified and directed by Engineer-in -Charge
Material & Labour for laying MS pipe of 300 mm dia Medium grade in trench/surface including necessary cutting,welding/fabrication work & including suitable size SS304 Nut bolts to connect MS flanges, complete all as specified and as directed by Engineer In Charge.
All as per item no- 122 but for size 150 mm
Supply, install, testing and commissioning cubical type LT panel board, indoor type manufactured by CPRI approved factory made floor mounted totally enclosed, dust and vermin proof (front and rear opening) with locking arrangement &backelite plate made of CRCA sheet of 2mm thick IP 43 protected as per IS-5039 duly powder coated of approved shade. The panel shall be suitable for 415 volts, 50 Hz, 3 phase, 4 wire system with suitable size of PVC insulated cop-per conductor cables, thimbles, glands and shall be suitable for housing with rotary handel& spreader mechanism . Note :-1. The cost of the PCC plinth /foundation deemed to be included in the quoted rate of the above said item. 2. ALL MCCB should be operated by veri depth rotary handle. 3.Bus bar directly connected to incomer of outgoing MCCB,s ,not by PVC flexible wires. 4.Proper air ventilation in case of IP43 Protection. 5.Every MCCB and star delta starter shall has separate compartment 6.V curve ( upper portion)50 mm outside from both side
7.Panel should be operated from front side only(dead Rear side) 8.Neoprene gasket at doors 9.Outdoor panel sheet thickness 3.15 mm and indoor panel sheet thickness 2 mm unless otherwise specified. 10.Panel handle should be rubber grip insulated or polycarbo-nate handle( panel should Not opened by Nude steel handle ) 11. All cables (incoming and outgoing) should pass through bottom gland plate with proper size of gland for protection of lizard,snakeetc 12.Cable connection by MCCB's should be by proper lugs and lugs pressed by proper tools . Bimetallic lugs use in case of copper bus bar. 13.Line diagram stick on inner side of door ( coloured paper sheet and laminated) 14.Every compartment has permanent nomeclaturep-late,made of steel,riveted joint( not sticker) like( Example-MCCB,160Amps,4P,36KA) 15.Danger notice plate ,made of steel,riveted joint (not sticker) 16.Name plate,made of steel ( Manufacturer name,Year of manufacturing,IP -54/43)
SONA LAKSHMI ASSOCIATE (BID ID -3284446)
United Enterprises (BID ID -3288627)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .